• Title/Summary/Keyword: Diagnostic sensor

Search Result 239, Processing Time 0.025 seconds

Analysis of Diagnosis and Failsafe Algorithm Using Transmission Simulator (변속기 시뮬레이터를 이용한 진단 및 안전작동 알고리즘 분석)

  • Jung, Gyuhong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.4
    • /
    • pp.89-97
    • /
    • 2014
  • As the digital control technologies in automotive industry have advanced, electronic control units(ECUs) play a key-role to improve system performance. Transmission control unit(TCU) is a shifting controller for automatic transmission of which major functions are to determine the shift and manage the shifting process considering the various sensor signal on transmission and driver's commands. As with any ECU in vehicle, TCU performs complex algorithms such as shift control, diagnostic and failsafe functions. However, firmware design analysis is hardly possible by the reverse engineering due to code protection. Transmission simulator is a hardware-in-the-loop simulator which enables TCU to work in normal mode by simulating the electrical signal of TCU interface. In this research, diagnosis and failsafe algorithm implemented on commercialized TCU is analyzed by using the transmission simulator that is developed for wheel loader construction vehicle. This paper gives various experimental results on the proportional solenoid current trajectories for different operating modes, error detection criterion and limphome mode gears for all the possible cases of clutch malfunction. The derived results for conventional TCU can be applied to the development of inherent TCU algorithms and the transmission simulator can also be utilized for the test of TCU to be developed.

Development of P-5 Transducer or Detection of the Pulse Wave (맥파검출용 트랜스듀서의 개발)

  • Han, S.H.;Kwon, O.S.;Park, S.H.;Hong, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.395-398
    • /
    • 1997
  • Human pulse represents the physical characteristics of heart and cardiovascular system. Therefore, malfunctions and errors of heart and cardiovascular system can be determined by using an automatic diagnosis system that can detect the pulse signal. Not only will the computerised system preclude the possibilities of observational errors by giving an accurate measurement with great stability, but minimize the possibilities of misinterpretation by using an automated diagnostic logic. A new combinational fiber-optic sensor, which has a detecting part and a transmitting part was used to acquire radial pulse signal noninvasively. The development of P-5 transducer makes it possible to obtain more effective detection and obvious display of pulse signals in the aspect of reliability. Using P-5 transducer in the field of plethysomography and MAC- JIN, one of our diagnoses in Korean traditional medicine, it is expected that we can ontain quantitative and valuable information or the diagnosis of human pulses.

  • PDF

Study on a Real Time Quantitative Diagnostic Technique for Measuring CVD Precursors (CVD 공정의 전구체 잔존량 실시간 진단방법 연구)

  • Yun Ju-Young;Shin Yong-Hyoen;Chung Kwang-Hwa
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.3
    • /
    • pp.110-114
    • /
    • 2005
  • This study proposes an accurate method of monitoring precursor consumption in chemical vapor deposition (CVD) systems. Since precursor costs are significant, finding an efficient method to monitor precursor consumption is necessary One example is the use of non-contact and inexpensive ultrasonic sensors for determining the liquid level in a container. In this study, sensors based on ultrasonic techniques have been developed for monitoring the precursor consumption in a CVD system. Moreover, the prototype sensors developed in this study can be useful in the field of semiconductors.

Detection of Radial Pulse by Combinational Fiber-optic Transducer (조합형 광섬유 트랜스듀서에 의한 요골맥파의 검출)

  • Park, Seung-Hwan;Hong, Seung-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.197-202
    • /
    • 1998
  • The human pulse wave is a vital biosignal that includes the diagnostic data related with the heart and the cardiovascular system of human body. Based on the mechanical transducing method, a pulse detection transducer using optical fiber was developed to acquire the pulses non-invasively. To improve the detection efficiency, we proposed a new design that consists of two combinational parts; detecting part, which is in contact with the pulsating skin and transmits the displacement motion of the pulsating skin to the sensing part, and sensing part, which converts the physical quantity transmitted from the detecting part to electronic signal. By using the new method, we confirmed that the proposed transducer can detect the C point(incisura) and the T wave(tidal wave) which is not easily detected by existing transducers.

  • PDF

Development of Multi-scale Model for Concrete Strength Estimation using Intelligent Self-diagnostic sensor (지능형 자가진단센서를 이용한 콘크리트 강도추정을 위한 다중스케일모델 개발)

  • Kim, Dong-Jin;Park, Woong-Ki;Lee, Chang-Gil;Hong, Seok-Inn;Park, Seung-Hee
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.303-306
    • /
    • 2011
  • 본 논문은 콘크리트의 양생 강도 발현을 모니터링하기 위하여 매립형 압전 센서를 이용하여 콘크리트 내부의 임피던스 및 유도초음파 신호를 측정함으로써, 콘크리트의 양생 강도를 실시간 추정할 수 있는 기법을 개발하였다. 임피던스 및 유도초음파 신호는 구조물의 물성을 나타내며 특히 양생 기간 중 임피던스 및 유도초음파의 변화는 해당 콘크리트 구조물의 강도변화를 나타낼 수 있다. 이를 이용하여 매립형 압전 센서로부터 저비용의 셀프 센싱 기반 임피던스 및 유도초음파를 계측하여 콘크리트의 임피던스 공진 주파수 및 유도초음파의 전달 강도를 측정하고 측정된 신호를 통하여 콘크리트 양생 강도를 추정할 수 있게 된다. 제안된 기법의 적용가능성을 검증하기 위하여 설계 압축강도 30MPa의 콘크리트 슬라브 내부에 매립형 압전 센서를 매립하고 양생기간 동안 임피던스 및 유도초음파 신호를 측정, 비교 분석 하였다. 측정된 신호 및 압축강도를 통하여 임피던스 및 유도초음파 기반 강도 추정 모델을 도출하고 보다 높은 정확도를 얻기 위해 다중스케일 강도 추정 모델을 개발하였다. 결과적으로 본 연구를 통해 매립형 압전 센서를 이용하여 콘크리트의 양생 강도를 실시간 모니터링할 수 있음이 검증되었다.

  • PDF

Performance verification and improvement of the frequency analysis unit for GIS Preventive & Diagnostic Monitoring System (GIS 예방진단시스템 주파수 분석장치 성능개선 및 검증)

  • Kim, Won-Gyu;Kim, Min-Soo;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.485-491
    • /
    • 2015
  • This paper shows the design improvement and test model of FAU (Frequency Analysis Unit) in PDD (Partial Discharge Diagnosis system) for 800kV GIS (Gas Insulated Switchgear). We found some problems during operation of previous FAU, such as the aging of fiber-optic converter that can cause communication error, the malfunction of signal analysis circuit etc. And then we solved those problems by design improvement and verified the performance through type test. To monitor partial discharge, the performance of UHF sensor is important but the performance of frequency analysis unit is also very important. So we solved communication error, the malfunction of signal analysis circuit and then increased the operation reliability of FAU by improving fiber-optic converter and signal analysis circuit. Accredited testing laboratory carried out the performance verification test according to performance test criteria and procedure of reliability test standards, IEC-60225, 61000 and 60068 etc. We confirmed the test results which correspond with the performance test criteria.

Simultaneous Diagnostic Assay of Catechol and Caffeine Using an in vivo Implanted Neuro Sensor

  • Ly, Suw-Young;Lee, Chang-Hyun;Jung, Young-Sam;Kwon, O-Min;Lee, Ji-Eun;Baek, Seung-Min;Kwak, Kyu-Ju
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.9
    • /
    • pp.1742-1746
    • /
    • 2008
  • Catechol and caffeine were simultaneously analyzed with a bismuth-immobilized carbon nanotube paste electrode (BPE) using square wave (SW) stripping voltammetry. Optimum analytical conditions were determined. Simultaneous working ranges of 100-1,500 $mgL^{-1}$ for caffeine and 5-75 $mgL^{-1}$ for catechol were obtained. In the separated cell systems, a working range of 0.1-2.1 $mgL^{-1}$ catechol with a correlation coefficient of 0.9935, and a working range of 10-210 $mgL^{-1}$ caffeine with a correlation coefficient of 0.9921 were obtained. A detection limit (S/N) of 0.15 $mgL^{-1}$ (7.7 ${\times}$ $10^{-7}$ M) and a detection limit of 0.02 $mgL^{-1}$ (1.82 ${\times}$ $10^{-7}$ M), respectively, manifested for catechol and caffeine. It was found that three macro-type electrode systems could be implanted in fish and rat neuro cells. For both ions, the ion currents were observed. The physiological impulse conditions and the neuronal thinking current were also obtained.

Quantitative evaluating method for diagnostic ultrasound probe using 3-dimensional acoustic field analysis (3차원 음장 분석법을 이용한 진단용 초음파 프로브의 정량적 성능평가)

  • Noh, Si-Cheol;Kim, Ju-Young;Park, Jae-Hyun;Kim, Jin-Su;Kang, Jung-Hoon;Choi, Heung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.490-496
    • /
    • 2010
  • In this study, in order to overcome the weakness of acoustic field analysis which is generally used for ultrasonic probe performance evaluation, automatic acoustic field measurement system and evaluation parameters were proposed. The comparisons between acoustic field simulation and measured acoustic distribution data of normal and abnormal channels were conducted to evaluate the availability of proposed system and evaluation parameters. First, the impulse response characteristic of sample probe was investigated to classify the normal elements and abnormal elements. And then, normal channels and abnormal channels with abnormal element were chosen. The suggested 12 evaluation parameters were calculated using the acoustic fields of these channels. The availability of proposed automatic acoustic field measurement system and evaluation parameters was confirmed. And the performance evaluation of ultrasonic probe using acoustic field analysis could be easier and faster.

Microcalcification Detection Based on Region Growing Method with Contrast and Edge Sharpness in Digital X-ray Mammographic Images (명암 대비와 에지 선예도를 이용하는 영역 성장법에 의한 디지털 X선 맘모그램 영상에서의 미세 석회화 검출)

  • Won, C.H.;Kang, S.W.;Cho, J.H.
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.56-65
    • /
    • 2004
  • In this paper, we proposed the detection algorithm of microcalcification based on region growing method with contrast and edge sharpness in digital X-ray mammographic images. We extracted the local maximum pixel and watershed regions by using watershed algorithm. Then, we used the mean slope between local maximum and neighborhood pixels to extract microcalcification candidate pixels among local maximum pixels. During increasing threshold value to grow microcalcification region, at the maximum threshold value of the contrast and edge sharpness, the microcalcification area is decided. The regions of which area of grown candidate microcalfication region is larger than that of watershed region are excluded from microcalcifications. We showed the diagnosis algorithm can be used to aid diagnostic-radiologist in the early detection breast cancer.

Development of Multiple Fault Diagnosis Methods for Intelligence Maintenance System (지적보전시스템의 실시간 다중고장진단 기법 개발)

  • Bae, Yong-Hwan
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.1
    • /
    • pp.23-30
    • /
    • 2004
  • Modern production systems are very complex by request of automation, and failure modes that occur in thisautomatic system are very various and complex. The efficient fault diagnosis for these complex systems is essential for productivity loss prevention and cost saving. Traditional fault diagnostic system which perforns sequential fault diagnosis can cause catastrophic failure during diagnosis when fault propagation is very fast. This paper describes the Real-time Intelligent Multiple Fault Diagnosis System (RIMFDS). RIMFDS assesses current machine condition by using sensor signals. This system deals with multiple fault diagnosis, comprising of two main parts. One is a personal computer for remote signal generation and transmission and the other is a host system for multiple fault diagnosis. The signal generator generates various faulty signals and image information and sends them to the host. The host has various modules and agents for efficient multiple fault diagnosis. A SUN workstation is used as a host for multiple fault modules and agents for efficient multiple fault diagnosis. A SUN workstation is used as a host for multiple fault diagnosis and graphic representation of the results. RIMFDS diagnoses multiple faults with fast fault propagation and complex physical phenomenon. The new system based on multiprocessing diagnoses by using Hierarchical Artificial Neural Network (HANN).