• Title/Summary/Keyword: Diffuser angle

Search Result 103, Processing Time 0.027 seconds

An Experimental Study on the Flow Characteristics of a Swirl-Jet Diffuser (공장환기용 선회 제트 디퓨저의 유동 특성에 관한 실험 연구)

  • Lee, C.S.;Jurng, J.;Jeong, S.Y.;Hong, K.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.2
    • /
    • pp.103-109
    • /
    • 1994
  • An experimental study is performed on the flow characteristics of a swirl-jet diffuser for factory ventilation. Swirl number ranges from 0(nonswirl jet) to 0.6 when the angle of swirl vane is 60 degree. As swirl becomes strong, the maximum velocity in the plane perpendicular to jet axis decreases fast and the uniformity of velocity becomes good, particularly in the ventilated area. The similarity in velocity profiles has been found for axial velocity from even when swirl number equals 0.6. The flow characteristics of the swirl-jet which has the swirl number of 0.6 is thought to be the best among these three swirl numbers for factory ventilation. However, the pressure drop in the diffuser increases as the swirl becomes strong. This should be considered in the design of the total ventilation system including a duct system.

  • PDF

An Experimental Study on Startup Characteristics of a Center Body Diffuser for High Altitude Simulation (고공환경 모사용 Center Body Diffuser의 시동 특성에 관한 실험적 연구)

  • Yeon, Hae In;You, Isang;Kim, Wan Chan;Im, Ji Nyeong;Ko, Young Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.2
    • /
    • pp.93-102
    • /
    • 2016
  • An experimental study has been conducted to verify the startup characteristic of a Center Body Diffuser (CBD) for simulating a low pressure environment when at high altitudes. Vacuum chamber pressure and startup characteristics of the CBD were investigated according to various geometries of the center body structure by a cold gas flow test. The test results show that the startup pressure is lowest when the center body contraction angle is approximately $15^{\circ}$. The startup characteristic of the CBDs significantly improves when the diffuser inlet length ($L_d/D_d$) is decreasing and the divergence length ($L_s$) is increasing. Additionally, it is possible to simulate various high altitude, low pressure conditions for various rocket engines that have different nozzle expansion ratios by adjusting the center body's position inside the diffuser.

Study on the Radial Diffuser of Multistage High Pressure Pump (고압 다단 펌프의 레이디얼 디퓨저에 대한 연구)

  • Kim, Deok Su;Mamatov, Sanjar;Park, Warn Gyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.11
    • /
    • pp.727-736
    • /
    • 2016
  • In this study, a high-pressure multistage pump used in the combined cycle power plants is analyzed. The pump performance characteristics (differential head and efficiency) are numerically analyzed for different shapes of the radial diffuser. The design variables selected for the radial diffuser are, number of vanes, diameter ratio ($D_4/D_3$), return channel outlet angle(${\alpha}_6$), and pressure recovery factor ($C_p$). The numerical analysis results showed that the differential head and efficiency are the highest when the diameter ratio is the highest. Further, it was observed that the differential head was lower when the return channel outlet angle was $60^{\circ}$ than when it was $90^{\circ}$, because of pre-swirl at the diffuser outlet.

Fabrication of a Thermopneumatic Valveless Micropump with Multi-Stacked PDMS Layers

  • Jeong, Ok-Chan;Jeong, Dae-Jung;Yang, Sang-Sik
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.4
    • /
    • pp.137-141
    • /
    • 2004
  • In this paper, a thermopneumatic PMDS (polydimethlysiloxane) micropump with nozzle/diffuser elements is presented. The micropump is composed of nozzle/diffuser elements as dynamic valves, an actuator consisting of a circular PDMS diaphragm and a Cr/Au heater on a glass substrate. Four PDMS layers are used for fabrication of an actuator chamber, actuator diaphragm by a spin coating process, spacer layer, and nozzle/diffuser by the SU-8 molding process. The radius and thickness of the actuator diaphragm is 2 mm and 30 ${\mu}{\textrm}{m}$, respectively. The length and the conical angle of the nozzle/diffuser elements are 3.5 mm and 20$^{\circ}$, respectively. The actuator diaphragm is driven by the air cavity pressure variation caused by ohmic heating and natural cooling. The flow rate of the micropump in the frequency domain is measured for various duty cycles of the square wave input voltage. When the square wave input voltage of 5 V DC is applied to the heater, the maximum flow rate of the micropump is 44.6 ${mu}ell$/min at 100 Hz with a duty ratio of 80% under the zero pressure difference.

Flow Field Change before Onset of Flow Separation

  • Hasegawa, Hiroaki;Sugawara, Takeru
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.3
    • /
    • pp.215-222
    • /
    • 2009
  • Jets issuing through small holes in a wall into a freestream has proven effective in the control of flow separation. This technique is known as the vortex generator jet (VGJs) method. If a precursor signal of separation is found, the separation control system using VGJs can be operated just before the onset of separation and the flow field with no separation is always attained. In this study, we measured the flow field and the wall static pressure in a two-dimensional diffuser to find a precursor signal of flow separation. The streamwise velocity measurements were carried out in the separated shear layer and spectral analysis was applied to the velocity fluctuations at some angles with respect to the diffuser. The pattern of peaks in the spectral analysis changes as the divergence angle increases over the angle of which the whole separation occurs. This change in the spectral pattern is related to the enhancement of the growth of shear layer vortices and appears just before the onset of separation. Therefore, the growth of shear layer vortices can be regarded as a precursor signal to flow separation.

NUMERICAL PREDICTION OF THE OPTIMAL STAGGER ANGLES FOR A HIGH-POWER TURBO BLOWER (고마력 터보 블로어의 최적 깃배치각에 관한 수치 예측)

  • Park, T.G.;Chung, H.T.;Park, J.Y.;Sung, B.I.
    • Journal of computational fluids engineering
    • /
    • v.16 no.3
    • /
    • pp.75-81
    • /
    • 2011
  • The turbo blowers having large power capacity are generally composed of the variable inlet guide vane, the impeller and the variable diffuser. In the present study, the effect of the stagger angles on the aerodynamic performances has been investigated by CFD methods. The design specifications of the reference model having 400kW power were given as 7.43kg/s of mass flow rate, 1.66 of pressure ratio with 12000rpm of impeller rotating speed. As the first simulation parameter, the diffuser vane angle was varied in the range of ${\pm}$20 degree from the initial-design point. The inlet guide vane angles, as the second one, was changed in the range of ${\pm}$40 degree from the initial-design point. The commercial Navier-Stokes solver, ANSYS-CFX, was applied to solve the three-dimensional unsteady flow fields inside the turbo blower. Through the numerical results, the desirable setting angles were proposed to fit the best performance to the variation of the operating conditions.

Optimal Supersonic Diffuser Design of Integrated Rocket Ramjet Engine (IRR형 Ramjet Intake 초음속 확산부 형상 최적설계)

  • 민병영;이재우;변영환
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.6 no.2
    • /
    • pp.65-74
    • /
    • 2002
  • Optimal supersonic diffuser shape of integrated rocket ramjet engine was derived which maximizes the total pressure recovery. Mass flux is considered as a design constraint and the second oblique shock angle of the external ramp, the cowl-lip angle and the throat area are selected as design variables. Refined response surface method through design space transformation technique was developed and employed, and high confidence level of the regression model could be obtained. Genetic algorithm was implemented for both system optimizer and subspace regression model optimization. Virtual nozzle was located at the end of throat to adjust the back pressure. With only 20 aerodynamic analyses, optimal supersonic diffuser shape which has 14% improved total pressure recovery characteristics was successfully designed.

The Influence of the Diffuser Divergence Angle on the Critical Pressure of a Critical Nozzle (디퓨저 확대각이 임계노즐의 임계압력비에 미치는 영향)

  • Kim Jae Hyung;Kim Heuy Dong;Park Kyung Am
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.131-134
    • /
    • 2002
  • Compressible gas flow through a convergent-divergent nozzle is choked at the nozzle throat under a certain critical pressure ratio, and then being no longer dependent on the pressure change in the downstream flow field. In practical, the flow field at the divergent part of the critical nozzle can affect the effective critical pressure ratio. In order to investigate details of flow field through a critical nozzle, the present study solves the axisymmetric, compressible, Wavier-Stokes equations. The diameter of the nozzle throat is D=8.26mm and the half angle of the diffuser is changed between $2^{\circ}\;and\;10^{\circ}$ Computational results are compared with the previous experimental ones. The results obtained show that the divergence angle is significantly influences the critical pressure ratio and the present computations predict the experimented discharge coefficient and critical pressure ratio with a good accuracy. It is also found that a nozzle with the half angle of $4^{\circ}$ nearly predicts the theoretical critical pressure ratio.

  • PDF

Flow characteristics at the Impeller Exit of a Centrifugal Pump (원심펌프의 회전차 출구 유동 특성)

  • Hong, Soon-Sam;Kang, Shin-Hyoulg
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.36-44
    • /
    • 2000
  • The flow at the impeller exit is important to validate engineering design and numerical analysis of pumps. We installed axisymmetric collector instead of the volute casing, so there is no interaction between the impeller and casing. A hot-film probe and a high response pressure transducer are used to investigate the flow at impeller exit and vaneless diffuser region for design and off design flow rate. For a single suction centrifugal pump of low specific speed, the flow field such as velocity, flow angle, and total pressure are measured by traversing the probe across the vaneless diffuser. These data can be used for performance prediction, design, and numerical analysis of pumps.

  • PDF

An Experimental Study on the Flow at the Impeller Exit of a Centrifugal Pump (원심펌프의 회전차 출구 유동에 관한 실험적 연구)

  • Kang, Shin-Hyoung;Hong, Soon-Sam
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.234-241
    • /
    • 1999
  • The flow at the impeller exit is important to validate engineering design and numerical analysis of pumps. However, it is not easy to measure the flow at the impeller exit and evaluate the impeller performance since there is usually strong interaction between the impeller and the volute casing. We installed axisymmetric collector instead of the volute casing, so there is no interaction between the impeller and casing. A 3-hole Cobra probe is used to investigate the flow at impeller exit and vaneless diffuser region for design and on design flow rate. For a single suction centrifugal pump of low specific speed, the flow field such as velocity, flow angle, and total pressure are measured by traversing the probe across the vaneless diffuser. These data can be used for performance prediction, desist and numerical analysis of pumps.

  • PDF