• 제목/요약/키워드: Diffuser Cooling

검색결과 44건 처리시간 0.025초

추적가스를 이용한 바닥취출 공조공간내의 환기효율 측정실험 (Ventilation effectiveness measurements utilizing a tracer gas in an under floor air-conditioning space)

  • 한화택;서세영;김명호;김영일
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.610-618
    • /
    • 1998
  • In this study, a tracer gas technique was used to measure ventilation effectiveness in a thermal environmental chamber simulating an under-floor air conditioning system. A tracer gas of $SF_6$ was injected in a supply duct using step-up and step-down methods. Local mean ages and room mean ages were calculated from the measured concentrations under isothermal and cooling conditions with and without diffusers. Ventilation effectiveness is found to be higher in cooling ventilation operations than in isothermal operations. Results also show that ventilation effectiveness is not significantly affected by a diffuser.

  • PDF

막냉각 홀의 측면 방향 분사각, 확장각 및 주기가 막냉각 효율에 미치는 영향 (Effects of Compound Angle, Diffuser Angle, and Hole Pitch on Film-cooling Effectiveness)

  • 김선민;이기돈;김광용
    • 대한기계학회논문집B
    • /
    • 제35권9호
    • /
    • pp.903-913
    • /
    • 2011
  • 본 연구에서는 가스터빈 블레이드의 냉각을 위해 사용되는 막냉각 홀을 대상으로 다양한 형상변수들이 막냉각 효율에 미치는 영향을 평가하기 위한 수치적 연구를 수행하였다. 삼차원 압축성 Reynolds-averaged Navier-Stokes 해석을 수행하였으며, 난류모델로는 shear stress transport 모델이 사용되었다. 해석을 통해 홀의 형상, 측면 방향 분사각, 홀의 주기 및 분사율이 막냉각 효율에 미치는 영향이 평가되었다. 해석결과, 원통형홀의 경우 측면 방향 분사각이 존재할 때 월등히 향상된 막냉각 효율을 보여주었으며, 홴형상 홀의 경우 측면 방향 분사각이 $20^{\circ}{\sim}30^{\circ}$일 때 가장 높은 막냉각 효율을 보여주었다. 또한 홀의 주기의 변화에 따른 성능평가 결과 높은 분사율일 때가 낮은 분사율의 경우보다 홀의 주기에 의존하는 경향을 보였다.

해군 함정 VRTU의 과열방지를 위한 열전소자 냉각장치의 적용에 따른 기관실 및 VRTU 내부 열 유동특성 분석 (An Analysis of the Thermal Flow Characteristics in Engine-Room and VTRU in accordance with Application of Thermoelectric Device Cooling System to Prevent Overheating of the Korean Navy Ship VRTU)

  • 정영인
    • 한국산학기술학회논문지
    • /
    • 제21권9호
    • /
    • pp.610-616
    • /
    • 2020
  • 본 연구에서는 대한민국 해군 함정의 하절기 운용 및 적도지병 파병 간 발생하고 있는 VRTU 과열로 인한 고온경보 발생과 장비정지 발생현상을 해결하기 위하여 해군 군수사령부 함정기술연구소와 공동연구를 수행하였다. 열전소자 냉각장치 설치에 따른 냉각효과를 확인하고, 전산 열 유동해석을 수행하여 VRTU 내부 열 유동특성을 분석하였다. 또 해석을 통해 기관실(디젤엔진룸) 내부의 온도분포를 살펴보고 VRTU 과열방지를 위한 최적의 설치위치를 알아보았다. 분석결과, 냉각장치를 설치함에 따라 VRTU 내부 평균 체적온도가 약 10 ℃ 감소하는 것을 확인하였으며 냉각장치에 설치된 Fan은 열 순환을 원활하게 하여 냉각효과를 높였다. 기관실 내부는 디젤엔진 상부에서 높은 온도분포를 나타냈고 통풍관 디퓨저 하부에서 가장 낮은 온도분포를 보였다. 열전소자 냉각장치는 높은 냉각성능을 나타내었으며, VRTU는 과열방지를 위하여 기관실의 통풍관 디퓨저 하부에 설치하는 것이 적절할 것으로 판단된다.

고공시험설비에서 로켓엔진의 지상시험 플룸 거동 해석 (An Analysis on Plume Behaviour of Rocket Engine with Ground Condition at High Altitude Engine Test Facility)

  • 김성룡;이승재;한영민
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.112-115
    • /
    • 2017
  • 고공엔진시험설비에서 지상 시험 조건의 시험 가능 여부와 설비 안전 문제를 점검하고자 로켓 엔진 유동을 해석하였다. 진공 챔버를 개방한 상태에서 냉각수를 초음속 디퓨저로 분사하면서 엔진이 작동하는 상황이며, 2차원 축대칭과 플룸, 공기, 냉각수의 3원 혼합물로 가정하였다. 해석 결과 냉각수 유량 200 kg/sec까지 지상 조건 시험이 가능하였다. 그러나 시동 초기 플룸의 역류로 인해 진공 챔버가 고온에 노출되고, 동시에 냉각수 역류로 인해 진공 챔버 내부가 오염되었다. 따라서 충분한 단열 대책과 오염 회피를 위한 작업이 선행되어야 한다.

  • PDF

Effect of Supply and Return Locations of a Floor-Supply Cooling System on Thermal Comfort

  • Kim, Young-Il;Kim, Jo-Seph;Yoo, Ho-Seon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권4호
    • /
    • pp.37-46
    • /
    • 2001
  • This study numerically investigates thermal comfort of a space cooled by a floor-supply air-conditioning system, in which three different combinations of supply and return locations, one floor-supply/ceiling-return and two floor-supply/floor-return, are treated. A complementary experiment is performed to validate the present numerical analysis, and the prediction agrees favorably with the measured data. In the numerical procedure, a simplified model mimicking the inlet flow through a diffuser is developed for efficient simulations. The calculated results show that the ceiling-return type is far better in terms of thermal comfort than the floor-return ones within the extent of this study, which seems to be caused by effective vertical penetration of the supply air against natural convection. It is also revealed that the arrangement of port locations in the floor-supply/floor-return system has insignificant effect on the cooling performance. For selecting a proper system, other characteristics including the heating performance should be accounted for simultaneously with the present considerations.

  • PDF

KSLV-I 킥모터 개발을 위한 고공환경모사시험용 추력측정장치 (Thrust Measurement System for High Altitude Simulation Test of the KSLV-I Kick Motor)

  • 이정호;조상연;조기주;정동호;이한주;오승협;윤경렬;김동철
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.428-431
    • /
    • 2008
  • Korea Aerospace Research Institute(KARI) is achieving the Korea Space Launch Vehicle(KSLV) program according to National Space Technology Development Program. KSLV-I will be composed to liquid propellant(first stage) and solid propellant(second stage) propulsion system. The propulsion system of KSLV-I second stage is solid kick motor with high expansion ratio and its starting altitude is 300km high. In order to verify the performance of upper stage propulsion system designed to operate in the upper atmosphere, test facility which can simulate high altitude is needed. High Altitude Simulation Test Facility is composed to Thrust Measurement System, Control & Measurement system, Diffuser, SKID for cooling water supply to diffuser, CCTV, fire protection system and so on. This paper introduces TMS adapted to High Altitude Simulation Test for KSLV-I Kick Motor Development and results of hot firing test for its performance verification.

  • PDF

화염 정면 가시화를 위한 페리스코프 영상 시스템 설계 및 해석 (Periscope Imaging System Design and Analysis for Flame Front Visualization)

  • 신재익
    • 항공우주시스템공학회지
    • /
    • 제13권5호
    • /
    • pp.16-23
    • /
    • 2019
  • 본 논문은 국방과학연구소 엔진 시험장에 설치된 페리스코프 시스템의 설계 및 해석에 대해 다루고 있다. 페리스코프 시스템은 엔진 후단, 디퓨저 상단에 설치되어 있는 잠망경 모양의 관측 시스템이며 엔진 후단 고온(2300 K)의 연소 생성물 등에 직접적으로 영향을 받아서 파손 위험이 높다. 따라서 1차원 열전달 계산 및 2차원, 3차원 CFD 해석을 통해 열유속 및 정온도 분포를 확인하고 이를 통해 냉각 성능을 검증하였다. 현재의 설계에서 페리스코프 시스템을 통해 화염 형상 및 노즐 제어, 배출 유동의 안정성을 가시적으로 확인 가능하다.

Nb 첨가 오스테나이트계 스테인레스강의 연속주조시 표면크랙 형성기구 및 제어 (Formation Mechanism of Surface Crack and Its Control on Continuously Cast Slabs of Nb-containing Austenitic Stainless Steel)

  • 심상대;김선구
    • 한국주조공학회지
    • /
    • 제21권5호
    • /
    • pp.280-285
    • /
    • 2001
  • Nb-containing austenitic stainless steel is widely used as exhaust frame and diffuser assembly in power plant. However, this steel is known to be difficult to produce by the continuous casting process due to the surface cracks. Therefore, the continuous casting technology was developed for the prevention of the surface cracks on CC slabs. Precipitates and the analysis of heat trasfer in a slab were investigated in order to find out the formation mechanism of surface cracks on cc slabs It was found that surface cracks are occurred due to the NbC precipitates, which are formed along the grain boundaries around $800^{\circ}C$. The secondary cooling pattern has been developed to produce the defect free CC slabs of Nb-containing austenitic stainless steel.

  • PDF

전동차 공조기 덕트 내의 유동특성에 관한 수치해석적 연구 (Numerical study on the flow characteristics in Air-conditioner duct of EMU)

  • 김승택;김성종;박근수;박형순
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.345-350
    • /
    • 2003
  • The inside of EMU is supplied with the cooling air from air-conditioner and the fresh air from exterior through the air-conditioner duct which is one of the air conditioning system. The shape of air-conditioner duct is a major factor in determining the air-conditioning efficiency, thermal comfort and energy efficiency. Therefore, this study is to understand the flow characteristics in the air-conditioner duct by three dimensional numerical simulation. The air-conditioner duct was calculated for the design volume flow rate, $2,726\;m^3/h/unit$. From the result of calculation and measurement, the velocity at diffuser outlet presented good agreement in general. [n this present study, the calculation was also performed for three volume flow rate(1,800, 2,200, 3,000 $m^3/h/unit$) and total pressure characteristic curve with volume flow rate was presented.

  • PDF

초음속 이젝터의 압력회복에 관한 연구 (Pressure Recovery in a supersonic ejector of a high altitude testing chamber)

  • 조지;공창덕
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.833-837
    • /
    • 2010
  • 본 연구는 최소 압력 모사로 엔진 배기가스를 배출시키기 위한 최적 이젝터 크기를 결정하기 위한 것을 목적으로 한다. 실험 챔버로 유입되는 2차 냉각 공기는 유량제어 밸브들과 진공펌프가 장착된 배출구를 통해 엔진배기가스는 분리되어 배출된다. 기존 고도시험 장치와 달리, 본 연구에 제안한 형상은 기존 이젝터의 압력 회복을 개선한 좀 더 작은 포획 면적을 가진 배기 이젝트를 사용하면 가스에 스텔링 챔버로 부터 20% 냉각 공기를 부가하여 배출시키도록 크기가 정해진다. 제안된 형상은 벨마우스 이젝터와 엔진배기 출구의 면적비가 이론적으로 약 1.2를 갖는다. 제안된 형상의 혼합 공기 모사결과에 따르면 큰 에너지는 기존 시스템 비해 좀 더 개선된 압력 회복과 감소된 전력 소모를 같음을 확인하였다.

  • PDF