• 제목/요약/키워드: Different Thickness

검색결과 4,569건 처리시간 0.029초

국소의치상을 위한 연성 이장재사용시 교합압에 따른 의치상 변위(Displacement)량 비교 (A STUDY ON DIFFERENT AMOUNT OF DENTURE BASE DISPLACEMENT USING SOFT DENTURE RELINING MATERIAL UNDER MASTICATORY FORCE)

  • 이호용
    • 대한치과보철학회지
    • /
    • 제36권1호
    • /
    • pp.18-25
    • /
    • 1998
  • The purpose of this study was to determine how to use soft relining material by observing an amount of denture displacement according to the different base area of residual ridge and thickness of soft relining material under masticatory force. Stone models that simulated residual ridge were made with different amount of denture base area and denture was fabricated by conventional heat curing resin with usual manner on the model and relined by silicone type soft relining material with different thickness. Specimen was examined the amount of denture displacement by Instron within range of normal occlusal force. The results were as following : 1. The increasing rate of denture displacement was higher than that of soft relining material thickness. 2. The amount of denture displacement decreased 1.7 times when base area became double at same thickness of soft relining material 3. The increasing rate of denture displacement was higher than that of occlusal force

  • PDF

Effects of Blood Flow Restriction and Different Support Surfaces on the Thickness of Type-I Muscle Fibers in the Trunk

  • Park, Jae-Cheol;Oh, Seung-Keun;Jeong, Jin-Gyu
    • The Journal of Korean Physical Therapy
    • /
    • 제29권2호
    • /
    • pp.69-73
    • /
    • 2017
  • Purpose: This study was conducted to investigate the effects of blood flow restriction and different support surfaces for bridge exercises on the thickness of the transverse abdominis and multifidus, which are trunk-stabilizing muscles. Methods: The study's subjects were 45 adults who were divided into three groups that performed bridge exercises over a six-week period on their respective support surfaces after blood flow restriction. Changes in the thickness of the subjects' transverse abdominis and multifidus muscles were measured using ultrasonography before the experiment, then three and six weeks after the experiment. The changes in each variable over time were analyzed using a repeated-measures analysis of variance (ANOVA). Results: The transverse abdominis showed significant differences in muscle thickness with regard to time and the interaction between time and each group (p<0.05), but no significant differences with regard to changes among groups (p>0.05). The multifidus showed significant differences in muscle thickness with regard to time, the interaction between time and each group, and changes between groups (p<0.05). Conclusion: Blood flow restriction and different support surfaces for bridge exercises led to significant differences in the thickness of the transverse abdominis and multifidus. This study's results may be used as the basis for future studies and for rehabilitation in clinical practice.

지대치 코어 재료와 In-Ceram coping의 두께가 In-Ceram의 색에 미치는 영향 (COLOR DIFFERNCE OF IN-CERAM BY THE VARIOUS POSTCORE MATERIALS AND COPING THICKNESS)

  • 심직현;방몽숙
    • 대한치과보철학회지
    • /
    • 제33권4호
    • /
    • pp.634-644
    • /
    • 1995
  • The purpose of this study is to evaluate the color differences in the In-Ceram according to coping thickness and various abutment core materials ; amalgam, precious alloy, composite resin, non-precious alloy. After the porcelain was built up on the In-Ceram coping at the thicknes of 0.3mm and 0.5mm then it was cemented with glass ionomer cement to the post & core materials. The following results were obtained. 1. There were significant differences in the $L^*$ values $a^*$ and $b^*$ values in the cementation of different cores, to the In-Ceram(P<0.01). $L^*$ values were not significantly different between the composite resin to the In-Ceram and the $a^*\;b^*$ values were not significantly different between the amalgam and the non-precious alloy. 2. All of cementations of In-Ceram to the core materisal had color difference(${\Delta}E^*ab$) compared to the In-Ceram. In the 0.3mm thickness of the In-Ceram copping non-precious alloy indicated the greatest value, while the composite resin core showed the lowest value with a thickness of 0.5mm In-Ceram copping. 3. By controlloing the In-Ceram coping thickness $L^*$ value was significatly different(P<0.01), but not in $a^*$ and $b^*$ values. 4. In an amalgam, precious & non-prcious alloys there was a 1,74 to 3.06 range color difference in the controlled thickness of In-Ceram coping at the thickness of 0.3mm and 0.5mm. The above results suggest that the requirement of the sufficient thickness of In-Ceram coping and the suitable core material in order to get an estheti restoration by In-Ceram and also to intercept the original core color.

  • PDF

캐드캠 세라믹의 코어와 베니어의 서로 다른 두께가 반투명도에 미치는 영향 (Effect of translucency on CAD/CAM ceramic according to different core/veneer thickness)

  • 강월;김지환
    • 한국치위생학회지
    • /
    • 제18권6호
    • /
    • pp.1037-1045
    • /
    • 2018
  • Objectives: The purpose of this study was to evaluation the effect of translucency on CAD/CAM ceramic according to different core/veneer thicknesses. Methods: A total of 42 samples from 2 groups of 7 ceramic cores, each with 3 thickness values (0.8, 1.0, 1.2 mm) were manufactured. The veneers were also manufactured in 3 thicknesses (0.3, 0.5, 0.7 mm). The group names were based on the name of the ceramic core (IPS e.Max CAD; LD, and IPS Empress CAD; LR). The associated number was determined by the combined thickness of the core and veneer: 1 = (0.8 + 0.7); 2 = (1.0 + 0.5); 3 = (1.2 + 0.3). The translucency was measured using a spectrophotometer and defined via the contrast ratio (CR) and translucency parameter (TP). Two-way ANOVA was performed to compare the 2 groups (material and thickness). Results: As the core thickness increased, the TP value also increased, and the CR value (for LR group) decreased. The results of 2-way ANOVA demonstrated that the thicknesses of different core/veneer combinations significantly affected the translucency (p<0.05). Conclusions: The different core and veneer thicknesses affected the translucency of CAD/CAM ceramic.

라면 면대의 균일한 두께를 위한 압연공정 자동화 (Rolling Process Automation For Uniform Thickness of Dough Sheet of Ramen Noddles)

  • 유동상;유병국
    • 조명전기설비학회논문지
    • /
    • 제26권11호
    • /
    • pp.97-103
    • /
    • 2012
  • The basic processing unit for instant ramen noodles includes mixing, rolling, boiling, frying, cooling, and packing processes. For uniform thickness of dough sheets in rolling process, the roll-gap in rolling process needs to keep uniform thickness of flour sheets in spite of different kinds of raw materials. In this paper, we have developed a roll gap adjustment system using a PLC (Programmable Logic Controller) with a touch panel and an AC servo-mechanism to make dough sheets with a good gluten starch-network structure and uniform thickness and to contribute to process standardization by transferring from tacit knowledge of skilled workers to explicit knowledge. The developed system can adjust the roll gap in units of 0.01mm and correspond to various product items which have different thickness specification by recalling the presetting values of the desired thickness from database.

TiO2 광전극 두께와 두 기판 간격에 따른 DSSC의 효율 특성 (DSSCs Efficiency by Thickness of TiO2 Photoelectrode and Thickness Differences Between Two Substrates)

  • 박한석;권성열;양욱
    • 한국전기전자재료학회논문지
    • /
    • 제25권7호
    • /
    • pp.537-542
    • /
    • 2012
  • DSSCs efficiency by thickness of $TiO_2$ photoelectrode and thickness differences between two substrates studied. DSSCs is made of the doctor blade method and photoelectrode annealing temperature elevated in a different ways. In addition, cells efficiencies of according to the different thickness between $TiO_2$ photoelectrode substrate and Pt counter electrode was measured. Efficiency of DSSCs made with $TiO_2$ photoelectrode of 18 ${\mu}m$ thickness and the gap difference between the substrate 28 ${\mu}m$ shows a highest 4.805% efficiency.

경계조건에 따른 판 구조물의 최적두께분포에 대한 연구 (A Study on the Optimum Thickness Distributions of Plate Structures with Different Essential Boundary Conditions)

  • 이상진;김하룡
    • 한국공간구조학회논문집
    • /
    • 제5권4호
    • /
    • pp.53-59
    • /
    • 2005
  • 이 논문은 경계조건에 따른 판구조물의 최적두께분포 변화에 대한 연구결과를 기술하였다. 본 연구에서는 최소화하고자하는 변형에너지를 목적함수로 하고 구조물의 초기 부피 값을 제약조건으로 사용하였다. 판구조물의 두께분포를 표현하기 위하여 쿤이 개발한 조각 면을 이용하였다. 판의 변형에너지를 정확히 계산하기 위하여 퇴화 쉘 요소를 도입하였으며 반복계산을 통하여 최적의 두께분포를 검색하기 위하여 최적화검색기 DOT를 도입하였다. 마지막으로 경계조건에 따른 판의 최적두께 분포에 대한 정량적인 수치해석결과를 제공하기 위하여 정사각형 판을 최적화에 채용하고 그 결과를 자세히 기술하였다.

  • PDF

$\gamma$선(線)(Ir-192)이 연박(鉛箔)두께의 증감(增減)에 따른 필름감도(感度) 효과(效果) (A Study on Film Sensitive Effect Influenced by ${\gamma}-ray$(Ir-192) Depending on Thickness of Lead Foil)

  • 주광태
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제2권1호
    • /
    • pp.95-99
    • /
    • 1979
  • When the ${\gamma}-ray$ of average energy 375KeV emitted by Ir-192 is exposed to each film through lead foil with various thickness, the film sensitivity will be different according to the thickness of lead foil and film type. The results on the study, different density and sensitive ratio appeared depending on exposed time and film type, but was made on the following common points. 1. The effect of film sensitivity by the front lead foil showed rapid increase up to the thickness of more or less 0.03mm, and the thicker lead foil was decreased more in the thickness of about $0.05{\sim}0.09mm$. 2. The effect of film sensitivity by the back lead foil was increased up to around of $0.03{\sim}0.08mm$ thickness, the maximum sensitivity was obtained in the thickness of more than $0.03{\sim}0.08mm$ without any change in the above effect. 3. The sensitivity of front lead foil was higher than that of back lead foil in thin lead foil with about 0.127mm thickness, but the sensitivity of back lead foil was higher than that of front lead foil when thickness became thicker.

  • PDF

인천 소래 간석지내 두개의 칠면초 ( Suadeda japonica ) 개체군간의 차이에 관하여 (Difference of Suaeda japonica Populations from two Different Habitats in Sorae, Incheon, Korea)

  • Lee, Kun-Seop;Oh, Kye-Chil
    • The Korean Journal of Ecology
    • /
    • 제12권3호
    • /
    • pp.133-144
    • /
    • 1989
  • The morphology and flowering time of two Suaeda japonica populations from different habitats, the creek and the bank of the mudflat in Sorae, were surveyed. And standard transplantation and reciprocal transplantation were carried out to determine whether their characteristics were genetically fixed or not. Also soil sample of these habitats were analyzed. The amounts of loss on ignition, maximum field capacity, total nitrogen, exchangeable calcium and potassium, and soluble phosphorus were found to be significantly different between two habitats. Leaf thickness, leaf width, leaf length, stem height number of branches, and number of seeds were significantly different between plants of two populations. And flowering times of two populations did not overlap. According to the results of transplantation, leaf width, leaf thickness, and flowering times were the same as those at their original habitat. But the stem lenght, leaf lenght, number of branches and unmber of seeds were not. Therefore, the differences in the leaf length, leaf thickness, and flowering time seemed to bo genetically fixed. It were suggested that the creek bank populations of Suaeda japoinica were to be considered as different ecotypes.

  • PDF

이종두께 강판의 $CO_2$ 레이저 용접 및 성형성 ($CO_2$ Laser Beam Welding and Formability of Steel Plates with Different Thicknesses)

  • 서정;한유희;김정오;이영신
    • Journal of Welding and Joining
    • /
    • 제14권1호
    • /
    • pp.82-91
    • /
    • 1996
  • The maximum butt-joint gap size in $CO_2$ laser beam welding of SAPH steel plates with different thicknesses and its bending formability were studied. In the range of the gap size$\geq$0.1mm, the optimal butt welding speed was faster than that of no gap (air gap) condition. This behaviour was independent on the difference of thickness at any combination. Also, the allowable gap size in steel plates with different thicknesses was larger than with same thicknesses. In the range of $T/T_0$(bead shape) $\geq$ 0.8, good bending formability was obtained at any combination of thickness. The formability was improved by reducing the hardness in weld bead using pre-heating process. Finally, FEM result of the laser beam welded underframe with different thicknesses was compared to that of the conventional spot welded underframe.

  • PDF