• Title/Summary/Keyword: Diffractive

Search Result 129, Processing Time 0.029 seconds

Two-dimensional Laser Drilling Using the Superposition of Orthogonally Polarized Images from Two Computer-generated Holograms

  • Lee, Hwihyeong;Cha, Seongwoo;Ahn, Hee Kyung;Kong, Hong Jin
    • Current Optics and Photonics
    • /
    • v.3 no.5
    • /
    • pp.451-457
    • /
    • 2019
  • Laser processing using holograms can greatly improve processing speed, by spatially distributing the laser energy on the target material. However, it is difficult to reconstruct an image with arrays of closely spaced spots for laser processing, because the specklelike interference pattern prevents the spots from getting close to each other. To resolve this problem, a line target was divided in two, reconstructed with orthogonally polarized beams, and then superposed. Their optical reconstruction was performed by computer-generated holograms and a pulsed laser. With this method, we performed two-dimensional (2D) laser drilling of polyimide film, with a kerf width of $20{\mu}m$ and a total processing length of 20 mm.

Waveguide-type Multidirectional Light Field Display

  • Rah, Hyungju;Lee, Seungmin;Ryu, Yeong Hwa;Park, Gayeon;Song, Seok Ho
    • Current Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.375-380
    • /
    • 2022
  • We demonstrate two types of light field displays based on waveguide grating coupler arrays: a line beam type and a point source type. Ultra violet imprinting of an array of diffractive nanograting cells on the top surface of a 50-㎛-thin slab waveguide can deliver a line beam or a point beam to a multidirectional light field out of the waveguide slab. By controlling the grating vectors of the nanograting cells, the waveguide modes are externally coupled to specific viewing angles to create a multidirectional light field display. Nanograting cells with periods of 300 nm-518 nm and slanted angles of -8.5°~+8.5° are fabricated by two-beam interference lithography on a 40 mm × 40 mm slab waveguide for seven different viewpoints. It is expected that it will be possible to realize a very thin and flexible panel that shows multidirectional light field images through the waveguide-type diffraction display.

Double-Pass System (Optical Quality Analysis System) for Analysis of the Multifocal Function of a Diffractive Multifocal Intraocular Lens (Acrysof ReSTOR®) Compared to a Monofocal Intraocular Lens (Acrysof IQ®)

  • Hwang, Ho Sik;Shin, Hye Young;Joo, Choun-Ki
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.110-117
    • /
    • 2014
  • In this study, we objectively determined whether the ReSTOR as a multifocal IOL (intraocular lens) has a multifocal function compared to the IQ as a monofocal IOL in vivo by OQAS (Optical Quality Analysis System). Eighteen patients who had cataract surgery with implantation of ReSTOR (27 eyes) and 15 patients with IQ (21 eyes), were included inthis study. Uncorrected distance visual acuity (UCDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UCNVA)and distance corrected near visual acuity (DCNVA) were measured. After setting the artificial pupil size to 3 mm, we performed 'Optical quality'. We inputted defocus diopters of (objective spherical refraction)(far), (objective spherical refraction-1.25 D)(intermediate),(objective spherical refraction-2.5 D)(near), and (objective spherical refraction-3.5 D)(very near) into 'selected spherical refraction' simulating the optical quality at far, intermediate, and near distance. We changed the pupil size to 5 mm and repeated the same measurements. The UCDVA and CDVA did not show significant differences between the 2 groups. But, the UCNVA and DCNVA of the ReSTOR group were better than those of the IQ group (p=0.000, p=0.000). For 3 mm pupil, at far distance, modulation transfer function (MTF) cut off and point spread function (PSF) width at 50% of ReSTOR were worse than those of IQ (p=0.039, p=0.020). At intermediate distance, MTF cut off, Strehl ratio and PSF width at 50% of ReSTOR were worse than those of IQ (p=0.001, p=0.001, p=0.000). At near distance, MTF cut off of ReSTOR was worse than that of IQ (p=0.033). At very near distance, MTF cut off and Strehl ratio of ReSTOR were worse than those of IQ (p=0.002, p=0.002), but PSF width at 50% of ReSTOR was better than that of IQ. For 5 mm pupil, most parameters at each distance, there was no significant difference between the 2 groups. Only PSF width at 50% of ReSTOR were worse than those of IQ at intermediate distance (p=0.013). It was impossible to show the multifocal function of ReSTOR compared to the IQ byOQAS.

Studies on Curved Diffractive Optical Elements in EUV (극자외선 영역에서 곡면 DOEs에 관한 연구)

  • Choi, Sung-Eul;Lee, Yong-Woo;Kwon, Myung-Hoi;Kim, Yong-Hoo
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.4
    • /
    • pp.304-312
    • /
    • 2005
  • Field performance of several different types of diffractive optical elements(DOEs) has been carried out. Using Zemax model, we have designed five different types of DOEs, such as transmissive flat-DOE, transmissive curved-DOE, reflective flat-DOE, reflective curved-DOE and parabolic mirror, We have applied two different wavelengths, i.e., 13 m(EUV) and 632.8 nm(visible) to above DOEs. Off_axis dominate aberrations and the diffraction limiting (Rayleigh limit) field angles have been investigated and compared at both wavelengths for each DOE. At diffraction limit, field angle of curved-DOEs was much greater than that of flat-DOEs for both transmission and reflective types. We also showed that dominated off_axis aberration of flat-DOEs was coma, but that of curved-DOEs was mixture of astigmatism and curvature of field. The measured field angle and expected OPD aberrations were well coincided with theoretical ones. Increasing the ratio of field angle with wavelength was more effective in curved-DOEs than flat-DOEs.

Measurement of a Six-degree-of-freedom Dynamic Characteristics using Angle Sensor-Implemented Grating Interferometry (회절격자 간섭계를 이용한 초정밀 스테이지의 6 자유도 운동 특성 측정)

  • Lee, Cha-Bum;Kim, Gyu-Ha;Lee, Sun-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.8
    • /
    • pp.906-912
    • /
    • 2012
  • This paper presents the new method for a six-degree-of-freedom (DOF) motion measurement and those dynamic characterizations in an ultraprecision linear stage using angle sensor-implemented grating interferometry. It consists of a diffractive optical element, a corner cube, four separate two-dimensional position sensitive detectors, four photodiodes and auxiliary optics components. From the previous study, it was confirmed that the proposed optical system could measure a six-DOF motion error in a linear stage. In this article, six-DOF motion dynamic characteristics of the stage were investigated through the step response and with respect to the conditions with a different speed of a slide table. As a result, the natural frequency and damping ratio according to a six-DOF direction was obtained. Also, it was seen that the speed of slide table had an significant effect on a six-DOF displacement motion, especially, X, which was considered as the effect of friction mechanism and local elastic mechanical deformation in a slide guide.

Etching characteristics of holographic grating on chalcogenide As-Ge-Se-S thin films (칼코게나이드 As-Ge-Se-S 박막에서 홀로그래픽 격자의 에칭 특성)

  • Park, Jong-Hwa;Park, Jeong-Il;Na, Sun-Woong;Son, Chul-Ho;Shin, Kyung;Lee, Young-Jong;Chung, Hong-Bay
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.644-647
    • /
    • 2001
  • Amorphous As-Ge-Se-S thin films have been studied with the aim of identifying optimum etching condition which can be used to produce holographic grating structure for use as diffractive optical elements. In this study, holographic gratings have been formed using He-Ne laser(632.8nm), and fabricated by the method of wet etching using NaOH etchant with various concentration(0.26N, 0.33N, 0.40N). The diffraction efficiency was obtained by +1st order intensity of the diffracted beam. The formed grating profiles were observed by atomic force microscope and showed that the expected grating profile could be achieved by controlling the etching time. Over-etching resulted in under-cutting of the grating lines. The highest 1st order diffraction efficiency for these gratings was about 5.05%.

  • PDF

Diffractive characteristics of the photorefractive gratings in $LiNbO_3$:MgO ($LiNbO_3$:MgO 결정에서 광굴절 격자의 회절 특성)

  • 이재철;장지웅;김준태;신승호
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.5
    • /
    • pp.391-395
    • /
    • 1999
  • We present the measurement of the diffraction efficiency and response time of the photorefractive grating recorded in $LiNbO_3$ photorefractive crystal doped with 4%-mole MgO. Two laser sources were used in the experiments; frequency-doubled Q-switched Nd:YAG laser ($\lambda$=532 nm) and cw Ar-ion laser ($\lambda$=514.5 nm). The same optical geometry was also used in both experiments in order to maintain the experimental consistency. Using the two-wave mixing scheme in both experiments we measured the maximum diffraction efficiency in the range of beam intensity of 1.6~100 W/ $\textrm{cm}^2$, and the response times for both cases of recording and erasing. Two sets of results obtained from the experiments are compared and analyzed.

  • PDF

The comparison and the Analysis of the optical performances between the single and the symmetrical double DOE lenses (단매와 대칭 2매로 구성된 DOE 렌즈의 광학성능 비교 및 분석)

  • 이환선;임천석;조재홍
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.3
    • /
    • pp.258-265
    • /
    • 2002
  • In this paper, we design single and symmetrical double lenses with DOE. The specifications are the following : Image area is 4.8 mm $\times$ 3.6 mm, F/# is 2.8 and the overall length (from first lens surface to image plane) is 6.8mm. After comparing the optical performance and characteristic values, we determine that symmetrical double lenses are superior to single lenses. Symmetrical double lenses have the merits of fewer zones, weaker flare, and smaller distortion than single lenses.

High-Quality Stereo Depth Map Generation Using Infrared Pattern Projection

  • Jeong, Jae-Chan;Shin, Hochul;Chang, Jiho;Lim, Eul-Gyun;Choi, Seung Min;Yoon, Kuk-Jin;Cho, Jae-Il
    • ETRI Journal
    • /
    • v.35 no.6
    • /
    • pp.1011-1020
    • /
    • 2013
  • In this paper, we present a method for obtaining a high-quality 3D depth. The advantages of active pattern projection and passive stereo matching are combined and a system is established. A diffractive optical element (DOE) is developed to project the active pattern. Cross guidance (CG) and auto guidance (AG) are proposed to perform the passive stereo matching in a stereo image in which a DOE pattern is projected. When obtaining the image, the CG emits a DOE pattern periodically and consecutively receives the original and pattern images. In addition, stereo matching is performed using these images. The AG projects the DOE pattern continuously. It conducts cost aggregation, and the image is restored through the process of removing the pattern from the pattern image. The ground truth is generated to estimate the optimal parameter among various stereo matching algorithms. Using the ground truth, the optimal parameter is estimated and the cost computation and aggregation algorithm are selected. The depth is calculated and bad-pixel errors make up 4.45% of the non-occlusion area.

Development of a soft X-ray microscopy system for Biological Application (생물의료용 연 X-선 현미경 시스템 개발)

  • Kim, Gyeong-U;Gwon, Yeong-Man;Kim, Gyu-Gyeom;Min, Jong-Hwan;Park, Jeong-Gwon;Im, Jong-Hyeok;Nam, Gi-Yong;Yun, Gwon-Ha;Min, Jin-Yeong
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2005.02a
    • /
    • pp.264-265
    • /
    • 2005
  • In this paper the conceptual design and development of a compact vertical type soft x-ray microscope is described. This x-ray microscope operates in the water window wavelength region(2.3 ${\sim}$ 4.4nm), where natural contrast between carbon(protein) and oxygen(water) allows imaging of unstained biological material their natural, hydrated environment. Until now, operational x-ray microscopes are based on synchrotron radiation sources, which limit their accessibility. Many biologists would benefit from having the x-ray microscope as a tool among other tools in their own laboratory, For this purpose we introduced the compact vertical type soft X-ray microscope with 50 nm resolution for biomedical application. The compact vertical type soft x-ray microscope is based on a laser plasma x-ray source, doubled ellipsoidal condenser reflective optics, diffractive zone plate optics and MCP coupled with CCD to record an x-ray image.

  • PDF