• Title/Summary/Keyword: Difference Pressure

Search Result 3,940, Processing Time 0.031 seconds

The Effects of the Upright Body Type Exercise Program on Body Balance and Record of Archers

  • Kim, Dong-Kuk
    • Korean Journal of Applied Biomechanics
    • /
    • v.28 no.1
    • /
    • pp.9-18
    • /
    • 2018
  • Objective: This study aimed to analyze how the upright body type exercise program affected body balance and record of archers. This study aimed to prove the effectiveness of upright body type exercise, on this basis, in enhancing the performance of archery players. Method: A total of 14 archers (7 men and 7 women) in B Metropolitan City who had ${\geq}4years$ of career in archery and were given explanation of its contents and purpose before giving spontaneous consent to the experiment were enrolled in the study. The upright body type exercise program was implemented thrice a week for 12 weeks, with higher exercise intensity with time. A resistive pressure sensor, Gaitview AFA-50, was used to measure the foot plantar pressure distribution and analyze quantitative information concerning variation in posture stability and weight shift in dynamic balance of foot plantar pressure in shooting and static balance of plantar pressure with the eyes open and closed and the change in archery record accompanying the change in body balance. Results: As for the differences in foot plantar pressure between before and after participation in the upright body type exercise program, there was no significant difference in static balance of foot plantar pressure with the eyes open, and there was statistically significant difference at the ${\alpha}=.05$ significance level in static balance of foot plantar pressure with the eyes closed or in dynamic balance of foot plantar pressure in shooting. There was statistically significant difference at the ${\alpha}=.05$ significance level in archery record. Conclusion: The upright body type exercise program had positive effects on static and dynamic balance of foot plantar pressure by allowing archers to experience less body sway and physical imbalance in shooting with closed eyes and positive effects on archery record. Thus, the program is expected to help archers correct their posture and perform better.

Analysis of production performance and sensory evaluation for shucking oyster using pressure (압력으로 박신한 굴 생산성능과 관능평가 분석)

  • Ok-sam KIM;Eun-Bi MIN;Doo-jin HWANG;Geum-Bum YOO
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.59 no.1
    • /
    • pp.35-43
    • /
    • 2023
  • Sensory evaluation of shucking pressure, pressure holding time, seeding method, difference in full shucking rate in the aquaculture area and shucking oyster was performed using an ultra-high pressure oyster shucking machine. The reaching time for each target pressure is 2.2-2.4 MPa/sec in the range of 180 MPa to 240 MPa. had a rate of pressure rise. There was a difference of 0.5-1.7℃ in the range of 24-27℃ in the seawater temperature before and after the pressure treatment inside the pressure vessel, but there was no specific increase or decrease in seawater temperature. When only the shucking pressure is increased without the pressure holding time, the critical shucking pressure at which the oyster shell is opened and the flesh is peeled in the range of 200 to 220 MPa. When the critical shucking pressure is reached, the oyster sample in the closed vessel is expected to be shucked by about 40%. If there is no pressure holding time when judged only by full shucking, an increase in pressure of about 1.5 MPa is required to further shuck 3% of the oyster population. The oyster samples cultivated in the south coast of Korea were subject to full shucking under the conditions of 220 MPa shucking pressure and two minutes (120 seconds) of pressure holding time, and the difference in the pressure of the oysters according to the oyster seeding method and the farming area was minute. Finally, the condition of 220 MPa of shucking pressure and three minutes of pressure holding time was the best at 1.52 when the result of the sensory evaluation performed manually was set to 1.0. Next was 1.4 under the conditions of 220 MPa of shucking pressure and one minute of pressure holding time (60 seconds), and 1.3 under the condition of 220 MPa and two minutes of pressure holding time (120 seconds). Therefore, it is considered that the most desirable shucking conditions, considering the efficiency and sensory evaluation results, are the conditions of 220 MPa shucking pressure and two to three minutes of pressure holding time.

Effects of the Selective Eye Movement Program on the Foot Pressure and Balance in Normal Adults (선택적 안구운동 프로그램이 정상성인의 족저압과 균형에 미치는 영향)

  • Lee, Geon-Cheol;Kim, Chi-Hyok;Kim, Myung-Jin;Jung, Go-Woon;Lee, Jae-Cheol;Kim, Ji-Hwan;Lee, Mi-Hwa;Kim, Ji-Sun;Bae, Won-Sik
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.4
    • /
    • pp.425-436
    • /
    • 2011
  • Purpose : The purpose of this study is to identify static, dynamic balance performances and foot pressure after eye movement exercise in normal adults. Method : This study was performed on normal 18 males and 18 females subjects. They were divided into 3 groups using random sampling and executed saccadic eye movement, vestibuloocular eye movement, pursuit vergence eye movement exercise respectively. In order to compare the difference of balance and foot pressure, the subjects were measured before, middle and after eye movement. Balance was examined using the balance master 7.0 version systems. Foot pressure was examined using the gaitview AFA-50. Result : The result are as follows. 1. After first intervention, the difference of the FORM-EC item on MCTSIB variable in the vestibuloocular group was significantly decreased(p<.05) and after second intervention, the difference of the FIRM-EO(p<.05), FORM-EO(p<.01), FORM-EC(p<.01) items on MCTSIB variable in the saccadic group and FORM-EC(p<.05) item in the vestibuloocular group were significantly decreased respectively. 2. After first intervention, the difference of the EPE, MXE items in the saccadic group(p<.05) and RT(p<.05), EPE(p<.01) items in the pursuit vergence group were significantly decreased respectively after second intervention. 3. After first intervention, the difference of the Static A-P(p<.05), L-R(p<.01) and Dynamic A-P(p<.01), L-R (p<.01) items on foot pressure variable in the saccadic group, Dynamic A-P(p<.01) item in the vestibuloocular group and Static A-P(p<.01), Dynamic A-P(p<.05), L-R(p<.01) items in the pursuit vergence group were significantly decreased respectively. 4. After first intervention, the difference of the FORM-EO(p<.05), FORM-EC(p<.01) items and after second intervention, the difference of the FIRM-EO(p<.01) item on MCTSIB variable among three groups was significantly decreased respectively. Conclusion : Selective eye movement exercise program influences balance control ability and foot pressure of normal adults in positive ways.

A Study on the Noise Reduction and Performance Improvement of the Hot Water Distributing System (시스템분배기 소음방지 및 성능개선방안 연구)

  • Kim, Yong-Ki;Lee, Tae-Won;Han, Tae-Su;Yoo, Sun-Hak
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1055-1060
    • /
    • 2009
  • Noise is one of the major environmental problems in human life. But hot water distributers with the flow rate control valve bring about often noise according to the heating control condition in residential buildings. The sound power level increased as the flow rate and pressure difference increased. And thus, experimental analyses for the flow rate control and the pressure difference control were carried out in this study to reduce the noise emitted from the flow rate control valve. As the results, the flow rate control method using a SMA(Shape Memory Alloy)-valve and the flow rate control system using a pressure difference sensor can be expected to control noise in the region of below 50 dB of sound power level.

  • PDF

Experimental Study on Estimation of Oxidation Rate of PM inside of Diesel Particulate Filter (DPF내 포집된 입자상 물질의 산화율 산출을 위한 실험적 연구)

  • Shim, Beomjoo;Park, Kyoungsuk;Jo, Kyuhee;Lee, Hyeongjun;Min, Byeongdu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.2
    • /
    • pp.98-103
    • /
    • 2013
  • Conventional method to estimate mass of particulate matter accumulated in diesel particulate filter is to use pressure difference between upstream and downstream of the filter. Then measured pressure difference should be compared that of clean condition which is no particulate matter accumulated in DPF. During regeneration soot oxidation is also estimated by same method. This methodology, however, has demerit on accuracy because of pressure difference deviation of clean DPFs and pressure difference caused by non-carbon based PM which is different from that of caused by carbon based PM. This study suggests new methodology to estimate accumulated soot oxidation rate through exhaust gas characteristics during regeneration. Results, more high accuracy of soot oxidation was obtained by analysis of relationship between fuel mass and concentration of carbon dioxide and oxygen.

Sports Biomechanical Analysis before and after Applying Weight Belt during Squat Exercise (스쿼트 동작 시 웨이트 벨트 착용 전·후에 따른 운동역학적 분석)

  • LEE, Jeong-Ki;HEO, Bo-Seob;KIM, Yong-Jae;LEE, Hyo-Taek
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.4
    • /
    • pp.893-902
    • /
    • 2016
  • The purpose of this study is to investigate the effect of wearing a weightlifting belt, which is an auxiliary equipment used during squat, by measuring and analyzing biomechanical difference in lower limb and proposing safer and to suggest a more effective exercise method for general population. Selected 8 male participants in their 20s who have not performed regular resistance exercise for at least a year, but have experience of performing squat. The comprehensive method of study is as follows: subjects were notified of the purpose of the study and were told to practice warm-up and the squat motion for the experiment for 20 minutes. When the participant believed they were ready to begin, the experiment was started. At controlled points, foot pressure distribution sensor has been installed. Then left and right feet have been placed on the pressure distribution sensor, from which data for successful squat position that does not satisfy the criteria for failure have been collected and computed with Kwon3D XP program and TPScan program. For data processing of this study, SPSS 21.0 was used to calculated mean (M) and standard deviation (SD) of the analyzed values, and paired t-test has been conducted to investigate the difference before and after wearing the weightlifting belt, with p-value of ${\alpha}<.05$. As for time consumed depending on usage of weightlifting belt in squat, statistically significant difference has been found in P2, which is recovery movement. Lower limb angle depending on usage of weightlifting belt in squat has shown statistically significant difference in E1 foot joint(p<. 001). There has been statistically significant difference in E2 knee joint. Foot pressure percentage depending on usage of weightlifting belt in squat were found to be statistically significant (p<. 01) in both regions of anterior and posterior foot.

Fabrication Process of a Nano-precision Polydimethylsiloxane Replica using Vacuum Pressure-Difference Technique (진공 압력차이법에 의한 나노 정밀도를 가지는 폴리디메틸실록산 형상복제)

  • 박상후;임태우;양동열;공홍진;이광섭
    • Polymer(Korea)
    • /
    • v.28 no.4
    • /
    • pp.305-313
    • /
    • 2004
  • A vacuum pressure-difference technique for making a nano-precision replica is investigated for various applications. Master patterns for replication were fabricated using a nano-replication printing (nRP) process. In the nRP process, any picture and pattern can be replicated from a bitmap figure file in the range of several micrometers with resolution of 200nm. A liquid-state monomer is solidified by two-photon absorption (TPA) induced by a femto-second laser according to a voxel matrix scanning. After polymerization, the remaining monomers were removed simply by using ethanol droplets. And then, a gold metal layer of about 30nm thickness was deposited on the fabricated master patterns prior to polydimethylsiloxane molding for preventing bonding between the master and the polydimethylsiloxane mold. A few gold particles attached on the polydimethylsiloxane stamp during detaching process were removed by a gold selecting etchant. After fabricating the polydimethylsiloxane mold, a nano-precision polydimethylsiloxane replica was reproduced. More precise replica was produced by the vacuum pressure-difference technique that is proposed in this paper. Through this study, direct patterning on a glass plate, replicating a polydimethylsiloxane mold, and reproducing polydimethylsiloxane replica are demonstrated with a vacuum pressure-difference technique for various micro/nano-applications.

Cylinder Pressure based Real-Time IMEP Estimation of Diesel Engines (실린더 압력을 이용한 디젤엔진의 실시간 IMEP 추정)

  • Kim, Do-Hwa;Oh, Byoung-Gul;Ok, Seung-Suk;Lee, Kang-Yoon;SunWoo, Myoung-Ho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.2
    • /
    • pp.118-125
    • /
    • 2009
  • Calculation of indicated mean effective pressure(IMEP) requires high cylinder pressure sampling rate and heavy computational load. Because of that, it is difficult to implement in a conventional electronic control unit. In this paper, a cylinder pressure based real-time IMEP estimation method is proposed for controller implementation. Crank angle at 10-bar difference pressure($CA_{DP10}$) and cylinder pressure difference between $60^{\circ}$ ATDC and $60^{\circ}$ BTDC($DP_{deg}$) are used for IMEP estimation. These pressure variables can represent effectively start of combustion(SOC) and fuel injection quantity respectively. The proposed IMEP estimation method is validated by transient engine operation using a common-rail direct injection diesel engine.

Dynamics Response of a Micro Bubble under Temporal Pressure Variations (시간에 따른 압력변화에 대한 마이크로 기포의 동적 반응)

  • Lee, Woo Min;Lee, Seung Hyun;Sung, Jaeyong;Lee, Myeong Ho
    • Journal of the Korean Society of Visualization
    • /
    • v.12 no.1
    • /
    • pp.13-17
    • /
    • 2014
  • The growth of micro bubble has been simulated under the variation of ambient pressure. The Rayleigh-Plesset equation governs the dynamic growth and collapse of a bubble according to pressure and temperature conditions. The Rayleigh-Plesset equation was solved by 4th-order Runge-Kutta method for wide range of pressure variations. As numerical parameters, the pressure difference between initial and final pressures, and the temporal pressure gradient are changed. The results show that the pressure difference has little effect on the growth rate of the micro bubble in the inertia controlled growth region. On the other hand, the growth rate increases linearly with the increase of the pressure gradient.

A Comparative Study of Blood Pressure According to Cuff Size and Measurement Site (커프크기와 측정부위에 따른 혈압측정치 비교 연구)

  • Song, Mi-Ryeong;Kim, Eun-Kyung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.16 no.1
    • /
    • pp.6-13
    • /
    • 2009
  • Purpose: The purpose of this study was to identify differences in blood pressure according to cuff size and measurement sites of the participants. Method: The participants consisted of 50 women and 50 men whose upper arm circumference was $26\sim30cm$. They had no chronic illness and gave consent to participate. Blood pressure of the wrist was measured in the sitting position, the upper arm with a standard cuff, large and small cuffs were used for measurement in supine position and the thigh in prone position. The data were analyzed with paired t-test using SPSS 12.0 program. Result: The data for the upper arm showed a difference in systolic and diastolic blood pressure depending on the site of measurement. There was a significant difference between measurements with a standard cuff and measurements with large and small cuffs. The systolic blood pressure of the wrist and the thigh were significantly lower than that of the upper arm. Conclusion: These results suggest that the selection of an appropriate cuff is an essential element in ensuring accuracy when measuring blood pressure and differences in systolic blood pressure for the upper arm, wrist and thigh indicate the need to record the measuring site when measuring blood pressure.

  • PDF