• 제목/요약/키워드: Diffusion magnetic resonance

검색결과 354건 처리시간 0.029초

Monitoring Response to Neoadjuvant Chemotherapy of Primary Osteosarcoma Using Diffusion Kurtosis Magnetic Resonance Imaging: Initial Findings

  • Chenglei Liu;Yan Xi;Mei Li;Qiong Jiao;Huizhen Zhang;Qingcheng Yang;Weiwu Yao
    • Korean Journal of Radiology
    • /
    • 제20권5호
    • /
    • pp.801-811
    • /
    • 2019
  • Objective: To determine whether diffusion kurtosis imaging (DKI) is effective in monitoring tumor response to neoadjuvant chemotherapy in patients with osteosarcoma. Materials and Methods: Twenty-nine osteosarcoma patients (20 men and 9 women; mean age, 17.6 ± 7.8 years) who had undergone magnetic resonance imaging (MRI) and DKI before and after neoadjuvant chemotherapy were included. Tumor volume, apparent diffusion coefficient (ADC), mean diffusivity (MD), mean kurtosis (MK), and change ratio (ΔX) between pre-and post-treatment were calculated. Based on histologic response, the patients were divided into those with good response (≥ 90% necrosis, n = 12) and those with poor response (< 90% necrosis, n = 17). Several MRI parameters between the groups were compared using Student's t test. The correlation between image indexes and tumor necrosis was determined using Pearson's correlation, and diagnostic performance was compared using receiver operating characteristic curves. Results: In good responders, MDpost, ADCpost, and MKpost values were significantly higher than in poor responders (p < 0.001, p < 0.001, and p = 0.042, respectively). The ΔMD and ΔADC were also significantly higher in good responders than in poor responders (p < 0.001 and p = 0.01, respectively). However, no significant difference was observed in ΔMK (p = 0.092). MDpost and ΔMD showed high correlations with tumor necrosis rate (r = 0.669 and r = 0.622, respectively), and MDpost had higher diagnostic performance than ADCpost (p = 0.037) and MKpost (p = 0.011). Similarly, ΔMD also showed higher diagnostic performance than ΔADC (p = 0.033) and ΔMK (p = 0.037). Conclusion: MD is a promising biomarker for monitoring tumor response to preoperative chemotherapy in patients with osteosarcoma.

저자장 자기공명영상시스템에서 선주사확산강조영상기법 개발 (Development of the Line Scan Diffusion Weighted Imaging at Low Tesla Magnetic Resonance Imaging System)

  • 홍철표;이동훈;이도완;이만우;백문영;한봉수
    • 한국방사선학회논문지
    • /
    • 제2권2호
    • /
    • pp.31-38
    • /
    • 2008
  • 0.32 T 자기공명영상시스템에서 선주사영상기법(line scan imaging)을 이용한 확산강조영상(diffusion weighted imaging; DWI) 펄스열(pulse sequence)을 개발하였다. 선주사영상은 단면선택 경사자장과 함께 90도 펄스를 가하여 단면을 선택한 후 y 방향으로 경사자장을 가한 후 180도 라디오파 펄스를 가하여 단면영상의 y-방향 픽셀크기와 같은 너비의 x축에 평행한 띠를 따라 에코가 발생하게 한 뒤 x-방향으로 주파수부호화해서 1차원 k-공간 데이터를 획득하며 이를 1차원 푸리에변환하여 영상을 재구성하였다. 또한 선주사확산강조영상(line scan diffusion weighted image)을 위해서 한 쌍의 사다리꼴모양의 경사자장을 선주사영상기법의 180도 펄스 전후에 대칭으로 배치하였으며 사용된 확산경사자장기울기의 최대값은 G = 15 mT/m 이었고 최대 b 값은 $301.50s/mm^2$이었다. 본 연구에서 개발된 선주사확산강조펄스열을 이용하여 0.32 T 자기공명영상 장비에서 트리아실글리세롤 팬텀(triacylglycerol, TAG) 및 염화나트륨 수용액 (NaCl = 0.1w/v%) 팬텀 영상을 획득하였다. 또한 1.5 T 자기공명영상시스템에서 단일여기에코평면영상화(single shot echo planar imaging)로 동일한 팬텀의 확산강조영상을 구하였다. 선주사확산강조영상은 가장 널리 이용되고 있는 에코평면영상을 이용한 확산강조영상과 비교하여 자화율차이에 의한 영상왜곡이나 화학이동에 의한 허상들이 없음을 확인하였다. 특히 선주사확산강조영상에서 측정한 염화나트륨 수용액 팬텀의 확산계수($963.90{\pm}79.83{\times}10^{-6}mm^2/s$)는 1.5 T에서 계산된 확산계수($956.77{\pm}4.12{\times}10^{-6}mm^2/s$)와 오차범위 내에서 일치하였다.

  • PDF

최근 자기공명 의료영상기기의 발전 (Recent Developments in Magnetic Resonance Imaging)

  • 조장희;노용만;정순철;박세혁;문치웅
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 춘계학술대회
    • /
    • pp.9-15
    • /
    • 1994
  • In last few decades, medical imaging techniques have been developed startling progress. Especially in MRI (Magnetic Resonance Imaging), many imaging techniques such as chemical shift imaging, flow imaging, diffusion and perfusion imaging, fast imaging, susceptibility imaging and functional imaging have been studied and many of them were well known as useful diagnostic instruments. In this paper, recently developing techniques, i.e., NMR microscopy, fringe field imaging and functional imaging will be presented.

  • PDF

Solid-state NMR Studies of Miscibility and Morphology in Blends of Bisphenol-A type Polycarbonate and Poly (ester-ether) Elastomer

  • Kim, Yongae
    • 한국자기공명학회논문지
    • /
    • 제5권1호
    • /
    • pp.19-28
    • /
    • 2001
  • Miscibility and morphology in blends of bisphenol-A type polycarbonate and poly (ester-ether) elastomer with different compositions are studied by solid-state NMR spectroscopy. $^{13}$ C Solid-state NMR of CP/MAS/TOSS/DD, CP/MAS/DD, inversion recovery CP/MAS/DD, and 2D rotor driven spin diffusion techniques are used to identify the miscibility, morphology, and transesterification in blends. The blends of PC /BT elastomer with 15% to 42% of soft segment seem to be single phase miscible mixing and those of PC/PBT and PC/PBT elastomer with 62% of soft segment are cocontinuous two phase immiscible mixing. No significant transesterification reactions are observed in blends with different compositions.

  • PDF

Recommendations for the Selective Labeling of [$^{15}N$]-Labeled Amino Acids without Using Auxotrophic Strains

  • Chae, Young-Kee
    • 한국자기공명학회논문지
    • /
    • 제4권2호
    • /
    • pp.133-139
    • /
    • 2000
  • The strategy to incorporate [$^{15}$ N]-labeled amino acids were discussed. Instead of using specific auxotrophic strains for selective labeling, the prototrophic strain, BL2l(DE3), was used with a plasmid, pLysS, and found to be very effective for several amino acids including alanine, lysine, leucine, and threonine. Isoleucine, valine, glutamine, and tyrosine were also found to be effective despite some diffusion into other amino acids. Interesting result was obtained when [$^{15}$ N]-labeled glycine was tried: only glycines were labeled when amino acid mixture was added in the growth medium, and serines were co-labeled when amino acids were omitted. These results can be used as a guideline when selective labeling strategy is considered, and when the resulting data are interpreted.

  • PDF

Structural Analysis and Single-Crystal EPR Study of Dimeric Cu(I) Complex with TTF Derivative

  • Kwon, Sun-Young;Seo, Young-Joo;Lee, Yang-Joo;Noh, Dong-Youn;Lee, Hong-In
    • 한국자기공명학회논문지
    • /
    • 제8권2호
    • /
    • pp.86-95
    • /
    • 2004
  • A Cu(I) complex with an asymmetric TTF derivative (CET-EDTTTF) is prepared from the slow-diffusion method using CET-EDTTTF and Cu(I)Br solutions and characterized by X-ray crystallography and EPR spectroscopy. Structural analysis shows Cu(I) ions are tetrahedrally coordinated to two bridging bromides, one terminal bromide, and one S atom from CET-EDTTTF. Detailed geometrical and EPR analysis identified that the dimmer molecule contains [Cu$_2Br_4]^{2-}$ anion between two [CET-EDTTTF]$^+$ radical cations. Single-crystal EPR investigation of the complex reveals that the ganisotropy is unusually big, compared to those of the previously reported TTF+ cation radicals, implying that there is significant contribution of the Cu d-orbital to the HOMO of the complex.

  • PDF

Multiparametric Functional Magnetic Resonance Imaging for Evaluating Renal Allograft Injury

  • Yuan Meng Yu;Qian Qian Ni;Zhen Jane Wang;Meng Lin Chen;Long Jiang Zhang
    • Korean Journal of Radiology
    • /
    • 제20권6호
    • /
    • pp.894-908
    • /
    • 2019
  • Kidney transplantation is the treatment of choice for patients with end-stage renal disease, as it extends survival and increases quality of life in these patients. However, chronic allograft injury continues to be a major problem, and leads to eventual graft loss. Early detection of allograft injury is essential for guiding appropriate intervention to delay or prevent irreversible damage. Several advanced MRI techniques can offer some important information regarding functional changes such as perfusion, diffusion, structural complexity, as well as oxygenation and fibrosis. This review highlights the potential of multiparametric MRI for noninvasive and comprehensive assessment of renal allograft injury.

The Software Development for Diffusion Tensor Imaging

  • Song, In-Chan;Chang, Kee-Hyun;Han, Moon-Hee
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.112-112
    • /
    • 2001
  • Purpose: We developed the software for diffusion tensor imaging and evaluated its feasibility in norm brains. Method: Five normal volunteers, aged from 25 to 29 years, were examined on a 1.5 T MR system. the diffusion tensor pulse sequence used a SE-EPI with 6 diffusion gradie directions of (1, 1, 0), (-1, 1,0), (1, 0, 1), (-1, 0, 1), (0, 1, 1), (0, 1, -1) and also with no diffusion gradient. A b-factor of 500 sec/mm2 was used. Measurement parameter were as follows; TR/TE=10000 ms/99 ms, FOV=240 mm, matrix=128$\times$128, slice thickness/gap=6 mm/0 mm, bandwidth=91 kHz and the number of total slices=20. Four repeated axial diffusion images were averaged for diffusion tensor imaging. A total scan 11 of 4 min 30 sec was used. Six full diffusion tensor components of Dxx, Dyy, Dzz, Dxy, Dxz and Dyz were obtained using two-point linear regression model from 7 diffusion-weight images at each pixel and fractional anisotropy and lattice index images was estimated fr their eigenvectors and eigenvalues. Our program was written on a platform of IDL. W evaluated the qualities of fractional anisotropy and lattice index images of normal brains a knew whether our software for diffusion tensor imaging may be feasible.

  • PDF

The Principles of Diffusion MR

  • 장용민
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2003년도 제8차 학술대회 초록집
    • /
    • pp.49-53
    • /
    • 2003
  • 확산텐서영상(Diffusion Tensor Imaging)의 개념은 1980년대 중반 확산강조영상(Diffusion Weighted Imaging)의 개념이 도입되면서 거의 동시에 도입되었지만 MR 장비의 기계적 한계등으로 인해 최근에야 임상적으로 사용되기 시작했다. 확산텐서영상(DTI)과 확산강조영상(DWI)의 방법론적인 차이점은 단순히 확산강조영상의 경우 세 개의 다른방향 (X-, Y-, Z-축)으로 확산측정용 경사자장을 가하는 반면 확산텐서영상의 경우 이보다 많은 방향 (최소한 6 방향)으로 확산측정용 경사자장을 가한다는 점이다. 이러한 차이로부터 금방 알 수 있는 점은 확산강조영상은 확산텐서영상의 일부라는 점이다. 즉, 확산텐서영상의 경우 더 많은 방향으로 확산측정용 경사자장을 가했으므로 더 많은 정보를 획득할 수 있고 이중 세 개의 방향 (주로 X,Y,Z)에 대한 정보만을 이용하게 되면 확산강조영상이다. 이러한 이유로 확산텐서영상을 획득하면 확산강조영상에서 얻게 되는 방향별 확산강조영상, 등방성(isotropic) 확산강조영상, ADC (Apparent Diffusion Coefficient) map등도 기본적으로 얻게 되므로 추가로 확산강조영상을 획득할 필요가 없다. 본 강의에서는 이러한 확산(텐서)영상의 물리적 원리를 복잡한 수학적 설명보다는 개념 위주로 설명해 보고자 한다.

  • PDF

핵자기공명 현미영상법을 이용한 약물전달체계의 비파괴연구 (Noninvasive study of Drug Delivery Systems using Nuclear Magnetic Resonance Microimaging)

  • 이동훈;고락길
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권2호
    • /
    • pp.173-178
    • /
    • 1997
  • pH sensitive polymers have long been utilized as one important type among many interesting drug delivery systems. This is due to the reason of different pH environments in human organs, which requires different pH control mechanism depending upon the organs. In the present study the pH sensitivity was investigated for both pH sensitive and pH insensitive biopolymers using the diffusion effect along with the swelling effect. NMR microscopy was performed along with optical microscopy. For the analysis of diffusion effect, UMR Microscopy was perFormed to measure diffusion coefficients for various liquids such as distilled water, acetone and DMSO(dimethyl sulfoxide). Also, this technique is expected to contribute to the studies for many pH drug delivery systems.

  • PDF