• 제목/요약/키워드: Different Thickness

검색결과 4,580건 처리시간 0.027초

팔동작에 미치는 어깨패드의 영향에 관하여 -심미성과 기능성을 중심으로- (Effect of the Shoulder Pad on Arm Movement -In the Area of Functionality and Sensory)

  • 이은정
    • 복식문화연구
    • /
    • 제6권2호
    • /
    • pp.66-76
    • /
    • 1998
  • In order to investigate the effect of shoulder pad affecting the arm movement, eleven women volunteers of standard body whose age is from eighteen to twenty-four(x±1σ) were chosen and this experiment had done according to front-vertical motion, side-vertical motion and horizontal motion of upper limps for tow different materials of shoulder pad(sponge, non-woven) and four different thickness of shoulder pad(0.6cm, 0.8cm, 1.2cm). On the base of this, this study, when putting on shoulder pad, try to find the reform method of shoulder part pattern. The results are as follows. 1. When puting on shoulder pad to blouse pattern to rise shoulder pad for rate of two-third per thickness is seemingly the best for sensory evaluation. So, when putting on shoulder pad, we understand that in order to improve sensory evaluation. So, when putting on shoulder pad, we understand that in order to improve sensory evaluation of clothes, when that, rising shoulder pad for ate of two-third per thickness is the best. 2. From the results of measure of functional volume and physiological value for functionality evaluation according to thickness and material, motion of shoulder pad, 1.2 cm thickness and non-woven material is evaluated the worst for functionality. 3. From the results of sensory evaluation and functionality evaluation of material of shoulder pad, sponge material is superior for functionality but not for sensory evaluation, non-woven material is superior for sensory evaluation non-woven material is superior for sensory evaluation but not for functionality. So, think that it had better use sponge material for functional clothes, non-woven material for aesthetical clothes. 4. From the results of functionality of clothes, when putting on shoulder pad, the worst discomfortable parts are the armpit part and the shawl part, functionality of these part shoulder be reformed.

  • PDF

합성얼음의 두께변화와 선형변화에 따른 Pack ice 상태에서의 쇄빙상선의 저항특성 연구 (Study on Resistance Performance of Icebreaking Cargo Vessel in Pack Ice Condition according to Variation of Synthetic Ice Thickness and Hull Form Characteristics)

  • 이승호;김문찬;전호환;조준철;신병철;정운화
    • 대한조선학회논문집
    • /
    • 제46권5호
    • /
    • pp.471-478
    • /
    • 2009
  • The present paper deals with characteristics of resistance performance according to the variation of synthetic ice thickness and hull form. The resistance test has been conducted with pack ice condition in Pusan National University towing tank. Stem angle has been chosen as main parameters for the variation of hull form characteristics, which is the most important factor especially in icebreaking cargo vessel. The serial comparisons of resistance test have been done with the variation of hull form parameter as well as with the different thickness of synthetic ice. The different trend of resistance performances with increasing of stem angle has been shown at each synthetic ice thickness. The present test results is expected to be confirmed by comparing the test results in ice tank in the near future.

흡광 광도 분석법을 이용한 기름의 두께 측정 연구 (Oil Thickness Measurement by Light Absorption Analysis)

  • 오상우;이문진
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제16권4호
    • /
    • pp.263-267
    • /
    • 2013
  • 본 연구에서는 단일 파장의 빛이 기름과 해수로 구성된 혼합물을 투과하는 과정에서 굴절과 산란으로 인해 감쇠되는 빛의 세기를 평가하는 방법을 통해, 물위에 존재하는 기름의 두께를 측정할 수 있는 새로운 광학적 기름 탐지 방법론을 제시한다. 단일 파장의 광원으로 직진성이 좋고 단색광의 빛을 발산할 수 있는 레이저를 이용하였으며, 기름-물 혼합물을 투과한 빛의 세기를 정량적으로 측정하기 위해서 광 에너지를 전기 에너지로 변환할 수 있는 광전자소자인 포토다이오드를 선택하였다. 기름의 두께가 증가함에 따라서 투과된 빛의 크기가 점차적으로 감쇠되는 성질을 가진 광원의 파장 대역을 실험적으로 도출하기 위해서, 3개의 서로 다른 파장대역을 갖는 레이저를 이용하여 기름의 두께별로 투과된 광량을 측정하여 감쇠되는 경향을 비교하는 실험을 진행하였다. 해당 실험을 통해서 470 nm 파장을 갖는 청색 레이저를 이용하였을 경우, 기름의 두께가 증가함에 따라 투과된 광량의 세기가 점차적으로 감쇠되는 현상을 확인할 수 있었다. 본 연구에서 수행한 실험 결과를 통해서 레이저 광원에 대한 기름의 흡광 광도를 분석하는 방법으로 해수위에 존재하는 기름의 두께를 정량적으로 측정할 수 있는 가능성을 제시하였다.

The effect of mortar type and joint thickness on mechanical properties of conventional masonry walls

  • Zengin, Basak;Toydemir, Burak;Ulukaya, Serhan;Oktay, Didem;Yuzer, Nabi;Kocak, Ali
    • Structural Engineering and Mechanics
    • /
    • 제67권6호
    • /
    • pp.579-585
    • /
    • 2018
  • Masonry walls are of a complex (anisotropic) structure in terms of their mechanical properties. The mechanical properties of the walls are affected by the properties of the materials used in wall construction, joint thickness and the type of masonry bond. The carried-out studies, particularly in the seismic zones, have revealed that the most of the conventional masonry walls were constructed without considering any engineering approach. Along with that, large-scale damages were detected on such structural elements after major earthquake(s), and such damages were commonly occurred at the brick-joint interfaces. The aim of this study was to investigate the effect of joint thickness and also type of mortar on the mechanical behavior of the masonry walls. For this aim, the brick masonry walls were constructed through examination of both the literature and the conventional masonry walls. In the construction process, a single-type of brick was combined with two different types of mortar: cement mortar and hydraulic lime mortar. Three different joint thicknesses were used for each mortar type; thus, a total of six masonry walls were constructed in the laboratory. The mechanical properties of brick and mortars, and also of the constructed walls were determined. As a conclusion, it can be stated that the failure mechanism of the brick masonry walls differed due to the mechanical properties of the mortars. The use of bed joint thickness not less than 20 mm is recommended in construction of conventional masonry walls in order to maintain the act of brick in conjunction with mortar under load.

사상체질과 대사증후군 및 경동맥 내중막두께와의 상관관계 연구 (A Study on the Correlation of Metabolic Syndrome and Intima-media Thickness of Common Carotid Artery with Sasang Constitution)

  • 이준희;김상혁;이의주;송일병;고병희
    • 사상체질의학회지
    • /
    • 제19권1호
    • /
    • pp.148-159
    • /
    • 2007
  • 1. Objectives The purpose of this study was to investigate the correlation of Metabolic syndrome(MetS) and Intima-media thickness(IMT) of common carotid artery with Sasang constitution. 2. Methods 197 subjects who had taken health examinations and diagnosis of Sasang constitution from Jan 1, 2006 to Dec 31, 2006 at East-west health examination center of Kyung-Hee medical center were included and underwent B-mode ultrasonography for measurement of intima-media thickness of common carotid arteries. MetS was defined by the criteria of the criteria of the National Cholesterol Education Program Adult Treatment Panel III. 3. Results and Conclusions Mean intima-media thickness of common carotid artery was significantly higher in subjects with MetS compared with control subjects($0.070{\pm}0.017$ vs $0.063{\pm}0.014cm$) and a significant trend towards increased IMT was observed with increasing numbers of metabolic syndrome components(r=0.331, p=0.000). After adjustment for age and sex, IMT of common carotid arteries was significantly different among three constitutional groups (Soyangin:$0.065{\pm}0.015cm$, Taeumin:$0.068{\pm}0.016cm$, Soeumin:$0.056{\pm}0.010cm$), however, after adjustment for age, sex and existence of metabolic syndrome, there was no significant different. But, factor of Taeumin was the effective determinant of the increase of mean IMT of common carotid arteries.

  • PDF

Comparative Effect of Modified Shrug Exercises With and Without Trunk Stabilization Exercise on Scapular Upward Rotator EMG and Thickness in Subjects With Scapular Downward Rotation Syndrome

  • Kim, Ji-hyun;Yoon, Hyeo-bin;Park, Joo-hee;Jeon, Hye-seon
    • 한국전문물리치료학회지
    • /
    • 제24권4호
    • /
    • pp.60-67
    • /
    • 2017
  • Background: Scapular downward rotation syndrome (SDRS) is a common scapular alignment impairment that causes insufficient upward rotation and muscle imbalance, shortened levator scapulae (LS) and rhomboid, and lengthened serratus anterior (SA) and trapezius. A modified shrug exercise (MSE), performing a shrug exercise with the shoulders at $150^{\circ}$ abduction, is known as an effective exercise to increase scapular stabilizer muscle activation. Previous studies revealed that scapular exercise are more effective when combined with trunk stabilization exercises in decreasing scapular winging and increasing scapular stabilizer muscle activation. Objects: The purpose of our study was to clarify the effect of MSE with or without trunk stabilization exercises in subjects with SDRS. Methods: Eighteen volunteer subjects (male=10, female=8) with SDRS were recruited for this experiment. All subjects performed MSE under 3 different conditions: (1) MSE, (2) MSE with an abdominal draw-in maneuver (ADIM), and (3) MSE with an abdominal expansion maneuver (AEM). The muscle thickness of the lower trapezius (LT) and the SA were measured using an ultrasonography in each condition. Electromyography (EMG) data were collected from the LT, LS, SA, and upper trapezius (UT) muscle activities. Data were statistically analysed using one-way repeated analysis of variance at a significance level of .05. Results: The muscle thickness of the LT and the SA were the significant different in the MSE, MSE with ADIM (MSE+ADIM) and MSE with AEM (MSE+AEM) conditions (p<.05) In both LT and SA, the order of thick muscle thickness was MSE+AEM, MSE+ADIM, and MSE alone. No significant differences were found in the EMG activities of the SA, UT, LS, and LT in all condition. Conclusion: In conclusion, MSE is more beneficial to people with SDRS when combined with trunk stabilization exercises by increased thickness of scapular stabilizer muscles.

Effect of Target Angle and Thickness on the Heel Effect and X-ray Intensity Characteristics for 70 kV X-ray Tube Target

  • Kim, Gyehong;Lee, Rena
    • 한국의학물리학회지:의학물리
    • /
    • 제27권4호
    • /
    • pp.272-276
    • /
    • 2016
  • To investigate the optimum x-ray tube design for the dental radiology, factors affecting x-ray beam characteristics such as tungsten target thickness and anode angle were evaluated. Another goal of the study was to addresses the anode heel effect and off-axis spectra for different target angles. MCNPX has been utilized to simulate the diagnostic x-ray tube with the aim of predicting optimum target angle and angular distribution of x-ray intensity around the x-ray target. For simulation of x-ray spectra, MCNPX was run in photon and electron using default values for PHYS:P and PHYS:E cards to enable full electron and photon transport. The x-ray tube consists of an evacuated 1 mm alumina envelope containing a tungsten anode embedded in a copper part. The envelope is encased in lead shield with an opening window. MCNPX simulations were run for x-ray tube potentials of 70 kV. A monoenergetic electron source at the distance of 2 cm from the anode surface was considered. The electron beam diameter was 0.3 mm striking on the focal spot. In this work, the optimum thickness of tungsten target was $3{\mu}m$ for the 70 kV electron potential. To determine the angle with the highest photon intensity per initial electron striking on the target, the x-ray intensity per initial electron was calculated for different tungsten target angles. The optimum anode angle based only on x-ray beam flatness was 35 degree. It should be mentioned that there is a considerable trade-off between anode angle which determines the focal spot size and geometric penumbra. The optimized thickness of a target material was calculated to maximize the x-ray intensity produced from a tungsten target materials for a 70 keV electron energy. Our results also showed that the anode angle has an influencing effect on heel effect and beam intensity across the beam.

만성뇌졸중 환자의 최대 호기와 배 안으로 밀어 넣기가 복부근육두께에 미치는 효과 (A comparison of the Effects on Abdominal Muscles between the Abdominal Drawing-in Maneuver and Maximal Expiration in Chronic Stroke Patients)

  • 서동권;김지선
    • 대한물리의학회지
    • /
    • 제10권4호
    • /
    • pp.33-38
    • /
    • 2015
  • PURPOSE: Although the abdominal drawing-in maneuver is commonly used in clinical training for trunk stability, performing this procedure in stroke patients is difficult; instead, maximal expiration can be much easily performed in stroke patients. In the present study, we first aimed to demonstrate the effects of the abdominal drawing-in maneuver and maximal expiration on trunk stability in stroke patients. Moreover, we compared the thickness of the transverse abdominal, internal oblique, and external oblique muscles on the paretic and non-paretic sides. METHODS: We used ultrasonography to measure the change in the thickness of the transverse abdominal, internal oblique, and external oblique muscles on the paretic and non-paretic sides at rest, while performing the abdominal drawing-in maneuver, and while performing maximal expiration in 23 stroke patients. The ratio of muscle thickness between different conditions was estimated and included in the data analysis (abdominal drawing-in maneuver / at rest and, maximal expiration / at rest). RESULTS: The ratio of the thickness of the transverse abdominal, internal oblique and external oblique muscles during maximal expiration was significantly different on the paretic side (p < 0.05). The ratio of muscle thicknesses on the non-paretic side was greater during maximal expiration than during the abdominal drawing-in maneuver, although this difference was not significant (p > 0.05). CONCLUSION: Our results suggest that maximal expiration more effectively increased the abdominal muscle thickness on the paretic side. Hence, we recommend the application of maximal expiration in clinical trunk stability training on the paretic side of stroke patients.

지지면에 따른 발목관절의 족저굴곡 운동이 비복근 두께에 미치는 영향 (The Effect of Calf-Raise Exercise on Gastrocnemius Muscle Based on Other Type of Supports)

  • 이건철;김봄;김지수;남인성;박유진;신우진;우수민;차성기
    • 대한통합의학회지
    • /
    • 제2권1호
    • /
    • pp.109-116
    • /
    • 2014
  • Purpose : The purpose of this study was to perform the calf-raise exercise on the stable support surface and unstable support surface for comparing deference of the gastrocnemius thickness changes that measured by ultrasonography. Method : Subjects stand on unstable support surface and a stable support surface with both feet. Keeping calf-raise position in the 3 seconds, and then had to return back to the starting position. Total of 3 sets of 15 repetitions performed and give a 30-second rest between each set. In this way, exercise performed 3 times a week, performed a total of 6 weeks. Result : 1. gastrocnemius muscle thickness before and after exercise in experimental group A was significantly different(p<.05). 2. gastrocnemius muscle thickness before and after exercise in experimental group B was significantly different(p<.05). 3. gastrocnemius muscle thickness in experimental group A and experimental group B was significantly difference(p<.05). Conclusion : In conclusion, calf-raise exercise on unstable support surface was more efficient than stable support surface for increasing thickness of gastrocnemius.

디지털 광학기술인 3D 프린터로 제작된 임시수복용 레진의 두께별 색 평가 (Color evaluation by thickness of interim restorative resin produced by digital light processing 3D printer)

  • 강월;김원기
    • 대한치과기공학회지
    • /
    • 제43권3호
    • /
    • pp.77-83
    • /
    • 2021
  • Purpose: The purpose of this in vitro study was to measure and compare the thickness-dependent color dimensions of digital light processing (DLP) three-dimensional (3D) printer and conventional interim restorative resin. Methods: Specimens (N=60) were fabricated using either subtractive manufacturing (S group) or DLP 3D printing (D group) material. All milled and 3D-printed specimens were allocated into three different groups (n=10) according to different thicknesses as follows: 1.0, 1.5, and 2.0 mm. Color measurements in the CIELab coordinates were made using a spectrophotometer under room light conditions (1,003 lux). The color differences (𝚫E*) between the specimen and control target data were calculated. Data were analyzed using the oneway analysis of variance (ANOVA). Post hoc comparisons were conducted using Tukey's honestly significant difference method (α=0.05 for all tests). Results: The 𝚫L*, 𝚫a*, 𝚫b*, and 𝚫E* values of interim restorative resin produced by DLP 3D printing were obtained in terms of the specimen's thickness increased compared with the increases by subtractive manufacturing. When the thickness was similar, the color difference between subtractive manufacturing and DLP 3D printing was ≥5.5, which is a value required by the dentist for remanufacturing. Conclusion: Color was influenced by the thickness of the interim restorative resin produced by DLP 3D printing.