• 제목/요약/키워드: Diffusion-Weighted Image

검색결과 98건 처리시간 0.025초

Study of Apparent Diffusion Coefficient Changes According to Spinal Disease in MR Diffusion-weighted Image

  • Heo, Yeong-Cheol;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • 제22권1호
    • /
    • pp.146-149
    • /
    • 2017
  • In this study, we compared the standardized value of each signal intensity, the apparent diffusion coefficient (ADC) that digitizes the diffusion of water molecules, and the signal to noise ratio (SNR) using b value 0 400, 1400 ($s/mm^2$). From March 2013 to December 2013, patients with suspicion of simple compound fracture and metastatic spine cancer were included in the MR readout. We used a 1.5 Tesla Achieva MRI system and a Syn-Spine Coil. Sequence is a DWI SE-EPI sagittal (diffusion weighted imaging spin echo-echo planar imaging sagittal) image with b-factor ($s/mm^2$) 0, 400, 1400 were used. Data analysis showed ROI (Region of Interest) in diseased area with high SI (signal intensity) in diffusion-weighted image b value 0 ($s/mm^2$) Using the MRIcro program, each SI was calculated with images of b-value 0, 400, and 1400 ($s/mm^2$), ADC map was obtained using Metlab Software with each image of b-value, The ADC is obtained by applying the ROI to the same position. The standardized values ($SI_{400}/SI_0$, $SI_{400}/SI_0$) of simple compression fractures were $0.47{\pm}0.04$ and $0.23{\pm}0.03$ and the standardized values ($SI_{400}/SI_0$, $SI_{400}/SI_0$) of the metastatic spine were $0.57{\pm}0.07$ and $0.32{\pm}0.08$ And the standardized values of the two diseases were statistically significant (p < 0.05). The ADC ($mm^2/s$) for b value 400 ($s/mm^2$) and 1400 ($s/mm^2$) of the simple compression fracture disease site were $1.70{\pm}0.16$ and $0.93{\pm}0.28$ and $1.24{\pm}0.21$ and $0.80{\pm}0.15$ for the metastatic spine. The ADC ($mm^2/s$) for b value 400($s/mm^2$) was statistically significant (p < 0.05) but the ADC ($mm^2/s$) for b value 1400 (p > 0.05). In conclusion, multi - b value recognition of signal changes in diffusion - weighted imaging is very important for the diagnosis of various spinal diseases.

An Unusual Case of Japanese Encephalitis Involving Unilateral Deep Gray Matter and Temporal Lobe on Diffusion-Weighted MRI

  • Seok, Hee Young;Lee, Dong Hoon
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권4호
    • /
    • pp.250-253
    • /
    • 2016
  • Acute Japanese encephalitis (JE) is an endemic viral infectious disease in various parts of Far East and Southeast Asian countries including Korea. Bilateral thalami are the most common involving sites in JE. Other areas including the basal ganglia, substantia nigra, red nucleus, pons, cerebral cortex and cerebellum may be also involved. We report an extremely unusual brain diffusion-weighted MR imaging (DWI) findings in a 53-year-old man with serologically proven JE involving unilateral deep gray matter and temporal lobe, which shows multifocal high signal intensities in left thalamus, left substantia nigra, left caudate nucleus and left medial temporal cortex on T2-weighted image and DWI with iso-intensity on apparent diffusion coefficient (ADC) map.

뇌실질내의 확산강조영상 소견 (Diffusion-weighted MR imaging findings of intracerebral hematoma)

  • 박창숙;최순섭;오종영;박병호;김기욱;남경진;이영일
    • Investigative Magnetic Resonance Imaging
    • /
    • 제6권1호
    • /
    • pp.21-27
    • /
    • 2002
  • 목적: 뇌실질내 혈종의 시기별 확산강조영상 소견을 알아보고자 하였다. 대상 및 방법: 임상적으로 뇌출혈의 시기가 분명한 환자 17명을 대상으로 하였다. 확산강조영상은 1.5 tesla 자기공명영상 기기를 이용하였으며, b 값은 세 방향 모두 $1000{\;}sec/\textrm{mm}^2$으로 하였다. 출혈 시기는 12시간 이하인 초급성기 5예, 3일 이하인 급성기 4예, 3주이하의 아급성기 4예, 3주 이후의 만성기 4예였다. 확산강조영상에서 혈종의 중심부와 주변부의 신호강도를 뇌실질 신호와 비교하여 bright, high, iso, low, dark 신호로 분류하여 분석하였으며, 각 시기의 T2강조영상과 T1강조영상에서의 신호강도와 비교 관찰하였다. 결과: 확산강조영상에서 초급성기 혈종의 중심부와 주면부는 각각 high와 dark신호를 보였고, 급성기는 중심부와 주변부가 각각 dark와 high-bright 신호강도를 보였다. 아급성기와 만성기는 중심부와 주변부가 high-bright와 dark 신호강도를 보였다. 시간 경과에 따른 혈종의 신호 변화는 전체적으로 T2강조영상에서의 신호 변화와 비슷하나, T2강조영상에 비해 빠르고 현저한 신호 변화를 보였다. 결론: 뇌실질내 혈종은 확산강조 자기공명영상에서 중심부와 주변부의 신호강도가 시기별로 특징적으로 변하며 중심부는 초급성기, 아급성기와 만성기에 high-bright신호를, 급성기에는 dark 신호를 보였고, 주변부는 초급성기, 아급성기와 만성기에 dark 신호를, 급성기에는 high-bright 신호를 보였다.

  • PDF

Studies on the Ability to Detect Lesions According to the Changes in the MR Diffusion Weighted Images

  • Kim, Chang-Bok;Cho, Jae-Hwan;Dong, Kyung-Rae;Chung, Woon-Kwan
    • Journal of Magnetics
    • /
    • 제17권2호
    • /
    • pp.153-157
    • /
    • 2012
  • This study evaluated the ability of Diffusion-Weight Image (DWI), which is one of pulse sequences used in MRI based on the T2 weighted images, to detect samples placed within phantoms according to their size. Two identically sized phantoms, which could be inserted into the breast coil bilaterally, were prepared. Five samples with different sizes were placed in the phantoms, and the T2 weighted images and DWI were obtained. The Breast 2 channel coil of SIEMENS MAGNETOM Avanto 1.5 Tesla equipment was used for the experiments. 2D T2 weighted images were obtained using the following parameters: TR/TE = 6700/74 msec, Thickness/gap = 5/1 mm, Inversion Time (TI) = 130 ms, and matrix = $224{\times}448$. The parameters of DWI were that TR/TE = 8100/90 msec, Thickness/gap = 5/1 mm, matrix = $128{\times}128$, Inversion Time = 185 ms, and b-value = 0, 100, 300, 600, 1000 s/mm. The ratio of the sample volume on DWI compared to the T2 weighted images, which show excellent ability to detect lesions on MR images, was presented as the mean b-value. The measured b-value of the samples was obtained: 0.5${\times}$0.5 cm=0.33/0.34 square ${\times}$ cm (103%), 1${\times}$1 cm=1.28/1.25 square ${\times}$ cm (102.4%), 1.5${\times}$1.5 cm = 2.28/2.67 square ${\times}$ cm (85.39%), 2${\times}$2 cm=3.56/4.08 square ${\times}$ cm (87.25%), and 2.5${\times}$2.5 cm=7.53/8.77 square ${\times}$ cm (85.86%). In conclusion, the detection ability by the size of a sample was measured to be over 85% compared to T2 weighted image, but the detection ability of DWI was relatively lower than that of T2 weighted image.

Substantia Nigra after Striatal Infarction on T2- Weighted MR Images

  • Park Byung-Rae
    • 대한의생명과학회지
    • /
    • 제11권3호
    • /
    • pp.307-310
    • /
    • 2005
  • Cerebral ischemia results in neuronal changes in remote areas that have fiber connections with the ischemic area. The aim of this study was to investigate the nigral changes by examining the correlation between the apparent diffusion coefficient (ADC) and the tissue structure. Sprague-Dawley rats were subjected to middle cerebral artery occlusion. Four days after the occlusion, when T2-weighted images revealed the presence of an area of high signal intensity in the ipsilateral substantia nigra, and the ADCs were calculated and imaged. Histopathologic examination by both light and electron microscopy was performed on day 4 after surgery. This finding was consistent with the high signal intensity seen on T2-weighted and diffusion-weighted images, as well as with the ADC reduction, but we did not expect to observe uniform ADC reduction attributable mainly to astrocytic swelling in the perivascular end-feet.

  • PDF

뇌 확산강조 자기공명영상에 대한 정량적, 성적 평가: 1.5 T와 3.0 T 기기 비교 (Quantitative and Qualitative Evaluation of Brain Diffusion Weighted Magnetic Resonance Imaging: Comparision with 1.5 T and 3.0 T Units)

  • 구은회;동경래
    • 방사선산업학회지
    • /
    • 제10권4호
    • /
    • pp.227-230
    • /
    • 2016
  • DWI of biological effects are independent of magnetic field strength in various regions. High field strength, however, does affect the signal to noise ratio (SNR) and artifacts of diffusion weighted imaging (DWI) images, which ultimately will influence the quantitative of diffusion imaging. In this study, the effects of field strength on DWI are reviewed. The effects of the diseases also are discussed. Comparing DWI in cerebellum, WM, GM, Hyperacute region measurements both as a function of field strength (1.5T and 3.0T). Overall, the SNR of the DWI roughly doubled going from 1.5 T to 3.0 T. In summary, DWI studies at 3.0 T is provided significantly improved DWI measurements relative to studies at 1.5T.

Feasibility of Simultaneous Multislice Acceleration Technique in Diffusion-Weighted Magnetic Resonance Imaging of the Rectum

  • Jae Hyon Park;Nieun Seo;Joon Seok Lim;Jongmoon Hahm;Myeong-Jin Kim
    • Korean Journal of Radiology
    • /
    • 제21권1호
    • /
    • pp.77-87
    • /
    • 2020
  • Objective: To assess the feasibility of simultaneous multislice-accelerated diffusion-weighted imaging (SMS-DWI) of the rectum in comparison with conventional DWI (C-DWI) in rectal cancer patients. Materials and Methods: This study included 65 patients with initially-diagnosed rectal cancer. All patients underwent C-DWI and SMS-DWI with acceleration factors of 2 and 3 (SMS2-DWI and SMS3-DWI, respectively) using a 3T scanner. Acquisition times of the three DWI sequences were measured. Image quality in the three DWI sequences was reviewed by two independent radiologists using a 4-point Likert scale and subsequently compared using the Friedman test. Apparent diffusion coefficient (ADC) values for rectal cancer and the normal rectal wall were compared among the three sequences using repeated measures analysis of variance. Results: Acquisition times using C-DWI, SMS2-DWI, and SMS3-DWI were 173 seconds, 107 seconds, (38.2% shorter than C-DWI), and 77 seconds (55.5% shorter than C-DWI), respectively. For all image quality parameters other than distortion (margin sharpness, artifact, lesion conspicuity, and overall image quality), C-DWI and SMS2-DWI yielded better results than did SMS3-DWI (Ps < 0.001), with no significant differences observed between C-DWI and SMS2-DWI (Ps ≥ 0.054). ADC values of rectal cancer (p = 0.943) and normal rectal wall (p = 0.360) were not significantly different among C-DWI, SMS2-DWI, and SMS3-DWI. Conclusion: SMS-DWI using an acceleration factor of 2 is feasible for rectal MRI resulting in substantial reductions in acquisition time while maintaining diagnostic image quality and similar ADC values to those of C-DWI.

Diffusion-Weighted Magnetic Resonance Imaging of the Breast: Standardization of Image Acquisition and Interpretation

  • Su Hyun Lee;Hee Jung Shin;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • 제22권1호
    • /
    • pp.9-22
    • /
    • 2021
  • Diffusion-weighted (DW) magnetic resonance imaging (MRI) is a rapid, unenhanced imaging technique that measures the motion of water molecules within tissues and provides information regarding the cell density and tissue microstructure. DW MRI has demonstrated the potential to improve the specificity of breast MRI, facilitate the evaluation of tumor response to neoadjuvant chemotherapy and can be employed in unenhanced MRI screening. However, standardization of the acquisition and interpretation of DW MRI is challenging. Recently, the European Society of Breast Radiology issued a consensus statement, which described the acquisition parameters and interpretation of DW MRI. The current article describes the basic principles, standardized acquisition protocols and interpretation guidelines, and the clinical applications of DW MRI in breast imaging.

확산강조영상 검사 시 rectangular FOV 적용에 따른 ADC 값의 변화 (A Change of Apparent Diffusion Coefficient in Diffusion Weighted Imaging Applied with Rectangular FOV Technique)

  • 나사라;최관우;구노현;유병규;손순룡
    • 한국방사선학회논문지
    • /
    • 제10권7호
    • /
    • pp.545-550
    • /
    • 2016
  • 본 연구는 MRI를 이용한 기능검사 시 rectangular FOV를 적용하더라도 기능을 정량화한 대표 값은 차이가 없다는 것을 증명함으로써, FOV 불일치로 인해 발생되는 문제점을 개선하고자 하였다. 연구방법은 대표적인 기능 검사로 뇌졸증의 진단에 널리 사용되고 있는 확산강조영상 검사를 이용하여, 주파수부호화 방향의 FOV 변화에 따른 ADC 값의 변화 여부를 비교평가 하였다. 연구결과, 주파수부호화 방향의 FOV가 변화함에 따라 ADC값은 통계적으로 유의한 차이를 보이지 않았으며, 사후분석 결과도 유의수준 0.05에 대한 부집단이 모두 1개 밖에 존재하지 않아 FOV 변화에 따른 ADC 값의 차이가 없음을 알 수 있었다. 결론적으로 MRI를 이용한 기능 영상에서 rectangular FOV를 적용하더라도 기능을 정량화한 대표 값에는 차이가 없으므로, FOV 불일치로 인해 수반되는 공간왜곡이나 mismatching의 문제점을 개선할 수 있다.

Preoperative Assessment of Cystic Brain Lesion : Significance of Diffusion-Weighted Image and ADC (Apparent Diffusion Coefficiency) Values

  • Choi, Hyun-Chul;Lee, Sang-Won;Ji, Cheol
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권6호
    • /
    • pp.371-376
    • /
    • 2007
  • Objective : The aim of this study was to investigate the usefulness of diffusion-weighted imaging [DWI] and apparent diffusion coefficiency [ADC] in distinguishing brain abscesses from cystic or necrotic brain tumors, which are difficult to be differentiated by conventional magnetic resonance imaging techniques. Methods : Seven patients with brain abscesses and ten patients with cystic brain tumors were studied from September 2003 to October 2005. Abscess, subdural empyema and ventriculitis were categorized to the abscess group and cystic or necrotic brain gliomas or metastatic brain tumors into the tumor group. Preoperative magnetic resonance images were performed in all patients and diffusion-weighted images and apparent diffusion coefficiency values of lesions were calculated directly from software of 1.5 tesla MRI [General Electrics, USA]. The ratio of the ADC of the lesion to contralateral regional ADC was also measured [relative ADC, rADC]. Results : The average ADC value of pyogenic abscesses group was $0.82+/-0.14{\times}10^{-3}\;[mean+/-S.D.]\;mm^2/s$ and mean rADC was 0.75. Cystic or necrotic areas had high ADC values [$2.49+/-0.79{\times}10^{-3}\;mm^2/s$, mean rADC=2.14]. ADC and rADC values of abscesses group showed about three times lower values than those of cystic or necrotic tumor group. Conclusion : This study results based on numerical comparison of signal intensities and quantitative analysis to distinguish between brain abscess and cystic or necrotic tumor, DWI and ADC mapping are thought to be very useful diagnostic tools.