• Title/Summary/Keyword: Diamond Like Carbon(DLC)

Search Result 318, Processing Time 0.025 seconds

Multidirectional Liquid Crystal Orientation by Using Ion Beam Irradiation

  • Ahn, Han-Jin;Kim, Kyung-Chan;Kim, Jong-Bok;Hwang, Byung-Har;Baik, Hong-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.543-546
    • /
    • 2005
  • We have investigated the alignment ability of multi-domains by using ion beam irradiation on diamond-like carbon (DLC) thin film layers. The DLC thin films were deposited by plasma enhanced chemical vapor deposition (PECVD) system and the low energy ion beam is irradiated from Kaufman type ion gun. The direction of liquid crystal alignment is varied by the direction of Ar ion beam irradiation.

  • PDF

Properties of Boron Carbide Thin Films Deposited by Partially Reactive Magnetron Sputtering

  • Lee, K. E.;Kim, C. O.;Kim, J. H.;Lee, J. Y.;Park, M. J.;Lee, C. B.
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2002.12a
    • /
    • pp.124-125
    • /
    • 2002
  • 최근 자성막의 놀은 자기기록 밀도증가에 따른 고밀도 자성기록매체인 하드디스크(HDD)는 현재 80GByte까지의 저장용량을 가진 하드디스크의 자성합금층 보호막으로 DLC(Diamond-Like Carbon)가 이용되고 있다. 고저장용량을 가지는 하드디스크의 보호막 두께가 점차 얇아짐에 따라 보호막 재료의 경도 및 윤활성은 더욱 중요시되고 있다. 그러나, 보호막의 두께가 감소하면서 현재 적용되고 있는 DLC막으로는 조만간 물리적 한계에 도달할 것으로 예상된다. (중략)

  • PDF

이온소스법에 의한 DLC막의 제작 및 기계적 특성

  • Kim, Mi-Seon;Hong, Seong-Pil;Kim, Hyeon-Gu
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.164-165
    • /
    • 2007
  • Si(중간층)/DLC(diamond-like carbon)막은 스퍼터와 이온소스(ion source)법에 의한 복합방식(hybrid method)을 이용하여 3mTorr의 반응가스 벤젠($C_6H_6$)분위기에서 Si wafer에 기판온도 $130^{\circ}C$로 180분간 증착하였다. 평가는 표면과 단면에 대해 주사전자현미경(scanning electron microscopy, SEM)과 투자전자현미경(trasmission electron microsope, TEM)으로 관찰하였다. 경도와 마찰계수는 나노인텐터(nanoindetor)와 마모시험기를 이용하였으며, 박막의 구조는 라만스펙트럼으로 분석하였다. 그 결과 박막의 두께는 약 $0.9{\mu}m$, 표면조도는 약 $0.34{\sim}1.64nm$로 평탄한 표면을 가지며 경도는 약 $35{\sim}37GPa$, 마찰계수는 약 $0.02{\sim}0.07$로 관찰되었다. 라만분광법과 전자회절패턴에 의해 IG/ID의 함량비는 $0.54{\sim}0.59$$sp^2$$sp^3$가 혼재된 전형적인 비정질 구조임을 확인하였다.

  • PDF

Effect of Residual Stress on Raman Spectra in Tetrahedral Amorphous Carbon(ta-C) Film

  • Shin, Jin-Koog;Lee, Churl-Seung;Moon, Myoung-Woon;Oh, Kyu-Hwan;Lee, Kwang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.135-135
    • /
    • 1999
  • It is well known that Raman spectroscopy is powerful tool in analysis of sp3/sp3 bonding fraction in diamond-like carbon(DLC) films. Raman spectra of DLC film is composed of D-peak centered at 1350cm-1 and G-peak centered at 1530cm-1. The sp3/sp3 fraction is qualitatively acquired by deconvolution method. However, in case of DLC film, it is generally observed that G-peak position shifts toward low wavenumber as th sp3 fraction increases. However, opposite results were frequently observed in ta-C films. ta-C film has much higher residual compressive stress due to its high sp3 fraction compared to the DLC films deposited by CVD method. Effect of residual stress on G-peak position is most recommendable parameter in Raman analysis of ta-C, due to its smallest fitting error among many parameters acquired by peak deconvolution of symmetric spectra. In current study, the effect of residual stress on Raman spectra was quantitatively evaluated by free-hang method. ta-C films of different residual stress were deposited on Si-wafer by modifying DC-bias voltage during deposition. The variation of the G-peak position along the etching depth were observed in the free-hangs of 20~30${\mu}{\textrm}{m}$ etching depth. Mathematical result based on Airy stress function, was compared with experimental results. The more reliable analysis excluding stress-induced shift was possible by elimination of the Raman shift due to residual compressiove stress.

  • PDF

PECVD 증착조건 변화에 따른 a-C;H 박막의 구조 변화

  • 조영옥;노옥환;윤원주;이정근;최영철;이영희;최용각;유수창
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.93-93
    • /
    • 2000
  • 수소화된 비정질 탄소(a-C:H)는 그 증착 조건에 따라서 여러 가지 다른 구조와 특성을 갖게 되며, 특히 DLC(diamond-like carbon) 및 CNT(Carbon nanotube)는 FED (field emission display) 개발 면에서 중요하게 연구되고 있다. 우리는 a-C:H 박막을 PECVD (plasma-enhanced chemical vapor deposition) 방법으로 증착하고 CH4 가스를 사용하였고 기판 온도는 상온-32$0^{\circ}C$ 사이에서 변화되었다. 기판은 Corning 1737 glass, quartz, Si, Ni 등을 사용하였다. 증착 압력과 R.F. power는 각각 0.1-1 Torr 와 12-60w 사이에서 변화되었다. ESR 측정은 X-band(주파수 약 9 GHz)에서 그리고 상온에서 행해졌다. 상온에서의 스핀밀도는 약한-표준피치(weak-pitch standard) 스펙트럼과 비교하여 얻을 수 있었다. 그리고 a-C:H 박막의 구조는 He-Ne laser(파장 632.8 nm)를 이용하는 micro-Raman spectroscopy로 분석하였다. 증착조건에 따른 스핀밀도의 변화 및 Raman 스펙트럼에서의 D-peak, G-peak의 위치 및 반치록, I(D)/I(G) 등을 조사하였다. 증착된 a-C:H 박막은 R.F.power가 증가할수록 대체로 스핀밀도가 증가하였으며, Raman 스펙트럼에서의 I(D)/I(G) 비율은 대체로 감소하였다. 증착된 박막들은 polymer-like Carbon으로 추정되었으며, 스핀밀도가 증가할수록 대체적으로 흑연 구조 영역이 증가됨을 알 수 있었다. 또한 glass나 Si 기판에 비해 Ni 기판위에서 polymer-like Carbon 구조는 향상되는 경향을 보였다.

  • PDF

Study of surface modification and contact angle by electrospun PVdF-HFP membrane with DLC coating (DLC 코팅에 의한 PVdF-HFP 막의 표면변화 및 접촉각 연구)

  • Lee, Tae Dong;Cho, Hyun;Yoon, Su Jong;Kim, Tae Gyu
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.24 no.1
    • /
    • pp.33-40
    • /
    • 2014
  • Poly vinylidene fluoride-co-hexafluoropropylene (PVdF-HFP) membrane were prepared by the electrospinning technique. We had applied a DLC coating process and then the surface of the membrane and the contact angle change was investigated. Electrospun fibrous PVdF-HFP membrane surface became to wrinkled shape by Ar plasma treatment and treatment conditions. The wrinkled surface of PVdF-HFP membrane became super-hydrophilic. However, after DLC coating process, it became super-hydrophobic. The resulting surfaces were characterized by water contact angle measurement, X-ray photoelectron spectroscopy (XPS) and field emission scanning electron microscopy (FE-SEM). Resultantly it was recognized that the wettability characteristics of the membrane surfaces depended on the chemical composition and surface morphology.

Multi-layer resist (MLR) structure with a very thin DLC layer

  • Kim, H.T.;Kwon, B.S.;Park, S.M.;Lee, N.E.;Cho, H.J.;Hong, B.Y.
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2007.04a
    • /
    • pp.71-72
    • /
    • 2007
  • In this study, we investigated the fabrication of MLR (multi-layer resist) with a very thin diamond-like carbon (DLC) layer. ArF PR/$SiO_2$/DLC MLR structure was investigated and etching characteristics of the DLC layer was patterned using $SiO_2$ hard-mask by varying the process parameters such as different high-frequency/low-frequency combination ($f_{LF}/f_{HF}$), HF/LF power ratio ($P_{HF}/P_{LF}$), $O_2$ flow and $N_2$ flow rate in $O_2/N_2$/Ar plasmas. The results indicated an increased etch rate of DLC for the higher $f_{LF}/f_{HF}$ combination and for the increased low-frequency power ($P_{LF}$). And the etch rate of DLC was decreased with increasing the $N_2$ flow rate in $O_2/N_2$/Ar plasmas. In order to confirm the application of DLC MLR for the etching process of silicon oxide, the stack of ArF PR/BARC/$SiO_2$/DLC/TEOS/Si was investigated.

  • PDF

Evaluation of Sliding Friction Properties of Laser Surface Texturing Dimple Pattern with DLC Coating under GaInSn Liquid Metal Lubricant (액체금속(GaInSn)윤활하에서 DLC(ta-C) 코팅된 레이저 표면 텍스쳐링 딤플패턴의 미끄럼 마찰특성평가)

  • Kwon, Gyubin;Jang, Youngjun;Chae, Younghun
    • Tribology and Lubricants
    • /
    • v.37 no.3
    • /
    • pp.106-111
    • /
    • 2021
  • There are several studies on reducing the friction that occurs on the relative sliding contact surface of moving parts under extreme environments. In particular, a solid lubricated bearing is studied to solve the tribological problem with friction reduction and durability parts using solid lubricants (lead or silver) in a vacuum atmosphere. Galinstan is mainly used as a liquid metal lubricant, but it is inevitable to have limited tribological applications owing to its high coefficient of friction. Many researchers work on surface texturing for surface modification and precision processing methods. To increase durability and low friction, DLC coating with hydrophobicity is applied on the contact surface texture. Therefore, using an untextured specimen, a dimple specimen, and a DLC-coated dimple specimen under liquid metal lubrication, this paper presents the following experimental sliding friction characteristics in the sliding friction test. 1) The average coefficient of friction of the DLC-coated dimple specimen and dimple specimen are lower compared to that of a non-patterned specimen. 2) In the DLC-coated dimple specimens, the average coefficient of friction changes according to the change in the dimple density. 3) DLC-coated dimple specimens with a density of 12.5 have the lowest average coefficient of friction under 41.6 N of normal load and 143.3 RPM.

Evaluation of Failure Modes and Adhesion of DLC Films by Scratch Test (스크래치 시험을 통한 DLC 박막 파손과 밀착 특성 평가)

  • Kim, Ju Hee;Park, Chanhyung;Ahn, Hyo Sok
    • Tribology and Lubricants
    • /
    • v.33 no.4
    • /
    • pp.127-133
    • /
    • 2017
  • In order to characterize the adhesive properties and failure mechanisms of diamond-like carbon (DLC) films of two different thicknesses (130 nm and $1.2{\mu}m$), deposited by plasma-enhanced chemical vapor deposition on a Si substrate, scratch testing with a micro-indenter ($12.5{\mu}m$ tip radius) was performed under a linearly increasing load. These scratch tests were conducted under the same test conditions for both films. The critical load of each film was estimated from the scratch test results, based on a sharp increase in the coefficient of friction and a clear distinction of failure modes. The critical load was the basis for evaluating the adhesion strength of the films, and the $1.2{\mu}m-thick$ DLC film had superior adhesion strength. For better understanding of the failure modes, the following analyses were conducted: friction behavior and scratch tracks analysis using scanning electron microscopy, energy-dispersive spectroscopy, and 3-D profilometry. The scratch test results showed that failure modes were related to the thickness of the films. The 130 nm-thick DLC film underwent cohesive failure modes (cracks and chipping) before reaching to a gross failure stage. On the other hand, the thicker DLC film ($1.2{\mu}m-thick$) did not exhibit micro cracks before a sudden gross failure of the film together with the evidence of cracking and chipping of the Si substrate.

Wear Property of SACM645 Material with DLC Coating (DLC 코팅된 SACM645 소재의 마모 특성)

  • Kim, Nam-Soek;Nam, Ki-Woo;Park, Jong-Nam;Ahn, Seok-Hwan;Kim, Hyun-Soo
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.6
    • /
    • pp.76-80
    • /
    • 2010
  • Oil hydraulic piston pumps are being extensively used around the world, because of their simple design, light weight, effective cost, etc. An oil hydraulic pump is likely to have the serious problems of high leakage, friction, and low energy efficiency after a long period of use. In an oil hydraulic piston pump, the clearance between the valve block and piston plays an important role for volumetric and overall efficiency. In this study, the wear property of the SACM645 material with DLC coating used for a hydraulic piston pump was determined by experimentation with variable heat treatment. To investigate the effect according to the piston surface condition, five different types of specimens were prepared. The maximum tensile strengths of the QT and QT Nitration specimens had similar values of about 800 MPa, but the strains indicated a big difference. In a wear test, the wear characteristic of the DLC coating specimen was shown to be excellent. The QT, QT + IH, QT + Nitration, and matirx specimen showed similar wear characteristics. In the case of a dry condition without oil, the DLC coating specimen had good wear resistance, with no wear shown.