• Title/Summary/Keyword: Diagnostic specificity

Search Result 962, Processing Time 0.028 seconds

Cone-Beam CT-Guided Percutaneous Transthoracic Needle Lung Biopsy of Juxtaphrenic Lesions: Diagnostic Accuracy and Complications

  • Wonju Hong;Soon Ho Yoon;Jin Mo Goo;Chang Min Park
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1203-1212
    • /
    • 2021
  • Objective: To investigate the diagnostic accuracy and complications of cone-beam CT-guided percutaneous transthoracic needle biopsy (PTNB) of juxtaphrenic lesions and identify the risk factors for diagnostic failure and complications. Materials and Methods: In total, 336 PTNB procedures for lung lesions (mean size ± standard deviation [SD], 4.3 ± 2.3 cm) abutting the diaphragm in 326 patients (189 male and 137 female; mean age ± SD, 65.2 ± 11.4 years) performed between January 2010 and December 2014 were included. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the PTNB procedures for the diagnosis of malignancy were measured based on the intention-to-diagnose principle. The risk factors for diagnostic failures and complications were evaluated using logistic regression analysis. Results: The accuracy, sensitivity, specificity, PPV, and NPV were 92.7% (293/316), 91.3% (219/240), 91.4% (74/81), 96.9% (219/226), and 77.9% (74/95), respectively. There were 23 diagnostic failures (7.3%), and lesion sizes ≤ 2 cm (p = 0.045) were the only significant risk factors for diagnostic failure. Complications occurred in 98 cases (29.2%), including 89 cases of pneumothorax (26.5%) and 7 cases of hemoptysis (2.1%). The multivariable analysis showed that old age (> 65 years) (p = 0.002), lesion size of ≤ 2 cm (p = 0.003), emphysema (p = 0.006), and distance from the pleura to the target lesion (> 2 cm) (p = 0.010) were significant risk factors for complications. Conclusion: The diagnostic accuracy of cone-beam CT-guided PTNB of juxtaphrenic lesions for malignancy was fairly high, and the target lesion size was the only significant predictor of diagnostic failure. Complications of cone-beam CT-guided PTNB of juxtaphrenic lesions occurred at a reasonable rate.

Diagnostic Accuracy of Percutaneous Transthoracic Needle Lung Biopsies: A Multicenter Study

  • Kyung Hee Lee;Kun Young Lim;Young Joo Suh;Jin Hur;Dae Hee Han;Mi-Jin Kang;Ji Yung Choo;Cherry Kim;Jung Im Kim;Soon Ho Yoon;Woojoo Lee;Chang Min Park
    • Korean Journal of Radiology
    • /
    • v.20 no.8
    • /
    • pp.1300-1310
    • /
    • 2019
  • Objective: To measure the diagnostic accuracy of percutaneous transthoracic needle lung biopsies (PTNBs) on the basis of the intention-to-diagnose principle and identify risk factors for diagnostic failure of PTNBs in a multi-institutional setting. Materials and Methods: A total of 9384 initial PTNBs performed in 9239 patients (mean patient age, 65 years [range, 20-99 years]) from January 2010 to December 2014 were included. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of PTNBs for diagnosis of malignancy were measured. The proportion of diagnostic failures was measured, and their risk factors were identified. Results: The overall accuracy, sensitivity, specificity, PPV, and NPV were 91.1% (95% confidence interval [CI], 90.6-91.7%), 92.5% (95% CI, 91.9-93.1%), 86.5% (95% CI, 85.0-87.9%), 99.2% (95% CI, 99.0-99.4%), and 84.3% (95% CI, 82.7-85.8%), respectively. The proportion of diagnostic failures was 8.9% (831 of 9384; 95% CI, 8.3-9.4%). The independent risk factors for diagnostic failures were lesions ≤ 1 cm in size (adjusted odds ratio [AOR], 1.86; 95% CI, 1.23-2.81), lesion size 1.1-2 cm (1.75; 1.45-2.11), subsolid lesions (1.81; 1.32-2.49), use of fine needle aspiration only (2.43; 1.80-3.28), final diagnosis of benign lesions (2.18; 1.84-2.58), and final diagnosis of lymphomas (10.66; 6.21-18.30). Use of cone-beam CT (AOR, 0.31; 95% CI, 0.13-0.75) and conventional CT-guidance (0.55; 0.32-0.94) reduced diagnostic failures. Conclusion: The accuracy of PTNB for diagnosis of malignancy was fairly high in our large-scale multi-institutional cohort. The identified risk factors for diagnostic failure may help reduce diagnostic failure and interpret the biopsy results.

Diagnostic and Prognostic Importance of the Neutrophil Lymphocyte Ratio in Breast Cancer

  • Ozyalvacli, Gulzade;Yesil, Cemile;Kargi, Ertugrul;Kizildag, Betul;Kilitci, Asuman;Yilmaz, Fahri
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.23
    • /
    • pp.10363-10366
    • /
    • 2015
  • Background: The aim of this study was to determine diagnostic and prognostic roles of the neutrophil to lymphocyte ratio (NLR) in breast cancer patients. To date, data are limited on associations of primary breast carcinoma (PBC) and benign proliferative breast disease (BPBD) with preoperative NLR values. Materials and Methods: Our study covered of 120 female patients with PBC and 50 with BPBD. Diagnostic values of NLR were estimated using sensitivity, specificity and areas under receiver operating characteristic curves (AUC). Results: NLR values were significantly higher in the PBC patients than in those with BPBD, with an AUC of 0.668 in the PBC case. The optimal cut-off for NLR was 2.96 and this was validated in the testing set, giving a sensitivity and a specificity of 79.7% and 76.2%, respectively, in PBC patients. Conclusions: Preoperative high NLR is a significant diagnostic predictor of distinction of breast cancer from BPBD and elevated NLR is also an important prognostic marker for primary invasive breast cancer.

Support Vector Machine Based Diagnostic System for Thyroid Cancer using Statistical Texture Features

  • Gopinath, B.;Shanthi, N.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.1
    • /
    • pp.97-102
    • /
    • 2013
  • Objective: The aim of this study was to develop an automated computer-aided diagnostic system for diagnosis of thyroid cancer pattern in fine needle aspiration cytology (FNAC) microscopic images with high degree of sensitivity and specificity using statistical texture features and a Support Vector Machine classifier (SVM). Materials and Methods: A training set of 40 benign and 40 malignant FNAC images and a testing set of 10 benign and 20 malignant FNAC images were used to perform the diagnosis of thyroid cancer. Initially, segmentation of region of interest (ROI) was performed by region-based morphology segmentation. The developed diagnostic system utilized statistical texture features derived from the segmented images using a Gabor filter bank at various wavelengths and angles. Finally, the SVM was used as a machine learning algorithm to identify benign and malignant states of thyroid nodules. Results: The SVMachieved a diagnostic accuracy of 96.7% with sensitivity and specificity of 95% and 100%, respectively, at a wavelength of 4 and an angle of 45. Conclusion: The results show that the diagnosis of thyroid cancer in FNAC images can be effectively performed using statistical texture information derived with Gabor filters in association with an SVM.

Diagnostic Accuracy of Dermoscopy for Scabies

  • Li, Feng-Zeng;Chen, Shuang
    • Parasites, Hosts and Diseases
    • /
    • v.58 no.6
    • /
    • pp.669-674
    • /
    • 2020
  • The diagnostic accuracy of dermoscopy (DS) for scabies, a highly contagious parasitic disease, remains disputed. This study aimed to assess the diagnostic accuracy of DS in scabies, analyze the factors influencing DS, and explore its role in post-treatment evaluation. Patients with suspected scabies were randomly divided into 2 groups: 71 patients in the skin scraping (SS) group and 73 patients in the DS group. The diagnostic efficiencies of SS and DS in these groups were calculated. We also analyzed the influence of body part and investigator competence on the accuracy of DS. Then 16 body parts with typical signs of scabies were monitored by DS 2 and 4 day after sulfur ointment treatment. The sensitivity and specificity of DS were 98.3% and 88.5%, respectively. Hands, arms, and the abdomen had higher positivity rates than other body parts (P<0.001). The accuracy of dermatologists' interpretations of images negative for scabies in the intermediate- and high-level groups was higher than that in the low-level group (P<0.001). At follow-up, the mites were still visible on 43.8% to 62.5% of the skin lesions 2 and 4 day after sulfur ointment treatment. These results showed that DS could significantly increase the accuracy of diagnosing scabies owing to its high sensitivity and specificity. Therefore, it may be useful for monitoring clinical responses to anti-parasitic treatment.

Diagnosis of Recurrent Uterine Cervical Cancer: Computed Tomography versus Positron Emission Tomography

  • Dong Hee Park;Kie Hwan Kim;Sang Yoon Park;Byung Hee Lee;Chang Woon Choi;Soo Yil Chin
    • Korean Journal of Radiology
    • /
    • v.1 no.1
    • /
    • pp.51-55
    • /
    • 2000
  • Objective: To determine the accuracy of CT and positron emission tomography (PET) in the diagnosis of recurrent uterine cervical cancer. Materials and Methods: Imaging findings of CT and PET in 36 patients (mean age, 53 years) in whom recurrent uterine cervical cancer was suspected were analyzed retrospectively. Between October 1997 and May 1998, they had undergone surgery and/or radiation therapy. Tumor recurrence was confirmed by pathologic examination or follow-up studies. Results: In detecting recurrent uterine cervical cancer, the sensitivity, specificity, and accuracy of CT were 77.8%, 83.3%, and 80.5%, respectively, while for PET, the corresponding figures were 100%, 94.4%, and 97.2%. The Chi-square test revealed no significant difference in specificity (p = .2888), but significant differences in sensitivity (p = .0339) and accuracy (p = .0244). Conclusion: PET proved to be a reliable screening method for detecting recurrent uterine cervical cancer, but to determine the anatomical localization of recurrent tumors, and thus decide an adequate treatment plan, CT was eventually needed.

  • PDF

Nested-PCR and a New ELISA-Based NovaLisa Test Kit for Malaria Diagnosis in an Endemic Area of Thailand

  • Thongdee, Pimwan;Chaijaroenkul, Wanna;Kuesap, Jiraporn;Na-Bangchang, Kesara
    • Parasites, Hosts and Diseases
    • /
    • v.52 no.4
    • /
    • pp.377-381
    • /
    • 2014
  • Microscopy is considered as the gold standard for malaria diagnosis although its wide application is limited by the requirement of highly experienced microscopists. PCR and serological tests provide efficient diagnostic performance and have been applied for malaria diagnosis and research. The aim of this study was to investigate the diagnostic performance of nested PCR and a recently developed an ELISA-based new rapid diagnosis test (RDT), NovaLisa test kit, for diagnosis of malaria infection, using microscopic method as the gold standard. The performance of nested-PCR as a malaria diagnostic tool is excellent with respect to its high accuracy, sensitivity, specificity, and ability to discriminate Plasmodium species. The sensitivity and specificity of nested-PCR compared with the microscopic method for detection of Plasmodium falciparum, Plasmodium vivax, and P. falciparum/P. vivax mixed infection were 71.4 vs 100%, 100 vs 98.7%, and 100 vs 95.0%, respectively. The sensitivity and specificity of the ELISA-based NovaLisa test kit compared with the microscopic method for detection of Plasmodium genus were 89.0 vs 91.6%, respectively. NovaLisa test kit provided comparable diagnostic performance. Its relatively low cost, simplicity, and rapidity enables large scale field application.

Multicenter Evaluation of Seegene Anyplex TB PCR for the Detection of Mycobacterium tuberculosis in Respiratory Specimens

  • Lim, Jinsook;Kim, Jimyung;Kim, Jong Wan;Ihm, Chunhwa;Sohn, Yong-Hak;Cho, Hyun-Jung;Kim, Jayoung;Koo, Sun Hoe
    • Journal of Microbiology and Biotechnology
    • /
    • v.24 no.7
    • /
    • pp.1004-1007
    • /
    • 2014
  • Culture is the gold standard for diagnosis of tuberculosis, but it takes 6 to 8 weeks to confirm the result. This issue is complemented by the detection method using polymerase chain reaction, which is now widely used in a routine microbiology laboratory. In this study, we evaluated the performance of the Seegene Anyplex TB PCR to assess its diagnostic sensitivity and specificity, and compared its results with the Roche Cobas TaqMan MTB PCR, one of the most widely used assays in the world. Five university hospitals located in the Chungcheong area in South Korea participated in the study. A total of 1,167 respiratory specimens ordered for acid-fast bacilli staining and culture were collected for four months, analyzed via the Seegene Anyplex TB PCR, and its results were compared with the Roche Cobas TaqMan MTB PCR. For detection of Mycobacterium tuberculosis, the diagnostic sensitivity and specificity of the Anyplex TB PCR were 87.5% and 98.2% respectively, whereas those of the Cobas TaqMan were 92.0% and 98.0% respectively (p value > 0.05). For smear-positive specimens, the sensitivity of the Anyplex TB PCR was 95.2%, which was exactly the same as that of the Cobas TaqMan. For smear-negative specimens, the sensitivity of the Anyplex TB PCR was 69.2%, whereas that of the Cobas TaqMan TB PCR was 84.6%. For detection of MTB, the Seegene Anyplex TB PCR showed excellent diagnostic performance, and high sensitivity and specificity, which were comparable to the Roche Cobas TaqMan MTB PCR. In conclusion, the Anyplex TB PCR can be a useful diagnostic tool for the early detection of tuberculosis in clinical laboratories.

Comparison of the diagnostic performance of panoramic and occlusal radiographs in detecting submandibular sialoliths

  • Kim, Jun Ho;Aoki, Eduardo Massaharu;Cortes, Arthur Rodriguez Gonzalez;Abdala-Junior, Reinaldo;Asaumi, Junichi;Arita, Emiko Saito
    • Imaging Science in Dentistry
    • /
    • v.46 no.2
    • /
    • pp.87-92
    • /
    • 2016
  • Purpose: The aim of this study was to assess and compare the diagnostic performance of panoramic and occlusal radiographs in detecting submandibular sialoliths. Materials and Methods: A total of 40 patients (20 cases and 20 controls) were included in this retrospective study. Cases were defined as subjects with a submandibular sialolith confirmed by computed tomography (CT), whereas controls did not have any submandibular calcifications. Three observers with different expertise levels assessed panoramic and occlusal radiographs of all subjects for the presence of sialoliths. Intraobserver and interobserver agreement were assessed using the kappa test. Sensitivity, specificity, accuracy, positive and negative predictive values, and the diagnostic odds ratio of panoramic and occlusal radiographs in screening for submandibular sialoliths were calculated for each observer. Results: The sensitivity and specificity values for occlusal and panoramic radiographs all ranged from 80% to 100%. The lowest values of sensitivity and specificity observed among the observers were 82.6% and 80%, respectively (P=0.001). Intraobserver and interobserver agreement were higher for occlusal radiographs than for panoramic radiographs, although panoramic radiographs demonstrated a higher overall accuracy. Conclusion: Both panoramic and occlusal radiographic techniques displayed satisfactory diagnostic performance and should be considered before using a CT scan to detect submandibular sialoliths.