6.6 kV 케이블의 절연저항 측정을 위한 부하전류 및 온도 측정 (Load Current and Temperature Measurement for Measuring the Insulation Resistance of the 6.6 kV Cable)

  • 박용규;조영식;이관우;엄기홍;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제28권1호
    • /
    • pp.46-50
    • /
    • 2015
  • The cable degradation process is largely divided into three steps; Step 1 : Thermal degradation, Step 2 : Weibull degradation, Step 3 : Partial discharge. it is progress in step order. This article aims to explain the process of cable degradation using the method of insulation resistance and accordingly to compose and manufacture a system of measuring the life of electrical cable. Before measuring the insulation resistance, a system of measuring the temperature and current of cables was made, and the established system was installed for test on the site of a power plant to collect the measured data. The current sensor was used TFC30P80A-CL420, and temperature sensor was used the DK-1270 PT100 sensor as RTD sensor. When measured the temperature and the load current at the same position, was confirmed that in case of the load current value was high, also temperature value high. Therefore, the correlation between load currents and temperature was verified, and the analysis of diagnostic data was evaluated, which could be utilized in identifying the fault condition of cable systems.

긴급환자 상황인식 및 분석을 위한 무선 ECG모니터링 시스템 (A Wireless ECG monitoring System for Application in Life Emergency Event Detection and Analysis)

  • ;이대석;정완영
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2006년도 춘계종합학술대회
    • /
    • pp.421-425
    • /
    • 2006
  • 헬스케어와 무선 기술의 접목은 새로운 생체신호 모니터링 방법과 환자의 이동성 및 편의성을 제공하며 더 나은 방법으로 환자를 돌볼 수 있으며 이러한 장점으로 인해 최근 무선기술을 이용한 ECG 모니터링 및 계측 시스템이 개발되고 있다. 본 논문에서는 중요한 생체신호 중 가장 중요한 신호의 하나인 ECG 신호를 무선센서네트워크를 이용하여 무선으로 받은 후, 이를 서버컴퓨터에서 의사, 간호사 또는 환자의 보호자에게 진단의 기초자료로 제공할 수 있게 빈맥, 서맥, 동정지와 같은 비정상적인 ECG신호를 판단하는 ECG 모니터링 시스템을 구현하였다. 신체에서 계측된 ECG신호는 무선으로 서버와 RS-232로 연결된 베이스스테이션으로 전송되고 서버는 비정상적인 ECG 신호를 검사하여 저장 및 모니터링을 위해 PC/PDA로 데이터를 전송하며, 이러한 시스템을 활용하여 의료비 절감 및 더 편리한 의료서비스를 받을 수 있을 것으로 예상된다.

  • PDF

Power CT를 이용한 USN 센서노드용 자율독립전원 시스템 설계 (Design of Autonomous Independent Power System for USN Sensor Node Using Power CT)

  • 손원국;정재기
    • 한국정보기술학회논문지
    • /
    • 제16권12호
    • /
    • pp.101-107
    • /
    • 2018
  • 다양한 분야에 적용이 확대되고 있는 무선 센서 네트워크 기술은 센서들의 전력공급 및 전원관리 문제가 가장 큰 핵심이 되고 있다. 이러한 이유에서 새로운 개념의 전력공급장치와 전원관리장치가 요구된다. 이에 본 논문에서는 송전선에 흐르는 전류를 이용하여 전자기유도 원리에 의한 에너지 하베스팅 기술을 적용하여 별도의 외부 입력 없이 센서노드에 안정적인 전력을 공급하는 자율독립전원 시스템을 개발하였다. 제안한 자율독립전원 시스템은 Power CT를 활용한 전력공급장치와 충전회로를 포함한 전원관리장치로 구성되었다. 전원관리장치는 배터리의 충전의 안전성을 확보하기 위하여 전압제한회로, 충전전압/전류 모니터링 회로를 적용하였다. 제안된 시스템의 성능검증을 위하여 SVL진단장치에 적용하여 실험한 결과 안정적으로 운용됨을 확인할 수 있었다.

퍼지알고리즘을 이용한 전기전자기기의 안전진단방법에 대한 연구 (Study on the method of safety diagnosis of electrical equipments using fuzzy algorithm)

  • 이재철
    • 디지털융복합연구
    • /
    • 제16권7호
    • /
    • pp.223-229
    • /
    • 2018
  • 최근 전기기기로 인한 화재발생이 급증함에 따라 기기에 대한 안전진단의 필요성이 높아지고 있다. 본 연구는 지능형의 Fuzzy기술을 이용한 전기기기의 안전진단에 관한 것으로 기기의 사용전류특성, 누적사용시간, 열화특성 및 Arc특성 등의 복합적인 전기안전 요인을 검출하여 진단한다. 이들 안전요인을 실시간으로 추출하기 위하여 각종 Sensor회로, DSP(Digital Signal Processor) 신호처리회로, 무선통신회로 등으로 구성된 Board를 설계하였고, 추출된 4가지 진단정보를 이용하여, 기기의 안전정도를 퍼지수치 값으로 표시하기 위하여 각 정보마다 Gaussian function을 사용한 퍼지 알고리즘을 설계하고 DSP에 실장 하였다. 지능적인 퍼지알고리즘은 4가지의 진단정보를 입력받아 퍼지엔진으로 추론하고 해당기기의 종합적인 안전 상태를 사람의 감성에 익숙한 100단계의 아날로그 퍼지 값으로 출력한다. 본 연구에서 구현된 DSP 하드웨어와 퍼지 알고리즘을 융합한 보드의 실험을 통하여, 전기기기의 운전 중 실시간 안전 상태를 복합적으로 검출하고, 사람에게 친화적인 감성적 퍼지 값으로 진단결과를 출력하는 기능을 소형의 DSP Board에서 구현할 수 있음을 입증하였다. 향후 인공지능 전용 Micom이 출시된다면 지능을 바탕으로 보다 진보된 진단 시스템을 연구할 수 있을 것으로 기대한다.

시간영역반사계를 이용한 해수배관시스템의 누수 탐지용 센서 개발 연구 (Development of TDR-based Water Leak Detection Sensor for Seawater Pipeline of Ship)

  • 황현규;신동호;김헌희;이정형
    • 해양환경안전학회지
    • /
    • 제28권6호
    • /
    • pp.1044-1053
    • /
    • 2022
  • 시간영역반사계(TDR)는 케이블의 물리적 결함을 검사하는 기법이며 누수 탐지 분야로의 응용영역을 확대하고 있다. 본 연구는 시간영역반사계 기법을 활용하여 선박 기관실 해수 배관의 누설 감지용 케이블형 센서를 개발하였다. 케이블 센서의 형상은 꼬임형상과 흡습부재를 이용하여 제작하였으며 개발된 센서의 누수 감지 여부와 위치 탐지 가능성을 확인하였다. 개발된 센서는 실제 배관 시험 장치에 부착하여 평가하였으며 해수 누설에 따른 다양한 TDR 신호를 취득하였다. 센서는 꼬임횟수, 피복 두께를 변수로 하여 제작하였으며 TDR 신호에 미치는 효과를 분석하였다. 실험 결과, 꼬임형 센서는 평행한 띠 형상의 센서에 비해 평활한 신호 취득이 가능하였으며 최적 꼬임 횟수는 단위길이 당 10회 이상인 것으로 나타났다. 절연 피복두께의 경우 적정 민감도 확보가 가능한 절연 피복부재의 두께는 도선직경의 80%~120%로 확인되었다. 누수 위치 추정을 위해 회귀분석 실시 결과, 결정계수는 0.9998로 실제 누설 위치와 높은 상관관계를 나타내었다. 결과적으로 제안된 TDR 기반의 누수 감지용 꼬임형 센서는 해수 배관 시스템의 누수 감시 센서로의 충분한 적용성을 확인하였다.

맥진기술동향 조사를 통한 맥진기 개발방안 제안 (Suggestion on an Innovative Pulse Diagnosis System based on Technical Trend Analysis)

  • 이유정;이전;김종열
    • 동의생리병리학회지
    • /
    • 제23권1호
    • /
    • pp.174-179
    • /
    • 2009
  • Arterial pulse palpation is an important diagnostic method in Oriental Medicine, particularly for obtaining information about a patient's health conditions or illness, or for confirming a diagnostic conclusion based on the patient's pulsation. The pulse analyzer is both a leading Oriental Medical equipment and a promising tool with such a strong industrial ripple effect that it was selected as one of the four strategic tools for world Oriental Medical instrument market domination at a recent survey. Although various pulse analyzers had been developed, however, most of these were not widely used for clinical diagnosis, due perhaps to lack of the appliance's reliability caused by its inability to reflect the requirements of the clinicians. Thus, in this thesis, the clinical requirements for the pulse analyzer were identified and analyzed by conducting a questionnaire survey among Oriental Medicine clinicians. By looking into the basic functions of a pulse analyzer, the required measurement time, and the medical insurance fee required were determined and among others, the appliance's specific requirements were determined. Moreover, by investigating on the latest patent trend, the technical elements that are needed for the development of a next-generation pulse analyzer were identified. Through these processes, the flow of the technology that must be developed for the pulse analyzer was determined, and the direction for the development of the specific pulse analyzer hardware, sensor, and diagnostic algorithm was identified and proposed.

GIS 진단시스템의 평가를 위한 PD 모의 펄스발생기 개발에 관한 연구 (A Study on the Development of PD Simulation Pulse Generator for Evaluation of GIS Diagnosis System)

  • 김성주;장석훈;조국희
    • 한국안전학회지
    • /
    • 제33권2호
    • /
    • pp.21-27
    • /
    • 2018
  • The expansion and stable operation of electric power facilities are important factors with development of industrial facilities in modern society. In high-voltage equipment such as GIS, the insulation characteristics may be deterioated by environment-friendly gas adaption and miniaturization. There is also the possibility of accidents due to insulation breakdown due to the deterioration of power facilities. Therefore, it is necessary to extend the diagnosis system to continuously monitor the danger signals of these power equipment and to prevent accidents. Most of the internal defects in the GIS system are conductive particles, floating electrode defects, protrusion defects, and the like. In this case, a partial discharge phenomenon is accompanied. These partial discharge signals occur irregularly and various noise signals are included in the field, so it is difficult to evaluate the reliability in the development of the diagnostic system. In this paper, a study was made on equipment capable of generating a partial discharge simulated signal that can be adjusted in size and frequency to be applied to a diagnostic device by electromagnetic wave detection method. The PD simulated pulse generator consists of a user interface module, a high-voltage charging module, a pulse forming circuit, a voltage sensor and an embedded controller. In order to simulate the partial discharge phenomenon similar to the actual GIS, a discharge cell was designed and fabricated. The application of the prototype pulse generator to the commercialized PD diagnosis module confirmed that it can be used to evaluate the performance of the diagnostic device. It can be used for the development of GIS diagnosis system and performance verification for reliability evaluation.

CRISPR/Cas 진단의 원리와 현황 (The Principle and Trends of CRISPR/Cas Diagnosis)

  • 박지웅;강봉근;신화희;신준근
    • 대한의용생체공학회:의공학회지
    • /
    • 제42권3호
    • /
    • pp.125-142
    • /
    • 2021
  • The POCT (point-of-care test) sensing that has been a fast-developing field is expected to be a next generation technology in health care. The POCT sensors for the detection of proteins, small molecules and especially nucleic acids have lately attracted considerable attention. According to the World Health Organization (WHO), the POCT methods are required to follow the ASSURED guidelines (Affordable, Sensitive, Specific, User- friendly, Robust and rapid, Equipment-free, Deliverable to all people who need the test). Recently, several CRISPR (Clustered Regularly Interspaced Short Palindromic Repeats) based diagnostic techniques using the sensitive gene recognition function of CRISPR have been reported. CRISPR/Cas (Cas, CRISPR associated protein) systems based detection technology is the most innovative gene analysis technology that is following the ASSURED guidelines. It is being re-emerged as a powerful diagnostic tool that can detect nucleic acids due to its characteristics that enable rapid, sensitive and specific analyses of nucleic acid. The first CRISPR-based diagnosis begins with the discovery of the additional function of Cas13a. The enzymatic cleavage occurs when the conjugate of Cas protein and CRISPR RNA (crRNA) detect a specific complementary sequence of the target sequence. Enzymatic cleavage occurs on not only the target sequence, but also all surrounding non-target single-stranded RNAs. This discovery was immediately utilized as a biosensor, and numerous sensor studies using CRISPR have been reported since then. In this review, the concept of CRISPR, the characteristics of the Cas protein required for CRISPR diagnosis, the current research trends of CRISPR diagnostic technology, and some aspects to be improved in the future are covered.

휴대용 전자 후각 장치에서 다채널 마이크로 센서 신호의 영상 정합을 이용한 가스 인식 (Vapor Recognition Using Image Matching of Micro-Array Sensor Response from Portable Electronic Nose)

  • 양윤석
    • 전자공학회논문지SC
    • /
    • 제48권2호
    • /
    • pp.64-70
    • /
    • 2011
  • 휴대용 인공 전자 후각 시스템 (E-nose)의 가스 측정 환경은 실험실 내의 정교하게 제어되는 환경과 달리 온도, 농도, 기체 시료의 유속 등의 외부 요인의 변동이 매우 심하다. 이런 환경에서도 사용 가능한 단순하고 강인하고 정확한 가스 패턴 인식 알고리듬의 개발은 마이크로 바이오 센서의 발달과 함께 확대되고 있는 휴대용 및 소형 측정 진단 시스템에 있어 매우 중요하다. 본 연구에서는 PDA 기반의 휴대용 전자 후각 시스템을 활용해 실제 변화하는 환경에서 다채널 마이크로 센서로부터 감지되는 가스 신호를 수집하고, 여기에 영상 정합 기법을 적용하여 알고리듬의 강인성과 향상된 정확도를 검증하는 것을 목표로 하였다. 제안된 방법을 6종류의 가스 시료에 대한 7채널 마이크로 센서의 휴대 환경 측정 데이터에 적용하고, 기존의 최대 민감도 특징 추출 기법과 비교한 결과, 외부 환경의 변동에 영향 받지 않는 안정된 인식 성능 뿐 아니라 기존의 방법으로 구별하기 어렵던 2 종의 유사한 가스 시료에 대해서도 정확한 구분이 가능함을 보였다. 제안된 방법은 다양한 환경 변화에 노출되는 유비쿼터스 센서 네트워크 (USN)의 데이터 처리에도 쉽게 응용될 수 있을 것이며, 응용 현장에서 높은 안정성과 정확성을 요구하는 휴대용 의료 진단, 환경 감지 기술의 실용화에 큰 도움을 줄 수 있을 것으로 기대한다.

CNN기반 정규화 리사주 도형을 이용한 전자식 밸브 고장진단알고리즘 (Fault Diagnosis Algorithm of Electronic Valve using CNN-based Normalized Lissajous Curve)

  • 박성미;고재하;송성근;박성준;손남례
    • 한국산업융합학회 논문집
    • /
    • 제23권5호
    • /
    • pp.825-833
    • /
    • 2020
  • Currently, the K-Water uses various valves that can be remotely controlled for optimal water management. Valve system fault can be classified into rotor defects, stator defects, bearing defects, and gear defects of induction motors. If the valve cannot be operated due to a gear fault, the water management operation can be greatly affected. For effective water management, there is an urgent need for preemptive repairs to determine whether gear is damaged through failure prediction diagnosis.. Recently, deep learning algorithms are being applied for valve failure diagnosis. However, the method currently applied has a disadvantage of attaching a vibration sensor to the valve. In this paper, propose a new algorithm to determine whether a fault exists using a convolutional neural network (CNN) based on the voltage and current information of the valve without additional sensor mounting. In particular, a normalized Lisasjous diagram was used to maximize the fault classification performance in the CNN-based diagnostic system.