• Title/Summary/Keyword: Diamond Band-saw

Search Result 3, Processing Time 0.024 seconds

Performance Evaluation of Dicing Sawing of High-densified Al2O3 Bulk using Diamond Electroplated Band-saw Machine (다이아몬드전착 밴드쏘우장비를 이용한 고치밀도 알루미나소결체의 다이싱가공 성능평가)

  • Lee, Yong-Moon;Park, Young-Chan;Kim, Dong-Hyun;Lee, Man-Young;Kang, Myung Chang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.6
    • /
    • pp.1-6
    • /
    • 2017
  • Recently, the brittle materials such as ceramics, glass, sapphire and textile material have been widely used in semiconductors, aerospace and automobile owing to high functional characteristics. On the other hand, it has the characteristics of difficult-to-cut material relative to all materials. In this study, diamond electro-deposited band-saw machine was developed to operate stably using water-coolant type through relative motion between band-saw tool and $Al_2O_3$ material. High densified $Al_2O_3$ material was manufactured by spark plasma sintering method. The bulk density was observed by the Archimedes law and the theoretical density was estimated to be $3.88g/cm^3$ and its hardness 14.7 MPa. From the dicing sawing test of $Al_2O_3$ specimen, behavior of surface roughness and band-saw wear are dominantly affected by the increase of the band-saw linear velocity. Additionally, an continuous pattern type of diamond band-saw was a very effective due to entry impact as a one-off for brittle material.

ZnO/3C-SiC/Si(100) 다층박막구조에서의 표면탄성파 전파특성

  • 김진용;정훈재;나훈주;김형준
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.80-80
    • /
    • 2000
  • Surface acoustic wave (SAW) devices have become more important as mobile telecommunication systems need h호-frrequency, low-loss, and down-sized components. Higher-frequency SAW divices can be more sasily realized by developing new h호-SAW-velocity materials. The ZnO/diamond/Si multilasyer structure is one of the most promising material components for GHz-band SAW filters because of its SAW velocity above 10,000 m/sec. Silicon carbide is also a potential candidate material for high frequency, high power and radiation resistive electronic devices due to its superior mechanical, thermal and electronic properties. However, high price of commercialized 6- or 4H-SiC single crystalline wafer is an obstacle to apply SiC to high frequency SAW devices. In this study, single crystalline 3C-SiC thin films were grown on Si (100) by MOCVD using bis-trimethylsilymethane (BTMSM, C7H20Si7) organosilicon precursor. The 3C-SiC film properties were investigated using SEM, TEM, and high resolution XRD. The FWHM of 3C-SiC (200) peak was obtained 0.37 degree. To investigate the SAW propagation characteristics of the 3C-SiC films, SAW filters were fabricated using interdigital transducer electrodes on the top of ZnO/3C-SiC/Si(100), which were used to excite surface acoustic waves. SAW velocities were calculated from the frequency-response measurements of SAW filters. A generalized SAW mode. The hard 3C-SiC thin films stiffened Si substrate so that the velocities of fundamental and the 1st mode increased up to 5,100 m/s and 9,140 m/s, respectively.

  • PDF

MICROLEAKAGE OF POSTERIOR PACKABLE COMPOSITE RESIN hi THE GINGIVAL MARGINS OF CLASS II CAVITIES (제 2급 와동에서 구치부 복합레진의 미세변연누출에 관한 연구)

  • Choi, Su-Jin;Kim, Mi-Ja;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.3
    • /
    • pp.249-256
    • /
    • 2002
  • The use of flowable composite resins as liners in class II packable composite restoration has been suggested by some manufacturers. However, the contributions of this technique are unproven. The purpose of this study was to compare the gingival microleakage in class II packable composite restorations with or without the use of flowable composite resins as liners. Slot cavities were prepared on both proximals of 80 extracted human molars and randomly assigned to 8 groups of 20 each. The gingival margins were located at 1mm above CEJ in 80 cavities (group1-4) and 1mm below CEJ in 80 cavities (group5-8). The prepared teeth were mounted in the customized tray with adjacent teeth to simulate clinical conditions and metallic matrix band (Sectional matrix) and wooden wedges were applied. After acid etching and application of Single Bond, each group was restored with the following materials using incremental placement technique: Group 1,5 (Filtek P60), group 2, 3, 4 and group 6, 7, 8 (AeliteFlo, TetricFlow, Revolution/ Filtek P60). All specimens were thermocycled 500 times between 5$^{\circ}C$ and 55$^{\circ}C$ with 1 mimute dwell time, immersed 2% methylene blue dye for 24 hours and then rinsed with tab water. The specimens were embedded in clear resin and sectioned longitudinally through the center of restoration with a low speed diamond saw. Dye penetration at gingival margin was viewed at 20 magnification and analyzed on a scale of 0 to 4. Kruscal-Wallis One way analysis and Mann-Whitney Rank sum test were used to analyze the results. The results of this study were as follows. 1. The leakage values seen at the enamel margin were significantly lower than those seen at the dentin margin(P<0.05). 2. On the enamel margin, packable composite resins with flowable liners showed lower leakage than those without flowable liners, but there were no significant differences among the four groups(P>0.05). 3. On the dentin margin, four groups demonstrated moderate to severe leakage, and there were no significant differences in leakage values(P>0.05).