• Title/Summary/Keyword: Diaphragm

Search Result 1,189, Processing Time 0.024 seconds

Air-pressure Control of Diaphragm using Variable Frequency Current Control (가변 주파수 전류 제어에 의한 다이어프램의 압력제어)

  • Lim, Geun-Min;Lee, Dong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.258-265
    • /
    • 2011
  • This paper presents a variable frequency current control scheme for the air-pressure control of diaphragm. Differ from the conventional air-pressure control of diaphragm, the proposed method uses a single-phase inverter to control the phase current and frequency. The phase current is adjusted to keep the reference air-pressure of the diaphragm. And the current frequency is changed to reduce the mechanical vibration. In order to smooth change of the operation with a constant air-pressure, the frequency is changed according to the voltage reference from the current controller. When the phase current is satisfied to the constant air-pressure, the current frequency is increased to reduce the vibration of the diaphragm. When the reference voltage to keep the phase current is over than the set value, the current frequency is decreased to keep the air-pressure. The proposed control scheme is verified by the experimental test of a commercial diaphragm.

Comparison of Pulmonary Function, Respiratory Muscle Strength, and Diaphragm Thickness between Underweight and Normal Adults

  • Ho-Jeong Shin;Ho-Hee Son
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.18 no.3
    • /
    • pp.31-37
    • /
    • 2023
  • PURPOSE: This study aimed to investigate the relationship between being underweight and respiratory function indicators such as pulmonary function, respiratory muscle strength, and diaphragm thickness in normal adults without lung disease. METHODS: The participants in this experiment were thirty young adults. To compare the respiratory function between the underweight and normal weight individuals, 15 participants were selected from each of the underweight and normal weight groups based on body mass index. Respiratory function tests were conducted through pulmonary function tests and respiratory muscle strength tests. Diaphragm thickness was measure with ultrasonography, and physical characteristics were obtained from grip strength and waist circumference. An independent t-test was used to compare the averages of the parameters measured in the two groups. RESULTS: In the respiratory function tests between the two groups, statistically significant differences (p < .05) emerged in the ratio of the predicted forced vital capacity (%FVC), the ratio of the predicted forced expiratory volume in one second (%FEV1), maximal expiratory pressure (MEP), and diaphragm thickness at the functional residual capacity (FRC). There was no statistically significant difference in the forced vital capacity, forced expiratory volume in one second, maximal inspiratory pressure, diaphragm thickness at the total lung capacity, and thickening ratio (p > .05). CONCLUSION: Decreases in some variables of respiratory function, such as the %FVC, %FEV1, MEP, and diaphragm thickness at the FRC were observed in underweight subjects. However, it is difficult to determine whether it affected the overall respiratory function. Future studies are needed to clearly identify the relationship between being underweight and respiratory function.

Immediate Effects of Bilateral Pattern with Spiral pattern of PNF on Diaphragm Excursion and Vital Capacity in Normal Adults (정상 성인의 가로막 이동거리 및 폐활량에 대한 고유수용성신경근촉진법 Bilateral pattern with Spiral pattern의 즉각적 효과)

  • Kyoung-Seon Shin;Yu-Gyeong Lee;Eun-Bi Jeong;Dong-Yeop Lee;Ji-Heon Hong;Jae-Ho Yu;Seong-Gil Kim;Jin-Seop Kim
    • PNF and Movement
    • /
    • v.21 no.2
    • /
    • pp.151-158
    • /
    • 2023
  • Purpose: This study aimed to examine the immediate effects of different breathing training techniques on diaphragm excursion and vital capacity in healthy adults. Specifically, the study focused on comparing respiratory exercise without PNF, bilateral pattern respiratory exercise, and bilateral pattern with spiral pattern respiratory exercise. Methods: Twenty-seven healthy adults in their 20s participated in the study. Diaphragm excursion and vital capacity were evaluated under three different conditions. A one-way repeated ANOVA was used to analyze the differences in diaphragm excursion and vital capacity among the interventions. Results: Statistically significant differences were observed in diaphragm excursion among the interventions, comparing respiratory exercise without PNF, bilateral pattern respiratory exercise, and bilateral pattern with spiral pattern respiratory exercise. Similarly, statistically significant differences were found in vital capacity among the interventions without PNF respiratory exercise, bilateral pattern respiratory exercise, and bilateral pattern with spiral pattern respiratory exercise. Conclusion: The study demonstrated that incorporating the spiral technique in respiratory exercise led to increased diaphragm excursion and lung capacity compared to other interventions. These findings suggest that PNF respiratory exercise combined with the spiral pattern may have clinical implications for the treatment of respiratory diseases. Further research is warranted to explore the long-term effects and clinical application of these approaches.

A Numerical Analysis on the Diaphragm Structures for Improving Fatigue Performance in Orthotropic Steel Decks (강바닥판의 피로성능 향상을 위한 다이아프램 구조상세)

  • Shin, Jae Choul;An, Zu Og;Yoon, Tae Yang
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.6
    • /
    • pp.559-573
    • /
    • 2007
  • Orthotropic steel decks are manufactured by welding thin plates therefore it is inevitable that there are abundant works of welding process. On connection of transverse rib web, crossing point of longitudinal rib, transverse rib and deck plate and cut-out parts of transverse rib are the significant position of stress concentration because of out of plane and oil-canning deformation caused by longitudinal rib distortion with shear force and distortion. At the current research, the crossing point where the orthotropic steel decks's effect of improving fatigue performance are high, not placing scallop and diaphragm which have same plane with transverse rib placed inside of longitudinal rib at the same time, the reduce effects of stress concentration at the cut-out section and the crossing are high. Especially the installation of the diaphragm causing great effects based on research results to stress concentration appearance reduce effects at the cut-out section, putting radius of curvature of the diaphragm's top and bottom as a target, as a result of carrying out the parametric analysis an optimal diaphragm form that has great effects in fatigue performance came to a conclusion. Also based on optimal diaphragm form, an advantage of the diaphragm optimal setting position for improvement of the fatigue performance came to a conclusion.

Characteristics of Strong Alkaline Electrolyzed Water Produced in All-in-one Electrolytic Cell (일체형 전해조에서 생산된 강알카리성 전해수의 특성)

  • Lee, Ho Il;Rhee, Young Woo;Kang, Kyung Seok
    • Clean Technology
    • /
    • v.18 no.4
    • /
    • pp.446-450
    • /
    • 2012
  • Strong alkaline electrolyzed water which is produced in cathode by electrolyzing the solution where electrolytes (NaCl, $K_2CO_3$ etc.) are added in diaphragm electrolytic cell, is eco-friendly and has cleaning effects. So, it is viewed as a substitution of chemical cleaner. In addition, strong alkaline electrolyzed water is being used by some Japanese automobile and precision parts manufacturing industries. When strong alkaline electrolyzed water is produced by using diaphragm electrolytic cell, it is necessarily produced at the anode side. Since strong acidic electrolyzed water produced is discarded when its utilization cannot be found, production efficiency of electrolyzed water is consequently decreased. Also, there is a weakness electrolytic efficiency is decreasing due to the pollution of diaphragm. In order to overcome this, non-diaphragm all-in-one electrolytic cell integrated with electrode reaction chamber and dilution chamber was applied. Strong alkaline electrolyzed water was produced for different composition of electrolytes, and their properties and characteristics were identified. In comparing the properties between strong alkaline electrolyzed water produced in diaphragm electrolytic cell and that produced in all-in-one electrolytic cell, the differences in ORP and chlorine concentration were found. In emulsification test to confirm surface-active capability, similar results were obtained and strong alkaline electrolyzed water produced in non-diaphragm all-in-one electrolytic cell was identified to be useable as a cleaner like strong alkaline electrolyzed water produced in diaphragm electrolytic cell. Strong alkaline electrolyzed water produced in non-diaphragm all-in-one electrolytic cell is thought to have sterilizing power because it has active chlorine which is different from strong alkaline electrolyzed water produced in diaphragm electrolytic cell.

Study on Electro-Mechanical Characteristics of Array Type Capacitive Pressure Sensors with Stainless Steel Diaphragm and Substrate (스테인리스 강 박막 및 기판을 이용한 배열형 정전용량 압력센서의 전기 기계적 특성연구)

  • Lee, Heung-Shik;Chang, Sung-Pil;Cho, Chong-Du
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.11 s.254
    • /
    • pp.1369-1375
    • /
    • 2006
  • In this work, mechanical characteristics of stainless steel diaphragm have been studied as a potential robust substrate and a diaphragm material for micromachined devices. Lamination process techniques combined with traditional micromachining processes have been adopted as suitable fabrication technologies. To illustrate these principles, capacitive pressure sensors based on a stainless steel diaphragm have been designed, fabricated and characterized. The fabrication process for stainless steel micromachined devices keeps the membrane and substrate being at the environment of 8.65MPa pressure and $175^{\circ}C$ for a half hour and then subsequently cooled to $25^{\circ}C$. Each sensor uses a stainless steel substrate, a laminated stainless steel film as a suspended movable plate and a fixed, surface micromachined back electrode of electroplated nickel. The finite element method is adopted to investigate residual stresses formed in the process. Besides, out-of-plane deflections are calculated under pressures on the diaphragm. The sensitivity of the device fabricated using these technologies is 9.03 ppm $kPa^{-1}$ with a net capacitance change of 0.14 pF over a range 0$\sim$180 kPa.

Optical Microphone Based on a Reflective Micromirror Diaphragm (반사형 마이크로 미러를 이용한 광마이크로폰)

  • Song, Ju-Han;Lee, Sang-Shin
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.4
    • /
    • pp.366-370
    • /
    • 2006
  • An optical microphone incorporating a reflective diaphragm and a fiber-optic head was demonstrated. The diaphragm was made of a micromirror membrane which is suspended by a silicon bar connected to a frame, allowing fer a displacement induced by acoustic waves. A compact, simple optical head was implemented by exploiting a single multimode fiber. For the assembled microphone, the static characteristics were investigated to find the operation point defined as the optimum distance between the head and the diaphragm, and a flat frequency response with a variation of $\sim$2dB for the range of up to 2 kHz was accomplished.

Case Study of Self-Supported Diaphragm Wall Method Using Counterfort Technique (부벽식 기법을 사용한 자립식 지하연속벽 공법의 사례 연구)

  • Jeong, Gyeong-Hwan;Park, Hun-Kook;Shin, Min-Sik;Han, Kyoung-Tae;Ryu, Ji-Young
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.276-285
    • /
    • 2006
  • Application of anchored or strutted wall system for the earth retention of excavation works in a populated urban area or a poor soil deposit can be limited due to various restrictions. Since the strut becomes longer in a wide excavation site, the stability of an earth retaining wall is decreased, the wall deformation is increased, and the ground settlement is also increased due to an increased buckling or bending deformation of struts. Especially, in a populated urban area, the installation of anchors can be problematic due to the property line of adjacent structures or facilities. Thus, a new concept of earth retaining system like Self-Supported diaphragm Wall can solve several problems expected to occur during excavation in the urban area. In this study, Numerical analyses of counterfort diaphragm wall was introduced and the monitored data from the site was compared with the original results of numerical analyses. Also, in the case of the deep excavation applied the counterfort diaphragm wall, numerical analyses was performed to predict the wall deformation and the reinforcement to reduce the wall deformation was suggested.

  • PDF

Design and Fabrication of Silicon Flow Sensor For Detecting Air Flow (유속 감지를 위한 실리콘 유량센서의 설계 및 제작)

  • 이영주;전국진;부종욱;김성태
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.5
    • /
    • pp.113-120
    • /
    • 1994
  • Silicon flow sensor that can detect the velocity and direction of air flow was designed and fabricated by integrated circuit process and bulk micromachining technique. The flow sensor consists of three-layered dielectric diaphragm, a heater at the center of the diaphragm, and four thermopiles surrounding the heater at each side of diaphragm as sensing elements. This diaphragm structure contributes to improve the sensitivity of the sensor due to excellent thermal isolation property of dielectric materials and their tiny thickness. The flow sensor has good axial symmetry to sense 2-D air flow with the optimized sensing position in the proposed structure. The sensor is fabricated using CMOS compatible process followed by the anisotropic etching of silicon in KOH and EDP solutions to form I$\mu$ m thick dielectric diaphragm as the last step. TCR(Temperature Coefficient of Resistance) of the heater of the fabricated sensors was measured to calculate the operating temperature of the heater and the output voltage of the sensor with respect to flow velocity was also measured. The TCR of the polysilicon heater resistor is 697ppm/K, and the operating temperature of the heater is 331$^{\circ}C$ when the applied voltage is 5V. Measured sensitivity of the sensor is 18.7mV/(m/s)$^{1/2}$ for the flow velocity of smaller than 10m/s.

  • PDF

Study on Structural Performance of Two Seam Cold-Formed Square CFT Column to Beam Connections with Internal Diaphragm (2-Seam 냉간성형 각형 CFT 기둥-보 내다이아프램 접합부의 구조성능에 관한 연구)

  • Oh, Heon-Keun;Kim, Sun-Hee;Choi, Young-Hwan;Choi, Sung-Mo
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.3 no.4
    • /
    • pp.27-37
    • /
    • 2012
  • The construction of a moment connection for a rectangular hollow section (RHS) column and a H-shaped beam is difficult because the RHS is a closed section. When a inner diaphragm is used for such a connection, in general, it is installed after cutting the HSS columns, which results in increased construction work. This paper suggests a new fabrication method to overcome such problems: An inner diaphragm is welded to inside a C-shaped section first, and then a column is fabricated by welding two C-shaped sections. This fabrication method is superior to a classic method in terms of constructibility. An experimental and a numerical study using Ansys 9.0 were performed in order to compare the strength of connections with respect to the presence of concrete, the corner shape of diaphragm, and the axis of loading. The experimental results including initial stiffness and ultimate loads are reported and the analytical results including load transfer mechanism, degree of stress concentration, and strain distribution are also reported.