• 제목/요약/키워드: Difference sets

검색결과 581건 처리시간 0.03초

DECOMPOSITIONS OF COMPLETE MULTIPARTITE GRAPHS INTO GREGARIOUS 6-CYCLES USING COMPLETE DIFFERENCES

  • Cho, Jung-R.;Gould, Ronald J.
    • 대한수학회지
    • /
    • 제45권6호
    • /
    • pp.1623-1634
    • /
    • 2008
  • The complete multipartite graph $K_{n(2t)}$ having n partite sets of size 2t, with $n\;{\geq}\;6$ and $t\;{\geq}\;1$, is shown to have a decomposition into gregarious 6-cycles, that is, the cycles which have at most one vertex from any particular partite set. Complete sets of differences of numbers in ${\mathbb{Z}}_n$ are used to produce starter cycles and obtain other cycles by rotating the cycles around the n-gon of the partite sets.

Sodium polyanethol sulfonate의 혈액배양에서의 Salmonella typhi 분리에 대한 영향 (Effect of sodium polyanethol sulfonate on the isolation of Salmonella typhi from blood culture)

  • 정윤섭
    • 대한미생물학회지
    • /
    • 제9권1호
    • /
    • pp.13-18
    • /
    • 1974
  • Blood is one of the most important clinical specimens for the isolation of bacteria. A rapid isolation and a high isolation rate of bacteria are very important in blood culture because bacteremic patients are mostly in grave condition. Various blood culture media which support growth of most fastidious bacteria are available commercially. However, growth of bacteria are frequently delayed because of antibacterial activity of blood. Sodium polyanethol sulfonate(Liquoid) has been reported to inactivate the antibacterial substance and disrupt phagocytic cells. The beneficial effect of SPS is well recognized in the isolation of gram-positive bacteria. However, the effect does not seem to be prominent for gram-negative bacilli isolation mainly due to the rapidity of their growth. It has been experienced with Sal. typhi that the growth is much slower than that of other gram-negative bacilli. For the rapid growth of the organism, use of bile broth has been recommended. Although Sal. typhi is the most frequently isolated organism at present, about one half of total isolates are other organisms and, in case bile broth is used, other media which support growth of these organisms should be used together. Fluid thioglycollate medium(FTM) which is always used in blood culture to isolate anaerobes is inferior to brain heart infusion(BHI) for the isolation of aerobes. This study was done to determine the effect of SPS on the isolation of Sal. typhi from blood. During the Sep. 1973 to Sep. 1974 study period, 2460 blood cultures were made from the Severance hospital patients: BHI and FTM sets 1431 specimens, BHI with SPS(0.05%) and FTM sets 396 specimens, BHI and FTM with SPS sets 359 specimens, BHI and BHI with SPS sets 274 specimens. Mean incubation time required for the macroscopic detection of growth of Sal. typhi were 3.5 days on BHI and 2.7 days on BHI with SPS. The 0.8 day difference was statistically significant. On FTM the mean incubation time was 3.8 days while it was 2.9 days on FTM with SPS. The 0.9 day difference was statistically significant. The result on BHI with and without SPS sets showed faster growth on BRI with SPS in 7 specimens and slower growth in one specimen and the remaining 12 showed growth at the same time. These specimens had mean incubation time of 3.2 days on BHI and 2.3 days on BHI with SPS. The 0.9 day difference was statistically significant. This study indicates beneficial effect of SPS for the rapid isolation of Sal. typhi from clinical blood specimens.

  • PDF

3D Sample Module을 활용한 스커트 원형 연구 -Plus-size 여성을 중심으로- (A Study on the Basic Skirt using a 3D Sample Module - For Plus-sized Women -)

  • 성옥진;하희정
    • 복식문화연구
    • /
    • 제14권2호
    • /
    • pp.271-285
    • /
    • 2006
  • The purpose of this study was to develop a new basic skirt pattern for 4 lower body types of Plus-sized women. To reduce a time and economic loss about putting it on, This study applied a 3D sample module in the course to develop a basic skirt pattern which is fit, functional and beautiful. A data analysis used the SPSS 11.0 statistics program. To verify the difference, This study used the variance analysis and Duncan's test for the postmortem verification. The result was as follows. To reflect a feature according to an abdomen projection and hip projection, we added the maximum hip circumference to the waist circumference and hip circumference for necessary for a skirt draft item. The front hip circumference sets to the H/4+1cm(ease)+D/4. The back hip circumference set to the H/4+0.5cm(ease)+D/4. The D is the hip circumference in the maximum hip circumference to subtract. The front waist circumference sets to the W/4+0.5cm(ease)+0.5cm(A front and back's difference)+D/4. The back waist circumference sets to the W/4+0.5cm(ease)-0.5cm(A front and back's difference)-D/4. Compare with 4 lower body types of Plus-sized Women, A type 2 and type 4 abdomen projections are bigger. We raised a front waistline of skirt pattern to a 0.3cm upside, and take about 1.3cm down the skirt length from a developed skirt pattern. Consequently, the appearance of a front skirt length was improved with a side skirt length.

  • PDF

Assessment of Diffusion-Weighted Imaging-FLAIR Mismatch: Comparison between Conventional FLAIR versus Shorter-Repetition-Time FLAIR at 3T

  • Goh, Byeong Ho;Kim, Eung Yeop
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권2호
    • /
    • pp.88-94
    • /
    • 2016
  • Purpose: Fluid-attenuated inversion recovery (FLAIR) imaging can be obtained faster with shorter repletion time (TR), but it gets noisier. We hypothesized that shorter-TR FLAIR obtained at 3 tesla (3T) with a 32-channel coil may be comparable to conventional FLAIR. The aim of this study was to compare the diagnostic value between conventional FLAIR (TR = 9000 ms, FLAIR9000) and shorter-TR FLAIR (TR = 6000 ms, FLAIR6000) at 3T in terms of diffusion-weighted imaging-FLAIR mismatch. Materials and Methods: We recruited 184 patients with acute ischemic stroke (28 patients < 4.5 hours) who had undergone 5-mm diffusion-weighted imaging (DWI) and two successive 5-mm FLAIR images (no gap; in-plane resolution, $0.9{\times}0.9mm$) at 3T with a 32-channel coil. The acquisition times for FLAIR9000 and FLAIR6000 were 108 seconds (generalized autocalibrating partially parallel acquisitions [GRAPPA] = 2) and 60 seconds (GRAPPA = 3), respectively. Two radiologists independently assessed the paired imaging sets (DWI-FLAIR9000 and DWI-FLAIR6000) for the presence of matched hyperintense lesions on each FLAIR imaging. The signal intensity ratios (area of DWI lesion to contralateral normal-appearing region) on both FLAIR imaging sets were compared. Results: DWI-FLAIR9000 mismatch was present in 39 of 184 (21.2%) patients, which was perfectly the same on FLAIR6000. Three of 145 patients (2%) with DWI-matched lesions on FLAIR9000 had discrepancy on FLAIR6000, showing no significant difference (P > 0.05). Interobserver agreement was excellent for both DWI-FLAIR9000 and DWI-FLAIR6000 (k = 0.904 and 0.883, respectively). Between the two FLAIR imaging sets, there was no significant difference of signal intensity ratio (mean, standard deviation; $1.25{\pm}0.20$; $1.24{\pm}0.20$, respectively) (P > 0.05). Conclusion: For the determination of mismatch or match between DWI and FLAIR imaging, there is no significant difference between FLAIR9000 and FLAIR6000 at 3T with a 32-channel coil.

CCM을 이용한 변퇴색 견뢰도 등급의 판정 및 New Fastness Formula에 관한 연구 (A Study on the Measurement of Colour Fastness by CCM and New Fastness Formula)

  • 홍민기;박주영;박영미;구강;허민우;김삼수
    • 한국염색가공학회지
    • /
    • 제18권2호
    • /
    • pp.15-23
    • /
    • 2006
  • A new fastness formula based on CIEDE2000 color-difference formula is developed by B. Rigg and his coworkers. It is very simple to calculate fastness grade for color change than ISO 105-A05 fastness formula based on CIELAB color-difference formula. Sample pair sets which cover a wide range color space were accumulated from NCS(Natural Color System) color book. For those sample pair sets, visual measurement experiment and instrument measurement experiment of fastness grade were carried out and each performance of ISO 105-A02 fastness formula and newly developed fastness formula was compared through degree of agreement for visual measurement result. Newly developed fastness formula indicated improved performance for measuring fastness grade but current ISO fastness formula for assessing change in color, ISO 105-A05, was confirmed that it's performance is inadequate to measure fastness grade. Then fastness formulae were examined more closely according to particular color spaces and the correlation of hue, lightness and chrom for measuring fastness grade was also considered in this study.

HCBKA를 이용한 Interval Type-2 퍼지 논리시스템 기반 예측 시스템 설계 (Prediction System Design based on An Interval Type-2 Fuzzy Logic System using HCBKA)

  • 방영근;이철희
    • 산업기술연구
    • /
    • 제30권A호
    • /
    • pp.111-117
    • /
    • 2010
  • To improve the performance of the prediction system, the system should reflect well the uncertainty of nonlinear data. Thus, this paper presents multiple prediction systems based on Type-2 fuzzy sets. To construct each prediction system, an Interval Type-2 TSK Fuzzy Logic System and difference data were used, because, in general, it has been known that the Type-2 Fuzzy Logic System can deal with the uncertainty of nonlinear data better than the Type-1 Fuzzy Logic System, and the difference data can provide more steady information than that of original data. Also, to improve each rule base of the fuzzy prediction systems, the HCBKA (Hierarchical Correlation Based K-means clustering Algorithm) was applied because it can consider correlationship and statistical characteristics between data at a time. Subsequently, to alleviate complexity of the proposed prediction system, a system selection method was used. Finally, this paper analyzed and compared the performances between the Type-1 prediction system and the Interval Type-2 prediction system using simulations of three typical time series examples.

  • PDF

Shannon의 정보이론과 문헌정보 (Shannon's Information Theory and Document Indexing)

  • 정영미
    • 한국문헌정보학회지
    • /
    • 제6권
    • /
    • pp.87-103
    • /
    • 1979
  • Information storage and retrieval is a part of general communication process. In the Shannon's information theory, information contained in a message is a measure of -uncertainty about information source and the amount of information is measured by entropy. Indexing is a process of reducing entropy of information source since document collection is divided into many smaller groups according to the subjects documents deal with. Significant concepts contained in every document are mapped into the set of all sets of index terms. Thus index itself is formed by paired sets of index terms and documents. Without indexing the entropy of document collection consisting of N documents is $log_2\;N$, whereas the average entropy of smaller groups $(W_1,\;W_2,...W_m)$ is as small $(as\;(\sum\limits^m_{i=1}\;H(W_i))/m$. Retrieval efficiency is a measure of information system's performance, which is largely affected by goodness of index. If all and only documents evaluated relevant to user's query can be retrieved, the information system is said $100\%$ efficient. Document file W may be potentially classified into two sets of relevant documents and non-relevant documents to a specific query. After retrieval, the document file W' is reclassified into four sets of relevant-retrieved, relevant-not retrieved, non-relevant-retrieved and non-relevant-not retrieved. It is shown in the paper that the difference in two entropies of document file Wand document file W' is a proper measure of retrieval efficiency.

  • PDF

Structural damage detection including the temperature difference based on response sensitivity analysis

  • Wei, J.J.;Lv, Z.R.
    • Structural Engineering and Mechanics
    • /
    • 제53권2호
    • /
    • pp.249-260
    • /
    • 2015
  • Damage detection based on a reference set of measured data usually has the problem of different environmental temperature in the two sets of measurements, and the effect of temperature difference is usually ignored in the subsequent model updating. This paper attempts to identify the structural damage including the temperature difference with artificial measurement noise. Both local damages and the temperature difference are identified in a gradient-based model updating method based on dynamic response sensitivity. The sensitivities of dynamic response with respect to the system parameters and temperature difference are calculated by direct integration method. The measured dynamic responses of the structure from two different states are used directly to identify the structural local damages and the temperature difference. A single degree-of-freedom mass-spring system and a planar truss structure are studied to illustrate the effectiveness of the proposed method.

Latent Heat Flux over the Global Ocean

  • Kubota, Masahisa
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.644-648
    • /
    • 2002
  • Though it was difficult of globally monitor latent heat flux aver the ocean for many years, the situation is rapidly changing by the use of satellite data. Since a bulk formula is used to estimate turbulent heat flux using satellite data, we need wind speed, sea surface temperature and specific humidity data. However, it is not easy to accurately estimate specific humidity using satellite data. Now several algorithms for estimating specific humidity have been proposed and applied to construct latent heat flux data sets. Latent heat flux data sets derived from satellite data such as J-OFURO, HOAPS and GSSTF are available at present. Since the algorithm and used satellite data are not the same between them. the characteristics of each data set may be different. Therefore, it is important to clarify the difference between each data set and investigate the cause of the difference in latent heat flux estimates. In this paper we summarize the present state of the art with regard to the turbulent heat flux estimation by using satellite data. Also we present the comparison results of latent heat flux fields including not only satellite-derived flux fields but also analysis fields.

  • PDF

Comparative Analysis of Morphometric Characteristics of Scorpaenidae and Gobioninae

  • Park, In-Seok;Gil, Hyun Woo;Oh, Ji Su;Choi, Hui Jung;Kim, Chi Hong
    • 한국발생생물학회지:발생과생식
    • /
    • 제19권2호
    • /
    • pp.85-96
    • /
    • 2015
  • Measurements of closely related sets of classical and truss dimensions were analyzed to discriminate species of scorpaenidae including the dark banded rockfish, Sebastes inermis, the black rockfish, S. schlegeli, and gobioninae including the striped shiner, Pungtungia herzi, and the slender shiner, Pseudopungtungia tenuicorpa. The measurements of the dimensions were arc sin square root transformed, and compared as a function of the standard length of each species for statistical analysis. For values of the classical dimensions of the rockfish, 6 were greater for the dark banded rockfish than for the black rockfish, 1 value was smaller for the former, and for 2 values there was no statistically significant difference (P > 0.05). For values of the classical dimensions of the shiners, 9 values were greater for the striped shiner than for the slender shiner, 2 values were smaller for the former, and for 1 value there was no statistically significant difference (P > 0.01). For values of the truss dimensions of the rockfish, 6 were greater for the dark banded rockfish than for the black rockfish, 1 was smaller for the former, and for 4 values there was no statistically significant difference (P > 0.05). For values of the truss dimensions of the shiners, 13 values were greater for the striped shiner than for the slender shiner, 3 values were smaller for the former, and for 6 values there was no statistically significant difference (P > 0.01). The dimension sets used in this study may be useful as taxonomic indicators for discriminating among fish species in Korea.