• Title/Summary/Keyword: Diffuser angle

검색결과 103건 처리시간 0.023초

디퓨저 베인 설치각 변화에 따른 R134a 원심압축기 성능 분석 (Performance Analysis of a Centrifugal Compressor for HFC-134a with Variation of Diffuser Vane Angle)

  • 박한영;신유환;이윤표;김광호;정진택;조용훈;김종성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2823-2828
    • /
    • 2007
  • Numerical simulation on the two-stage centrifugal compressor with Low Solidity Vaned Diffuser LSVD) for HFC-134a Turbo-chiller was performed using a commercial code. The comparative study with experimental results from other compressor was also investigated to testify the simulation schemes. The numerical analysis was separately simulated for each stage of the compressor and the effect of impeller-diffuser flow interaction was considered. Setting angle of the diffuser vane changed in the range of 15 deg. and the effects on its variation were discussed in detail including the flow analysis in the passage of the compressor. The vane setting angle obtained from the preliminary design was slightly adjusted to the optimal value by the performance enhancement in terms of pressure recovery and flow characteristics.

  • PDF

유동가시화를 통한 다중 수중익 덕트 내 유속조절에 대한 연구 (Study on Flow Velocity Control of a Multiple Hydrofoil Duct via Flow Visualization Techniques)

  • 김지훈;;원보름;;고진환
    • 한국가시화정보학회지
    • /
    • 제14권2호
    • /
    • pp.12-17
    • /
    • 2016
  • In this work, we investigate the flow velocity controllability of a diffuser-type multiple hydrofoil duct by experimental and numerical flow visualization approaches. The flow velocity controllability is analyzed by changing the angle of the hydrofoil near the outlet, which is the diffuser, while the incoming flow velocity is 0.6 m/s in the experiment. When the diffuser angle is changed from 0 to 7.5 degree, the maximum velocity inside the duct is varied from 1.35 m/s to 1.52 m/s. Also, it is shown from the numerical analysis that the maximum velocity is varied from 1.09 m/s to 1.17 m/s in the same condition. Thus, the aspect of the acceleration in the duct due to the increase of the diffuser angle is similar between the both approaches. Therefore, the multiple hydrofoil duct can be used to control the flow speed inside the duct for continuously extracting power close to a rated capacity.

입.출구 형상변화에 따른 촉매변환기 내의 유동특성에 관한 연구 (A Study on the Fluid Flow Characteristic in Catalytic Converter for Various Inlet and Outlet Header Shapes)

  • 이은호;이철구;유재석;이종화
    • 한국자동차공학회논문집
    • /
    • 제7권7호
    • /
    • pp.187-194
    • /
    • 1999
  • In the design of catalytic converter, velocity distribution is more important than pressure drop because monolith pressure drop is about 80% of overall pressure drop. For the catalytic converter with single diffuser, pressure drop is decreased as the angle of diffuser decrease, but when the angle is below 18$^{\circ}$, the effect is almost negligible . For the catalytic converter with double diffuser, variation of the angle of the first diffuser shows the same trend as the pressure drop while the shape of diffuser gives little influence on that The outlet shape gives negligible effect on the pressure drop and velocity . distribution . Results show that recirculation region of commercial model is aoubt 30% of the total area in the front of monolith. For the catalytic converter with Model 11 that was presented in the study, recirculation region was not detected more uniform velocity distribution was obtained, and pressure drop was also decreased.

  • PDF

수평 화학기상증착 반응기의 입구형상 설계가 단결정 박막증착률 특성에 미치는 영향에 관한 수치적 연구 (Numerical study of the influence of inlet shape design of a horizontal MOCVD reactor on the characteristics of epitaxial layer growth)

  • 정수진;김소정
    • 한국결정성장학회지
    • /
    • 제13권5호
    • /
    • pp.247-253
    • /
    • 2003
  • 본 연구에서는 반응기의 유입 확대부의 형상이 반응기 내의 유동 및 증착특성에 미치는 영향을 연구하기 위하여 수평형 MOCVD 반응기에서 TMGa와 $AsH_3$로부터의 GaAs 증착에 관한 수치적 연구를 수행하였다. 두 개의 기하학적인자(확대각, 확대부 형상)가 증착률, 증착률 균일도. 유속 균일도, 압력강하에 미치는 영향을 연구하였다 웨이퍼 위에서의 증착률 균일도, 평균증착률, 유속 균일도를 고려한 결과, 직선형 확대부의 최적 확대각은 $50^{\circ}$$55^{\circ}$이며 포물선형 확대부의경우, $40^{\circ}$$45^{\circ}$이다. 또한 확대부의 확대각의 변화는 평균증착률 보다 증착률의 균일도에 큰 영향을 미치고 있음을 알 수 있으며 직선확대부보다 포물선형의 확대부에서 더 민감하게 나타남을 알 수 있었다.

다중효용 담수설비용 열압축기의 디퓨져 입구부 형상에 관한 연구 (A Study on the Diffuser Inlet Shape of Thermocompressor for MED Desalination Plant)

  • 김창복;송영호;김경근;박기태;정한식;최두열
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권6호
    • /
    • pp.869-876
    • /
    • 2008
  • A thermocompressor is the equipment which compresses a vapor to a desired discharge pressure. Since it was first used as the evacuation pump for a surface condenser, it has been widely adopted for energy saving systems due to its high working confidence. In the present study, the geometrical analysis of the shape between the jet nozzle and the diffuser inlet, the drag force was calculated by means of the integrated equation of motion and the computational fluid dynamic (CFD) package called FLUENT. The computer simulations were performed to investigate the effects by the various suction flow rates, the distance from jet nozzle outlet to the diffuser inlet and the dimensions of the diffuser inlet section through the iterative calculation. In addition, the results from the CFD analysis on the thermocompressor and the experiments were compared for the verification of the CFD results. In the case of a jet nozzle, the results from the CFD analysis showed a good agreement with the experimental results. Furthermore, in this study, a special attention was paid on the performance of the thermocompressor by varying the diffuser convergence angle of $0.0^{\circ}$, $0.5^{\circ}$, $1.0^{\circ}$, $2.0^{\circ}$, $3.5^{\circ}$ and $4.5^{\circ}$. With the increase of the diffuser convergence angle. the suction capacity was improved up to the degree of $1.0^{\circ}$ while it was decreased over the degree of $1.0^{\circ}$.

Air-Water Two-Phase Flow Performances of Centrifugal Pump with Movable Bladed Impeller and Effects of Installing Diffuser Vanes

  • Sato, Shinji;Furukawa, Akinori
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권3호
    • /
    • pp.245-252
    • /
    • 2010
  • It's known that pump head of centrifugal impeller with lager blade outlet angle is kept higher in air-water two phase flow condition, though the efficiency in water single phase flow condition is inferior. In the present study, a centrifugal impeller with variable blade outlet angles, that has higher efficiencies in both water single phase flow and air-water two phase flow conditions, is proposed. And the performances of the centrifugal impeller with variable blade outlet angles were experimentally investigated in both flow conditions of single and two-phase. In addition, effects of installing diffuser vanes on the performances of centrifugal pump with movable bladed impeller were also examined. The results are as follows: (1) The movable bladed impeller that proposed in this study is effective for higher efficiency in both water single phase and air-water two phase flow conditions. (2) When diffuser vanes are installed, the efficiency of movable bladed impeller decreases particularly at large water flow rate in water single-phase flow condition; (3) The performances of movable bladed impeller are improved by installing of diffuser vanes in air-water two-phase flow condition at relatively small water rate. The improvement by installing of diffuser vanes however disappears at large water flow rate.

디퓨저 깃배치각의 변화에 따른 원심압축기의 공력성능 특성에 관한 수치 연구 (NUMERICAL INVESTIGATION OF THE EFFECT OF THE STAGGER ANGLE ON THE AERODYNAMIC PERFORMANCES IN THE VANED DIFFUSER OF A CENTRIFUGAL COMPRESSOR)

  • 박태규;정인수;정희택;박준영;김세미;백제현
    • 한국전산유체공학회지
    • /
    • 제15권3호
    • /
    • pp.60-65
    • /
    • 2010
  • In the present study, the effects of the stagger angles on the aerodynamic performances in the vaned centrifugal compressor has been investigated by CFD methods. The diffuser vane angles were varied in the range of ${\pm}10$ deg. from the initial-design points. The commercial Navier-Stokes solver, ANSYS-CFX were applied to solve the impeller-diffuser flowfields. Through the numerical results, the desirable setting angles were proposed to fit the best performance to the variation of the operating conditions.

자오면 고정 형상에서 사류펌프 임펠러 및 디퓨져 날개형상 설계 (Blade Shape Design of Mixed-flow Pump Impellers and Diffusers in a Fixed Meridional Geometry)

  • 김성;최영석;이경용
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1203-1208
    • /
    • 2009
  • In this paper, the flow characteristics of the mixed-flow pump impellers and diffusers were numerically predicted by commercial CFD software and DOE(design of experiments). We also discussed how to improve the performance of the mixed-flow pump by designing the impeller and diffuser in the mixed-flow pump. Geometric design variables were defined by the vane plane development which indicates the blade-angle distributions and length of the impeller and the diffusers. Firstly, the design optimization of the defined impeller geometric variables has been done. After that, the flow characteristics were analyzed in the point of incidence angle at the diffuser leading edge for the optimized impeller. Then design of the defined diffuser shape variables has been performed. The reason for the performance improvement was discussed by examining the flow characteristics through the diffuser.

  • PDF

디퓨저 베인각의 변화에 따른 압축기 성능 특성 (Compressor Performance with Variation of Diffuser Vane Inlet Angle)

  • 배명형;신유환;김광호;김진형
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.55-60
    • /
    • 1999
  • A centrifugal compressor was tested with three different diffusers with plate vanes. The vane inlet angle was varied from 15 to 30 dog. The higher static pressure rises are obtained with lower vane stagger angle. In the stable region the static pressure field in vaneless space is very sensitive to flow rate. The impeller has a stabilizing effect over the whole stable operating range. The diffuser has a stabilizing effect at high flow rate but is destabilizing at low flow rate.

  • PDF

사각 천장형 루버 디퓨저의 토출 각도에 따른 실내유동에 관한 연구 (Study on Indoor Flow According to Vane Angle of Square Ceiling Type Louver Diffuser)

  • 장헌덕;이대희;이진호
    • 대한기계학회논문집B
    • /
    • 제36권7호
    • /
    • pp.683-687
    • /
    • 2012
  • 본 연구는 CFD 해석을 이용하여 사각 천장형 루버 디퓨저의 토출각도와 토출 유량에 따른 실내 공기유동 특성에 관한 것이다. CFD 툴은 상용프로그램인 ANSYS 13.0의 CFX를 이용하였다. 연구에 사용된 디퓨저는 적은 유량에서도 충분한 도달거리를 확보할 수 있도록 모델링하였으며, 실내 크기는 $6{\times}6{\times}2.7m$로 디퓨저의 대각선 방향으로 원형 배기구를 모델링 하였다. 토출 공기의 체적유량은 5.1CMM, 7.4CMM이며, 디퓨저의 토출각도를 $30^{\circ}$에서부터 $60^{\circ}$까지 $10^{\circ}$씩 변화하여 실내의 유동특성에 대하여 고찰하였다.