• 제목/요약/키워드: Diameter distribution model

검색결과 317건 처리시간 0.027초

Simulation study on porosity disturbance of ultra-large-diameter jet borehole excavation based on water jet coal wetting and softening model

  • Guo, Yan L.;Liu, Hai B.;Chen, Jian;Guo, Li W.;Li, Hao M.
    • Geomechanics and Engineering
    • /
    • 제30권2호
    • /
    • pp.153-167
    • /
    • 2022
  • This study proposes a method to analyze the distribution of coal porosity disturbances after the excavation of ultra-large-diameter water jet boreholes using a coal wetting and softening model. The high-pressure jet is regarded as a short-term high-pressure water injection process. The water injection range is the coal softening range. The time when the reference point of the borehole wall is shocked by the high-pressure water column is equivalent to the time of high-pressure water injection of the coal wall. The influence of roadway excavation with support and borehole diameter on the ultra-large-diameter jet drilling excavation is also studied. The coal core around the borehole is used to measure the gas permeability for determining the porosity disturbance distribution of the coal in the sampling plane to verify the correctness of the simulation results. Results show that the excavation borehole is beneficial to the expansion of the roadway excavation disturbance, and the expansion distance of the roadway excavation disturbance has a quadratic relationship with the borehole diameter. Wetting and softening of the coal around the borehole wall will promote the uniform distribution of the overall porosity disturbance and reduce the amplitude of disturbance fluctuations.

다단계 반복기법을 이용한 관로시스템의 최적관경 결정 (determination of Optimum Pipe diameter Using Multi-Stage Iterative Method in Water Distribution system)

  • 한건연;박재홍
    • 한국수자원학회논문집
    • /
    • 제31권3호
    • /
    • pp.327-335
    • /
    • 1998
  • 상수관망은 상수공급시스템에서 핵심적인 부분이다. 주어진 상수공급시스템에서 배수관망에 대한 비용은 사업전체 비용에 대한 대부분을 차지하고 있다. 관망에 대한 설계과정 중에서 최적화기법을 사용하여 비용을 절감하기 위한 연구가 시도되었다. 주어진 상수관망 시스템의 설계시 고려되는 관경의 결정을 위해 유량해석과 최적화 기법이 연계되어 해석하는 반복기법이 적용되었다. 유량해석을 위해서 선형화기법이 되입되었고 관경의 최적화를 위해서 선형계획법에 기초한 개정 단체법을 이용하였다. 22개 관로와 35개 관로를 가진 실제관망에 본 모형을 적용한 결과 짧은 계산시간으로 최적화된 상용관을 결정할 수 있었다.

  • PDF

Droplet size prediction model based on the upper limit log-normal distribution function in venturi scrubber

  • Lee, Sang Won;No, Hee Cheon
    • Nuclear Engineering and Technology
    • /
    • 제51권5호
    • /
    • pp.1261-1271
    • /
    • 2019
  • Droplet size and distribution are important parameters determining venturi scrubber performance. In this paper, we proposed physical models for a maximum stable droplet size prediction and upper limit log-normal (ULLN) distribution parameters. For the proposed maximum stable droplet size prediction model, a Eulerian-Lagrangian framework and a Reitz-Diwakar breakup model are solved simultaneously using CFD calculations to reflect the effect of multistage breakup and droplet acceleration. Then, two ULLN distribution parameters are suggested through best fitting the previously published experimental data. Results show that the proposed approach provides better predictions of maximum stable droplet diameter and Sauter mean diameter compared to existing simple empirical correlations including Boll, Nukiyama and Tanasawa. For more practical purpose, we developed the simple, one dimensional (1-D) calculation of Sauter mean diameter.

혈류의 유동이 혈관-인조혈관 접속부 혈관 내막 세포증식에 미치는 영향 (Hemodynamic Effects on Artery-Graft Anastomotic Intimal Hyperplasia)

  • 이계한
    • 대한의용생체공학회:의공학회지
    • /
    • 제15권2호
    • /
    • pp.143-150
    • /
    • 1994
  • Wall shear rate or stress is believed to be a major hemodynamic variable influencing atherosclerosis and artery-graft anastomic intimal hyperplasia. The purpose of this study is to verify the effects of radial wall motion, artery-graft compliance and diameter mismatch, and impedance phase angle on the wall shear rate distribution near an end-to-end artery-graft anastomosis model. The results show that radial wall motion of the elastic artery model lowers the mean wall shear rates under pulsatile flow condition by 15 to 20 % comparing to those under steady flow condition at the same mean flow rate. Impedance phase angle seems to have small effects on the mean and amplitude of the wall shear rate distribution. In order to study the effects of compliance and diameter mismatch on the wall shear rates, two models are studied-Model I has 6% and Model I has 6% and Model II has 11% smaller graft diameter. Divergent geometry caused by diameter mismatch near the distal sites reduces the mean wall shear rates significantly, and this low shear region is believed to be prone to intimal hyperplasia.

  • PDF

축류형 사이클론을 이용한 공기역학경과 광학직경 상관관계 분석에 관한 연구 (A Study on Correlation Analysis between Aerodynamic Diameter and Optical Diameter Using Axial Flow Cyclone)

  • 김은정;박경려;허지은;조철희;조윤행
    • 한국입자에어로졸학회지
    • /
    • 제19권4호
    • /
    • pp.155-164
    • /
    • 2023
  • APS (Aerodynamic Particle Sizer) and OPC (Optical Particle Counter) have been widely used to real-time measurement of indoor and outdoor aerosols. The APS measures the size distribution based on an aerodynamic diameter, while the OPC uses optical diameter to measure the size distribution of aerosols. Since obtaining a size distribution based on aerodynamic diameter is important to understand aerosol characteristics, lots of researcher had been developed experimental equations which can convert optical diameter into aerodynamic diameter. However, previous studies have conducted repeated experiments on particles having a single diameter. In this study, an experimental method of converting optical diameter into aerodynamic diameter through a single experiment was presented. The collection efficiencies of an axial cyclone were measured using APS and OPC at the same time, and the correlation equation between aerodynamic diameter and optical diameter was driven through a theoretical model. Using the proposed method, the size distribution of NaCl particles measured by OPC showed a high correlation with the size distribution obtained by APS (0.93 of R-squared value). In the tests conducted on ISO A1, A2, and A4 test particles, the converted OPC size distribution tended to be similar to the APS size distribution, and for each of test particles (ISO A1, A2, and A4), the R-squared values for the APS particle size distribution were 0.75, 0.86, and 0.89, respectively.

유한요소법을 이용한 치과 임플란트 고정체의 직경과 길이에 따른 지지골의 응력 분석 (Finite element analysis on the stress of supporting bone by diameters and lengths of dental implant fixture)

  • 이명곤
    • 대한치과기공학회지
    • /
    • 제38권3호
    • /
    • pp.151-156
    • /
    • 2016
  • Purpose: The dental implant should be enough to endure chewing load and it's required to have efficient design and use of implant to disperse the stress into bones properly. This study was to evaluate the stress distribution on a supporting bone by lengths and diameters of the implant fixture. Methods: The modeling and analysis of stress distribution was used for the simple molar porcelain crown model by Solidworks as FEM program. It was designed on applying with tightening torque of 20 Ncm of a abutment screw between a cement retained crown abutment and a fixture. The fixtures of experimental model used 10, 13mm by length and 4, 5mm by diameter. A external vertical loading on the two buccal cusps of crown and performed finite element analysis by 100 N. Results: The maximum von Mises stress(VMS) of all supporting bone models by fixture length and diameter were concentrated on the upper side of supporting compact bone. The maximum stress of each model under vertical load were 164.9 MPa of M410 model, and 141.2 MPa of M413 model, 54.3 MPa of M510 model, 53.6 MPa of M513 model. Conclusion: The stress reduction was increase of fixture's diameter than it's length. So it's effective to use the wider fixture as possible to the conditions of supporting bone.

꿀샘식물 아까시나무의 지위지수 도출 및 직경분포 변화 (Development of Diameter Distribution Change and Site Index in a Stand of Robinia pseudoacacia, a Major Honey Plant)

  • 김소라;송정은;박천희;민수희;홍성희;윤준혁;손영모
    • 한국산림과학회지
    • /
    • 제111권2호
    • /
    • pp.311-318
    • /
    • 2022
  • 본 연구는 꿀샘식물인 아까시나무의 적지적수 조림을 위해 판정기준인 지위지수를 도출하고, 도출된 지위지수별 경급별 분포 변화를 알아보기 위하여 수행되었다. 아까시나무 임분의 지위지수를 추정하기 위하여 적용한 모델은 Chapman-Richards식이었다. 도출된 식에 따르면, 우리나라 아까시나무의 지위지수는 기준임령이 30년 일 때 16~22 범위 내에 분포하는 것으로 나타났다. 그리고 지위지수 추정 모델의 적합성은 약 37%정도로 낮았으나, 식의 잔차분포가 한쪽으로 치우지지 않아(bias -0.0030) 활용에는 문제가 없는 것으로 판단된다. 아까시나무 생장에 따른 지위별 직경분포를 구명하기 위해서는 Weibull 직경분포함수를 이용하였다. 직경의 분포를 나타내는 인자로 평균직경과 우세목 수고를 설명변수로 하였으며, 이들은 Weibull 직경분포함수의 모수를 추정하고 복구하는 단계를 거쳤다. 최종적으로는 아까시나무 임분의 평균직경과 우세목 수고로서 직경급별 분포를 나타낼 수 있었으며, 분포 추정에 대한 설명력은 약 80.5%인 것으로 나타났다. 지위지수별 직경분포를 30년생 기준으로 도식화한 결과, 지위지수가 높을수록 직경분포 곡선이 오른쪽으로 이동함을 알 수 있었다. 즉 적지적수를 고려하여 지위지수가 높은 곳에 조림한다면 아까시나무의 생장이 왕성해져 용재생산 뿐만아니라 꿀 생산도 많아질 것임을 유추할 수 있었다. 따라서 본 아까시나무 지위지수분류표와 곡선이 꿀샘식물인 아까시나무를 조성 및 관리함에 있어 의사결정의 기준이 되기를 기대한다.

$Br{\aa}nemark\;Novum^{(R)}$ 즉시 임플랜트 보철 수복 방법에 관한 삼차원 유한요소 분석적 연구 (THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF $BR{\AA}NEMARK\;NOVUM^{(R)}$ IMMEDIATE IMPLANT PROSTHODONTIC PROTOCOL)

  • 김우영;김영수;장경수;김창회
    • 대한치과보철학회지
    • /
    • 제39권5호
    • /
    • pp.463-476
    • /
    • 2001
  • Since the treatment of edentulous patients with osseointegrated implant was first introduced more than 30 years ago, implant therapy has become one of the most important dental treatment modalities today. Based on the previous experience and knowledge, $Br{\aa}nemark\;Novum^{(R)}$ protocol was introduced with the concept of simplifying surgical and prosthetic technique and reducing healing time recently. This protocol recommends the installation of three 5mm wide diameter futures in anterior mandible and the prefabricated titanium bars for superstructure fabrication. This study was designed to analyze the stress distribution at fixture and superstructure area according to changes of fixture number, diameter and superstructure materials. Four 3-dimensional finite element models were fabricated. Model 1 - 5 standard fixtures (13mm long and 3.75mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 2- 3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 3-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and resin Model 4-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and porcelain A 150N occlusal force was applied on the 1st molar of each model in 3 directions - vertical($90^{\circ}$), horizontal($0^{\circ}$) and oblique($120^{\circ}$). After analyzing the stresses and displacements, following results were obtained. 1. There were no significant difference in stress distribution among experimental models. 2. Model 2, 3, 4 showed less amount of compressive stress than that of model 1. However, tensile stress was similar. 3. Veneer material with a high modulus of elasticity demonstrated less stress accumulation in the superstructure. Within the limites of this study, $Br{\aa}nemark\;Novum^{(R)}$ protocol demonstrated comparable biomechanical properties to conventional protocol.

  • PDF

이류체 분사노즐의 혼합영역 형상에 따른 분무특성 (Spray characteristics on mixing region scale of twin fluid atomizer)

  • 김병문;김혁주;이충원
    • 대한기계학회논문집
    • /
    • 제15권6호
    • /
    • pp.2147-2159
    • /
    • 1991
  • 본 연구에서는 가장 다순한 내부혼합형 이류체분사노즐의 기류속도, 액체유량, 노즐직경 및 혼합길이, 기액접촉각을 변화시켜 평균입경(SMD), 분무각, 입도분포, 분 무분사량분포 등을 조사하여 노즐형상에 따른 분무특성의 변화를 자세히 밝혀, 분무특 성을 조절할 수 있는 이류체분사 노즐의 설계에 대한 기초적 자료를 제시하고자 한다.

Critical evaluation of fracture strength testing for endodontically treated teeth: a finite element analysis study

  • Uzunoglu-Ozyurek, Emel;Eren, Selen Kucukkaya;Eraslan, Oguz;Belli, Sema
    • Restorative Dentistry and Endodontics
    • /
    • 제44권2호
    • /
    • pp.15.1-15.8
    • /
    • 2019
  • Objectives: The aim of this study was to investigate whether the diameter and direction of the plunger and simulation of the periodontal ligament (PDL) affected the stress distribution in endodontically treated premolars. Methods: A fracture strength test was simulated via finite element analysis. A base model was set up, and the following parameters were modified: plunger diameter (3 mm vs. 6 mm), plunger direction (vertical vs. $135^{\circ}$ angular to the central fossa), and PDL simulation. The analysis was conducted using the CosmosWorks structural analysis program, and the results are presented in terms of von Mises stresses. Results: The smaller plunger increased the stresses at the contact area of the crown, but the plunger diameter had no effect on the stress distribution within the root. An angular plunger direction increased stresses within the root, as well as at the buccal cusp of the crown, compared with the vertical direction. Simulation of the PDL caused higher stress accumulation, especially in the cervical region of the root. Conclusions: The plunger diameter had no effect on the stress distribution in the roots, whereas the plunger direction and PDL simulation did affect the stress distribution. More stringent standards can be established by taking such parameters into account when performing fracture testing in future studies.