• Title/Summary/Keyword: Diameter Ratio

Search Result 3,088, Processing Time 0.036 seconds

The Findings on Cardiothoracic Ratio in Simple Chest Radiography (Simple chest radiography에서의 심흉비(cardiothoracic ratio) 소견)

  • Kim, Ham-Gyum
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.43-48
    • /
    • 2004
  • The purpose of this study is to measure cardiothoracic ratio and to report the opinions on it, targeting 500 persons who were conducted simple chest radiography, in terms of clinical symptom, by visiting a medical examination center for S university hospital. As to the general characteristic of 500 research targets, it comprised 263 persons (52%) for males and 237 persons (48%), and the average age is 49.4. Out of 500 persons, it showed 125 persons (25%) in their thirties, 125 persons (25%) in their forties, 125 persons (25%) in their fifties, and 125 persons (25%) in their sixties. 1. In terms of the wholly 500 targets, the average value of cardiothoracic ratio was 0.48, and the average cardiothoracic ratio showed 0.45 in their thirties, 0.46 in their forties, 0.50 in their fifties, and 0.53 in their sixties. 2. The minimum value of cardiothoracic ratio was 0.33, and its maximum value was 0.70, and it showed 319 persons (63.8%) as to a case lower than 0.5, which is a normal value, and 181 persons (36.2%) as to a case more than 0.5, which is a normal value. 3. Among 181 persons who showed cardiothoracic ratio higher than normality, it showed 17 persons (9.4%) in their thirties, 22 persons (12%) in their forties, 54 persons (30%) in their fifties, and 88 persons (49%) in their sixties. 4. The average for the internal diameter (ID) of thorax was 141.8 mm, 229.6 mm at the minimum, and 353.5 mm at the maximum. 5. The average for the maximum transverse diameter of right side of the heart (MRD) was 48.0 mm, 4.95 mm at the minimum, and 84.5 mm at the maximum. The average for the maximum transverse diameter of left side of the heart (MLD) was 93.5 mm, 56.7 mm at the minimum, and 138.5 mm at the maximum. 6. The average for TD (MRD+MLD) of the heart was 292.6 mm, 96.6 mm at the minimum, and 199.2 mm at the maximum. 7. The average of cardiothoracic ratio (MRD+MLD/ID) was 0.48, 0.33 at the minimum, and 0.70 at the maximum.

  • PDF

Determination of the Optimal Mixture Ratio for Extrudates of Job's-tear and Wheat Flour by Mixture Design Analysis (혼합실험계획법에 의한 율무와 밀가루의 압출성형 최적 배합 조건 설정)

  • Cho, Seok-Cheol;Kang, Byung-Sun
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.4
    • /
    • pp.473-477
    • /
    • 2013
  • The aim of this study was to identify the optimal ingredient-mixing ratio of Job's-tear and wheat flour subjected to extrusion. A modified distance-based mixture design analysis was chosen for the experimental design. The results showed that the bending failure force, the a-value, and the water absorbtion index (WAI) value had no correlation with the mixture ratio of Job's-tear and wheat flour. However, the diameter of the extrudates, the L- and b-values, and the water solubility index (WSI) value were all found to be correlated to the mixture ratio. While the first three values were determined using a linear model, the WSI value was determined using a quadratic model. The diameter and color had an inverse correlation to the mixture ratio: the higher the ratio of Job's-tear to wheat flour, the lower the diameter and darker the color. The L- and b-values were found to change in accordance with the mixture ratio of Job's-tear to wheat flour. The lowest WSI value was obtained at a 40:60 ratio of Job's-tear to wheat.

Intermittent Atomization Characteristics of Multi-Hole and Single-Hole Diesel Nozzle

  • Lee, Jeekuen;Kang, Shin-Jae;Park, Byungjoon
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.12
    • /
    • pp.1693-1701
    • /
    • 2002
  • The intermittent spray characteristics of a multi-hole and a single-hole diesel nozzle were experimentally investigated. The hole number of the multi-hole nozzle was 5, and the hole diameter of the 5-hole and the single-hole nozzle was the same as d$\_$n/=0.32 ㎜ with the constant hole length to diameter ratio(l$\_$n//d$\_$n/=2.81). The droplet diameters of the spray, including the time-resolved droplet diameter, SMD (Sauter mean diameter) and AMD (arithmetic mean diameter) , injected intermittently from the two nozzles into the still ambient were measured by using a 2-D PDPA (phase Doppler particle analyzer). Through the time-resolved evolutions of the droplet diameter, it was found that the structure of the multi-hole and the single-hole nozzle spray consisted of the three main parts : (a) the leading edge affected by surrounding air. and composed of small droplets; (b) the central part surrounded by the leading edge and mixing flow region and scarcely affected by the resistance of air, (c) the trailing edge formed by the passage of the central part. The SMD decreases gradually with the increase in the radial distance, and the constant value is obtained at the outer region of the radial distance (normalized by hole diameter) of 7-8 and 6 for the 5-hole and single-hole nozzle, respectively. The SMD along the centerline of the spray decrease shapely with the increase in the axial distance after showing the maximum value near the nozzle tip. The SMD remains the constant value near the axial distance(normalized by hole diameter) of 150 and 180 for the 5-hole and the single-hole nozzle, respectively.

Tumor Diameter for Prediction of Recurrence, Disease Free and Overall Survival in Endometrial Cancer Cases

  • Senol, Taylan;Polat, Mesut;Ozkaya, Enis;Karateke, Ates
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7463-7466
    • /
    • 2015
  • Aims: To analyse the predictors of recurrence, disease free survival and overall survival in cases with endometrial cancer. Materials and Methods: A total of 152 women diagnosed with endometrial cancer were screened using a prospectively collected database including age, smoking history, menopausal status, body mass index, CA125, systemic disorders, tumor histology, tumor grade, lymphovascular space invasion, tumor diameter, cervical involvement, myometrial invasion, adnexal metastases, positive cytology, serosal involvement, other pelvic metastases, type of surgery, fertility sparing approach to assess their ability to predict recurrence, disease free survival and overall survival. Results: In ROC analyses tumor diameter was a significant predictor of recurrence (AUC:0.771, P<0.001). The optimal cut off value was 3.75 with 82% sensitivity and 63% specificity. In correlation analyses tumor grade (r=0.267, p=0.001), tumor diameter (r=0.297, p<0.001) and the serosal involvement (r=0.464, p<0.001) were found to significantly correlate with the recurrence. In Cox regression analyses when some different combinations of variables included in the model which are found to be significantly associated with the presence of recurrence, tumor diameter was found to be a significant confounder for disease free survival (OR=1.2(95 CI,1.016-1.394, P=0.031). On Cox regression for overall survival only serosal involvement was found to be a significant predictor (OR=20.8 (95 % CI 2.4-179.2, P=0.006). In univariate analysis of tumor diameter > 3.75 cm and the recurrence, there was 14 (21.9 %) cases with recurrence in group with high tumor diameter where as only 3 (3.4 %) cases group with smaller tumor size (Odds ratio:7.9 (95 %CI 2.2-28.9, p<0.001). Conclusions: Although most of the significantly correlated variables are part of the FIGO staging, tumor diameter was also found to be predictor for recurrence with higher values than generally accepted.

Characteristics of V-belt type continuously variable unit (V-벨트형 무단변속기구의 성능실험)

  • 김연수;박재민;이상희;최상훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.822-825
    • /
    • 2004
  • Continuously variable transmission (CVT) mechanisms considered here is a V-belt drive with two variable-diameter pulleys and effective diameters. One pulley was set by a mechanical link while the other was spring-loaded to provide automatic correspondence. The center distance between the two variable-diameter pulleys was fixed. Experimental studies were executed to analyze efficiencies as change of its speed ratio.

  • PDF

Correction of Various Testing Factors Affecting Measured Compressive Strength of Concrete Core (콘크리트 코어 압축강도의 각종 영향인자 보정)

  • Park, Seok-kyun;Choi, Ook;Oh, Kwang-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.973-978
    • /
    • 2002
  • This study was performed to verify the effect of various testing conditions affecting measured compressive strength of concrete core and to compute the correction coefficients for it. Conditions of specimens affecting test results include size(diameter), height-diameter ratio, humidity of specimen, amount and arrangement of bar, core direction from structure and method of end preparation. In testing core strength of concrete, special cares should be taken on various testing conditions whose effects have been latent in conventional concrete.

  • PDF

Effect of cylinder diameter and boat tail angle on the free vibration characteristics of a typical payload fairing

  • Ramamurti, V.;Rajarajan, S.;Rao, G. Venkateswara
    • Structural Engineering and Mechanics
    • /
    • v.13 no.3
    • /
    • pp.345-353
    • /
    • 2002
  • Three noded plate and shell finite element and 3D beam element in conjunction with Lanczos method are used for studying the effect of boat tail angle on the free vibration characteristics of a typical payload fairing for three different cylinder diameters with height to diameter ratio 1.5. Configurations without boat tail structural member are also studied. One half of the one side fairing structure is considered for the analysis and symmetric boundary conditions are used.

Development of Design Program for Composite Pressure Vessel Type-4 (복합재료 압려용기 Type-4 설계 프로그램 개발)

  • Lee Ho Yong;Joe Chee Ryong
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.10a
    • /
    • pp.224-227
    • /
    • 2004
  • A computer program for composite pressure vtlssel design is developed. In-puts are : material-property(young's modulus, shear modulus, tensile strength, poisson's ratio, density), operating pressure, burst pressure, liner thickness, boss diameter, boss weight and number of helical angles. Out-puts are; thickness of each layer, weight of the vessel, dimension of the vessel, inner volume, dome-shape and helical winding angle. Also filament winding angles can be selected various kinds of utilizing virtual boss diameter.

  • PDF

Analysis on characteristics of vacuum preloaded air bearing (진공 예압형 공기베어링의 특성 해석)

  • 김경호;박천홍;이후상;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.355-358
    • /
    • 2003
  • This paper presents characteristics of vacuum preloaded porous air bearing. Pressure distribution of a porous pad and vacuum pocket are calculated. And load capacity and stiffness of the bearing are analyzed with various vacuum parameters, that is. clearance height. tube diameter, tube length. pumping speed of vacuum pump, vacuum pocket to porous pad area ratio. From the simulation results, optimum clearance for best performance can be selected adjusting these parameters, especially tube diameter which is the most dominant source.

  • PDF

A Study on Producing Electron Beam For the lustallation of Future Energy (차세대 에너지 이용을 위한 전자빔 발생장치에 관한 연구)

  • Kim, Won-Sop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.374-377
    • /
    • 2004
  • We present a detailed design study of high power large diameter backward wave oscillator operating at 24 GHz for a beam energy of 100 keV. The ratio of the mean diameter of the slow wave structure to the wavelength of output microwaves is increased to be 4.8. Analysis is made within the scope of linear theory of absolute instability.

  • PDF