• 제목/요약/키워드: Diagnostic parameters

검색결과 561건 처리시간 0.028초

이종분산 고장 진단을 위한 지식표현 방법 및 진단 방법의 개발 (Development of a Knowledge Representation Scheme and Diagnosis Mechanism for Heterogeneous Distributed Fault Diagnosis)

  • 안영애;박종희
    • 전자공학회논문지B
    • /
    • 제32B권12호
    • /
    • pp.1687-1696
    • /
    • 1995
  • An integrated fault diagnosis system for heterogeneous manufacturing environments is developed. This system has a contrast with existing diagnosis systems in the respect that they are mostly for diagnosing faults on individual machines. In addition to the usual (e.g., audio, electrical) diagnostic signals, the characteristics of products from the machines are considered as the unifying diagnostic parameters among heterogeneous machines in the diagnosis. The system is composed of a knowledge representation scheme and a diagnostic query processing mechanism. Its knowledge representation scheme allows the diagnostic knowledges from heterogeneous unit diagnostic systems to be uniformly expressed in terms of the causal relations among relevant data items. It is flexible in the sense that causes for one relation can be effects for another may be reflected on our knowledge representation scheme. The diagnosis mechanism is based on a probabilistic inferencing method. This probablistic diagnosis mechanism provides more general diagnosis than existing ones in that it accommodates multiple causes and takes complication among causes into account. These scheme and mechanism are applied to a typical example to demonstrate how our system works.

  • PDF

Fast Measurement using Wave-Cutoff Method

  • 서상훈;나병근;유광호;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.30-30
    • /
    • 2011
  • The wave-cutoff tool is a new diagnostic method to measure electron density and electron temperature. Most of the plasma diagnostic tools have the disadvantage that their application to processing plasma where toxic and reactive gases are used gives rise to many problems such as contamination, perturbation, precision of measurement, and so on. We can minimize these problems by using the wave-cutoff method. Here, we will present the results obtained through the development of the wave-cutoff diagnostic method. The frequency spectrum characteristics of the wave-cutoff probe will be obtained experimentally and analyzed through the microwave field simulation by using the CST-MW studio simulator. The plasma parameters are measured with the wave-cutoff method in various discharge conditions and its results will be compared with the results of Langmuir probe. Another disadvantage is that other diagnostic methods spend a long time (~ a few seconds) to measure plasma parameters. In this presentation, a fast measurement method will be also introduced. The wave-cutoff probe system consists of two antennas and a network analyzer. The network analyzer provides the transmission spectrum and the reflection spectrum by frequency sweeping. The plasma parameters such as electron density and electron temperature are obtained through these spectra. The frequency sweeping time, the time resolution of the wave-cutoff method, is about 1 second. A short pulse with a broad band spectrum of a few GHz is used with an oscilloscope to acquire the spectra data in a short time. The data acquisition time can be reduced with this method. Here, the plasma parameter measurement methods, Langmuir probe, pulsed wave-cutoff method and frequency sweeping wave-cutoff method, are compared. The measurement results are well matched. The real time resolution is less than 1 ?sec. The pulsed wave-cutoff technique is found to be very useful in the transient plasmas such as pulsed plasma and tokamak edge plasma.

  • PDF

Deoxynivalenol에 의한 생체독성 스크리닝 및 중독증 진단지표 확립 (Clinical and Toxico-pathological Parameters for Deoxynivalenol Intoxication in B6C3F1 Mice)

  • 김은주;정상희;구현옥;강환구;조준형
    • Toxicological Research
    • /
    • 제23권4호
    • /
    • pp.353-362
    • /
    • 2007
  • Deoxynivalenol (DON) is a common food borne mycotoxin and occurs predominantly in grains such as wheat, barley, oats, etc. DON induces systemic health problems such as loss of appetite, emesis and diarrhea in both human and farm animals. Reliable diagnostic parameters for DON intoxication are needed to prevent deep health impact. In order to establish useful diagnostic parameters, we investigated clinical signs, hematological values, serum biochemical values, gross-, histo- and toxico-pathological findings in B6C3F1 male mice after oral administration of DON (0.83, 2.5 and 7.5 mg/kg) for 8 days. Body weight gain was significantly decreased at the highest dose of DON. Anorexia, ataxia, for crudness and lack of vigor were observed at the highest dose DON group. In hematological values, the numbers of WBC and platelets and hemoglobin content were reduced with decreased neutrophil and monocytes by 7.5 mg/kg DON. Prothrombin time (PT) and activated partial thromboplastin time (aPTT) were prolonged in a dose-dependent manner and the content of fibrinogen was elevated at high dose of DON. Of serum biochemical values, total protein, globulin, BUN, cholesterol and test-osterone were reduced but total bilirubin and albumin/globulin ratio increased. The enzyme activity of alkaline phosphatase was decreased while that of alanine aminotransferase was elevated. Relative organ weights of thymus, seminal vesicle/prostate and testes were dose-dependently reduced but those of liver and left adrenal gland increased with dose dependency. As for pathological findings, atrophy of thymus, seminal vesicle/prostate and testes and submucosal edema and ulceration in stomach and depletion of lymphocytes in thymus cortex were observed. In conclusion, these clinical, hematological, blood biochemical and patholgical parameters obtained in the present studies can be used for diagnosis of DON-mycotoxicosis, especially, low WBC, platelets, protein, BUN and testosterone and delayed prothrombin time can be available as for reliable diagnostic parameters.

500명 여성을 대상으로 한 팔강변증에 따른 맥파 특성 연구 (A Study on the Characteristics of Pulse Waves according to Eight Principle Pattern Identification in 500 Women)

  • 이인선;전수형;강창완;김종원
    • 동의생리병리학회지
    • /
    • 제35권6호
    • /
    • pp.274-279
    • /
    • 2021
  • This study was conducted to find objective diagnostic indicators for the Eight Principle Pattern Identification using a pulse wave analyzer. Typology Complexion Pulse and Symptom data from 500 women over the age of 18 were used. Five experts made a diagnosis of Eight Principle Pattern Identification and divided the subjects into 'Yin-Yang', 'Exterior-Interior', 'Cold-Heat', 'Deficiency-Excess' groups. Their pulse waves were measured in the left and right radial arteries, and it was investigated whether there was a significant difference between groups in the pulse wave parameter values. 'Yin' group showed a significantly lower value in the left radial artery for Ener, Emin, EIX, T4T, T4TT parameters and in the Right for T2, T2T, T5. The Vmag, As and Ad parameters were significantly different between the 'Exterior' and 'Interior' groups. 'Heat' group showed a significantly higher value in the right radial artery for RAI/t parameter. 'Deficiency' group showed a significantly higher value in the right radial artery for W, Angl parameters. Through this study, significant pulse wave parameters were found, and they can be used as objective diagnostic indicators for Eight Principle Pattern Identification.

Combination of Quantitative Parameters of Shear Wave Elastography and Superb Microvascular Imaging to Evaluate Breast Masses

  • Eun Ji Lee;Yun-Woo Chang
    • Korean Journal of Radiology
    • /
    • 제21권9호
    • /
    • pp.1045-1054
    • /
    • 2020
  • Objective: This study aimed to evaluate the diagnostic value of combining the quantitative parameters of shear wave elastography (SWE) and superb microvascular imaging (SMI) to breast ultrasound (US) to differentiate between benign and malignant breast masses. Materials and Methods: A total of 200 pathologically confirmed breast lesions in 192 patients were retrospectively reviewed using breast US with B-mode imaging, SWE, and SMI. Breast masses were assessed based on the breast imaging reporting and data system (BI-RADS) and quantitative parameters using the maximum elasticity (Emax) and ratio (Eratio) in SWE and the vascular index in SMI (SMIVI). The area under the receiver operating characteristic curve (AUC) value, sensitivity, specificity, accuracy, negative predictive value, and positive predictive value of B-mode alone versus the combination of B-mode US with SWE or SMI of both parameters in differentiating between benign and malignant breast masses was compared, respectively. Hypothetical performances of selective downgrading of BI-RADS category 4a (set 1) and both upgrading of category 3 and downgrading of category 4a (set 2) were calculated. Results: Emax with a cutoff value of 86.45 kPa had the highest AUC value compared to Eratio of 3.57 or SMIVI of 3.35%. In set 1, the combination of B-mode with Emax or SMIVI had a significantly higher AUC value (0.829 and 0.778, respectively) than B-mode alone (0.719) (p < 0.001 and p = 0.047, respectively). B-mode US with the addition of Emax, Eratio, and SMIVI had the best diagnostic performance of AUC value (0.849). The accuracy and specificity increased significantly from 68.0% to 84.0% (p < 0.001) and from 46.1% to 79.1% (p < 0.001), respectively, and the sensitivity decreased from 97.6% to 90.6% without statistical loss (p = 0.199). Conclusion: Combining all quantitative values of SWE and SMI with B-mode US improved the diagnostic performance in differentiating between benign and malignant breast lesions.

A CHARACTERISTIC PLANETARY FEATURE IN CAUSTIC-CROSSING HIGH-MAGNIFICATION MICROLENSING EVENTS

  • Kim, Do-Eon;Han, Cheong-Ho
    • 천문학회지
    • /
    • 제42권3호
    • /
    • pp.33-37
    • /
    • 2009
  • We propose a diagnostic that can resolve the planet/binary degeneracy of central perturbations in caustic-crossing high-magnification microlensing events. The diagnostic is based on the difference in the morphology of perturbation inside the central caustics induced by a planet and a wide-separation binary companion. We find that the contours of excess exhibit a concentric circular pattern around the caustic center for the binary-lensing case, while the contours are elongated or off-centered for the planetary case. This difference results in the distinctive features of the individual lens populations in the residual of the trough region between the two peaks of the caustic crossings, where the shape of the residual is symmetric for binary lensing while it tends to be asymmetric for planetary lensing. We determine the ranges of the planetary parameters for which the proposed diagnostic can be used. The diagnostic is complementary to previously proposed diagnostics in the sense that it is applicable to caustic-crossing events with small finite-source effect.

웹기반 보안 관리 수준 분석 도구 (Tools for Web-Based Security Management Level Analysis)

  • 김점구;최경호;노시춘;이도현
    • 융합보안논문지
    • /
    • 제12권3호
    • /
    • pp.85-92
    • /
    • 2012
  • 기존의 보안 관리 수준을 측정하기 위한 방법들이 다양하지만 IT 자산을 중심으로 한 평가만이 이루어지고 있는 관계로 조직 전반에 걸친 분석이 이루어지지 못했다. 따라서 본 논문에서는 보안 관리 수준 점검을 손쉽게 할 수 있도록 웹 기반 보안 관리 수준 분석 도구에 대해 제시한다. 본 도구의 경우는 전사적 정보 보호 관리 방법론인 ISO 27001의 보안통제 항목들을 기반으로 설문 내용을 구성하였다.

Case Deletion Diagnostics for Intraclass Correlation Model

  • Kim, Myung Geun
    • Communications for Statistical Applications and Methods
    • /
    • 제21권3호
    • /
    • pp.253-260
    • /
    • 2014
  • The intraclass correlation model has a long history of applications in several fields of research. Case deletion diagnostic methods for the intraclass correlation model are proposed. Based on the likelihood equations, we derive a formula for a case deletion diagnostic method which enables us to investigate the influence of observations on the maximum likelihood estimates of the model parameters. Using the Taylor series expansion we develop an approximation to the likelihood distance. Numerical examples are provided for illustration.

Laser Diagnostic in a Plasma Display Panel Discharge Cell

  • Choi, Young-Wook
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2000년도 제1회 학술대회 논문집
    • /
    • pp.21-22
    • /
    • 2000
  • Laser diagnostic method in a plasma display discharge cell was introduced. The information of electric field, potential and electron temperature et al. in the surface of plasma display panel can be measured using laser induced fluorescence spectroscopy. However, because of the very small discharge dimension of ${\sim}$ 100 ${\mu}m$, the measurement attempt has almost not been performed. In this paper, the direct measurement possibility of the parameters and the recent work of electric field measurement are demonstrated in the plasma display panel.

  • PDF

RECEMT DEVELOPMENTS IN REAL-TIME MRI

  • Riederer, Stephen J.
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.67-72
    • /
    • 2002
  • Real-time techniques are motivated by a number of factors including the potential for direct acquisition of diagnostic quality images, facilitation of patient-specific imaging parameters, and reduced examination time. Real-time MRI includes not only a rapid pulse sequence but also high speed image reconstruction and easy interactivity. The frame rate of the real-time technique used should be matched to the physiological timeframes under study. Principal applications thusfar have been in localization, fluoroscopic triggering, guidance of other processes, and potentially in the generation of diagnostic images of moving structures.

  • PDF