• Title/Summary/Keyword: Diastolic Velocity

Search Result 69, Processing Time 0.03 seconds

Effect of Seven Points of CVA Acupuncture on Cerebral Blood Flow (중풍칠처혈(中風七處穴) 자침(刺鍼)이 뇌혈류(腦血流)에 미치는 영향)

  • Lee, Sun-ho;Shin, Kyung-ho;Kim, Jong-uk
    • Journal of Acupuncture Research
    • /
    • v.21 no.3
    • /
    • pp.83-97
    • /
    • 2004
  • Objective : This study was performed to evaluate the effect acupuncture on cerebral blood flow by Transcranial Doppler Ultrasonography(TCD). Methods : Monitoring of TCD was examined in stroke patients before and after acupuncture on seven points of CVA. Mean Velocity, pulsatility index, systolic velocity, diastolic velocity values are analyzed from TCD at middle cerebral artery. Results : The results showed a insignificant(p>0.05: Paired T-test) decrease in mean velocity, pulsatility index, systolic velocity, diastolic velocity, which was measured at normal middle cerebral artery. The results showed a significant($p{\leq}0.05$: Paired T-test) decrease in mean velocity, pulsatility index, systolic velocity, which was measured at injuried middle cerebral artery, except diastolic velocity. Conclusion : These results suggest that acupuncture could have a specific effect on injuried cerebral artery.

  • PDF

Evaluation of Plasma NT-proBNP Concentration in Dogs with Chronic Mitral Valve Insufficiency (개의 만성 이첨판 폐쇄부전증 환자군에서 혈장 NT-proBNP 농도 평가연구)

  • Lee, Seunggon;Hyun, Changbaig
    • Journal of Veterinary Clinics
    • /
    • v.30 no.3
    • /
    • pp.151-158
    • /
    • 2013
  • This study aimed to evaluate the plasma concentration of NT-proBNP in dogs with different stages of heart failure by chronic mitral valve insufficiency (CMVI). Fifty small-breed dogs with CMVI and 7 healthy control dogs without cardiac disease and critical systemic diseases were included in the study population. As a preliminary study, we compared the plasma concentrations of N-terminal pro-brain natriuretic peptide (NT-proBNP) and the echocardiographic parameters between dogs of the International Small Animal Cardiac Health Council (ISACHC) classes. Then, we evaluated the associations between NT-proBNP and echocardiographic parameters. Plasma NT-proBNP levels showed a significant difference among the ISACHC groups. In the comparison between echocardiographic parameters and NT-proBNP, NT-proBNP were found to be associated with left atrium/aorta (LA/AO), early diastolic transmitral flow (E) velocity, late diastolic transmitral flow (A) velocity, end diastolic volume index (EDVI). Our study found plasma NT-proBNP might be useful to predict the disease progression in dogs with CMVI.

Effect of Paekoe(GV20) Acupuncture on Cerebral Blood Flow (백회혈 자침이 뇌혈류에 미치는 영향)

  • Lee Hong-Min;Cheong Byung-Shik;Yun Hyoung-Seok;Cho Seong-Gyu;Lee Sang-Hoon;Jun Hyung-Joon;Nam Sang-Soo;Kim Yong-Suk;Lee Joo-Hyung
    • Journal of Acupuncture Research
    • /
    • v.18 no.6
    • /
    • pp.105-113
    • /
    • 2001
  • Objective : This study was performed to evaluate the effect of acupuncture on cerebral blood flow by Transcranial Doppler Ultrasonography(TCD) Method : Monitoring of TCD was examined in 11 healthy women volunteer(mean $age:\;24.5{\pm}2.9\;\;years$) before, during and after acupuncture on Paekoe(GV20). Mean velocity, pulsatility index, systolic velocity and diastolic velocity values are analyzed from DWL. MDX4 at different depths of both middle cerebral artery. Results : The results showed a significant(p<0.05; Friedman test & Wilcoxon signed ranks test) increase in mean velocity, systolic velocity and diastolic velocity decrease in pulsatility index, which was measured at different depths of both middle cerebral artery. Conclusion : These results suggest that acupuncture could have a specific effect on cerebral blood flow.

  • PDF

Is There a Difference in Blood Flow Velocity between Bilateral Common Carotid Arterises in Community-Dwelling Elderly with Unilateral Chewing Habit and Forward Head Posture?: An Observational Cross-Sectional Study

  • Bae, Youngsook
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.1
    • /
    • pp.1954-1959
    • /
    • 2020
  • Background: Due to aging, blood flow rate decreases, also posture and chewing habit may be changed. Objective: To identify that changes in blood velocity in the common carotid arteries (CCAs) in old persons with unilateral chewing habit (UCH) and forward head posture (FHP) in the elderly. Design: An observational cross-sectional study. Methods: Chewing habits, FHP, and CCAs velocities were assessed in 85 elderly subjects. Chewing habits were measured by visual observation. CCAs measured the peak systolic velocity (PSV), end-diastolic velocity (EDV), minimum diastolic velocity, and resistivity index. The subjects were divided into UCH and bilateral chewing habit groups depending on chewing habit. The subjects were also divided into >49 degrees and <49 degrees for comparison of blood flow between the left and right CCAs. Results: In the UCH, the chewing side had significantly higher EDV (P=.003), PSV (P=.023) than the non-chewing side. There was no significant difference in velocity between the CCAs in the FHP. Conclusion: This study shows that the blood flow velocity of the chewing side of UCH was higher, and unilateral chewing affects the CCAs velocity and thus highlight the importance of chewing habit in the elderly than head posture.

Transcranial Doppler Ultrasonography Monitoring during Head-up Tilt Test in Patients with Recurrent Syncope and Presyncope (반복적인 실신 및 실신전환자의 기립경사 검사시 경두개 초음파 감시)

  • Cho, Soo-Jin;Lee, Kwang-Ho;Chung, Chin-Sang
    • Annals of Clinical Neurophysiology
    • /
    • v.1 no.1
    • /
    • pp.64-69
    • /
    • 1999
  • Background : Syncope was defined as transient loss of consciousness and postural tone. The mechanisms of changes in cerebral hemodynamics during syncope have not been fully evaluated. Transcranial Doppler Ultrasonography can continuously monitor the changes in cerebral hemodynamics during head-up tilt (HUT). TCD could reveal the different patterns of changes in cerebral hemodynamics during syncope. Syncope without hypotension or bradycardia could be detected by TCD. We investigated the changes in cerebral blood flow velocity during HUT using TCD in 33 patients with a history of recurrent syncope or presyncope of unknown origin. Methods & Results : The positive responses were defined as presyncope or syncope with hypotension, bradycardia, or both. During HUT without isoproterenol infusion, there were a $86{\pm}23%$ drop in DV and a $41{\pm}34%$ drop in SV in 5 patients with positive reponses, and mean changes in those were less than 10% in patients with negative reponses (p=.00, p=.00). During HUT with isoproterenol infusion, TCD showed a $80{\pm}18%$ drop in diastolic velocity in 14 patients with positive reponses, and a $47{\pm}10%$ drop in that in patients with negative reponses (p=.00), however the change in systolic velocity did not differ. TCD showed three patterns during positive responses; loss of all flow, loss of end diastolic flow, and a decrease in diastolic velocity. Loss of consciousness occurred in the patients with loss of all flow or end-diastolic flow during positive reponses. Conclusions : TCD shows different patterns of changes in cerebral hemodynamics during HUT. TCD can be used to investigate the pathophysiology of neurocardiogenic syncope.

  • PDF

The Correlation of Pulse Wave Velocity and Atherosclerotic Risk Factor in Stroke Patients

  • Jin, Bok Hee;Han, Min Ho
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.47 no.1
    • /
    • pp.28-34
    • /
    • 2015
  • Pulse wave velocity (PWV) is used to non-invasively estimate the severity of arteriosclerosis by measuring arterial stiffness. Increased arterial stiffness measured by PWV stands for progressive arteriosclerosis and is caused by atherosclerotic risk factors. This study is focused on how brachial-ankle pulse wave velocity (baPWV) is related to the leading risk factors for arteriosclerosis or atherosclerosis. Subjects were 114, 69 males and 45 females who are in 60's and had baPWV test for acute stroke. The results are as follows: the group with increased arterial stiffness showed significant increase in HbA1c, total cholesterol, BSBP (brachial artery systolic blood pressure), BDBP (brachial artery diastolic blood pressure), CSBP (central artery systolic blood pressure), CDBP (central artery diastolic blood pressure), augmentation index (AIx) and diabetes mellitus. Correlation analysis between baPWV and atherosclerotic risk factor showed significant relationship in age, HbA1c, LDL cholesterol, BSBP, BDBP, CSBP, CDBP and augmentation index. baPWV was independently related to age and BSBP in multiple linear regression analysis. The group with increased arterial stiffness was independently related to BDBP in multiple logistic regression analysis. This study might be meaningful in evaluating the relationship between arterial stiffness and atherosclerotic risk factor in a new way, and be helped to make various studies for cardiovascular disease.

Impact of Hemodialysis on Left Ventricular Performance: A Doppler Echocardiographic Study (혈액투석 유지요법 환자에서 투석 전후의 좌심실 Doppler 심초음파를 이용한 기능지표의 변화)

  • Kang, Dong-Oh;Lee, Du-Ha;Kim, Hyun-Seo;Kim, Hyun-Su;Kim, Sung-Rok;Park, Jong-Seon
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.2
    • /
    • pp.309-317
    • /
    • 1999
  • Background: Left ventricular diastolic filling is an important determinant for maintenance of cardiac output during hemodialysis. Few investigators have studied the influence of hemodialysis on diastolic function. To evaluate the change of left ventricular systolic and diastolic function. we performed M-mode and Doppler echocardiographic studies before and after hemodialysis. Methods: The study population consisted of 30 patients(15 patients were male, mean age $45{\pm}10$ years) with CRF on maintenance hemodialysis. They have normal left ventricular systolic function(Fractional shortening>30%) and no evidence of valvular heart disease or regional wall motion abnormalities. The ejection fraction (EF) was measured using M-mode echocardiography and Doppler indices such as peak E velocity, peak A velocity, isovolumetric relaxation time(IVRT), deceleration time(DT). and left ventricular ejection time(LVET) obtained from Doppler echocardiography. The index of myocardial performance (IMP) was calculated from each of the Doppler velocity indices. Results: The weight reduction after hemodialysis was $2.1{\pm}1.0kg$(p<0.0001), After hemodialysis, there was some decrease in blood pressure(p<0.05), but no significant change in heart rate, EF and fractional shortening, mean VCF, peak A velocity, and DT. And significant reduction in peak E velocity, E/A ratio(p<0.0001. p<0.001), and significant increase in IVRT and IMP(p<0.05, p<0.0001) were noted. Conclusion: In conclusion, preload reduction is the main mechanism that accounts for changes in Doppler diastolic indices after hemodialysis. And an increased IMP suggests that diastolic function may be aggravated after hemodialysis, and that implies impaired left ventricular filling and disturbed left ventricular compliance.

  • PDF

Cardiac diastolic dysfunction predicts poor prognosis in patients with decompensated liver cirrhosis

  • Lee, Soon Kyu;Song, Myeong Jun;Kim, Seok Hwan;Ahn, Hyo Jun
    • Clinical and Molecular Hepatology
    • /
    • v.24 no.4
    • /
    • pp.409-416
    • /
    • 2018
  • Background/Aims: Left ventricular diastolic dysfunction (LVDD) is an early manifestation of cardiac dysfunction in patients with liver cirrhosis (LC). However, the effect of LVDD on survival has not been clarified, especially in decompensated LC. Methods: We prospectively enrolled 70 patients with decompensated LC, including ascites or variceal bleeding, at Daejeon St. Mary's Hospital from April 2013 to April 2015. The cardiac function of these patients was evaluated using 2D echocardiography with tissue Doppler imaging. The diagnosis of LVDD was based on the American Society of Echocardiography guidelines. The primary endpoint was overall survival. Results: Forty-four patients (62.9%) had LVDD. During follow-up (22.3 months), 18 patients died (16 with LVDD and 2 without LVDD). The survival rate was significantly lower in patients with LVDD than in those without LVDD (31.1 months vs. 42.6 months, P=0.01). In a multivariate analysis, the Child-Pugh score and LVDD were independent predictors of survival. Moreover, patients with a ratio of early filling velocity to early diastolic mitral annular velocity (E/e') ${\geq}10$ (LVDD grade 2) had lower survival than patients with E/e' ratio < 10. Conclusions: The presence of LVDD is associated with poor survival in patients with decompensated LC. Therefore, it may be important to monitor and closely follow LVDD patients.

Automatic Control System on Cardiac Output Regulation for the Moving Actuator Type Total Artificial Heart (MOVING-ACTUATOR TYPE 인공심장의 심박출 조절에 대한 자동 제어방법)

  • 김원곤
    • Journal of Chest Surgery
    • /
    • v.28 no.6
    • /
    • pp.542-548
    • /
    • 1995
  • The goal of this study is to develop an effective control system for cardiac output regulation based upon the preload and afterload conditions without any transducers and compliance chambers in the moving actuator type total artificial heart. Motor current waveforms during the actuator movement are used as an input to the automatic control algorithm. While the current waveform analysis is performed, the stroke length and velocity of the actuator are gradually increased up to the maximum pump output level. If the diastolic filling rate of either right or left pump begins to exceed the venous return, atrial collapse will occur. Since the diastolic suction acts as a load to the motor, this critical condition can be detected by analyzing the motor current waveforms. Every time this detection criterion is met, the control algorithm decreases the stroke velocity and length of the actuator step by step just below the critical detection level. Then, they start to increase. In this way the maximum pump output under given venous return can be achieved. Additionally the control algorithm provides some degree of afterload sensitivity. If the aortic pressure is detected to exceed 120 mmHg, the stroke length and velocity decrease in the same way as the response to the preload. Left-right pump output balance is maintained by proper adjustment of the asymmetry of the stroke angle. In the mock circulatory test, this control system worked well and there was a considerable range of stroke volume difference with adjustment of the asymmetry value. Two ovine experiments were performed. It was confirmed that the required cardiac output regulation according to the venous return could be achieved with adequate detection of diastolic function, at least in the in vivo short-term survival cases[2-3 days . We conclude that this control algorithm is a promising method to regulate cardiac output in the moving actuator type total artificial heart.

  • PDF

Association of the Strength of Inyoung Pulse and Carotid Artery Using Ultrasonography and Pulse Diagnosis Device (초음파와 맥진기로 살펴본 인영맥의 세기와 경동맥의 상관 요인 연구)

  • Song, Min Sun;Lee, Shang Young;Choi, Chan-Hun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.26 no.5
    • /
    • pp.610-614
    • /
    • 2012
  • This study was done to identify correlates of carotid artery ultrasonography's measurement and Inyoung pulse in college students. We measured the amplitude of Inyoung pulse, Chongu pulse, ratio of Inyoung to Chongu and ratio of Chongu to Inyoung on 30 college students. Also, We measured the Distance, Diameter), RI(resistivity index), S/D(systolic, diastolic ratio), PI(pulsatility index), PSV(peak systolic velocity), EDV(End diastolic velocity), Vmean using carotid artery ultrasonography. The data was analyzed by Pearson's correlation coefficient using SAS program. The results were as follow. Results showed a positive correlation between Inyoung pulse and diameter by carotid artery. It showed a positive correlation between Inyoung pulse and S/D. Also, It showed a positive correlation between Inyoung pulse and PSV. As a result, the strength of Inyoung pulse related with the diameter of carotid artery and blood flow velocity.