• Title/Summary/Keyword: Die stone

Search Result 41, Processing Time 0.023 seconds

신개발 국산 부가중합 실리콘 인상재의 젖음성과 기포발생에 관한 비교 연구

  • 조리라;정경호;김경남
    • The Journal of the Korean dental association
    • /
    • v.41 no.1 s.404
    • /
    • pp.35-41
    • /
    • 2003
  • Wettability of addition silicone impression material is very important property for making an accurate restoration. This study examined theimpression quality in clinical condition and the wettability of impression material. Three commercially available addition silicone impression material (Imprint; 3M, USA, Examix; GC, Japan, Perfect; Handae, Korea) were studied. A total of 90 putty/wash impressions of semi-dried premolars and wet molar teeth were examined for void production in impression body. The percentae of the sulcus reproduction ability of each material was calculated from the sulcus depths of cross-sectioned casts from the impressions with stereomicroscope. Three impression materials were used to produce die stone casts from vcid entrapment die. Voids in the stone casts were counted with the stereomicroscpe. From the experiment, the following results were obtained: 1. In direct observation, Imprint showed greatest numbers of void in impression body (P<.001).However, correlations were not found between sulcus reproduction and void production. 2. Sulcus reproduction ability of additional silicone impression material was diminished in order of Imprint, Examix, Perfect. The significant difference was found between Imprint and other material (P<.001). 3. In void entrapment laboratory test, void productions was diminished in order of Examix, Imprint, Perfect. All voids in casts were less in delayed poured cast than immediately poured cast. 4. Especially, the stone pouring time of Perfect impression material should be delayed.

  • PDF

Evaluation of marginal and internal gap of three-unit metal framework according to subtractive manufacturing and additive manufacturing of CAD/CAM systems

  • Kim, Dong-Yeon;Kim, Eo-Bin;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.6
    • /
    • pp.463-469
    • /
    • 2017
  • PURPOSE. To evaluate the fit of a three-unit metal framework of fixed dental prostheses made by subtractive and additive manufacturing. MATERIALS AND METHODS. One master model of metal was fabricated. Twenty silicone impressions were made on the master die, working die of 10 poured with Type 4 stone, and working die of 10 made of scannable stone. Ten three-unit wax frameworks were fabricated by wax-up from Type IV working die. Stereolithography files of 10 three-unit frameworks were obtained using a model scanner and three-dimensional design software on a scannable working die. The three-unit wax framework was fabricated using subtractive manufacturing (SM) by applying the prepared stereolithography file, and the resin framework was fabricated by additive manufacturing (AM); both used metal alloy castings for metal frameworks. Marginal and internal gap were measured using silicone replica technique and digital microscope. Measurement data were analyzed by Kruskal-Wallis H test and Mann-Whitney U-test (${\alpha}=.05$). RESULTS. The lowest and highest gaps between premolar and molar margins were in the SM group and the AM group, respectively. There was a statistically significant difference in the marginal gap among the 3 groups (P<.001). In the marginal area where pontic was present, the largest gap was $149.39{\pm}42.30{\mu}m$ in the AM group, and the lowest gap was $24.40{\pm}11.92{\mu}m$ in the SM group. CONCLUSION. Three-unit metal frameworks made by subtractive manufacturing are clinically applicable. However, additive manufacturing requires more research to be applied clinically.

A STUDY ON THE PHYSICAL CHARACTERISTICS OF THE THREE COMMONLY USED DIE SPACING MATERIALS (여러 가지 Die spacing material의 물리적 성질에 대한 연구)

  • Moon, Hong-Seok;Kim, Jong-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.5
    • /
    • pp.640-650
    • /
    • 1999
  • As an optimal quality of the restorations, there should be a least amount of seating discrepancy between the casting and abutment teeth. However, high viscosity of the cementing medium and its resulting thickness may prevent complete seating of the restoration. The use of die spacing material provides adequate internal relief for the cementing medium. The purpose of this study is to compare the thickness of three commonly used die spacing materials. Materials and Methods: Stone plates were fabricated and divided into 12 sections to be painted with die spacers. Tru-Fit, Whip-Mix and Belle do St. Claire die spacer which are commonly used in dental practice were tested in this study. Each die spacers were painted layer by layer according to the manufacturer's recommendation. The average thickness of each die spacers were measured with light microscope(${\times}100$) and compared between them. Results and Conclusions. A silver-colored Tru-Fit die spacer has the lowest value of thickness without statistical significance comparing with a gold-colored Tru-Fit die spacer and a gray layer of Whip-Mix die spacer has the highest value of thickness without any statistical significance comparing with Belle de St. Claire die spacer. Three and four layers of Tru-Fit die spacer and two layers of Whip-Mix and Belle de St. Claire die spacers seem to be in the acceptable range of thickness of 25 to $45{\mu}m$ for optimal seating of the restorations. The standard experimental design and method should be fur thor evaluated for more consistent and objective results.

  • PDF

Development of an Automated System for Predicting Shape and Volume of Air Pocket on the Draw Die (드로우 금형의 에어 포켓 형상 및 체적예측 자동화 시스템 개발)

  • Jung, Sung-Yuen;Hwang, Se-Joon;Park, Warn-Gyu;Kim, Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.1
    • /
    • pp.72-78
    • /
    • 2008
  • Metal stamping is widely used in the mass-production process of the automobile. During the stamping process, air may be trapped between the draw die and the panel and/or between the punch and the panel. Air pocket rapidly not only increases forming load in the final stage, but also deforms the product just formed by compressive air inside the air pocket in knockout process. To prevent these problems air bent holes are drilled in the die to exhaust the trapped air but all processes associated with air bent holes are performed by empirical know-how of workers in the field due to lack of researches. Therefore this study developed an automated design system for predicting the shape and position, and volume of air pocket on the draw die by using the AutoLISP language under AutoCAD circumstance. The system is able to display the shape of air pocket occurred in the draw die and to calculate automatically its volume by strokes. So it makes a stepping stone to calculate theoretical size of an air bent hole and numbers according to it by predicting and analyzing the position and volume of air pocket. Results obtained from the system enable the designers or manufacturers of the stamping die to be more efficient in this field.

A STUDY ON THE ABRASION RESISTANCE AND SURFACE ROUGHNESS OF THE DENTAL STONES (수종 치과용 석고의 마모저항도 및 표면조도에 관한 비교 연구)

  • Shim, Hye-Won;Yi, Yang-Jin;Cho, Lee-Ra;Chung, Kyung-Ho;Kim, Kyoung-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.2
    • /
    • pp.184-192
    • /
    • 2002
  • The purpose of this study was to investigate the abrasion resistance and surface roughness of conventional dental stones and improved dental stones and newly developed dental stones. Materials included in this study were several dental stones and newly developed dental stone; 2 type III. 6 type IV (including newly developed dental stone). 1 type V Ten specimens for each material, total ninety specimens were made. Each specimen was subjected to 50 complete cycle abrasion under constant load 0.42N at speed or 6mm per sec. The depth after abrasion test was measured for each specimen. Surface roughness before and after abrasion test was compared. The results were as follows ; 1. The resin containing die materials such as Tuff Rock and Resin Rock had superior abrasion resistance. 2. Type IV, V dental stone exhibited greater abrasion resistance than Type III dental stone. 3. The results or the surface roughness showed similar pattern with the abrasion resistance.

Development of a fixing device for slate using press dies (프레스 금형을 이용한 석재판 고정장치 개발)

  • Baek, Seung-Yub;Kim, Sun-Young
    • Design & Manufacturing
    • /
    • v.2 no.4
    • /
    • pp.24-31
    • /
    • 2008
  • The productive products are required diversification of product development and advanced for competitiveness. A lot of methods to fix architecture wrapping panels and stone materials are developed in domestic area very much. In this paper, it is very important that a fixing device of slate and molds were developed to reduce the production cost and improve safety. Therefore new model was suggested to reduce manufacturing cost and structure design and FEM analysis were performed to manufacture die press dies for mass production.

  • PDF

COMPARISON OF STONE SURFACE POROSITIES CAUSED BY HYDROGEN GAS FROM ADDITION SILICONE IMPRESSION MATERIALS (부가 중합형 실리콘 인상재에서 발생하는 수고 기체가 경석고 표면에 미치는 영향)

  • Yoo, So-Jeong;Lee, Keun-Woo;Kim, Kyeung-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.2
    • /
    • pp.349-362
    • /
    • 1996
  • To determine the factors to affect on stone surface porosities produced from hydrogen gas of additional silicone, both putty and syringe type of 7 commercially different additional silicone impression materials(Blend-A-Scon, Correct VPS, Exaflex, Express, Extrude, Provil, Reprosil) were chosen and NewFujirock(GC) was poured into the impressions of detail-reproducing test block at 1, 15, 30, 45, 60 minutes after the impression materials had set and 4 specimens were made for each pouring time, each type of impression material, and each consisency and So, 280 specimens were made in total. The number of surface porosities of same area($2826 mm^2$) which were typically caused by hydrogen gas using the stereoscope(X 7.5) by two observers. Comparison of putty-syringe type and among the impression materials are tested by Kruscal-Wallis method and Mann-Whitney method(p<0.05). The results are as follows. 1. The number of porosities decreased as the pouring time of stone was delayed on both putty and syringe type of additional silicone materials. 2. The putty type significantly produced more porosities than syringe type except for the group of Reprosil.(p<0.05). 3. In case of putty type, the number of porosities increased as following order. Reprosil / Blend-A-Scon and Provil / Correct VPS and Extrude / Express and Exaflex. 4. In case of syringe type, Blend-A-Scon and Extrude produced no porosity and Exaflex and Provil at 30 minites, but Express produced porosities even at 60 minutes and the most. Additional silicone impression material releases hydrogen gas, and that fact can make the resulting die stone model useless. So, to minimize these adverse effects, it is desirable not to expose putty type of additional silicone on critical impression surface because putty type has a tendency to produce more porosities than syringe type. And it is important to have sufficient time before pouring the stone on impression because porosities produce less as time passes after setting of impression material. Also, there are differences among 7 additional silicone impression materials, so it is desirable to choose adequate brand of additional silicone for good laboratory work.

  • PDF

Impact of surface roughness of gypsum materials on adaptation of zirconia cores

  • Kim, Ki-Baek;Kim, Jae-Hong;Kim, Sa-Hak
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.199-206
    • /
    • 2015
  • PURPOSE. The present study investigated the influences of various gypsum materials on the precision of fit of CAD/CAM-fabricated prostheses and analyzed their correlation with surface roughness. MATERIALS AND METHODS. The master model of the mandibular right first molar was replicated, and four experimental groups based on two types of Type IV stone (GC Fujirock EP, Die keen) and two types of scannable stone (Aesthetic-Basegold, Everest Rock) were created to include a total of 40 specimens, 10 in each group. The surface roughness of the working models for the respective experimental groups was measured. Once the zirconia cores had been fabricated, the marginal and internal fits were measured with a digital microscope using the silicone replica technique. The mean and standard deviation of the respective points of measurement were computed and analyzed through the one-way ANOVA and Tukey's HSD test. The correlation between surface roughness and the precision of fit of the zirconia core was analyzed using the Pearson correlation analysis (${\alpha}$=.05). RESULTS. The zirconia cores fabricated from the scannable stone working models exhibited a superior precision of fit as compared to those fabricated from the Type IV stone working models. The correlation analysis results showed a clear positive correlation between surface roughness and the precision of fit of zirconia cores in all of the experimental groups (P<.05). CONCLUSION. The results confirmed that the surface roughness of dental working models has a decisive influence on the precision of fit of zirconia cores.

Influence of mechanical properties of ultra-dental stone on setting methods (경화방법이 치과용 경석고의 기계적 특성에 미치는 영향)

  • Im, Yong-Woon;Hwang, Seong-Sig;Kim, Sa-Hak;Choi, Je-Woo;Jeong, Su-ha;Kim, Si-Chul
    • Journal of Technologic Dentistry
    • /
    • v.40 no.1
    • /
    • pp.33-40
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the influence of mechanical properties of various ultra-dental stone by setting methods. Methods: 240 cylinder specimens($10mm{\times}20mm$) were prepared from three ultra-dental stones(Gemma, Die keen and Fuji rock; n = 80) in accordance with the manufacturers' recommendations. Half of the specimens of each stone(n = 40) were dried in open air within a room temperature; the other half(n = 40) underwent in a silicone rubber mold in open air for 30 minutes and then were dried in a microwave oven for 10 minutes to 600W. Compressive strength(CS), compressive modulus(CM) and diametral tensile strength(DTS) conducted until fracture using Instron 5966 at each of the following periods: 1 and 24 hours from mixing. One-way analysis of variance and Scheffe's post hoc test were performed for statistical comparisons at a significance level of P<.05. Results: The CS and CM values in all dental stone indicated highest after 24h(54.25 MPa < ) than the values for specimens dried in microwave method. The DTS values revealed the highest microwave method. However, in 24h, FJ(Fu-ji rock) and GM(Gemma) had lower mechanical properties than air. Conclusion : Within the limitations of this study, CS did not influence by microwave method but DTS affected according to the setting.

3D Position Measurement & Coping using 2 CCD Cameras (2대의 CCD 카메라를 이용한 3차원 위치측정과 코핑)

  • Kang, Won-Chan;Shin, Suck-Doo;Kim, Young-Dong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.51 no.2
    • /
    • pp.87-93
    • /
    • 2002
  • Accurate acquisition of surface geometries such as machined surfaces, biological surfaces, and deformed parts have been very important technique in scientific study and engineering, especially for system design, manufacturing and inspection. Two-camera method keeps accuracy more than double than mechanical method. In this paper, a new method is studied to acquire 3D geometric data of the small object such as a die in stone model. When the devices, cameras, laser beam and object are in a perfect plane, the calculation is measured by position error 0.025[mm] within. But this paper shows that arbitrarily positioned system can also be used to obtain 3D data. Also, this paper present a method to generate coping surface data with which CAM system can do for milling work.