• 제목/요약/키워드: Diffuse noise field

검색결과 26건 처리시간 0.03초

음원의 지향성이 확산음장 형성에 미치는 영향에 관한 실험연구 (Experimental study for characteristics of diffuse sound field formed by sound source directivity)

  • 신일섭;차광석;조창근;이대우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1002-1006
    • /
    • 2000
  • It is diffuse sound field that measuring condition of absorption ratio and sound transmission loss for material consist of building are measured in reverberartion room and on-site. In this study, for upkeeping diffuse sound field in reverberation room, it is measured and etimated that sound field is effected according to sound source lacation and characteristics of emission directivity for sound source.

  • PDF

축소잔향실의 저주파수 확산음장 형성 방법에 대한 연구 (Study on method of build up low-frequency diffuse sound field in a scaled reverberation chamber)

  • 강준구;강현주;김상렬;최종수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.61-64
    • /
    • 2007
  • This study is dealt with a method to enhance low-frequency diffuse sound field in a scaled reverberation chamber. Because scaled reverberation chamber has not enough room volume, as a result, it shows a few room modes. So it is not build up low-frequency diffuse sound field. A Helmholtz resonator's arrangement is used to improve spatial uniformity of sound pressure at low frequency. The spatial distribution of sound field has been measured before and after control. The standard deviation of sound field has decreased at 315Hz 1/3 Octave band.

  • PDF

수직입사 임피던스를 이용한 난입사 흡음율 예측 연구 (The study on the estimation of diffuse field absorption coefficient by using normal incidence impedance)

  • 유승국;김영찬;김두훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.643-649
    • /
    • 1998
  • This paper is to compare the absorption coefficient with normal incidence waves and it with diffuse incidence waves of glass wool which the most used absorption material and multi layer fiber. The absorption coefficient with normal incidence waves is calculated by surface impedance that measured by using an acoustic tube. Based on this data, the absorption. coefficient with diffuse incidence waves is predicted and is compared with measured the absorption coefficient in reverberation room.

  • PDF

이중판의 차음손실 I (Sound Transmission Loss of Double Panels(I) : A Double Wall with Air Cavity)

  • 강현주;김현실;김재승;김상렬
    • 소음진동
    • /
    • 제7권6호
    • /
    • pp.945-952
    • /
    • 1997
  • This paper shows the feasibility of the suggestion that the angle distribution of incident sound to panels might be gaussian, instead of the conventional uniform distribution in the analysis of transmission loss of panels. To prove the suggestion, the problems with the diffuse sound field in a reverberation room are examined by case studies and the comparision of the prediction with the measurement of sound transmission loss of walls are performed. The results of the comparision show good agreement between the two values.

  • PDF

라디오시티법을 이용한 실내 음향장 해석 연구 (A Study on Room Acoustic Field Analysis using Radiosity Method)

  • 김국현
    • 대한조선학회논문집
    • /
    • 제55권5호
    • /
    • pp.394-400
    • /
    • 2018
  • Various numerical methods have been adopted for indoor noise assessments of ship plant. Acoustical radiosity method is one of the high frequency approaches for acoustic field analysis, which assumes diffuse reflections by boundaries so that it could be efficiently applied to the acoustically diffused indoor space noise analysis. In this study, an acoustic field analysis program has been developed based on radiosity method, which could apply for acoustically large enclosures such as ship's indoor space. For this purpose, the procedure of the acoustical radiosity method has been summarized and implemented to an acoustic field analysis program using MATLAB. Numerical example for a rectangular indoor space has investigated validity of the implemented program. Steady state sound pressure levels calculated for a continuous acoustic source signal have shown good agreement with those by other solutions such as an analytic solution and a ray tracing method. Instantaneous sound pressure levels calculated for an impulsive acoustic signal have provided the clues of direct/reflected acoustic field and reverberation time.

반사 음장을 고려한 음향 확산 구조의 위상 최적 설계 (Topology Optimization of an Acoustic Diffuser Considering Reflected Sound Field)

  • 양지은;이중석;김윤영
    • 한국소음진동공학회논문집
    • /
    • 제23권11호
    • /
    • pp.973-981
    • /
    • 2013
  • The main role of an acoustic diffuser is to diffuse reflected sound field spatially. Since the pioneering work of Schroeder, there have been investigations to improve its performance by using shape/sizing optimization methods. In this paper, a gradient-based topology optimization algorithm is newly presented to find the optimal distribution of reflecting materials for maximizing diffuser performance. Time-harmonic acoustic analysis in a two-dimensional acoustic domain is carried out where the domain is discretized by finite elements. Perfectly matched layers are placed to surround the domain to simulate non-reflecting boundary conditions. Design variables are assigned to each element of which material properties are interpolated between those of air and those of a rigid body. An approach to extract the reflected field from the total acoustic field is employed. To validate the effectiveness of the proposed method, design problems are solved at different frequencies. The performance of the optimized diffusers obtained by the proposed method is compared against that of the conventional Schroeder diffusers.

진동가속도 분석시스템에서 고속푸리에변환을 이용한 기준진동수의 검출 및 감쇠인식 (Detection and Damping Recognition of Normal Frequency Using Fast Fourier Transform in the Vibration Acceleration Analysis System)

  • 김황준
    • 스마트미디어저널
    • /
    • 제8권2호
    • /
    • pp.16-20
    • /
    • 2019
  • 진동가속도 분석시스템에서의 고속푸리에변환은 최근 센서측정 분야에서 활용도가 높아지고 있다. 본문에서 고속푸리에변환은 확산음장의 수많은 진동수유형 중에서 기준진동수를 검출하는 방법을 제안한다. 이 기준진동수는 옥타브중심 진동수와 유사하게 산출하는 진동수감쇠인식을 수식으로 제시하였다. 이 이론을 토대로, 본고는 확산음장의 진동유형에 따라 다르게 감쇠되는 정도를 소음유발자에게 보다 정확하게 알릴 수 있었다.

소형 잔향실의 확산 음장 보정 계수 측정 연구 (The Study on Correction Factor of a Small Scale Reverberation Chamber to Estimate Transmission Loss)

  • 김태민;김다래;김정태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.960-965
    • /
    • 2014
  • Transmission loss of specimen is calculated by measuring energy of incident and transmission and using reverberant room of large size. But normal measurement of transmission loss has trouble because it is actually demanded that large area and specimen of certain size is satisfied with condition of diffused sound field. Especially, in case of mechanical component, interested frequency band is mid-frequency band between 500 ~ 2k Hz, and it is used to be available to minimize a reverberation chamber under conditions satisfying acoustic one because production of specimen for transmission loss measurement has limit. But, as in semi-reverberation room, it is difficult to satisfy condition of diffuse sound field and modification factor is applied to complement that. Correction factor when measuring transmission loss using semi-reverberation chamber is required accuracy because it works as main factor determining reliability of reuslts on transmission loss. In this study, it is analyzed that an effect on correction factor based on varying materials and sizes of specimens in order to deduction of it. Also It is confirmed that applied by elicited correction factor with actual railway vehicle's floor has reliability.

  • PDF

공조시스템 유기 격실 소음 예측 프로그램 개발 (Development of Cabin Noise Prediction Program Induced by HVAC System)

  • 김병희;권종현;조대승
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.554-558
    • /
    • 2004
  • In this paper, we introduce noise prediction program of HVAC system to assist low-noisy design of ship's cabin. The developed program calculates sound power levels at HVAC components considering primary and secondary noise generated by fan and duct element, duct element noise attenuation, and duct break-in noise based on the authentic empirical method suggested by NEBB and acoustic power balancing method. Sound pressure level at cabin with or without ceiling system is evaluated by the diffuse-field theory considering diffuser and duct break-out sound powers. Moreover, the program provides intuitive pre- and post-processors using modem GUI functions to help efficient modeling and evaluation of cabin and HVAC component noise. To validate the accuracy and convenience of the program, noise prediction for a HVAC system is demonstrated.

  • PDF

천장재 차음성능의 실험 평가 (Experimental evaluation of sound Insulation performance of ceiling panels)

  • 강현주;김상렬;김재승;김현실;김봉기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.1067-1070
    • /
    • 2002
  • This paper deals with the factors affecting measurement of sound insulation performance of the ceiling panels. The factors to be experimently examined are as follows: sound diffuseness of the test room by investigating sound pressure distribution, Reverberation time, and influence of speaker location on measured results. Based on the investigation of sound pressure distribution over measuring points, it can draw a conclusion that rectangular shaped rooms as test rooms have a serious problem associated with the diffuse sound field.

  • PDF