• 제목/요약/키워드: Differential Mobility Analyzer

검색결과 27건 처리시간 0.026초

화염중 발생하는 SiO$_2$/TiO$_2$/다성분입자의 조성특성에 관한 실험적 연구 (An Experimental Study on Composition Characteristics of SiO$_2$/TiO$_2$/Multicomponent Particle Generated in a Coflow Diffusion Flame)

  • 김태오;서정수;최만수
    • 대한기계학회논문집B
    • /
    • 제25권9호
    • /
    • pp.1175-1182
    • /
    • 2001
  • Chemical compositions of polydisperse SiO$_2$/TiO$_2$multicomponent aggregates were measured for different heights from the burner surface and different mobility diameters of aggregates. SiO$_2$/TiO$_2$multicomponent particles were generated in a hydrogen/oxygen coflow diffusion flame from two sets of precursors: TTIP(titanium tetraisopropoxide), TEOS(tetraethylorthosilicate). To maintain 1:1 mole ratio of TTIP:TEOS vapor, flow rate of carrier gas $N_2$was fixed at 0.6lpm for TTIP, at 0.1lpm for TEOS. In-situ sampling probe was used to supply particles into DMA(differential mobility analyzer) which was calibrated with using commercial DMA(TSI, model 3071A) and classifying monodisperse multicomponent particles. Classified monodisperse particles were collected with electrophoretic collector. The distributions of composition from particles to particle were determined using EDS(energy dispersive spectrometry) coupled with TEM(transmission electron microscope). The chemical(atomic) compositions of classified monodisperse particle were obtained for different heights; z=40mm, 60mm, 80mm. The results suggested that the chemical(atomic) composition of SiO$_2$decreased with the height from burner surface and the composition of SiO$_2$and TiO$_2$approached to the value of 1 to 1 fat downstream. It is also found that the composition of SiO$_2$decreases as the mobility diameter of aggregate increases.

화염중 발생하는 $SiO_2/TiO_2$ 다성분입자의 조성특성에 관한 실험적 연구 (An Experimental Study on Composition Characteristics of $SiO_2/TiO_2$ Multicomponent Particle in Coflow Diffusion Flame)

  • 김태오;서정수;최만수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.441-446
    • /
    • 2000
  • Chemical compositions of monodisperse $SiO_2/TiO_2$ multicomponent aggregates were measured for different heights from the burner surface and different mobility diameters of aggregates. $SiO_2/TiO_2$ multicomponent particles were generated in a hydrogen/oxygen coflow diffusion flame from two sets of precursors: TTIP (titanium tetraisopropoxide), TEOS(tetraethylorthosilicate). To maintain 1:1 mole ratio of TTIP:TEOS vapor theoretically, flow rate of carrier gas $N_2$ was fixed at 0.61pm for TTIP, at 0.11pm for TEOS. In situ sampling probe was used to supply particles into differential mobility analyzer(DMA) which was calibrated with using commercial DMA(TSI 3071A) and classifying monodisperse multicomponent particles. Classified particles were collected with electrophoretic collector. The distributions of composition from particle to particle were determined using EDS (energy dispersive spectrometry) coupled with TEM (transmission electron microscope). The chemical (atomic) compositions of classified monodisperse particle were obtained for different heights; z=40mm, 60mm, 80mm. The results suggested that the atomic composition of $SiO_2$ decreased with the height from burner surface and the composition of $SiO_2$ and $TiO_2$ approached to the value of 1 to 1 in far downstream. It is also found that the composition of $SiO_2$ decreases as the mobility diameter of aggregate increases.

  • PDF

단일 노즐 및 멀티-노즐 가상 임팩터의 성능평가 (Performance Evaluation on Single Nozzle and Multi-Nozzle Virtual Impactors)

  • 김대성;김민철;이규원
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2000년도 추계학술대회 논문집
    • /
    • pp.59-60
    • /
    • 2000
  • 에어로졸을 분리할 수 있는 장비로는 전기적 이동차 분석기(differential mobility analyzer), 싸이클론(cyclone), 습식 충돌기(impinger), 습식 싸이클론(wet cyclone), 확산 배터리(diffusion battery), 관성 임팩터(inertial impactor), 그리고 가상 임팩터(virtual impactor) 등이 있다. 이중 가상 임팩터는 설계 및 제작이 비교적 간편하고, 입자를 분리 및 농축하는데도 좋은 성능을 나타냄으로 널리 사용되어져 왔다. (중략)

  • PDF

저압공정 중 발생하는 나노입자 실시간 측정장비에 관한 연구 (Study on the real-time measurement equipment for nanoparticle in low-pressure processes)

  • 나정길;조대근;최재붕;김영진;김태성
    • 한국진공학회지
    • /
    • 제16권6호
    • /
    • pp.468-473
    • /
    • 2007
  • 본 논문에서는 저압환경에서 실시간으로 나노입자를 측정할 수 있는 PBMS(Particle Beam Mass Spectrometer)의 개발에 대해 서술하였다. 개발된 PBMS의 교정을 위해 NaCl입자를 사용하였다. DMA(Differential Mobility Analyzer)를 통해 +1가로 하전된입자를 1 lpm 발생시켜 그 중 0.086 lpm을 PBMS 입구의 오리피스를 통해 분기하여 유입시켰다. DMA와 PBMS의 전류값을 비교하여 전송효율을 측정한 결과 입자의 크기에 따라 약 50$\sim$60%를 나타내었다. 또한 DMA에서 특정한 크기의 입자를 발생시켜 PBMS로 측정하였으며 그 결과는 입자크기별 농도분포와 잘 일치함을 확인할 수 있었다.

The Influence of Aerosol Source Region on Size-resolved Hygroscopicity During the Asian Pacific Regional Aerosol Characterization Experiment (ACE-Asia) Campaign

  • Lee, Yong-Seob
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제22권E1호
    • /
    • pp.9-18
    • /
    • 2006
  • Aerosol hygroscopic properties were measured by a tandem differential mobility analyzer (TDMA) system during the Aerosol Characterization Experiment (ACE)-Asia campaign from 31 March to 1 May 2001. Two high flow differential mobility analyzers (DMAs) were used to maximize the count rate on board the Center for Interdisciplinary Remotely Piloted Aircraft (CIRPAS) Twin Otter aircraft. Hygroscopic growth factor distributions of particles having initial dry nanoparticle diameters of 0.040, 0.059, 0.086, 0.126, 0.186, 0.273, 0.400, and $0.586{\mu}m$ were measured during 19 research flights. Data collected during 12 of those flights were used to investigate aerosol mixing state and the influence of aerosol source region on size-resolved hygroscopicity. The uniformity in size-resolved hygroscopicity was quantified to facilitate comparison between measurements made in different air masses. Hygroscopic growth factors are strongly dependent on source region and sizes. Mean hygroscopic growth factors were observed to be greatest when the air mass origin was from the south. The mean growth factors for continental sources decreased with initial size from 1.47 to 1.27 for $0.040{\mu}m\;and\;0.586{\mu}m$, but increased with initial size from 1.44 to 1.8 for $0.040{\mu}m\;and\;0.400{\mu}m$ dry diameters for marine sources.

Hy-SMPS의 개발 및 성능평가 (Development and Evaluation of Hy-SMPS)

  • 이홍규;은희람;이건호;안강호
    • 한국입자에어로졸학회지
    • /
    • 제11권2호
    • /
    • pp.57-61
    • /
    • 2015
  • Atmospheric nano-particles along the altitude is one of the main factors causing severe weather phenomena. It is a challenge to find the precise particle size distribution. One useful instrument includes a scanning mobility particle sizer (SMPS). This measures the size distribution of submicron aerosols. The SMPS consists of a condensation particle counter (CPC), differential mobility analyzer (DMA), high voltage power supplier (HVPS), and neutralizer. Due to the many components, it is difficult to install a commercial SMPS into a tethered balloon package system (Eun, 2011). In this study, we customized a SMPS for the tethered balloon package system called Hy-SMPS. It is portable, compact in structure, and evaluated by TSI SMPS using mono and poly-dispersed particles.

SMPS(Scanning Mobility Particle Sizer)를 이용한 안산지역 대기중 초미세입자(30\~500nm) 분포연구 (Monitoring of Airborne Fine Particle using SMPS in Ansan Area)

  • 김용민;안강호
    • 한국대기환경학회지
    • /
    • 제21권3호
    • /
    • pp.295-301
    • /
    • 2005
  • The fine particles in the range of $30\~500nm$ are monitored at Hanyang University campus in Ansan using house made DMA (differential mobility analyzer) and commercial CPC (condensation particle counter, TSI inc.) in SMPS mode. The monitoring period is March 16th 2004 through May 7th, 2004. During the monitoring period, Aitken nuclei mode $(30\~100nm)$ particle concentration has a tendency of increase in the morning and evening hours. However, the accumulation mode $(100\~500nm)$ particle concentration stays rather stable than that of Aitken mode.

입자 측정방법을 통한 초기 수트입자 연구 (Study of Incipient Soot Particles with Measuring Methodologies)

  • 이의주
    • 한국가시화정보학회지
    • /
    • 제2권1호
    • /
    • pp.12-17
    • /
    • 2004
  • The physical characteristics of soot near the soot inception point were investigated with various measurements. In-situ measurements of particle size and volume fraction were introduced based on time resolved laser-induced incandescence (TIRE-LII) and laser-induced ion mobility (LIIM). The one has more convenience and accuracy than conventional LII technique and the other works best for particle sizes of a few nanometers at high concentrations in a uniform concentration field. A complementary ex-situ measurement of particle size is nano differential mobility analyzer (Nano-DMA), which recently developed for measuring particle sizes between 2nm and 100nm and provides high-resolution size information for early soot. Particles will be also collected on transmission electron microscope (TEM) grids using rapid thermophoretic sampling and analyzed for morphology. These measurements will allow fresh and original insight into the characterizing soot inception process. The measured physical properties of incipient soot will clarify the controlling growth mechanism combined with chemical ones, and the dominant mechanism for soot modeling can be deduced from the information.

  • PDF

비구형 입자의 형상에 따른 단극 확산 하전 특성 (Effects of Particle Shapes on Unipolar Diffusion Charging of Non-Spherical Particles)

  • 오현철;박형호;김상수
    • 대한기계학회논문집B
    • /
    • 제28권5호
    • /
    • pp.501-509
    • /
    • 2004
  • Unipolar diffusion charging of non-spherical particles was investigated for various particle shapes. We researched with TiO$_2$agglomerates produced by the thermal decomposition of titanium tetraisopropoxide (TTIP) vapor. TTIP was converted into TiO$_2$, in the furnace reactor and was subsequently introduced into the sintering furnace. Increasing the temperature in the sintering furnace, aggregates were restructured into higher fractal dimensions. The aggregates were classified according to their mobility using a differential mobility analyzer. The projection area and the mass fractal dimension of particles were measured with an image processing technique performed by using transmission electron microscope (TEM) photograph. The selected aggregates were charged by the indirect photoelectric-charger and the average number of charges per particle was measured by an aerosol electrometer and a condensation particle counter. For the particles of same mobility diameter, our results showed that the particle charge quantity decreases as the sintering temperature increases. This result is understandable because particles with lower fractal dimension have larger capacitance and geometric surface area.

VACES을 이용한 대기 중 입자상물질의 농축기술 및 특성 연구 (Characteristics of Aerosol Particle Concentration by the Versatile Aerosol Concentration Enrichment System (VACES))

  • 박정호
    • 한국환경과학회지
    • /
    • 제21권11호
    • /
    • pp.1339-1348
    • /
    • 2012
  • The versatile aerosol concentration enrichment system (VACES) have proven useful for providing elevated levels of atmospheric aerosol to human and animal exposures. In this study, we describe a VACES and tests conducted to both optimize the enhancement factor (EF) and characterize how it depends on experiment conditions. Particle number concentrations were measured from upstream and downstream of the system by scanning mobility particle sizer (SMPS) with a long differential mobility analyzer (DMA) in combination with a condensation particle counter (CPC). SMPS was used for to determine VACES particle EF. Particle EF tends to increase for higher the saturator temperature ($T_{Sat}$) and lower the condenser temperature ($T_{Con}$). $T_{Con}$ higher than $0^{\circ}C$ and $T_{Sat}$ lower than $50^{\circ}C$ was the best to obtain the most increase in particle concentration. Correlation analysis of EF with factor variables of $T_{Sat}$ and $T_{Con}$ resulted in correlation 0.662 and 0.416, respectively. With all five predictor variables included in a multiple regression model, the EF had a liner correlation with $R^2=0.643$.