• Title/Summary/Keyword: Different materials

Search Result 14,876, Processing Time 0.043 seconds

Comparison of capsule type resin modified glass ionomer porosity according to mixing methods (혼합방법에 따른 캡슐형 광중합글라스아이노머의 공극률 비교)

  • Kim, Jung-min;Kim, Jin-Woo;Cho, Kyung-Mo;Lee, Yoon;Kim, Eung-Hyun;Park, Se-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.217-224
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the porosity of resin modified glass ionomer (RMGI) by different mixing methods. Materials and Methods: Five specimens were prepared for each groups according to capsules and mixing methods. Two RMGI capsule and two mixing machines were used for this study. One resin-modified glass ionomer cement is Fuji II LC (F2LC) and the other is Photac Fil Quick Aplicap (PFQ). For Mixing of RMGI capsule, Rotomix using rotating motion and CM-II using shaking motion were used. After measuring height, radius and mass of specimens, Density was calculated. And porosity was measured using micro-computed tomography (micro-CT). All data were statistically analyzed using T-test, two-way ANOVA to compare between groups at 95% significance level to evaluate the affect of capsule and mixing method on the porosity. Results: The porosity was observed in all specimens generally. And there is significant differece between porosities according to RMGI capsule and Mixing method. The porosity of PFQ was lower than that of F2LC and the porosity of Rotomix was lower than that of CM-II. Conclusion: There was a difference of porosity according to kind of capsules and mixing methods. When using same capsule, less porosity was observed on PFQ than F2LC. When using same mixing mehod, less porosity was observed on Rotomix than CM-II. Using mixing machine of same coporation as that of RMGI capsule did not lead to lower porosity. Therefore, Selecting optimal mixing machine is important.

Evaluation of the usefulness of Bolus, which combines Step Bolus and 3D Bolus (Step Bolus와 3D Bolus를 combine 한 Bolus의 유용성 평가)

  • Lee, Chang-Suk;Chae, Moon-Ki;Park, Byung-Suk;Kim, Sung-Jin;Joo, Kyoo-Sang;Park, Chul-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.79-88
    • /
    • 2021
  • Objectives: Bolus, which combines 3D-bolus and Step-bolus, was produced and its usefulness is evaluated. Materials and Methods: A Bolus was manufactured with a thickness of 10mm and 5mm using a 3D printer (3D printer, USA), and a Step Bolus of 5mm was bonded to a 5mm thick bolus. In order to understand the characteristics of Step bolus and 3D bolus, the differences in relative electron density, HU value, and mass density of the two bolus were investigated. These two Bolus were applied to anthropomorpic phantom to confirm its effectiveness. After all contouring of the phantom, a treatment plan was established using the computed treatment planning system (Eclipse 16.1, Varian medical system, USA). Treatment plan was performed using electron beam 6MeV, nine dose measurement points were designated on the phantom chest, air-gap was measured at that point, and dose evaluation was performed at the same point for each bolus applied using a glass dosimeter (PLD). Results: Bolus, which combines 3D-bolus 5mm and Step-bolus 5mm, was manufactured and evaluated compared with 3D-bolus 1cm. The relative electron density of 3D Bolus was 1.0559 g/cm2 and the step Bolus was 1.0590 g/cm2, which was different by 0.01%, so the relative electron density was almost the same. In the lightweight measurement of air-gap, the combined bolus was reduced to 54.32% for all designated points compared to 3D-bolus. In the dose measurement using a glass dose meter (PLD), the consistency was high in phantom using combined bolus at most points except the slope point. Conclusion: Combined bolus made by combining 3D-bolus and Step-bolus has all the advantages of 3D-bolus and Step-bolus. In addition, by dose inaccuracy due to Air-gap, more improved dose distribution can be shown, and effective radiation therapy can be performed.

A study of the tensile bond strength between Polyetherketoneketone (PEKK) and various veneered denture base resin (Polyetherketoneketone (PEKK)과 다양한 의치상용 전장 레진 간의 인장결합강도에 관한 연구)

  • Park, Yeon-Hee;Seo, Jae-Min;Lee, Jung-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.3
    • /
    • pp.231-238
    • /
    • 2022
  • Purpose. This study aimed to investigate the effect of different veneering methods on the tensile bond strength between polyetherketoneketone (PEKK) and denture base resins. Materials and methods. A total of 80 PEKK T-shaped specimens were fabricated and the primer (Visio.link) was applied after airborne-particle abrasion with 110 ㎛ alumina oxide powder. According to the veneering method, the specimens were divided into four groups (n = 20) to be veneered with the gingival colored packable photopolymerized composite resin (SR Adoro); flowable photopolymerized composite resin, (Crea.lign); heat-polymerized resin (Vertex); and self-polymerized resin (ProBase Cold). Each group was divided into two subgroups (n = 10) according to the artificial thermal aging. After the tensile bond strength measurement via universal testing machine, the fracture sections of all specimens were observed. Two-way ANOVA and Tukey's HSD post hoc test were used for the statistical analysis (α = .05). Results. The results of the two-way ANOVA showed statistically significant differences in the tensile bond strength according to the veneering method and artificial thermal aging of denture base resins (P<.001). The highest tensile bond strength showed in the packable photopolymerized resin group before and after the artificial thermal aging. The lowest tensile bond strength showed in the heat-polymerized resin group. The mixed and adhesive fracture showed in all groups. Conclusion. The veneering method and artificial thermal aging can influence in the tensile bond strength between the resin and PEKK. The artificial thermal aging can reduce the tensile bond strength.

Comparison of the Clinical Outcomes of an Ultrasound-Guided and C-Arm Guided Cervical Nerve Root Block (초음파와 방사선 투시장치를 이용한 경추 신경근 차단술의 임상결과 비교)

  • Ha, Dae Ho;Shim, Dae Moo;Kim, Tae Kyun;Oh, Sung Kyun;Lee, Hyun Jun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.78-84
    • /
    • 2020
  • Purpose: This paper compares the clinical outcomes of patients who were treated with a cervical nerve block by ultrasound and C-arm and reports the complication. Materials and Methods: A total of 97 patients were treated with an ultrasound-guided nerve root block from May 1, 2015 to February 8, 2018. On the other hand, 94 patients were treated with a C-arm guided nerve root block. The consequences of the cervical pain and the radiating pain before and after the procedures were reviewed using the verbal numeric rating scale (VNRS). In addition, the complications related to the procedures from the daily notes from the chart were inspected. Results: Sixty-six cases out of 97 cases of ultrasound-guided nerve root block were enrolled in the study. The average age of the patients was 57 years, including 41 males and 25 females. Seventy seven out of 94 cases by a C-arm guided root block were included in the study. The average age of the patients was 55 years, including 40 males and 37 females. Before the nerve root block, the mean numeric rating pain scale (NRS) of the cervical pain in ultrasound-guided block decreased from 5.4 points to 2.7 points at three weeks and 1.4 points at six weeks (p=0.0023, p<0.001), and 3.1 points in the C-arm (p<0.001, p<0.001) at three weeks and 1.5 points at six weeks (p<0.001, p<0.001). In the case of radiating pain, the mean NRS in the ultrasound-guided nerve root block group improved from 6.3 points after the procedure to 2.8 points at three weeks and 1.5 points at six weeks (p<0.001, p<0.001). In the C-arm guided nerve root block group, the NRS improved from 7.4 points after the procedure to 3.3 points at three weeks and 1.9 points at six weeks. In the case of complications, Horner's syndrome and propriospinal myoclonus were observed in one case of C-arm guided block group. Conclusion: The clinical results of the patients who underwent ultrasound-guided cervical nerve root block were not significantly different from those who underwent a C-arm guided cervical nerve root block.

Statistical Evaluation of Moisture Resistance by Mixing Method of Recycled Asphalt Mixtures (혼합방법에 따른 순환아스팔트 혼합물의 수분저항성 통계검정 평가)

  • Kim, Sungun;Kim, Yeongsam;Jo, Youngjin;Kim, Kwangwoo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.2
    • /
    • pp.167-176
    • /
    • 2021
  • When producing recycled asphalt mix, it is important that the old binder of reclaimed asphalt pavement(RAP) should be well melted during blending in the mixer. The recycled asphalt mix is produced by instant mixing(IM) of all materials(RAP, virgin asphalt and new aggregates) all together in the mixer. However, in the same recycled mix, the binder around RAP aggregate was found to show higher oxidation level than the binder coated around the virgin aggregate because the old binder of RAP was not rejuvenated properly while instant mixing. The partially-rejuvenated RAP binder is assumed to be a high stiffness point in IM recycled mix. In this study, the stage mixing(SM) method was introduced; blending RAP and virgin asphalt for the first stage, and then mixing all together with hot new aggregates for the second stage. To compare the effect of the two mixing methods on moisture resistance of recycled mixes, a statistical t-test was performed between SM and IM using indirect tensile strength(ITS) and tensile strength ratio(TSR). Three conditioning methods were used; a 16-h freezing and then 24-h submerging, 48-h submerging, and 72-h submerging in 60℃ water. It was found that the TSR(=ITSwet/ITSdry) values of the mixes prepared by SM was clearly higher than the IM mixes, and coefficients of variation of SM mixes were lower than the IM mixes. It was also observed that the ITSWET of SM was significantly different from the IM at α=0.05 level by statistical t-test. The ITSWET of SM mix was reduced less than the IM mix in severer conditioned mixes. Therefore, it was concluded that the stage mixing method was an important blending technique for producing better-quality of recycled asphalt mixes, which would show higher moisture resistance than the recycled mixes produced by conventional instant mixing.

Surgical Treatment for Longitudinal Epiphyseal Bracket of the Finger (수지의 종적 Bracket 골단에 대한 수술적 치료)

  • Kim, Sung Soo;Kim, Ki Woong;Kim, Jung Ho;Lee, Chan Soo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.2
    • /
    • pp.154-161
    • /
    • 2020
  • Purpose: To describe the clinical and radiology results of a surgical treatment for clinodactyly due to a longitudinal epiphyseal bracket. Materials and Methods: This study analyzed the records of 11 patients (27 case) with clinodactyly due to a longitudinal epiphyseal bracket who underwent an osteotomy or physiolysis between March 1999 and April 2017. The preoperative range of motion of the proximal and distal interphalangeal joints, the subjective satisfaction of the patient, and the degree of angulation to the ulnar side were examined. The patients were classified into two groups: osteotomy and physiolysis. The results were reviewed retrospectively and compared according to the surgical method. Results: The mean age of the patients who underwent osteotomy was 10.3 years. The average preoperative angle was 25.7° and the average postoperative angle was 13.5° the mean correction rate was 47.4%. The mean age of the patients who underwent physiolysis was 6.0 years the mean preoperative angle was 24.5° and the postoperative angle was 10.7°. The average correction rate was 59.4%. No significant difference in the correction angles was observed between the group who underwent the correction osteotomy and the group who underwent the osteotomy. In each group, the postoperative correction was statistically significant. The range of motion at the last follow-up was not significantly different from the preoperative range of motion. Conclusion: In patients with clinodactyly due to longitudinal epiphyseal bracket, osteotomy or physiolysis may be performed selectively according to age, bone age, and radiological progression. Both surgical methods showed good clinical results and deformity correction.

Spatio-Temporal Variation Characteristics of Primary Productivity and Environmental Factors of Shellfish Mariculture in Jaran Bay, Korea (자란만 패류양식어장의 기초생산력 및 환경인자 변동 특성)

  • Lee, Dae In;Choi, Yong-Hyeon;Hong, SokJin;Kim, Hyung Chul;Lee, Won-Chan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.5
    • /
    • pp.721-734
    • /
    • 2022
  • This study analyzed the spatio-temporal variation characteristics of major environmental factors such as primary productivity (PP), chlorophyll a, nutrients, sinking particle matters, and organic contamination and biochemical composition of surface sediment on a monthly basis for approximately 2 years around shellfish mariculture in Jaran Bay, Korea. In addition, PP in Jaran Bay was compared with that in other coastal areas and related policy plans were proposed. The average PP of the study area was high in summer and autumn with 6.43~115.43 mgC m-2 hr-1 range. This was lower than that in Gamak Bay and Masan Bay, whereas higher than that in Garorim Bay and the West Sea. The PP in coastal waters, where many aquaculture farms were distributed, significantly fluctuated. The different size compositions of phytoplanktons constituting chlorophyll a slightly varied by month, and little restriction existed on the productivity of phytoplanktons owing to the depletion of nutrients. Typically, the Redfield ratio was less than 16, indicating that nitrogen was the limiting factor for the growth of phytoplanktons. The biochemical composition of particulate organic matters in the water column showed the highest carbohydrates, but lipids and protein contents were high in surface sediments. The concentration of TOC and AVS of the surface sediments was high at inside of bay, and sometimes, exceeded the environmental criteria of fishing grounds. The organic C:N ratio of sediments ranged from 8.1 to 10.4 on average. PP had the highest correlation with chlorophyll a, nitrogen and protein of particle organic materials. Recently, chlorophyll a, DIN, and DIP of water column trends tended to decrease, however, the contamination of sediments increased. Considering the annual PP of 125.9 gC m-2 yr-1 and mariculture area (oyster) of 4.97 km2, the annual carbon production from phytoplanktons was estimated to be about 625 tons, and the annual total wet weight of shellfish (oyster) was estimated to be about 6,250 tons.

A Comparative Study of Production of [68Ga]PSMA-11 with or without Cassette Type Modules (비 카세트 방식과 카세트 방식을 이용한 [68Ga]PSMA-11의 자동 합성 방법 비교)

  • Hyun-Sik, Park;Byeong-Min, Jo;Hyun-Ho, An;Hong-Jin, Lee;Jin-Hyeong, Lee;Gyeong-Jae, Lee;Byung-Chul, Lee;Won-Woo, Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.15-19
    • /
    • 2022
  • Purpose [68Ga]PSMA-11 is needed the high reproducibility, excellent radiochemical yield and purity. In term of radiation safety, the radiation exposure of operator for its production also should be considered. In this work, we performed a comparative study for the fully automated synthesis of [68Ga]PSMA-11 between non-cassette type and cassette type. Materials and Methods Two different type of modules (TRACERlab FX N pro for non-cassette type and BIKBox for cassette type) were used for the automated production of [68Ga]PSMA-11. According to the previously identified elution profile, Only 2.5 ml with high radioactivity was used for the reaction. After adjusting the pH of the reaction solution with HEPES buffer solution, the precursor was added and reacted with at 95 ℃ for 15 minutes. The reaction mixture was separated and purified using a C18 light cartridge. The product was eluted with 50% EtOH/saline solution and diluted with saline. It was completed by sterilizing filter. In the non-cassette type, the aforementioned process must be prepared directly. However, in the cassette method, synthesis was possible simply by installing a kit that was already completed. Results Both total [68Ga]PSMA-11 production time were 25±3(non-cassette type) and 23±3 minutes(cassette type). The radiochemical yield of the non-cassette type(65.5±5.7%) was higher than that of the cassette type(61.6±4.8%) after sterilization filter. The non-cassette type took about 120 minutes of preparation time before synthesis due to washing of synthesizer and reagent preparation. However, since the cassette type does not require washing and reagent preparation, it took about 20 minutes to prepare before synthesis. Both type of synthesizer had a radiochemical high purity(>99%). Conclusion The non-cassette type production of [68Ga]PSMA-11 showed higher radiochemical yield and lower cost than the cassette type. However, The cassette type has an advantage in terms of preparation time, convenience, and equipment maintenance.

A Randomized Phase III Study of Patients With Advanced Gastric Adenocarcinoma Without Progression After Six Cycles of XELOX (Capecitabine Plus Oxaliplatin) Followed by Capecitabine Maintenance or Clinical Observation

  • Guk Jin Lee;Hyunho Kim;Sung Shim Cho;Hyung Soon Park;Ho Jung An;In Sook Woo;Jae Ho Byun;Ji Hyung Hong;Yoon Ho Ko;Der Sheng Sun;Hye Sung Won;Jong Youl Jin;Ji Chan Park ;In-Ho Kim;Sang Young Roh;Byoung Yong Shim
    • Journal of Gastric Cancer
    • /
    • v.23 no.2
    • /
    • pp.315-327
    • /
    • 2023
  • Purpose: Oxaliplatin, a component of the capecitabine plus oxaliplatin (XELOX) regimen, has a more favorable toxicity profile than cisplatin in patients with advanced gastric cancer (GC). However, oxaliplatin can induce sensory neuropathy and cumulative, dose-related toxicities. Thus, the capecitabine maintenance regimen may achieve the maximum treatment effect while reducing the cumulative neurotoxicity of oxaliplatin. This study aimed to compare the survival of patients with advanced GC between capecitabine maintenance and observation after 1st line XELOX chemotherapy. Materials and Methods: Sixty-three patients treated with six cycles of XELOX for advanced GC in six hospitals of the Catholic University of Korea were randomized 1:1 to receive capecitabine maintenance or observation. The primary endpoint was progression-free survival (PFS), analyzed using a two-sided log-rank test stratified at a 5% significance level. Results: Between 2015 and 2020, 32 and 31 patients were randomized into the maintenance and observation groups, respectively. After randomization, the median number of capecitabine maintenance cycles was 6. The PFS was significantly higher in the maintenance group than the observation group (6.3 vs. 4.1 months, P=0.010). Overall survival was not significantly different between the 2 groups (18.2 vs. 16.5 months, P=0.624). Toxicities, such as hand-foot syndrome, were reported in some maintenance group patients. Maintenance treatment was a significant factor associated with PFS in multivariate analysis (hazard ratio, 0.472; 95% confidence interval, 0.250-0.890; P=0.020). Conclusions: After 6 cycles of XELOX chemotherapy, capecitabine maintenance significantly prolonged PFS compared with observation, and toxicity was manageable. Maintenance treatment was a significant prognostic factor associated with PFS.

Clinical Result of a Staged Reimplantation of Fungus Related Periprosthetic Joint Infection after Total Knee Arthroplasty (슬관절 전치환술 후 인공관절 주위 진균 감염의 임상적 결과)

  • Kim, Hyung Joo;Bae, Ki Cheor;Min, Kyung Keun;Choi, Hyeong Uk
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.1
    • /
    • pp.52-58
    • /
    • 2019
  • Purpose: Fungal periprosthetic joint infection (PJI) is a rare but devastating complication following total knee arthroplasty (TKA). On the other hand, a standardized procedure regarding an accurate treatment of this serious complication of knee arthroplasty is lacking. The clinical progress of staged reimplantation in patients who had fungus-related PJI after TKA was reviewed retrospectively. Materials and Methods: Ten patients who had a fungal related PJI after TKA between 2006 and 2017 using staged reimplantation surgery were reviewed. These patients were compared with 119 patients who had a PJI in the same period. The failure rate of infection control, intravenous antimicrobial using the period, and the clinical results were evaluated by comparing the range of motion and Korean knee score (KKS) between pre-staged reimplantation and the last follow-up. Results: In the fungal infection group, 7 out of 10 cases (70.0%) had failed in infection control using staged reimplantation and in the non-fungal group, 7 out of 119 cases (5.9%) had failed (p=0.04). In the non-fungal group, the mean duration of antibiotics was 6.2 weeks. In the fungus group, the mean duration of antibiotics was 15.3 weeks, which was 9.1 weeks longer (p<0.001). The range of motion of the knee was increased in the two groups (p=0.265). At the last follow-up, the KKS was 71.01 points in the non-fungal group and 61.3 points in the fungal group (p=0.012). Erythrocyte sedimentation rate and C-reactive protein (CRP) decreased in the two groups, but the CRP was significantly different in the two groups (p=0.007). Conclusion: The treatment of fungus-related PJIs using staged reimplantation showed uneven clinical progress and unsatisfactory clinical improvements compared to non-fungal PJI. Therefore, it is necessary to consider the use of an antifungal mixed cement spacer at resection arthroplasty and oral antifungal agent after reimplantation.