• 제목/요약/키워드: Difficult ground

검색결과 785건 처리시간 0.037초

지중열교환기용 고성능 시멘트 그라우트 개발 (Development of high-performance cement grout for ground heat exchangers)

  • 이동철;양희정;전중규;서신석;최용민
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권1호
    • /
    • pp.10-16
    • /
    • 2011
  • Performance of ground-source heat pumps (GSHPs) is mainly affected by ground heat exchangers which makes up more than 40% of construction cost. Exact construction and grout as backfill are important, because it is difficult to repair after being installed. As grout materials, bentonite grout material and cement material are used In this paper, thermal conductivity according to mix proportion of cement grout has been experimentally studied. Some variables were set to evaluate thermal conductivities according to change in cement content, unit water ratio, mass per volume of fresh mortar, and aggregate types. From the experimental analysis, high performance cement grout has been proposed.

접지선 전류를 시험 전류원으로 활용한 접지저항 측정기법에 관한 연구 (The Measurement of the Grounding Resistance Using the Ground Current of the Distribution System)

  • 강문호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.293-295
    • /
    • 2004
  • Public utilities adopt the grounding rules ; class I, class II, class III and special class III, and install the grounding electrodes in distribution facilities. To keep the safety of the human and the facilities, Public utilities also manage the value of ground resistance in distribution system biennially. At present the Hook-On meter is normally used to measure the ground resistance although it has ${\pm}5[%]$ measuring error and it can not measure the exact value when the current is over 1[A]. In addition it is very difficult to use the fall-of-potential method in distribution system. In this paper we propose the new measurement method using ground current of distribution system as the current source.

  • PDF

배전계통 접지전극의 접지효과 분석 연구 (Comparison the grounding effect of a grounding rods and a grounding copper band in the Distribution System)

  • 강문호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.509-511
    • /
    • 2004
  • Grounding rods as a discharge path are normally used to ensure the safety of human beings and facilities from the over-voltages and the over·current. Each grounding mode class 1, class 2, class 3, special class 4- has prescribed ground resistance values which are kept by the utilities. However, in the distribution system, it is very difficult for grounding rods to obtain the prescribed ground resistance values because of the limits of installation space. Therefore, in this paper, the grounding effects of the grounding copper bands which are recently developed to use efficiently in small area and the grounding rods are compared by testing the ground resistance values, ground potential rise(GPR), and step voltage in various cases.

  • PDF

Tunnelling on terrace soil deposits: Characterization and experiences on the Bogota-Villavicencio road

  • Colmenares, Julio E.;Davila, Juan M.;Shin, Jong-Ho;Vega, Jairo
    • Geomechanics and Engineering
    • /
    • 제15권3호
    • /
    • pp.899-910
    • /
    • 2018
  • Terrace deposits are often encountered in portal areas and tunnels with low overburden. They are challenging to excavate considering their great mechanical and spatial heterogeneity and a very high stiffness contrast within the ground. Terrace deposits are difficult to characterize, considering that samples for laboratory testing are almost unfeasible to obtain, and laboratory tests may not be representative due to scale effects. This paper presents the approach taken for their characterization during the design stage and their posterior validation performed during construction. Lessons learned from several tunnels excavated on terrace deposits on the Bogota-Villavicencio road (central-east Colombia), suggest that based on numerical simulations, laboratory testing and tunnel system behaviour monitoring, an observational approach allows engineers to optimize the excavation and support methods for the encountered ground conditions, resulting in a more economic and safe construction.

방조제 축조에 따른 지반의 변형에 관한 실험연구 (An experimental study on the Ground deformation caused by sea-dike construction)

  • 김성필
    • 한국농공학회지
    • /
    • 제42권5호
    • /
    • pp.78-83
    • /
    • 2000
  • When a sea-dike is constructed on soft soils, it is much difficult to calculate ground deformation caused by forced displacements. In this study , a series of laboratory model tests have been performed to investigate the ground deformation under a constructed sea-dike on soft soils. Construction sequence of sea-dike embankment was assumed such as constructed by quarry first and followed by soils adjacent to quarry embankment. as test data and displacement in subsoils have been analyzed, it seems that deformation is caused by general shear failure. the shape of ground deformation caused by forced displacements was well defined be parabola . Upon comparing profiles and depth of forced displacement from the model test to those based on stress-baring capacity method commonly used, it has been found that deformation prediction using stress-bearing capacity method was not exact at the edge of loading.

  • PDF

컴플라이언트 메커니즘 설계를 위한 바닥 보 구조 기반 조인트 강성 조절법 (Ground Beam Structure Based Joint Stiffness Controlling Method for Compliant Mechanisms)

  • 장강원;김윤영;김명진
    • 대한기계학회논문집A
    • /
    • 제30권10호
    • /
    • pp.1187-1193
    • /
    • 2006
  • Traditionally, the continuum-based topology optimization methods employing the SIMP technique have been used to design compliant mechanisms. Although they have been successful, the optimized mechanisms by the methods are usually difficult to manufacture because of their geometrical complexities. The objective of this study is to develop a topology optimization method that can produce easy-to-fabricate mechanism structure. The proposed method is a ground beam method where beam connectivity is controlled by the beam joint stiffness. In this approach, beam joint stiffness determines the mechanism configuration. Because b the ground structure beams have uniform thicknesses varying only discretely, the resulting mechanism topologies become easily manufacturable.

Polarimetric Parameters Extraction to Understand the Scattering Behavior of NASA/JPL AIRSAR Data

  • Yang, Min-Sil;Moon, Wooil-M.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.442-447
    • /
    • 2002
  • When a SAR system operates in a full-polarimetic mode, the amount of the information one can extract is so complex that the effective presentation of the information is important. However, the information acquired from the polarimetric SAR data is often difficult to interpret by itself, because it is consisted of both the amplitude information and the phase information. Polarimetric parameters are the good way of representing the polarimetric SAR information in a quantitative manner. Also they can characterize the scattering behavior of the ground scatterer. In this research, extraction of polarimetric parameters, evaluation and interpretation of the scattering behavior of the ground with respect to polarimetric SAR signal are carried out. Using the NASA/JPL AIRSAR data, we estimated the polarimetric parameters and compared them in terms of the ground features. In general, extracted parameters well represent the characteristics of the different features on the ground.

  • PDF

Adaptive Beamformer Using Signal Location Information for Satellite

  • Kim, Se-Yen;Hwang, Suk-seung
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제9권4호
    • /
    • pp.379-385
    • /
    • 2020
  • The satellite employs an adaptive beamformer to efficiently detect various signals and to suppress multiple interference signals, simultaneously. Although the adaptive beamforming satellite system needs Angle-of-Arrival (AOA) information of the desired signal, it is difficult to estimate the signal AOAs on the satellite environment. However, the AOA estimation on the ground control tower is more efficient and accurate comparing to the satellite environment. In this paper, we propose an adaptive beamforming satellite system based on the signal location information on the ground, consisting on an angle estimator, an adaptive beamformer, and signal processing & D/B unit. The ground control tower estimates the accurate location of the signal source, and it sends the estimated coordinates of the desired signal to the satellite. The angle estimator mounted on the satellite calculates the desired signal AOA, based on the signal location information transmitted from the ground control center. The satellite beamformer detects the desired signal and suppresses unwanted signals based on the signal AOA calculated by the angle estimator. We provide computer simulation results to present the performance of the proposed satellite adaptive beamforming system based on the signal location information.

도심지 지하굴착 및 정보화 시공 (Urban Excavation and Observational Method)

  • 김학문
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 지반공학 공동 학술발표회
    • /
    • pp.3-14
    • /
    • 2005
  • Reliable predictions of the movement of earth retaining structures and the ground adjacent to braced walls in urban excavation are often difficult due to many variable factors. The ground settlement and the damage of adjacent structures in urban excavation has been an important issue. Therefore, the stability of the adjacent structures must be secured with the excavation support and research on the protection of adjacent structure is necessary. This study showed an urban excavation case and introduce observation method for case of damage behavior in urban excavation.

  • PDF

심층혼합공법의 최저 개량 심도 결정에 관한 해석적 연구 (An Analytical Study on the Determination of the Lowest Improvement Depth of Deep Mixing Method)

  • 박춘식;송지원
    • 한국지반신소재학회논문집
    • /
    • 제19권1호
    • /
    • pp.35-44
    • /
    • 2020
  • 연약지반 개량 공법 중 심층혼합공법에 대한 설계 기법으로는 복합지반으로 해석하는 방법과 말뚝지반으로 해석하는 방법이 있다. 그러나 이러한 해석에 대한 비교 연구는 부족한 실정으로 설계 시 해석 기준을 명확하게 정의 내리는 것에 어려움이 있다. 본 연구에서는 2차원 및 3차원 해석을 통해 성토 높이와 연약지반의 심도, 보강구간의 치환율을 변화시키며 각 조건별로 복합지반과 말뚝지반을 가정하여 해석하였다. 그 결과 최저 개량 심도는 3차원 해석에 비해 2차원 해석 결과가 6.85~9.08% 더 깊은 결과를 도출하였다. 또한 말뚝지반 해석의 경우 복합지반 해석에 비해 개량 심도는 12.22~14.45% 더 깊은 것을 확인하였다. 이 결과를 통하여 보다 정확한 설계를 위해서는 2차원 해석보다는 3차원 해석을 실시해야 하고, 경제적인 설계를 위해서는 복합지반으로 해석해야 하며, 안정적인 설계를 위해서는 말뚝지반 해석을 실시해야 된다고 판단된다.