• 제목/요약/키워드: Difference of Generation

검색결과 1,390건 처리시간 0.031초

Performance inspection of smart superconducting fault current controller in radial distribution substation through PSCAD/EMTDC simulation

  • MassoudiFarid, Mehrdad;Shim, Jae Woong;Lee, Jiho;Ko, Tae Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • 제15권4호
    • /
    • pp.21-25
    • /
    • 2013
  • In power grid, in order to level out the generation with demand, up-gradation of the system is occasionally required. This will lead to more fault current levels. However, upgrading all the protection instruments of the system is both costly and extravagant. This issue could be dominated by using Smart Fault Current Controller (SFCC). While the impact of Fault current Limiters (FCL) in various locations has been studied in different situations for years, the performance of SFCC has not been investigated extensively. In this research, SFCC which has adopted the characteristics of a full bridge thyristor rectifier with a superconducting coil is applied to three main locations such as load feeder, Bus-tie position and main feeder location and its behavior is investigated through simulation in presence and absence of small Distributed Generation unit (DG). The results show a huge difference in limiting the fault current when using SFCC.

Performance and Flow Characteristics Analyses of Diaphragm Seals for Large Power-Generation Steam Turbines (대형 발전용 스팀터빈 다이아프램 시일의 성능 및 유동특성 해석)

  • Park, Jun-Young;Lee, An-Sung;Kim, Byung-Ok;Kim, Young-Cheol
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2612-2615
    • /
    • 2008
  • Diaphragm seals have great effects on the performance of large power-generation steam turbines. Hence, it is important to decrease the leakage flow through the diaphragm seals and understand the flow characteristics within the diaphragm seals. In this study, numerical analysis was carried-out with the seals of large one-body type diaphragms developed by a domestic company. CFX, which is a commercial CFD code, was used to analyze the performance and flow characteristics of the diaphragm seals for three difference clearance cases. The results of numerical analysis show variations in the performance and flow characteristics according to the changes of labyrinth seal clearance.

  • PDF

An Investigation Into the Impact of Limiting Carbon Emissions on the Korean Power System and the Electricity Market

  • Kim, Changseob;Park, Hyeongon
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1038-1045
    • /
    • 2017
  • To address mounting concerns over global warming, the Paris Agreement was reached in December 2015, which aims to limit the increase in global average temperature. South Korea has set a highly ambitious target to reduce emissions and submitted an Intended Nationally Determined Contribution (INDC). Based on the INDC, we investigated the impact of limiting carbon emissions on the power system and the electricity market in Korea. Through detailed simulations on assumed plausible scenarios, this work highlights a) the effects of different carbon emission targets on the annual carbon emission volumes, generation costs, and carbon price; b) the generation mix changes induced by carbon emission limits; and c) the difference in system marginal price and payments for generator owners that carbon emission constraint creates in electricity markets under three different pricing rules.

A Study on Requirement of Nuclear Power Plant Load Following Operation Condition Considering Power System Security (계통 안전성을 고려한 원자력발전의 부하추종 요건연구)

  • Lee, Hyun-Chul;Baek, Young-Sik;Lee, Geun-Joon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제61권11호
    • /
    • pp.1565-1570
    • /
    • 2012
  • Nuclear power generation is increasing domestic power supply ratio by lower CO2 emission and fuel prices. Currently, nuclear power generator has been operated with maximum power output. Therefore, nuclear power generator could be no effect to managing the reactive power reserve on power system. The reactive power reserve is calculated to the difference between maximum facility and operation generation capacity of the power system. This paper was proposed that load following of nuclear power is control by using 15-bus power system model. In the simulation result, power system is shown to safety state by operating load following of nuclear power generator. This method has be improved the supplied reliability through economic and efficient operation.

Selection Efficiency of Resistant Tobacco Plants to Bacterial wilt Disease Using Two Haploid Methods (반수체 육종법을 이용한 잎담배 세균성마름병 저항성 개체 선발의 효율성 비교)

  • 정윤화
    • Journal of the Korean Society of Tobacco Science
    • /
    • 제15권2호
    • /
    • pp.137-144
    • /
    • 1993
  • The present study was conducted to compare the efficiency of individual plant selection for resistance to bacterial wilt with 30 dihaploid lines derived by anther culture and Nicotiana africana method in Fl and F2 generation from a cross between Bright Yellow 4 (BY4) and NC95. F2 dihaploid lines were selected from bacterial wilt disease resistant plants screened under the naturally infested filed conditions. The populations of FB - ADH and FB MDH derived from F2 individual plants with bacterial wilt resistance showed higher resistance to the disease than the populations of Fl - ADH and Fl - MDH, respectively, and no difference for the disease resistance appeared by the haploid deriving method within a generation.

  • PDF

Non volatile memory device using mobile proton in gate insulator by hydrogen neutral beam treatment

  • Yun, Jang-Won;Jang, Jin-Nyeong;Hong, Mun-Pyo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.192.1-192.1
    • /
    • 2015
  • We demonstrated the nonvolatile memory functionality of nano-crystalline silicon (nc-Si) and InGaZnOxide (IGZO) thin film transistors (TFTs) using mobile protons that are generated by very short time hydrogen neutral beam (H-NB) treatment in gate insulator (SiO2). The whole memory fabrication process kept under $50^{\circ}C$ (except SiO2 deposition process; $300^{\circ}C$). These devices exhibited reproducible hysteresis, reversible switching, and nonvolatile memory behaviors in comparison with those of the conventional FET devices. We also executed hydrogen treatment in order to figure out the difference of mobile proton generation between PECVD and H-NB CVD that we modified. Our study will further provide a vision of creating memory functionality and incorporating proton-based storage elements onto a probability of next generation flexible memorable electronics such as low power consumption flexible display panel.

  • PDF

Generation Forecast for Integrating Sihwa Tidal Power into Power Systems (시화 조력발전 접속에 따른 발전량 예측)

  • Kim, Kyu-Ho;Song, Kyung-Bin;Kwon, Seok-Kee;Kim, Tae-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.375-377
    • /
    • 2006
  • This paper presents a method to calculate generation power for integrating Sihwa tidal power into power systems. The sea levels of 1 minute interval using cubic interpolation based on the forecasted levels of high and low water offered from Nori(National Oceanographic Research Institute) are calculated. If the sea level is greater than the lake level and the difference between sea level and lake level at high tide is over the default value, it begins to calculate the tidal power. It is seen that tidal power can supply power to demand side stably and economically from assessment of effect for integrating tidal power into power systems.

  • PDF

A Study on the Energy Harvesting according to the porosity of Perforated Panel (타공 패널의 다공률에 따른 에너지 하베스팅에 관한 연구)

  • Park, Ha-Jun;Lee, Min-Hyup;Yoo, Moo-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.113-114
    • /
    • 2023
  • As the available resources are gradually depleted, interest in renewable energy is increasing. Various energy harvesting technologies are emerging, and energy harvesting using solar, solar, and wind power is used in the highest range. Depending on the abnormal climate, solar heat and solar power differ in energy harvest, but the wind is fixed compared to the sun. Therefore, it was intended to maximize the effect of energy harvesting by using the venturi effect, which has a change in wind speed according to the turbine used for wind power generation and wind pressure. Therefore, in this paper, we want to see the difference in the amount of power generated by the turbine after increasing the wind speed using the venturi effect.

  • PDF

A study on the lift-generation mechanism of an insect with tandem wing configuration (두 쌍의 날개를 가지는 곤충의 양력 발생 메커니즘에 대한 연구)

  • Kweon, Ji-Hoon;Choi, Hae-Cheon;Chang, Jo-Won
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.389-394
    • /
    • 2007
  • Numerical simulations are conducted to investigate the mechanism for force generation of an insect with tandem wing configuration. Various stroke amplitudes, stroke plane angles and phase difference between the fore- and hind-wings are considered. The Reynolds number is 150 based on the chord length and maximum translation velocity of the wing. When an insect requires high lift such as takeoff, it flaps its wings in parallel at a lower stroke plane angle and a bigger stroke amplitude than those in the hovering. With wings in counter-stroke, the lift fluctuations decrease, and moreover mean lift force decreases. Interactions among the fore-wing, hind-wing and vortices are examined to explain the force variations

  • PDF

The Characteristics of Discharge and Ozone Concentration for plate type ozonizer with Discharge Area variation (평판형 오존발생기의 방전면적에 따른 방전 및 오존생성특성)

  • Lee, Chang-Ho;Lee, Sang-Keubn;Song, Hyun-Jig;Kim, Jong-Hyun;Youn, Byung-Han;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.346-349
    • /
    • 2007
  • In this paper, the ozonizer is equipped with three electrodes ( two external electrodes, central electrode ), and AC high voltage which has 180[$180^{circ}C$] phase difference is applied to two H V. Ozone discharge and generation charactristics have been investigated in accordance with output voltage of power supply, flow-rate, discharge power. Ozone concentration, generation and yield were proportionally increased with increasing discharge area size.

  • PDF