• 제목/요약/키워드: Diaphragm

검색결과 1,169건 처리시간 0.026초

스트럿-타이 모델에 의한 프리스트레스트 콘크리트 박스교 격벽부의 상세 설계 (Design of Diaphragm of Prestressed Concrete Box Bridge by Strut-Tie Model)

  • 선민호;김영훈;송하원;변근주
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 추계학술대회 논문집
    • /
    • pp.39-46
    • /
    • 1998
  • This paper is about design for diaphragm of prestressed concrete box bridge using strut-tie model. In this paper, equivalent loads for the diaphragm are computed by considering loading conditions on continuous prestressed concrete box bridge and analyses for both longitudinal section and transverse section of the diaphragm an done by considering the equivalent loading and the prestressing. Based on principal stress trajectory obtained from the analyses, strut-tie model for each sections are constructed. By analyzing the constructed strut-tie model for each sections, the amounts and the locations of reinforcement for the diaphragm are obtained. The application of strut-tie model in this paper shows that the design by soul-tie model for the diaphragm of prestressed concrete box bridges can be rationally performed.

  • PDF

Verification of diaphragm seismic design factors for precast concrete parking structures

  • Zhang, Dichuan;Fleischman, Robert
    • Structural Engineering and Mechanics
    • /
    • 제71권6호
    • /
    • pp.643-656
    • /
    • 2019
  • A new seismic design methodology was proposed for precast concrete diaphragms. This methodology adopts seismic design factors applied on top of current diaphragm design forces. These factors are aimed to produce diaphragm design strengths aligned with different seismic performance targets. These factors were established through extensive parametric studies. These studies used a simple evaluation structure with a single-bay rectangular diaphragm. The simple evaluation structure is suitable for establishment of the design factors over comprehensive structural geometry and design parameters. However, the application of the design factors to prototype structures with realistic layouts requires further verification and investigation. This paper presents diaphragm design of several precast concrete parking structures using the new design methodology and verification of the design factor through nonlinear dynamic time history analyses. The seismic behavior and performance of the diaphragm were investigated for the precast concrete parking structures. It was found that the design factor established for the new design methodology is applicable to the realistic precast concrete parking structures.

The Successful Removal of a Foreign Body in the Spleen via Diaphragm Laceration Site by Video-Assisted Thoracoscopic Surgery

  • Jeon, Yang Bin;Hyun, Sung Youl;Ma, Dae Sung
    • Journal of Trauma and Injury
    • /
    • 제32권2호
    • /
    • pp.122-125
    • /
    • 2019
  • A 73-year-old man, who, in an inebriated state, had slipped in a flowerbed and was wounded on the left flank, was transferred to Trauma Center, Gil Medical Center, Gachon University College of Medicine. Based on the chest and abdominopelvic computed tomography, he was diagnosed with multiple rib fractures and hemopneumothorax on the left hemithorax and was found to have a bony fragment in the spleen. He had not presented peritonitis and exsanguinous symptoms during the observation period. Seven days later, computed tomography of the abdomen showed suspected diaphragmatic injury and a retained foreign body in the spleen. On exploration by video assisted thoracoc surgery (VATS), a herniated omentum through the lacerated site of the diaphragm was observed. After omentectomy using Endo Gia, the foreign body in the spleen was observed through the lacerated site of the diaphragm. Traumatic diaphragm rupture with a foreign body, in the spleen, was successfully managed by video assisted thoracic surgery via the lacerated site of the diaphragm.

열공압형 마이크로펌프의 액추에이터 박막 거동 특성에 관한 실험적 연구 (Experimental Study of the Behavior Characteristics of Actuator Diaphragms in Thermopneumatic Micropumps)

  • 이종문;김영득;김우승
    • 대한기계학회논문집B
    • /
    • 제34권6호
    • /
    • pp.599-606
    • /
    • 2010
  • 본 연구에서는 다양한 작동조건(인가전압, 주파수)에 대하여 박막의 두께와 챔버의 직경이 열공압형 마이크로펌프의 액추에이터 박막의 거동 특성에 미치는 영향을 실험적으로 파악하기 위해 다양한 박막 두께와 챔버직경의 액추에이터를 제작하였다. 액추에이터는 파이렉스 표면에 위치한 마이크로히터, 챔버, 그리고 박막으로 구성된다. 모든 인가전압에 대하여 주파수가 10 Hz 이하로 감소함에 따라 박막 중앙의 최대 변위는 박막의 두께와 챔버의 직경에 관계없이 크게 증가한다. 낮은 주파수 영역에서 챔버로 공급되는 열량이 증가함에 따라 박막 중앙의 변위는 박막의 두께가 얇을수록, 챔버의 직경이 작을수록 증가한다. 10 Hz 이상의 주파수 영역에서 박막 두께, 챔버 직경, 공급 열량과 같은 모든 설계 변수가 박막 중앙의 변위에 미치는 영향은 미미하다.

Behavior of improved through-diaphragm connection to square tubular column under tensile loading

  • Qin, Ying;Zhang, Jing-Chen;Shi, Peng;Chen, Yi-Fu;Xu, Yao-Han;Shi, Zuo-Zheng
    • Structural Engineering and Mechanics
    • /
    • 제68권4호
    • /
    • pp.475-483
    • /
    • 2018
  • Square tubular columns are commonly used in moment resisting frames, while through-diaphragm connection is the most typical configuration detail to connect the H-shaped beam to the column. However, brittle fracture normally occurs at the complete joint penetration weld between the beam flange and the through-diaphragm due to the stress concentration caused by the geometrical discontinuity. Accordingly, three improved types of through-diaphragm are presented in this paper to provide smooth force flow path comparing to that of conventional connections. Tensile tests were conducted on four specimens and the results were analyzed in terms of failure modes, load-displacement response, yield and ultimate capacity, and initial stiffness. Furthermore, strain distributions on the through-diaphragm, the beam flange plate, and the column face were comprehensively evaluated and discussed. It was found that all the proposed three types of improved through-diaphragm connections were able to reduce the stress concentration in the welds between the beam flange and the through-diaphragm. Furthermore, the stress distribution in connection with longer tapered through-diaphragm was more uniform.

다이아프램식 수소압축기에서 다이아프램 변형특성에 관한 실험적 연구 (An Experimental Study on the Diaphragm Deflection Characteristic of a Hydrogen Diaphragm Compressor)

  • 신영일;박현우;이영준;김규보;송주헌;장영준;전충환
    • 한국수소및신에너지학회논문집
    • /
    • 제20권4호
    • /
    • pp.274-282
    • /
    • 2009
  • Diaphragm compressor is widely used for hydrogen compression because it achieves high gas pressure without gas contamination. Diaphragm deflecting in the cavity with high pressure formed by an oil compression is the most important component in the compressor. Therefore, it is necessary to obtain deflection degree of diaphragm to predict the damage point of diaphragm. The objective of this study is to estimate the diaphragm's damage point through diaphragm deflection test by implementing with strain gauges attached on several radial points. Without gas compression, strain sum of each points varied as similarly as the variation of the pressure with respect to time. And while the motor speed was slower than 400rpm, the strain near the rim was larger than that of the center. When motor speed, however, was over 500rpm, strain became similar to that of the center and the rim. With gas compression, it was shown that the variation of the strain sum was delayed against that of the pressure and the strain near the rim was much higher than that of the center.

고무 다이아프램의 변형거동 전산해석 (Computer Simulation of Deformation Behavior of the Rubber Diaphragm)

  • 조성도성;김완두
    • Elastomers and Composites
    • /
    • 제35권1호
    • /
    • pp.4-11
    • /
    • 2000
  • 어큐뮬레이터에 사용되는 얇은 막 형태의 고무다이아프램은 외부의 맥동 및 충격압력을 흡수하고 유체의 수송과 압력을 전달하는 역할을 수행하며, 압력 변화에 따른 변형 거동은 어큐뮬레이터의 특성을 결정하는 중요한 설계 변수이다. 고무다이아프램은 고무 자체의 비선형성에 의한 비선형거동과 작은 압력 변화에도 큰 변형을 일으키는 대변형 거동을 나타내며, 임의 압력 이상에서는 고무다이아프램이 변형된 후 용기에 접촉되는 현상이 나타난다. 본 연구에서는 비선형 대변형 해석과 접촉 해석 둥이 용이한 구조해석 소프트웨어인 MARC를 이용하여 두 가지 형상에 대한 고무다이아프램의 거동을 해석하여, 고무 물성 변화와 압력 변화에 따른 변형 거동을 예측하고 파손 취약 부위로 예상되는 다이아프램의 고정 부위에서의 응력을 완화하기 위한 설계 개선 방안을 제시하였다.

  • PDF

횡경막성 내장탈출증: 1례 보고 (A Case of Eventration of the Diaphragm)

  • 박광훈;최인환
    • Journal of Chest Surgery
    • /
    • 제6권2호
    • /
    • pp.243-248
    • /
    • 1973
  • Eventration of the diaphragm is, by definition, abnormally high or elevated position of diaphragm as a result of paralysis, aplasia or atrophy of varing degrees of muscle fibers, and the cause of which may be congenital or acquired. The unbroken continuity of the diaphragm differentiates it from diaphragmatic hernia. The clinical manifestations of the condition, if present, are usually due to the interference of the ventilatory function of the lung and digesive dysfunction due to gastrointestinal distorsion. Treatment consists of surgical repair of the relaxed diaphragm to it`s normal position. A ease of left sided eventuration of the diaphragm, 31 year old officer, was found by chance after traffic accident with chief complaints of hemoptysis and multiple superficial contusions. Routine chest roentgenogram and barium study of the colon revealed moderately elevated left hemidiaphragm with displacement of the splenic flexure of the colon into the left chest. Past history revealed frequent attack of upper respiratory infection and some abnormal condition on his left chest announced by screen cheek of chest X-ray at the time of entrance for his army service 3 years before. Plication of the relaxed diaphragm through left thoracotomy was done and result was excellent as seen on Fig. 5. Cause of eventration of the left hemidiaphragm was due to paralysis of the left phrenic nerve which was tested during thoracotomy.

  • PDF

Variable-focus Liquid Lens Based on a Laterally-integrated Thermopneumatic Actuator

  • Lee, June Kyoo;Park, Kyung-Woo;Lim, Geunbae;Kim, Hak-Rin;Kong, Seong Ho
    • Journal of the Optical Society of Korea
    • /
    • 제16권1호
    • /
    • pp.22-28
    • /
    • 2012
  • We report a focal-length tunable liquid lens based on thermopneumatically driven fluidic pressure. The fluidic pressure is generated by deformation of an elastomeric diaphragm induced by thermopneumaticity from a laterally integrated microheater sealed within an air chamber. The pressure is transmitted by a confined liquid to a lens diaphragm through an internal fluid channel. The liquid filling under the lens diaphragm functions as a liquid lens for dynamic focusing with properties depending on the curvature of the deformed diaphragm. The diaphragm area of the air chamber is designed five times larger than that of the lens cavity to yield high focal-length tunability by amplified deflection of the lens diaphragm. With our method, we achieved excellent focal-length tunability from infinity (without an input current) to 4 mm (with an input current of 12 mA) with a lens aperture diameter of 2 mm.

Analysis of Design Parameters For Shunt Valve and Anti-Siphon Device Used to Treat Patients with Hydrocephalus

  • Lee, Chong-Sun;Jang, Jong-Yun;Suh, Chang-Min
    • Journal of Mechanical Science and Technology
    • /
    • 제15권7호
    • /
    • pp.1061-1071
    • /
    • 2001
  • The present study investigated design parameters of shunt valves and anti-siphon device used to treat patients with hydrocephalus. The shunt valve controls drainage of cerebrospinal fluid (CSF) through passive deflection of a thin and small diaphragm. The anti-siphon device(ASD) is optionally connected to the valve to prevent overdrainage when the patients are in the standing position. The major design parameters influencing pressure-flow characteristics of the shunt valve were analyzed using ANSYS structural program. Experiments were performed on the commercially available valves and showed good agreements with the computer simulation. The results of the study indicated that predeflection of the shunt valve diaphragm is an important design parameter to determine the opening pressure of the valve. The predeflection was found to depend on the diaphragm tip height and could be adjusted by the diaphragm thickness and its elastic modulus. The major design parameters of the ASD were found to be the clearance (gap height) between the thin diaphragm and the flow orifice. Besides the gap height, the opening pressure of the ASD could be adjusted by the diaphragm thickness, its elastic modulus, area ratio of the diaphragm to the flow orifice. Based on the numerical simulation which considered the increased subcutaneous pressure introduced by the tissue capsule pressure on the implanted shunt valve system, optimum design parameters were proposed for the ASD.

  • PDF