• 제목/요약/키워드: Diethyl phthalate

검색결과 35건 처리시간 0.029초

Risk assessment of endocrine disruptors in cosmetics

  • Lee, Jeong-Pyo;Choi, Sang-Sook;Son, Kyung-Hun;Yang, Seong-Jun;Kim, Shin-Ok;Paek, Ock-Jin;Cho, Hyeon-Seo;Kim, Young-Ok
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.403.3-404
    • /
    • 2002
  • Dimethyl phthalate(DMP). diethyl phthalate(DEP), di-n-butyl phthalate (DBP). butyl benzyl phthalate(BBP). bis(2-ethylhexyl)phthalate(DEHP) and di-n-octyl phthalate(DOP) in lotions was determined by gas chromatography. and benzyl benzoate was used as the intermal standard. The separation of the six phthalates and internal standard was optimized, and the optimal analytical conditions were as follows: column. DB-1701 (I.D. 0.25mm): mobile phase. helium: oven temperature 20$0^{\circ}C$ (10 min) ${\rightarrow}10^{\circ}C$/min ${\rightarrow}260^{\circ}C$/min(30min), injector temperature 23$0^{\circ}C$, detector temperature 28$0^{\circ}C$. (omitted)

  • PDF

Extraction of Phthalate Esters in Environmental Water Samples Using Layered-Carbon Magnetic Hybrid Material as Adsorbent Followed by Their Determination with HPLC

  • Wang, Weina;Wu, Qiuhua;Zang, Xiaohuan;Wang, Chun;Wang, Zhi
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권10호
    • /
    • pp.3311-3316
    • /
    • 2012
  • In this paper, a layered-carbon-$Fe_3O_4$ (LC-$Fe_3O_4$) hybrid material was synthesized through a facile one-pot solvothermal method and used as the adsorbent for the preconcentration of some phthalate esters (dimethyl phthalate, diethyl phthalate, diallyl phthalate, diisobutyl phthalate and benzyl butyl phthalate) in water samples. The effects of the adsorbent dosage, extraction time, the solution pH and salinity on the adsorption of the phthalate esters (PAEs) were investigated. The magnetic nanocomposite adsorbent could remove and enrich the PAEs from water samples efficiently. After the adsorption, the analytes were desorbed and then determined by high performance liquid chromatography-ultraviolet detection. Under the optimum conditions, the enrichment factors of the method for the analytes were in the range from 161 to 180. A linear response with peak area as the quantification signal was observed in the concentration range from 0.5 to $100ng\;mL^{-1}$. The limits of detection (S/N = 3) of the method were between 0.08 and $0.1ng\;mL^{-1}$. The method was suitable for the determination of trace phthalate esters in environmental water samples.

Comparison of the Short Term Toxicity of Phthalate Diesters and Monoesters in Sprague-Dawley Male Rats

  • Kwack, Seung-Jun;Han, Eun-Young;Park, Jae-Seok;Bae, Jung-Yun;Ahn, Il-Young;Lim, Seong-Kwang;Kim, Dong-Hyun;Jang, Dong-Eun;Choi, Lan;Lim, Hyun-Jung;Kim, Tae-Hyung;Patra, Nabanita;Park, Kui-Lea;Kim, Hyung-Sik;Lee, Byung-Mu
    • Toxicological Research
    • /
    • 제26권1호
    • /
    • pp.75-82
    • /
    • 2010
  • This study was carried out to investigate the short term toxicity of nine phthalate diesters including di-2(ethylhexyl) phthalate (DEHP), di(n-butyl) phthalate (DBP), di-n-octyl phthalate (DnOP), diethyl phthalate (DEP), butylbenzyl phthalate (BBP), dimethyl phthalate (DMP), di-isodecyl phthalate (DIDP), diundecyl phthalate (DUP), and di-isononyl phthalate (DINP) and five phthalate monoesters including mono- (2-ethylhexyl) phthalate (MEHP), monobutyl phthalate (MBuP), monobenzyl phthalate (MBeP), monoethyl phthalate (MEP), monomethyl phthalate (MMP) and phthalic acid (PA) in Sprague-Dawley male rats. Animals were administered 250 mg/kg/day (monoesters and PA) or 500 mg/kg/day (diesters) of phthalate for two weeks. All animals were examined for body and organ weights, blood hematology, serum biochemistry, and urine analysis. The body weight gain was significantly lower in rats treated with BBP, DBP, DINP, MEHP, MBuP, and PA than that of control. Liver weights were significantly increased in the DEHP, DBP, DnOP, DIDP, and MEHP groups as compared to the control group. Testes weights were significantly decreased only in the DEHP-, DnOP-, and DIDP-treated groups as compared to the control. Significant differences in hematological changes were not observed in any treatment groups. Significant increases in blood glucose levels were observed in the DEHP, MEHP, and MBeP groups. Aspartate aminotransferase (AST) levels were significantly increased in the DBP, DUP, DINP, MBuP, and MBeP groups, whereas alanine aminotransferase (ALT) levels were significantly increased only in the DEHP and MEHP groups. Serum ALP levels were significantly higher in phthalate diester (500 mg/kg/day)-treated rats as compared to control. However, the total cholesterol level was significantly reduced in the DEHP- and DIDP-treated groups, whereas serum triglyceride (TG) levels were higher in the DINP-, MEHP-, and MBuP-treated groups. These results suggest that short term toxicity of phthalate monoesters produces adverse effects as similar to phthalate diesters in Sprague-Dawley rats.

서울시 초등학교 실내 먼지 중 프탈레이트 오염실태 조사 (Phthalates Contamination in Indoor Dust in Elementary Schools in Seoul: A Pilot Study)

  • 이영선;최인자
    • 한국환경보건학회지
    • /
    • 제46권5호
    • /
    • pp.548-554
    • /
    • 2020
  • Objectives: This study is to examine the polyvinyl chloride (PVC) materials in elementary school classrooms and libraries in Seoul, and to investigate phthalate contamination in indoor dust. Methods: PVC material was identified for building materials and furniture using portable x-ray fluorescence (XRF). Phthalates in dust samples (n=19) were extracted by ultrasonic extraction using cyclohexane and analyzed by GC-MS. Results: Diethyl phthalate (DEP), di-n-butyl phthalate (DBP), and Bis (2-ethylhexyl) phthalate (DEHP) were found in all collected dust samples (n=19), and diisonyl phthalate (DINP) was detected in all except for one sample (n=18). The concentration of DEHP (median: 2190 mg/kg) and DINP (2960 mg/kg) were higher than other compounds, suggesting that there are many products in the school that used these compounds. When comparing the phthalate concentration in the classroom (n=11) and library dust (n=8), the total concentration in the classroom (median: 10000 mg/kg) was higher than that in the library (8030 mg/kg). DEHP was the dominant compound in the library. The library is relatively more equipped with PVC furniture (n=83) and most floors are also identified as PVC material, suggesting that floors and furniture made of PVC materials are main sources of DEHP contamination. Conclusions: This study is a pilot survey for investigating phthalate contamination in elementary schools. As a result of the survey, phthalate contamination in elementary school was confirmed. However, further study requires risk assessment of children through analysis of phthalate metabolites in children based on sufficient number of samples and information about the site.

Health Risks Assessment in Children for Phthalate Exposure Associated with Childcare Facilities and Indoor Playgrounds

  • Kim, Ho-Hyun;Yang, Ji-Yeon;Kim, Sun-Duk;Yang, Su-Hee;Lee, Chung-Soo;Shin, Dong-Chun;Lim, Young-Wook
    • Environmental Analysis Health and Toxicology
    • /
    • 제26권
    • /
    • pp.8.1-8.9
    • /
    • 2011
  • Objectives: This study assessed the health risks for children exposed to phthalate through several pathways including house dust, surface wipes and hand wipes in child facilities and indoor playgrounds. Methods: The indoor samples were collected from various children's facilities (40 playrooms, 42 daycare centers, 44 kindergartens, and 42 indoor-playgrounds) in both summer (Jul-Sep, 2007) and winter (Jan-Feb, 2008). Hazard index (HI) was estimated for the non-carcinogens and the examined phthalates were diethylhexyl phthalate (DEHP), diethyl phthalate (DEP), dibutyl-n-butyl phthalate (DnBP), and butylbenzyl phthalate (BBzP). The present study examined these four kinds of samples, i.e., indoor dust, surface wipes of product and hand wipes. Results: Among the phthalates, the detection rates of DEHP were 98% in dust samples, 100% in surface wipe samples, and 95% in hand wipe samples. In this study, phthalate levels obtained from floor dust, product surface and children's hand wipe samples were similar to or slightly less compared to previous studies. The $50^{th}$ and $95^{th}$ percentile value of child-sensitive materials did not exceed 1 (HI) for all subjects in all facilities. Conclusions: For DEHP, DnBP and BBzP their detection rates through multi-routes were high and their risk based on health risk assessment was also observed to be acceptable. This study suggested that ingestion and dermal exposure could be the most important pathway of phthalates besides digestion through food.

초음파 (US)와 다양한 파장범위의 자외선 (UV) 조사에 따른 DEP 분해특성에 관한 연구 (The Study of DEP Degradation Properties by Combination US and UV Lamp of Different Wavelength)

  • 나승민;;신동훈;;김지형
    • 한국환경과학회지
    • /
    • 제21권7호
    • /
    • pp.845-853
    • /
    • 2012
  • Diethyl phthalate (DEP) is widely spread in the natural environment as an endocrine disruption chemicals (EDs). Therefore, in this study, ultrasound (US) and ultraviolet (UVC), including various applied power density (10-40 W/L), UV wavelengths (365 nm, 254 nm and 185 nm) and frequencies (283 kHz, 935 kHz) were applied to a DEP contaminated solution. The pseudo-first order degradation rate constants were in the order of $10^{-1}$ to $10^{-4}\;min^{-1}$ depending on the processes. Photolytic and sonophotolytic DEP degradation rate also were high at shortest UV wavelength (VUV) due to the higher energy of photons, higher molar absorption coefficient of DEP and increased hydroxyl radical generation from homolysis of water. Sonolytic DEP degradation rate increased with increase of applied input power and the dominant reaction mechanism of DEP in sonolysis was estimated as hydroxyl radical reaction by the addition of t-BuOH, which is a common hydroxyl radical scavenger. Moreover, synergistic effect of were also observed for sonophotolytic degradation with various UV irradiation.

PVC포장재에 사용된 가소제에 관한 조사연구 (A Study of Plasticizer in Food and Drug PVC Packaging)

  • 윤미혜;엄미나;도영숙;정홍래;정일형;고환욱;손진석
    • 환경위생공학
    • /
    • 제20권2호
    • /
    • pp.39-46
    • /
    • 2005
  • This study was Performed to survey and evaluate the contents of Plasticizers such as DEP(diethyl phthalate), DPrP(di-n-Phthalate), DBP(di-n-butyl Phthalate), DPP(di-n-pentyl Phthalate), DCHP(dicyclohexyl phthalate), BBP (butylbenzyl phthalate), DEHP(di-(2-ethylhexyl) phthalate) and DEHA(di-(2-ethylheryl) adipate), which are suspected as endocrine disruptors, in food and drug PVC packaging. Tested samples were 5 food wraps, 35 food containers, 40 food and drug packages(type of tablet and capsule) in Gyeonggi-Do area. The contents of DEHA in wrap were 188.9g/kg, 203.1g/kg, 238.4g/kg, 290.9g/kg and 308.3g/kg, respectively, while the other plasticizers were not detected. DEHP was used in 4 samples of food containers and DEHP contents were 4.7g/kg, 30.7g/kg, 35.8g/kg and 53.4g/kg, respectively. In food and drug packaging materials(type of tablet and capsule), the plasticizers were not detected.

PVC Wraps에서 지방함유 식품으로 이행되는 Phthalate esters 및 Di-(2-ethylhexyl) adipate의 동시 분석법 (A Method for Simultaneous Analysis of Phthalate Esters and Di-(2-ethylhexyl) Adipate Migrated from PVC Wraps into Fatty Food)

  • 이광호;전대훈;정동윤;최병희;김성욱;이철원
    • 한국식품과학회지
    • /
    • 제32권6호
    • /
    • pp.1244-1250
    • /
    • 2000
  • 식품에서 내분비계장애추정물질로 의심되는 DEP, DprP, DBP, DPP, BBP, DEHP 및 DCHP 등과 같은 phthalate esters와 DEHA를 동시 정량 분석하였다. GC/FID를 사용하여 지방 함유 식품의 일종인 짬뽕에서 가소제를 정량하기 위한 최적의 분석방법을 검토하였다. Phthalate esters인 DEP, DprP, DBP, DPP, BBP, DEHP, DCHP와 DEHA의 검출한계는 각각 3.5, 5.3, 2.2, 2.2, 7.2, 1.7, 1.9 와 3.0 mg/kg이었다. Acetone/n-hexane(1:1) 추출용매 system을 사용하여 4회 추출하고 HP-1701 column이 장착된 GC/FID를 사용했을때의 phthalate esters인 DEP, DprP, DBP, DPP, BBP, DEHP, DCHP와 DEHA의 회수율이 각각 72.7, 85.9, 91.4, 97.1, 100.8, 103.2, 104.3 및 95.8% 이었다. 3종의 업소용 PVC wrap으로 짬뽕을 각각 덮은채 30분간 shaking(120회/분)한 후 이행되는 가소제 함량을 조사하였다. 3종의 PVC wrap에서 짬뽕으로 DEHA가 각각 577, 706, 770 mg/kg 이행되어 검출되었으며 다른 phthalate esters는 검출되지 않았다.

  • PDF

환경대기 중 프탈레이트 화합물의 농도 측정 (I) - 측정방법 평가와 현장 적용 - (Determination of Phthalates Compounds in the Ambient Atmosphere (I) - Evaluation of a Measurement Method and its Application to a Field Study -)

  • 황윤정;박영화;서영교;서광교;백성옥
    • 대한환경공학회지
    • /
    • 제32권5호
    • /
    • pp.443-454
    • /
    • 2010
  • 프탈레이트 화합물은 PVC 수지 등의 가소제로 널리 사용되며, 내분비계장애 및 돌연변이를 유발하는 물질로서 이에 대한 독성은 널리 알려져 있다. 우리나라에서는 소비자용품이나 음용수에서의 프탈레이트 화합물에 대한 측정 사례는 찾아 볼 수 있으나, 대기환경분야에서의 측정사례는 전무한 실정이다. 본 연구에서는 환경대기 중의 프탈레이트 화합물을 측정하기 위해 고용량샘플러로 시료를 채취한 후 속슬렛 장치로 추출하여 GC/MS로 분석하였다. 일부 시료에 대하여 저용량공기채취법과 고용량공기채취법을 동시에 적용하여 두 측정 결과를 비교 평가하였다. 분석대상 항목은 dimethyl phthalate (DMP), diethyl phthalate (DEP), di-n-butyl phthalate (DBP), butyl benzyl phthalate (BBP), di(2-ethylhexyl) phthalate (DEHP) 및 di-n-octyl phthalate (DOP) 등 6개 항목을 선정하였다. 입자상 시료 채취를 위해서는 석영섬유여지를 사용하였으며, 기체상 시료 채취에는 PUF/XAD-2를 사용하였다. 실험실 정도관리 평가 결과 표준시료에 대한 선형성과 재현성은 우수한 결과를 나타내었으며, 정량검출한계는 항목에 따라 대기 중 농도로 환산하여 0.60~17.84 ng/$m^3$ 수준으로 추정되었다. 또한 실제 현장평가를 위해 2007년 1월과 6월에 시화 반월공단 (정왕2동, 원시동)에서 측정한 결과 비교적 분자량이 작고 끓는점이 낮은 DMP, DEP, DBP는 기체상에 많이 존재하며, DBP 보다 분자량이 크고 끓는점이 높은 DEHP와 DOP는 입자상에 주로 존재하는 것으로 나타났다. DEHP는 45.7 ng/$m^3$ ~ 1012.7 ng/$m^3$, DMP는 7.7 ng/$m^3$ ~ 375.1 ng/$m^3$ 수준으로 검출되었다. 전반적으로 볼 때 환경대기 중의 프탈레이트 화합물 측정에는 고용량시료채취법이 저용량법보다 우수한 것으로 나타났다.

디스크형 고상 추출법과 GC/MS를 이용한 공장폐수 중 반휘발성유기화합물질 분석 (Determination of hazardous semi-volatile organic compounds in industrial wastewater using disk-type solid-phase extraction and GC-MS)

  • 이인정;임태효;허성남;남수경;이재관;천세억
    • 분석과학
    • /
    • 제25권4호
    • /
    • pp.236-241
    • /
    • 2012
  • 낙동강 수계는 중 상류 지역에 대규모 공단이 입지하고 있어 그동안 phenol, 1,4-dioxane, perchlorate 등 유해물질에 의한 수질오염사고가 많이 발생하였다. 본 연구에서는 낙동강 수계에 유출 가능성이 있는 미규제 유해물질 중 반휘발성유기화합물질(semi-volatile organic compoumsds, SVOCs) 10종(dichlorvos, toluene-2,4-diisocyanate, 4,4'-methylenedianiline, 4,4'-methylenebis(2-chloroaniline), diethyl phthalate, di-n-butyl phthalate, butyl benzyl phthaltate, bis(2-ethylhexyl)adipate, benzophenone, 4,4'-bisphenol A)에 대하여 디스크형 고상 추출법과 GC/MS를 이용하여 분석하였으며, 정확도 75.6~110.5%, 정밀도 4.6~12.7%, 회수율 72.4~127.9%의 결과를 얻을 수 있었다. 낙동강 수계에 위치한 하 폐수처리장 및 폐수배출업소 등 공장폐수 시료를 분석한 결과 bis (2-ethylhexyl)adipate, benzophenone, 4,4'-bisphenol A 등 3개 물질이 검출되었다.