• Title/Summary/Keyword: Different sources

Search Result 3,408, Processing Time 0.034 seconds

Chandra Archival Survey of Galaxy Clusters: X-ray Point Sources in Cool-core and Non-cool-core Clusters

  • Kim, Minsun;Kim, Eunhyeuk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.78.1-78.1
    • /
    • 2012
  • We have studied the physical properties of X-ray point sources in galaxy clusters using ~600 Chandra archival observations. The goal of this study is to investigate the density environmental effects on the physical properties of X-ray point sources by comparing the properties of X-ray point sources in galaxy clusters to those in typical blank fields. In this presentation, we show the nature of X-ray point sources which are expected to be related with galaxy clusters with different core properties. Using ~60 galaxy clusters observed with Chandra, we investigate the physical properties of X-ray point sources in cool-core and non-cool-core clusters. The cool-core clusters are known to have short central cooling time, and are characterized by low central entropy, systematic central temperature drops, and a brightest cluster galaxy at the X-ray peak. While the non-cool-core clusters have longer central cooling time, and are characterized by large central entropies and flat or centrally rising temperature profile. We show that how central core properties of galaxy clusters affect on the physical properties of X-ray point sources.

  • PDF

Effects of Correlated Color Temperature of LED Light Sources and a Flourescent Light Source on Visual Performance (LED광원과 형광광원의 상관색온도가 시작업 성능에 미치는 영향)

  • Baik, Seung-Heon;Jeong, In-Young;Shin, Hwa-Young;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.18-26
    • /
    • 2009
  • Recently, from an environmental conservative point of view, the need of high-efficiency lighting system, using LED(Light Emitting Diode) light sources have been increased. However, applied LED light sources without regard to its color and pattern provide visual discomfort to occupant. The objective of this study is not only to evaluate the performance of task work under different correlated color temperature condition, but also furnish the preliminary data as concerning its purpose and user of inner space. For the purpose of this study, two types of LED light sources and a fluorescent light source were selected. Thirty undergraduate students served as the participants. Two different task work sheets were conducted to evaluate the accuracy and duration of time. Results from subjective performance, task work of error modification showed that LED light sources were 2.5[%] higher in accuracy with 17.1[%] lower duration than a fluorescent light source. In the case of reading task work, It is presented 20.6[%] decrease with the LED light sources comparison with a fluorescent light source.

Characteristic of BTEX Concentration Ratio of VOC Emission Sources and Ambient Air in Daegu (대구지역 환경대기 및 VOC 발생원의 BTEX 농도비 특성)

  • Choi, Sung-Woo
    • Journal of Environmental Science International
    • /
    • v.16 no.4
    • /
    • pp.415-423
    • /
    • 2007
  • This study assessed the characteristic of BTEX (Benzene, Toluene, Ethylbenzene, Xylene) concentration ratios of industrial emission sources and the neighborhoods of industrial area, fuel such as gasoline, light oil, LPG, and similar gasoline, and ambient air in Daegu. The BTEX in aromatic compounds was the most abundant VOC in Daegu. The BTEX ratios were (0.2:2.6:1.0:1.8) for the neighborhoods of industrial area, (2.6:11.3:1.0:1.2) for residential area, (2.2:11.0:1.0:1.6) for commercial area, (1.0:14.9:1.0:1.3) for industrial area, and (0.2:2.6:1.0:1.8) for the neighborhoods of industrial area. Average BTEX ratios in Daegu were B/T ratio (0.1), B/EB ratio (1.5), B/X ratio (1.1), T/EB ratio (12.6), T/X ratio (10), EB/X ratio (0.7), Expecially, B/T ratio in Daegu was similar as the other cities, Bangkok, Manila, and Hongkong. Comparing other cities with B/T ratio, the main sources of VOC were vehicular exhaust and emission of industrial facilities. Furthermore, BTEX correlation were evaluated at the emission sources and regional areas. Results showed that correlation coefficient values of emission sources, fuels and neighborhood of industry were significant magnitude above 0.65(p<0.01). Also, there showed highly significant correlations among BTEX. Calculated correlation coefficients of ambient air sampling sites were $0.61{\sim}0.954$ for commercial /residential area and $0.613{\sim}0.998$ for industrial area. However, they showed different correlation between commercial/residental area and industrial area. It implied that the emission sources were different from each area.

A Comparison between Wet-only and Bulk Deposition at Two Forest Sites in Japan

  • Imamura, Naohiro;Iwai, Noriko;Tanaka, Nobuaki;Ohte, Nobuhito
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.1
    • /
    • pp.67-77
    • /
    • 2018
  • To investigate the effects of forest and the surrounding natural and anthropogenic sources on the bulk depositions on forested land, this study examined differences in ion concentrations between wet-only and bulk samples at two forested sites in Japan. The surrounding natural and anthropogenic sources at each site were different; Shirasaka is in a rural area and Tanashi is an urban environment. The volume weighted (vw) mean concentrations of $K^+$ and $Ca^{2+}$ in the bulk samples were significantly (p<0.05) higher than those in the wet-only samples at both sites. The forest canopy and a nearby incineration plant were hypothesized to be the main sources of $K^+$ contaminants at Shirasaka and Tanashi, respectively. The transport of sea salt and urban dust may explain the presence of enriched $Ca^{2+}$ concentrations in the bulk samples at Shirasaka and Tanashi, respectively. The $NH_4{^+}$ concentrations in the Shirasaka bulk samples were significantly (p<0.05) lower than those in the wet-only samples. The vw mean $SO{_4}^{2-}$ and $NO_3{^-}$ concentrations in both sample types were not significantly different at either site. This study demonstrated that the ion concentration differences between wet-only and bulk samples were affected by nearby natural and anthropogenic sources even at forest sites, similar to previous findings for non-forested locations. However, the $K^+$ concentration differences between wet-only and bulk samples may be higher owing to forest sources, even in the absence of anthropogenic sources.

A Study on the Drinking Water Quality and Contamination Sources in a Rural Area (일부 농촌지역의 오염원 현황과 먹는 물 수질에 관한 조사연구)

  • 김탁수;이용미;김문선;김성연;신해철;최경호;정문호
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.2
    • /
    • pp.98-103
    • /
    • 2004
  • To evaluate the quality of drinking water and contamination sources in a rural community, this study was carried out on the summer of 2003 at Shin-Dong Myun, Chun-Cheon, Gang-Won province. Seventy three drinking water samples were collected from three different types of water supply systems. Sources of contamination were identified and the public perception of water quality area were evaluated. The findings of this study are as follows; Drinking water was mainly obtained from Local Water and Simple Piped Water Supply Systems, and pollution sources varied over the study area. Most of residents (>63%) were satisfied with the quality of drinking water and could not identify any contamination sources. Corresponding to this perception, measured water quality parameters generally met the Drinking Water Quality Standards (>64%). However, approximately 35.6% of samples exceeded the regulation for Nㅒ$_3$$^{-}$$_{-}$N, coliform, and general bacteria. The water quality was significantly different among the three water supply systems, and between the potentially contaminated areas and the rest of the areas (p<0.05). In the potentially contaminated areas, the levels of coliform and general bacteria contamination were significantly higher than the rest of the areas (p<0.05). The coliform and general bacteria values of Simple Piped Water were significantly higher than Own Piped Water's, and the NO$_3$$^{-}$$_{-}$N values of Own Piped Water were significantly higher than those of water's (p<0.05). Based on this study, NO$_3$$^{-}$$_{-}$N, coliform, and general bacteria were identified as a major problem of drinking water. To regularly manage drinking water supply systems, to identify contamination sources, and to add drainage systems are required in the study area.

Growth and Flowering Responses of Petunia to Various Artificial Light Sources with Different Light Qualities

  • Park, In Sook;Cho, Kyung Jin;Kim, Jiseon;Cho, Ji Yoon;Lim, Tae Jo;Oh, Wook
    • Horticultural Science & Technology
    • /
    • v.34 no.1
    • /
    • pp.55-66
    • /
    • 2016
  • This study was carried out to investigate the effect of artificial light sources with different light qualities on the growth and flowering characteristics of a herbaceous long-day plant, Petunia ${\times}$ hybrida Hort. Seedlings of petunia cultivar 'Madness Rose' were potted, acclimated for one week, and grown in a phytotron equipped with tube- and bulb-type fluorescent lamps (FL tube and bulb), tube-type white light-emitting diodes (LED tube), halogen lamps (HL), metal halide lamps (MH), and high pressure sodium lamps (HPS) for 10 weeks. The temperature, photoperiod, and photosynthetic photon flux density (PPFD) in the phytotron were $22{\pm}2^{\circ}C$, 16 h, and $25{\pm}2{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, respectively. Light sources combined with HL promoted stem elongation, and plant height and internode length decreased with increasing red to far-red (R:FR) ratio. FL tube + LED tube, HPS, and FL tube promoted branching, whereas plants grown under light sources combined with HL did not have any branches. Days to flowering (from longest to shortest) occurred as follows: FL tube + HL > FL tube + HL > MH > HPS = FL tube + FL bulb > FL tube + LED tube > LED tube > FL tube, indicating that reducing the R:FR ratio of the light sources promoted flowering. Only 20% of plants grown under an FL tube flowered, whereas under all other treatments, 100% of plants flowered. At 10 weeks after treatment, plants grown under HPS and MH had (cumulatively) 12 open flowers, and those grown under FL tube + FL bulb, LED tube, FL tube + LED tube, and HPS treatment had approximately seven flower buds. These results suggest that light sources with low R:FR ratios promote flowering and stem elongation in petunia, but they reduce its ornamental value due to overgrowth and poor branching.

The Emission Characteristics of Reduced Sulfur Compounds in the Ban Wall Industrial Complex (반월공단의 대기배출시설을 대상으로 한 악취성 황화합물의 측정과 배출특성에 대한 연구)

  • Choi, Y.J.;Jeon, E.C.;Kim, K.H.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.5
    • /
    • pp.515-524
    • /
    • 2005
  • In this study, the concentrations of major reduced sulfur compounds (RSC: $H_{2}S,\;CH_{3}SH$, DMS, $CS_2$ and DMDS) were determined from various emission sources of individual companies located within the Ban Wal industrial complex of Ansan city, Korea. We investigated the emission concentration levels of RSC from a total of 47 individual companies during June 2004 to January 2005. The results of our study indicate that the emission concentration levels of RSC vary in a highly complicated manner in relation with industrial sectors and emission source types. It was found that both $H_{2}S\;and\;CH_{3}SH$ make the highest contribution to nuisance in the leather industry. Likewise, DMS showed its maximum contribution from food production sector, while DMDS for chemical production sector. When the emission data sets were compared between different emission sources, regardless of industrial types or activities, $H_{2}S\;and\;CH_{3}SH$ concentrations were seen most significant at waste treatment process. The overall results of our study suggest that the emission concentrations of sulfur compounds can be used to distinguish different sources of malodor released by different industrial activities.

Effects of Dietary Supplemental Phosphate from Different Sources on Performance of Young Broiler Chicks and It's Biological Availability (서로 다른 인 공급원들의 생물학적 이용율과 어린 육계의 능력에 미치는 영향)

  • 류경선
    • Korean Journal of Poultry Science
    • /
    • v.23 no.4
    • /
    • pp.169-175
    • /
    • 1996
  • An experiment was conducted with male broiler chicks to determine the effect of different dietary phosphorus sources and evaluate the biological availability of phosphorus sources. The biological availability of phosphorus from dicalcium phosphate (DCP) was used as a reference standard (100%) compared to defluorinate phosphate (DFP). DCP and DFP was supplemented to a corn-soy basal diet at levels of 0.05, 0.15, 0.25, 0.35%. Each of 24 pens of 10 male broiler chicks with three replications was used for three weeks. The results indicated that weight gain, feed in-take, feed efficiency, nonphytic phosphorus (NPP) and tibia ash were significantly different among treatments. Dietary supplemental phosphorus of DFP improved weight gain, NPP intake and feed efficiency consistently, whereas supplements of DCP did not show consistent increase. Regression equations was used for the availability of DPP compared with DCP when percent bone ash was a function of total phosphorus in the diet. The percent (%) bone ash of DFP groups compared to that of DCP groups showed a value of 59.98% as a slope ratio. DFP indicated lower biological availability compared to DCP, but it's dietary supplementation tended to increase bone ash and maximize the growth of young broiler chicks.

  • PDF

Studies on the metabolic activities of Pseudomonas sp. in different carbon sources (Pseudomonas sp.의 탄소원에 따른 대사활성에 관한 연구)

  • 배광성;이영녹
    • Korean Journal of Microbiology
    • /
    • v.20 no.4
    • /
    • pp.161-172
    • /
    • 1982
  • In order to compare the metabolic activities of methanol utilizing bacteria, Pseudomonas sp. grown in different carbon sources, changes in respiratory activities, prinicipal enzyme activities for the energy metabolism, and the macromolecular compositions of the cells grown on methanol or glucose were measured. 1. The respiratory activity of cells grown on methanol was higher than that of cells grown on glucose, while glucose exhibited the highest $O_2-consumption$ rate among the different respiratory substrates. 2. TRhe activity of hydroxy pyruvate reductase which participates in serine pathway was high in the cells grown on methanol. However, activities of NAD-linked alcohol dehydrogenase, formaldehyde dehydrogenase and formate dehydrogenase were slightly lower in the cells grown on glucose thant on methanol. 4. For succinic dehydrogenase and malic dehydrogenase which take part in TCA cycle, the specific activities were higher in the cells grown on methanol than in those grown on glucose. No activity of glucose-6-phosphate dehydrogenase, which participates in pentose monophosphate shunt, was detectable in the cells grown on either carbon sources. 5. Protein contents of the cells grown on methanol increased relatively compared with those of the cells grown on glucose. However, there are no changes in the contents of carbohydrate and nucleic acid.

  • PDF

Single-Inductor, Multiple-Input-Single-Output Converter Based Energy Mixer for Power Packet Distribution System

  • Reza, C.M.F.S.;Lu, Dylan Dah-Chuan;Qin, Ling;Qi, Jian
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1479-1488
    • /
    • 2018
  • Power packet (PP) distribution system distributes power to different loads that share the same distribution cable in a packetized form. When compared with conventional power systems, a PP distribution system (PPDS) can reduce standby power, eliminate Point-of-Load (PoL) power conversion, and intelligently control the load demand from the source side. Due to the absence of PoL conversion, when multiple power sources at different voltage levels and conditioning requirements jointly send power to various loads at different voltage ratings, the generated voltage has an irregular shape. A large filter at each of the load sides is required to reduce such a large voltage ripple. In this paper, a single-inductor, multiple-input-single-output converter structure based multiple-energy-source mixer is proposed. It combines PP generation, maximum power point tracking (MPPT) of renewable energy sources (RESs) and filtering at the source side. To demonstrate the possible renewable energy integration, a PV panel is used as a power source together with other constant voltage sources. The PV power is approximately tracked using the constant voltage method and it is used for each of the PP generations. The proposed PP distribution system is experimentally verified and it is shown that a conventional PI controller is sufficient for stable system operation.