• Title/Summary/Keyword: Dielectric strength

Search Result 574, Processing Time 0.034 seconds

An Experimental Study on Evaluation of Compressive Strength in Cement Mortar Using Averaged Electromagnetic Properties

  • Kwon, Seung-Jun;Maria, Q. Feng;Park, Tae-Won;Na, Ung-Jin
    • International Journal of Concrete Structures and Materials
    • /
    • v.3 no.1
    • /
    • pp.25-32
    • /
    • 2009
  • A non-destructive testing (NDT) method for evaluating physical properties of concrete including the compressive strength is highly desirable. This paper presents such an NDT method based on measurement of electromagnetic (EM) properties of the material. Experiments are carried out on cement mortar with different water/cement (W/C) ratios. Their EM properties including the conductivity and the dielectric constant are measured at different exposure conditions and curing periods over a wide frequency range of the EM wave. The compressive strength of these specimens is also tested. It is found that both the conductivity and the dielectric constant increase as the W/C ratio decreases and the curing period increases, which lead strength development in the specimens. A linear correlation is observed between the averaged EM properties over the 5 to 20 GHz frequency range and the measured compressive strength, demonstrating the effectiveness of the EM property-based NDT method in evaluating strength of OPC mortar.

Fabrication of High Density BZN-PVDF Composite Film by Aerosol Deposition for High Energy Storage Properties (상온분말분사공정을 이용한 고밀도 폴리머-세라믹 혼합 코팅층 제조 및 에너지 저장 특성 향상)

  • Lim, Ji-Ho;Kim, Jin-Woo;Lee, Seung Hee;Park, Chun-kil;Ryu, Jungho;Choi, Doo hyun;Jeong, Dae-Yong
    • Korean Journal of Materials Research
    • /
    • v.29 no.3
    • /
    • pp.175-182
    • /
    • 2019
  • This study examines paraelectric $Bi_{1.5}Zn_{1.0}Nb_{1.5}O_7$ (BZN), which has no hysteresis and high dielectric strength, for energy density capacitor applications. To increase the breakdown dielectric strength of the BZN film further, poly(vinylidene fluoride) BZN-PVDF composite film is fabricated by aerosol deposition. The volume ratio of each composition is calculated using dielectric constant of each composition, and we find that it was 12:88 vol% (BZN:PVDF). To modulate the structure and dielectric properties of the ferroelectric polymer PVDF, the composite film is heat-treated at $200^{\circ}C$ for 5 and 30 minutes following quenching. The amount of ${\alpha}-phase$ in the PVDF increases with an increasing annealing time, which in turn decreases the dielectric constant and dielectric loss. The breakdown dielectric strength of the BZN film increases by mixing PVDF. However, the breakdown field decreases with an increasing annealing time. The BZN-PVDF composite film has the energy density of $4.9J/cm^3$, which is larger than that of the pure BZN film of $3.6J/cm^3$.

Dielectric Strength for Imitation Air with Pressure Variation under Uniform and Non-Uniform Fields (평등/불평등 전계하의 제조공기(I-Air)에 대한 압력별 절연파괴강도 특성)

  • Lee, Chang-Uk;Lee, Chang-Hun;Choi, Eun-Hyuck;Lee, Sang-Ho;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.263-266
    • /
    • 2007
  • In this paper approves (AC and DC) high voltage by experimental GIS(Gas Insulated Switchgear) chamber and (AC and DC) power source to study breakdown characteristics by pressure(P) change and change of electrode distance(d) at (AC and DC) high voltage of Imitation I-Air, $N_2$ : $O_2$ = 79(%) : 21[%]) to alternate $SF_6$ and achieved research. Gave P change of I-Air to study I-Air's Dielectric Strength using uniform and non-uniform fields(sphere-sphere and Needle-Plane electrode) and studied relations dielectric strength($V_D$) by each P different d.

  • PDF

Evaluation of Insulating Reliability in Epoxy Composites by DC Dielectric Breakdown Properties (DC 절연파괴 특성을 이용한 Epoxy 복합체의 절연 신뢰도 평가)

  • 임중관;박용필;김정호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.92-95
    • /
    • 2001
  • The dielectric breakdown of epoxy composites used for transformers was experimented and then its data were simulated by Weibull distribution probability. First of all, speaking of dielectric breakdown properties, the more hardener increased the stronger breakdown strength at low temperature because of cross-linked density by the virtue of ester radical. The breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised and the electric field is concentrated. In the case of filled specimens with treating silane, the breakdown strength become much higher Finally, from the analysis of weibull distribution, it was confirmed that as the allowed breakdown probability was given by 0.1[%], the applied field value needed to be under 21.5 [Mv/cm].

  • PDF

Analysis of Electrical Degradation in Epoxy Composites by Dielectric Breakdown Properties (절연파괴 특성을 이용한 Epoxy 복합체의 전기적 열화 분석)

  • 최철호;박용필;임중관
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.414-419
    • /
    • 2002
  • The dielectric breakdown of epoxy composites used for transformers was experimented and then its data were simulated by Weibull distribution probability. First of all, speaking of dielectric breakdown properties, the more hardener increased the stronger breakdown strength at low temperature because of cross-linked density by the virtue of ester radical. The breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised and the electric field is concentrated. In the case of (idled specimens with treating silane, the breakdown strength become much higher Finally, from the analysis of weibull distribution, it was confirmed that as the allowed breakdown probability was given by 0.1[%], the applied field value needed to be under 21.5 MV/cm.

  • PDF

Evaluation of Electrical Degradation in Epoxy Composites by Dielectric Breakdown Properties (절연파괴 특성을 이용한 Epoxy 복합체의 전기적 열화 평가)

  • Lim, Jung-Kwan;Park, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.212-217
    • /
    • 2002
  • The dielectric breakdown of epoxy composites used for transformers was experimented and then its data were simulated by Weibull distribution probability. First of all, speaking of dielectric breakdown properties, the more hardener increased the stronger breakdown strength at low temperature because of cross-linked density by the virtue of ester radical. The breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised and the electric field is concentrated. In the case of filled specimens with treating silane, the breakdown strength become much higher Finally, from the analysis of weibull distribution, it was confirmed that as the allowed breakdown probability was given by 0.1[%], the applied field value needed to be under 21.5 MV/cm.

  • PDF

Electrical Properties and Lifetime Prediction of Epoxy/$SiO_2$Composites with Water Absorption Ageing (흡수열화에 따른 Epoxy/$SiO_2$ 복합체의 전기적 특성 및 수명예측)

  • 김탁용;이덕진;홍진웅
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.9
    • /
    • pp.758-763
    • /
    • 2000
  • Dielectric strength of insulators made of epoxy composites rapidly decreases due to ageing to interfaces between the matric resin and filler particles. The adhesion variation of interfaces caused by moisture absorption also alters electrical properties that are the basic characteristics of insulators, particularly, in outdoor use. In this paper, electrical properties of epox/SiO$_2$composites were investigated at boiling absorption condition to observe the influences of moisture. In order to analyze the basic physical properties of samples, scanning electron microscopy and DC, AC and impulse voltage dielectric strength were measured. Also, the breakdown time of samples was measured under AC 6[kV] applied voltage, and the variation of lifetime was verified by using Weibull distribution function.

  • PDF

Evaluation Method II of the Small Current Breaking Performance of SF$_6$-Blown High-Voltage Gas Circuit Breakers (초고압 $SF_6$가스차단기의 소전류 차단성능 해석기술 II)

  • 송기동;이병윤;박경엽;박정후
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.8
    • /
    • pp.384-391
    • /
    • 2001
  • The insulation strength between contacts after current interruption to the transient recovery voltage i.e., the dielectric recovery strength should be estimated for the evaluation of the small capacitive current interruption capability. Many authors have used theoretical and semi-experimental approaches to evaluate the transient breakdown voltage after the current interruption. Moreover, an empirical equation, which is obtained from a series of tests, has been used to estimated the dielectric recovery strength. Un this paper, the theoretical method which is generated from the streamer theory has been applied to real circuit breakers in order to evaluated the interruption capability. The results of analysis have been compared with the test results and the reliability has been investigated.

  • PDF

Temperature dependance of Dielectric strength in Nano-composites (Nano-composites 절연파괴강도의 온도의존성)

  • Lee, Kang-Won;Lee, Hyuk-Jin;Kim, Jong-Hwan;Shin, Jong-Yeol;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.256-257
    • /
    • 2008
  • Recently, with the increase of demand of electricity, electric cable or electric transfer machine are rapidly developed and meet the demand with the extra high voltage and massive capacity, the dangers of electrical accident of insulator are increasing by the electric stress, insulation degradation and insulation breakdown in insulator. In this paper, it is investigated that the temperature dependance of dielectric strength in nano-composites. We obtained that breakdown voltage of 0.4 [wt%] specimens is higher than the other $SiO_2$ content.

  • PDF

Effects of Temperature on Dielectric Breakdown Strength of Epoxy Compounds Filled with Natural Zecolite

  • Kim, You-Jeong;Park, Hyeong-Ki;Kim, Sang-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.544-547
    • /
    • 1999
  • To develop the better insulants. the zeolite particle, which is aluminosilicate mineral, was filled In the DGEBA/MDA/SN epoxy resin system. Dynamic DSC curves of cured specimens with various contents of zeolite were observed and the glass transition temperature(T$_{g}$) was obtained. According to this result, we could carry out the experiment concerned with the dielectric breakdown strength around T$_{g}$ and find the limit temperature for the application of the DDEBA/MDA/SN system filled with natural zeolite. T$_{g}$ increased with the content of zeolite. As the temperature increased, the dielectric breakdown strength decreased rapidly, in the region of T$_{g}$. At the high temperature, the deterioration by electrical stress was activated. The diameter of puncture at the high temperature was larger 7han that at the room temperature.erature.

  • PDF