• 제목/요약/키워드: Diffusion imaging

검색결과 441건 처리시간 0.037초

Impact of Time Interval between Index Event and Stenting on Periprocedural Risk in Patients with Symptomatic Carotid Stenosis

  • Han, Wonsuck;Hwang, Gyojun;Oh, Sung Han;Lee, Jong Joo;Kim, Mi Kyung;Chung, Bong Sub;Rhim, Jong Kook;Sheen, Seung Hun;Kim, Taehyung
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권5호
    • /
    • pp.598-606
    • /
    • 2020
  • Objective : The purpose of this study was to evaluate the impact of time interval between index event and stenting on the periprocedural risk of stenting for symptomatic carotid stenosis and to determine the optimal timing of stenting. Methods : This retrospective study included 491 (322 symptomatic [65.6%] and 169 asymptomatic [34.4%]) patients undergoing carotid stenting. The symptomatic patients were categorized into Day 0-3, 4-7, 8-10, 11-14, 15-21, and >21 groups according to the time interval between index event and stenting. Periprocedural (≤30 days) risk for clinical (any neurological deterioration) and radiological (new infarction on postprocedural diffusion-weighted imaging) events of stenting in each time interval versus asymptomatic stenosis was calculated with logistic regression analysis adjusted for confounders, and provided as odds ratio (OR) and 95% confidence interval (CI). Results : Overall clinical event rate (4.3%) of stenting for symptomatic carotid stenosis was higher than that for asymptomatic stenosis (1.2%; OR, 3.979 [95% CI, 1.093-14.489]; p=0.036). Stenting in Day 0-3 (13.2%; OR, 10.997 [95% CI, 2.333-51.826]; p=0.002) and Day 4-7 (8.3%; OR, 6.775 [95% CI, 1.382-33.227]; p=0.018) was associated with high risk for clinical events. However, the clinical event rates in stenting after 7 days from index event (Day 8-10, 1.8%; Day 11-14, 2.5%; Day 15-21, 0%; Day >21, 2.9%) were not different from that in stenting for asymptomatic stenosis. Overall radiological event rate (55.6%) in symptomatic stenosis was also higher than that in asymptomatic stenosis (35.5%; OR, 2.274 [95% CI, 1.553-3.352]; p<0.001). The high risk for radiological events was maintained in all time intervals (Day 0-3 : 55.3%; OR, 2.224 [95% CI, 1.103-4.627]; p=0.026; Day 4-7 : 58.3%; OR, 2.543 [95% CI, 1.329-4.949]; p=0.005; Day 8-10 : 53.6%; OR, 2.096 [95% CI, 1.138-3.889]; p=0.018; Day 11-14 : 57.5%; OR, 2.458 [95% CI, 1.225-5.021]; p=0.012; Day 15-21 : 55.6%; OR, 2.271 [95% CI, 1.099-4.764]; p=0.028; Day >21 : 54.8%; OR, 2.203 [95% CI, 1.342-3.641]; p=0.002). Conclusion : This study showed that as stenting was delayed, the periprocedural risk for clinical events decreased. The clinical event risk was high only in stenting within 7 days and comparable with that for asymptomatic stenosis in stenting after 7 days from index event, although the radiological event risk was not affected by stenting timing. Therefore, our results suggest that delayed stenting after 7 days from symptom onset is a safe strategy for symptomatic stenosis.

1.57 BRAIN MRI검사에서의 작동제어모드를 통한 두부 SAR측정과 변화인자에 관한 고찰 (Implementation about measurement of the head SAR and variable parameter according to operation control mode in brain MR study with 1.5Tesia)

  • 이규수;심현;문지훈;오재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.58-60
    • /
    • 2007
  • Magnetic Resonance Imaging(MRI) has become a very widely used medical procedur e. Clo.sed and open systems are typically used with static magnetic fields at or below 2 Tesla. BWhole body SAR(specific absorbsion rate) is the value of SAR averaged over the entire body of the patient over any period of 15 minutes. Head SAR is the value of SAR averaged over the head of the patient for any period of 10 minutes. SAR is a measure of the absorption of electromagnetic energy in the body' (typically in watts per kilogram (W/kg)). The normal operating mode comprises values of head SAR not higher than 3 W/kg. The second level controlled operating mode comprises values higher than 3 W/kg. Current FDA guidance limits the SAR in the whole body. including the head to a range of 1.5 to 4.0 W/kg, depending on the patient's clinical condition. SAR, limit restrictions are incorporated in all MRI systems. and domestic' s guidance limits the SAR in a part body. including the head to 3.2w/kg and less. The purpose of this study is to evaluate on change of head SAR in using MRI pulse sequence and to check if exceed 3.2(w/kg) level in domestic a part exposure through measured head SAR. 23 patient's the average head SAR of pulse sequence is that T2WI sagittal is 0.5375. T2WI axial(FSE) is 0.4817, T1WI axial(SE) is, 0.8179. FLAIR axial is 0.4580. GRE axial is 0.0077, Diffusion is 0.0824w/kg. The head SAR exposed per patient was proved 2.3845w/kg less than the international standard. Coefficient of correlation for the relations body weight and SAR or for the relations ETL(echo train length) and SAR is 1 value. Coefficient of correlation for the relations between TR(time to repeat) and SAR is -0.602 value. so SAR increased relative to weight body and ETL. But the relations between TR and SAR is negative definite.

  • PDF

선형적 위상배열 코일구조의 시뮬레이션을 통한 민감도지도의 공간 해상도 및 필터링 변화에 따른 MR-SENSE 영상재구성 평가 (Evaluation of MR-SENSE Reconstruction by Filtering Effect and Spatial Resolution of the Sensitivity Map for the Simulation-Based Linear Coil Array)

  • 이동훈;홍철표;한봉수;김형진;서재준;김소현;이춘형;이만우
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권3호
    • /
    • pp.245-250
    • /
    • 2011
  • Parallel imaging technique can provide several advantages for a multitude of MRI applications. Especially, in SENSE technique, sensitivity maps were always required in order to determine the reconstruction matrix, therefore, a number of difference approaches using sensitivity information from coils have been demonstrated to improve of image quality. Moreover, many filtering methods were proposed such as adaptive matched filter and nonlinear diffusion technique to optimize the suppression of background noise and to improve of image quality. In this study, we performed SENSE reconstruction using computer simulations to confirm the most suitable method for the feasibility of filtering effect and according to changing order of polynomial fit that were applied on variation of spatial resolution of sensitivity map. The image was obtained at 0.32T(Magfinder II, Genpia, Korea) MRI system using spin-echo pulse sequence(TR/TE = 500/20 ms, FOV = 300 mm, matrix = $128{\times}128$, thickness = 8 mm). For the simulation, obtained image was multiplied with four linear-array coil sensitivities which were formed of 2D-gaussian distribution and the image was complex white gaussian noise was added. Image processing was separated to apply two methods which were polynomial fitting and filtering according to spatial resolution of sensitivity map and each coil image was subsampled corresponding to reduction factor(r-factor) of 2 and 4. The results were compared to mean value of geomety factor(g-factor) and artifact power(AP) according to r-factor 2 and 4. Our results were represented while changing of spatial resolution of sensitivity map and r-factor, polynomial fit methods were represented the better results compared with general filtering methods. Although our result had limitation of computer simulation study instead of applying to experiment and coil geometric array such as linear, our method may be useful for determination of optimal sensitivity map in a linear coil array.

광음향 현미경법을 이용한 반도체 표면의 3차원적 구조 분석 (3-D Analysis of Semiconductor Surface by Using Photoacoustic Microscopy)

  • 이응주;최옥림;임종태;김지웅;최중길
    • 대한화학회지
    • /
    • 제48권6호
    • /
    • pp.553-560
    • /
    • 2004
  • 반도체 제작 과정에서 증착이나 식각, 회로의 검사 등에서 생겨날 수 있는 미세한 흠집이나 불완전성을 검사하기 위해 광음향 현미경법을 응용하였다. 반도체 표면에서 발생되는 광음향 신호를 측정하여 흠집의 형태와 깊이를 결정함으로써 3차원 영상을 분석하여 그 구조를 밝혔다. 또한 광음향 현미경법을 이용하여 진성 GaAs 반도체의 운반자 운송성질(비방사 벌크재결합 및 비방사 표면재결합)과 열확산도 및 시료 깊이에 따른 3차원 영상을 분석하여 진성 GaAs 반도체 열확산도 측정 시, 빛이 조사되는 표면조건에 따라 광음향신호의 주파수 의존성이 달라짐을 관측하였다. 실험결과 표면상태가 거친 면에서 매끄러운 면으로 갈수록 높은 주파수 의존성을 나타내었다. Si 웨이퍼 위에 임의로 제작되어진 흠집을 만들고 이를 광음향 현미경법으로 측정한 결과 광음향 신호는 변조되는 주파수와 웨이퍼의 열적 특성에 따라 달라지며 이를 통하여 흠집의 형태와 위치 및 크기를 확인하였다. 광음향 현미경은 반도체 소자나 세라믹 물질에 대하여 비파괴 검사와 비파괴 평가에 관한 연구가 가능하며 반도체 공정 과정에서 생겨날 수 있는 시료의 깨짐이나 결함 등을 검사하는데 응용 가능한 분석법임이 증명되었다.

초발 조현병, 만성 조현병과 건강 대조군의 뇌활과 분계섬유줄 연결성 비교 (Comparison of Fornix and Stria Terminalis Connectivity among First-Episode Schizophrenia, Chronic Schizophrenia and Healthy Controls)

  • 이아리라;윤미림;육기환;최태규;이강수;방민지;이상혁
    • 생물정신의학
    • /
    • 제26권1호
    • /
    • pp.8-13
    • /
    • 2019
  • Objectives Disrupted integrities of the fornix and stria terminalis have been suggested in schizophrenia. However, very few studies have focused on the fornix and stria terminalis comparing first-episode schizophrenia (FESZ), chronic schizophrenia (CS), and healthy controls (HCs) with the application of diffusion-tensor imaging (DTI) technique. The objective of this study is to compare the connectivity of the fornix and stria terminalis among FESZ, CS, and HCs. Methods We included the 44 FESZ patients, 39 CS patients and 20 HCs in this study. Voxel-wise statistical analysis of the fractional anisotropy (FA) data was performed using Tract-Based Spatial Statistics to analyze the connectivity of fornix and stria terminalis. In addition, the Scale for the Assessment of Positive Symptoms (SAPS) and the Scale for the Assessment of Negative Symptoms (SANS) were used to evaluate clinical symptom severities. Results There were no significant differences between the FESZ, CS, and HCs in age, sex, education years. The SAPS and SANS scores of the schizophrenia groups showed no significant differences. FA values of the right fornix cres/stria terminalis in the CS group were significantly lower than those in FESZ and HCs. There were no significant differences of FA values of the right fornix cres/stria terminalis between the FESZ and the HCs. Pearson correlation analyses revealed that significant correlation between FA values of the right fornix cres/stria terminalies of the the FESZ group and positive, negative symptom scales, and FA values of the right fornix cres/stria terminalis of the CS group and negative symptom scales. Conclusions This study shows that FA values of the fornix and stria terminalis in the CS were lower than in the FESZ and the HCs. These results suggest that the fornix and stria terminalis can play a role in pathophysiology of schizophrenia. Thus current study can broaden our understanding of the pathophysiology of schizophrenia.

소아에서 발생한 COVID-19 연관 급성 괴사성 뇌병증의 MRI 소견: 2건의 증례 보고 및 문헌 고찰 (MRI Findings of COVID-19 Associated Acute Necrotizing Encephalopathy in Two Pediatric Patients: Case Report and Literature Review)

  • 최윤영;이하영;임명관;강영혜
    • 대한영상의학회지
    • /
    • 제85권3호
    • /
    • pp.682-690
    • /
    • 2024
  • 급성 괴사성 뇌병증은 바이러스 감염의 드문 면역 매개 합병증이다. 일반적으로 양쪽 시상을 침범하며, 주로 어린이에서 보고된다. 저자들은 소아에서 발생한 코로나바이러스감염증과 관련된 급성 괴사성 뇌병증 2건을 보고하고자 한다. 7세 여아는 발열과 의식변화, 6세 여아는 발열과 전신성 간질로 내원하였다. 뇌 MRI에서 두 환자 모두 양쪽 시상에 중심부 출혈을 동반한 대칭적인 액체감쇠역전회 고신호강도 병변이 보였고, 한 환자에서는 겉보기확산계수에서 시상에 층상 병변이 보였다. 저자들은 이 보고를 통해 급성 괴사성 뇌병증의 특징적인 뇌 MRI 영상 소견을 인지함으로써 심각한 신경학적 증상을 나타내는 코로나바이러스감염증 환자의 경우 특히 소아에서 영상 소견을 바탕으로 한 빠른 진단이 필요함을 강조하고자 한다. 또한, 급성 괴사성 뇌병증을 시사하는 양측 시상의 출혈성 괴사로 나타났던 코로나바이러스 감염 증례에 대한 문헌을 검토하고자 한다.

황색육아종성 담낭염과 벽비후형 담낭암의 감별진단을 위한 자기공명영상 점수체계의 유용성 (Usefulness of MRI Scoring System for Differential Diagnosis between Xanthogranulomatous Cholecystitis and Wall-Thickening Type Gallbladder Cancer)

  • 한솔;이영환;김유리;소은규
    • 대한영상의학회지
    • /
    • 제85권1호
    • /
    • pp.147-160
    • /
    • 2024
  • 목적 황색육아종성 담낭염을 벽비후형 담낭암으로부터 감별진단하기 위한 자기공명영상(MRI) 점수체계를 고안하고, 그 점수체계의 진단능을 영상의학과 의사의 시각적 평가와 비교하고자 한다. 대상과 방법 복부 MRI 및 수술을 시행한 각각 황색육아종성 담낭염과 벽비후형 담낭암으로 진단된 23명과 35명의 환자를 후향적으로 분석하였다. 세 명의 영상의학과 의사가 모든 MRI 소견을 분석하였다. 저자들은 이러한 MRI 소견을 이용하여 벽비후형 담낭암으로부터 황색육아종성 담낭염을 감별진단하기 위한 점수체계를 고안하였고 이 점수체계의 진단능을 수신자 운영 특성 곡선의 곡선 하 면적을 영상의학과 의사의 시각적 평가와 비교하였다. 결과 9가지의 MRI 소견이 두 질환의 감별에 유의미한 차이를 보였다: 미만형 벽 비후(p < 0.001), 점막 균일성(p = 0.002), 벽내 T2 고신호강호(p < 0.001), 점막 당김(p = 0.016), 담낭 결석(p < 0.001), T1 중등도 혹은 고신호강도(p = 0.033), 확산 제한(p = 0.005), 조영증강 패턴(p < 0.001), 조영증강 최고점 시기(p = 0.008). MRI 점수체계는 곡선 하 면적이 0.972로 뛰어난 진단능을 나타내었고 이는 영상의학과 의사의 시각적 평가보다 유의미하게 높았다. 결론 MRI 점수체계는 황색육아종성 담낭염을 벽비후형 담낭암으로부터 감별진단하는 데 있어 영상의학과 의사의 시각적 평가보다 좋은 진단능을 나타내었다.

뇌 자기공명영상에서 Heavily T2 FLAIR와 DWI 기법의 영상비교 (Image Comparison of Heavily T2 FLAIR and DWI Method in Brain Magnetic Resonance Image)

  • 구은회
    • 방사선산업학회지
    • /
    • 제17권4호
    • /
    • pp.397-403
    • /
    • 2023
  • The purpose of this study is to obtain brain MRI images through Heavenly T2 FLAIR and DWI techniques to find out strengths and weaknesses of each image. Data were analyzed on 13 normal people and 17 brain tumor patients. Philips Ingenia 3.0TCX was used as the equipment used for the inspection, and 32 Channel Head Coil was used to acquire data. Using Image J and Infinity PACS Data, 3mm2 of gray matter, white matter, cerebellum, basal ganglia, and tumor areas were set and measured. Quantitative analysis measured SNR and CNR as an analysis method, and qualitative analysis evaluated overall image quality, lesion conspicuity, image distortion, susceptibility artifact and ghost artifact on a 5-point scale. The statistical significance of data analysis was that Wilcox-on Signed Rank Test and Paired t-test were executed, and the statistical program used was SPSS ver.22.0 and the p value was less than 0.05. In quantitative analysis, the SNR of gray matter, white matter, cerebellum, basal ganglia, and tumor of Heavily T2 FLAIR is 41.45±0.13, 40.52±0.45, 41.44±0.51, 40.96±0.09, 35.28±0.46 and the CNR is 15.24±0.13, 16.75±0.23, 16.28±0.41, 15.83±0.17, 16.63±0.51. In DWI, SNR is 32.58±0.22, 36.75±0.17, 30.21±0.19, 35.83±0.11, 43.29±0.08, and CNR is 13.14±0.63, 14.21±0.31, 12.95±0.32, 11.73±0.09, 17.56±0.52. In normal tissues, Heavenly T2 FLAIR obtained high results, but in disease evaluation, high results were obtained at DWI, b=1000 (p<0.05). In addition, in the qualitative analysis, overall image quality, lesion conspicuity, image distortion, susceptibility artifact and ghost artifact aspects of the Heavily T2 FLAIR were evaluated, and 3.75±0.28, 2.29±0.24, 3.86±0.23, 4.08±0.21, 3.79±0.22 values were found, respectively, and 2.53±0.39, 4.13±0.29, 1.90±0.20, 1.81±0.21, 1.52±0.45 in DWI. As a result of qualitative analysis, overall image quality, image distortion, susceptibility artifact and ghost artifact were rated higher than DWI. However, DWI was evaluated higher in lesion conspicuity (p<0.05). In normal tissues, the level of Heavenly T2 FLAIR was higher, but the DWI technique was higher in the evaluation of the disease (tumor). The two results were necessary techniques depending on the normal site and the location of the disease. In conclusion, statistically significant results were obtained from the two techniques. In quantitative and qualitative analysis, the two techniques had advantages and disadvantages, and in normal and disease evaluation, the two techniques produced useful results. These results are believed to be educational data for clinical basic evaluation and MRI in the future.

초상자성 나노 입자의 자기이완 특성에 관한 이론적 연구 (The Development of Theoretical Model for Relaxation Mechanism of Sup erparamagnetic Nano Particles)

  • 장용민;황문정
    • Investigative Magnetic Resonance Imaging
    • /
    • 제7권1호
    • /
    • pp.39-46
    • /
    • 2003
  • 목적 : 간(liver)과 림프절 특이성 등의 다기능성을 나타내는 미세 초상자성 산화철 입자(ultrasmall superparamagnetic iron oxide: USP IO)의 자기이완(magnetic relaxation)에 대한 이론적 모델을 제시하고 이러한 이론적 모델에 근거한 미세 초상자성 산화철 입자의 자기장의 세기에 따른 자기 이완시간의 변화를 컴퓨터 모의 실험을 통해 연구하였다. 대상 및 방법 : 초상자성 산화철 입자를 조영제로 사용하기 위해서는 생체적합성 고분자로 축약(encapsulation)시키게 되고 따라서 확산(diffusion) 및 전자스핀의 fluctuation 에 기인하여 발생하는 자유 물분자와 간접 상호작용인 "outsphere " 기전에 근거하여 자기이완모델을 개발하였다. 또한 초상자성체의 경우 자기 모멘트가 상자성 입자에 비해 최소 수백배에서 최대 수만배까지 더 크므로 일반적으로 상자성 조영제의 "out sphere" 기전에서 가정하는 저자장 근사치를 사용할 수 없고 따라서 본 연구에서는 Brillouin함수로 표현되는 총자화에 대한 표현을 적용하여 저자장뿐만 아니라 고자장의 경우까지를 모두 포함하는 "out sphere" 기전에 의한 T1 그리고 T2 이완율에 대한 모델을 개발하였다. 이렇게 개발된 자기이완모델을 사용하여 미세 초상자성 산화철 입자의 자기장의 세기에 따른 자기 이완시간의 변화를 symbolic computation tool 인 MathCad(MathCad, USA)를 사용한 컴퓨터 모의 실험을 통해 조사하였다. 결과 : 미세 초상자성 산화철 입자의 T1, T2 자기이완 특성은 먼저, 저자장 영역 (<1.0 Mhz)에서는 이론적 모델의 spectral density function에 들어 있는 두 개의 correlation time중 $\tau$$_{s1}$ 중 (T2의 경우 ${\tau}_{S2}$)이 주된 역할을 하는 것을 알 수 있었고 이는 결과적으로 이러한 나노자성체 입자들이 낮은 자기장하에서는 열적으로 야기된 자기모멘트들의 재배열이 주된 역할을 하는 것으로 해석할 수 있다. 한편 고자장 영역에서는 correlation time 중 $\tau$가 주된 역할을 담당하는데는 $\tau$는 나노 입자의 크기와 연관되어 있으며 고자장에서 입자 크기에 따른 T1 이완율(R1)과 T2 이완율(R2)의 차이는 이러한 입자크기의 차이에 의해 발생하는 것으로 해석할 수 있다. 나노입자에 포함된 철 원자수를 변화시키는 경우 철 원자수가 증가 할 수록 R1과 R2가 증가하는 결과를 나타내었다. 한편 온도변화에 따른 T1, T2 자기이완시간의 변화는 정상체온 근처의 제한적인 온도범위내에서 저자장 영역에서의 아주 작은 변화를 제외하고는 큰 차이를 보이지 않았으나 T1에 비해 T2에서 이러한 변화가 상대적으로 더 작게 나타났다. 결론 : 임상적 다기능성을 나타낼 가능성이 많은 것으로 보고되고 있는 미세 초상자성 산화철 입자의 자기이완에 대한 이론적 모델을 초상자성 나노입자의 물리적 특성에 기초하여 제시하였고 이러한 이론적 모델에 근거한 미세 초상자성 산화철 입자의 자기장의 세기에 따른 자기 이완시간의 변화를 컴퓨터 모의 실험을 통해 조사하였다.다.

  • PDF

유방 자기공명영상법을 이용한 수술 전 관상피내암으로 진단된 환자의 침윤성 유방암을 예측하는 정량적 분석법 (A Method to Quantify Breast MRI for Predicting Tumor Invasion in Patients with Preoperative Biopsy- Proven Ductal Carcinoma in Situ (DCIS))

  • 고명수;김성헌;강봉주;최병길;송병주;차은숙;;김인성
    • Investigative Magnetic Resonance Imaging
    • /
    • 제17권2호
    • /
    • pp.73-82
    • /
    • 2013
  • 목적: 수술전 관상내피암으로 진단된 환자에서 침윤성 유방암을 예측하는 정량적 파라미터를 알아보고자 한다. 대상과 방법: 2009년 1월부터 2010년 3월까지, 조직생검상 관상피내암으로 진단된 41명 환자의 42 자기공명영상을 분석하였다. 정량적 파라미터로는 초기조영증강정도, 최대조영증강 정도, 초기에 빠르면서 최대 조영증강을 보인 시점, 조영증강정도, 동맥기 조영증강비율, 겉보기확산계수, 병변의 지름과 용적을 분석하였다. 정량적 파라미터와 침윤성과 연관관계를 알기 위해 일변량 분석과 다변량 분석을 시행하였다. 결과: 42개의 병변중 23 병변이 침윤성 유방암, 19 병변이 관상피내암으로 확진되었다. 병변의 지름 (p=0.003; $6.5{\pm}3.2$ cm vs. $3.6{\pm}2.6$ cm, respectively)과 조영증강비율 (p=0.036; $1.1{\pm}0.3$ vs. $0.9{\pm}0.3$, respectively)가 통계학적으로 의미있게 침윤성 유방암에서 높게 나왔다. 그외 초기에 빠르면서 최대 조영증강을 보인 시점, 동맥기 조영증강비율, 겉보기 확산계수, 병변의 용적은 침윤성 유방암을 예측하는데 통계학적 의미는 없었다. 결론: 분석한 여러가지 정량적 파라미터 중 병변의 지름과 조영증강비율이 수술전 관상피내암으로 진단된 환자에서 침윤성 유방암을 예측하는데 도움이 된다.