Evaluation to X-ray Tube Variable Beam Limiting Device Ability Test, Collimation and Beam Alignment Test of Diagnostic X-ray Unit (진단용 X선발생장치의 X선관 가변조리개 성능검사와 조사야일치검사 및 중심선속 일치검사에 대한 평가)

  • Im, In-Chul;Lee, Sang-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.3
    • /
    • pp.250-255
    • /
    • 2009
  • This study performed and evaluated the performance test in 40 general X-ray units among diagnostic X-ray units, which were being used in hospitals of gyeongsangnam-do gimhae-si through X-ray tube variable limiting device ability test, the light field and X-ray field alignment test and collimation and beam alignment test of diagnostic X-ray unit. The results are as followings: In a variable beam limiting device ability test, the result of maximum X-ray field test showed that 4(10%) of were incongruent while the result of minimum X-ray field test represented that 5(12.5%) of were incongruent. The result of the light field and X-ray field alignment test showed 23(57.5%) of were within 2% of maximum permissible level and the other 17(42.5%) units were misalignment. The result of beam alignment test represented that 11(27.5%) coincided and another 11(27.5%) within $0.5^{\circ}$ respectively, 10(25%) were $0.6^{\circ}-1.5^{\circ}$ intervals, 7(17.5%) were $1.6^{\circ}-3^{\circ}$ and 1(2.5%) were more than $3^{\circ}$.

A Study on the Development of PD Simulation Pulse Generator for Evaluation of GIS Diagnosis System (GIS 진단시스템의 평가를 위한 PD 모의 펄스발생기 개발에 관한 연구)

  • Kim, Sungju;Chang, Sughun;Cho, Kook-hee
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.2
    • /
    • pp.21-27
    • /
    • 2018
  • The expansion and stable operation of electric power facilities are important factors with development of industrial facilities in modern society. In high-voltage equipment such as GIS, the insulation characteristics may be deterioated by environment-friendly gas adaption and miniaturization. There is also the possibility of accidents due to insulation breakdown due to the deterioration of power facilities. Therefore, it is necessary to extend the diagnosis system to continuously monitor the danger signals of these power equipment and to prevent accidents. Most of the internal defects in the GIS system are conductive particles, floating electrode defects, protrusion defects, and the like. In this case, a partial discharge phenomenon is accompanied. These partial discharge signals occur irregularly and various noise signals are included in the field, so it is difficult to evaluate the reliability in the development of the diagnostic system. In this paper, a study was made on equipment capable of generating a partial discharge simulated signal that can be adjusted in size and frequency to be applied to a diagnostic device by electromagnetic wave detection method. The PD simulated pulse generator consists of a user interface module, a high-voltage charging module, a pulse forming circuit, a voltage sensor and an embedded controller. In order to simulate the partial discharge phenomenon similar to the actual GIS, a discharge cell was designed and fabricated. The application of the prototype pulse generator to the commercialized PD diagnosis module confirmed that it can be used to evaluate the performance of the diagnostic device. It can be used for the development of GIS diagnosis system and performance verification for reliability evaluation.

An Exploratory Study on the Possibility of Quantitative Measurement during Abdominal Examinations - A Preliminary Study on the Development of a Diagnostic Device for Abdominal Examinations (한의복진법의 정량화를 위한 탐색적 임상연구 - 한의 복진기기 개발을 위한 예비 연구 -)

  • Lee, Jae-hong;Kim, Sang-jin;Ko, Seok-jae;Park, Jae-woo
    • The Journal of Internal Korean Medicine
    • /
    • v.37 no.6
    • /
    • pp.940-948
    • /
    • 2016
  • Objectives: This exploratory trial evaluated the possibility of quantitatively measuring several aspects during the "abdominal examination" of traditional Korean medicine. The main results of this study will be used to develop a new diagnostic device for abdominal examinations. Methods: Fifteen healthy volunteers were recruited for this study. Three certified Korean medical doctors assessed the existence of pressure pain, the elasticity of the abdominal muscle, and the tonus at CV12 as gold standards. Then, 2 well-trained investigators measured the pressure pain threshold (PPT), the indentation depth of a bar, and repelling force by pressing CV12. Each investigator measured the above 3 variables 2 times at 1 min intervals using a modified digital algometer. Reliability and validity tests of the 3 variables were performed. Results: There were statistically significant coefficients of intraclass correlation on the 3 variables both between and within the investigators (P<0.001). Also, PPT and repelling force showed statistically significant high sensitivity and specificity in a ROC curve. However, the indentation depth of the bar presented relatively low sensitivity. Conclusions: This new diagnostic method using a modified digital algometer could be a useful tool for quantitative measurement in "abdominal examinations". However, future rigorous clinical studies with a large population will be needed for the verification of its usefulness.

A Study in the Crimes of the Medical Practice without License - Case of Oriental Medicine's use of Ultrasounds - (무면허의료행위에 대한 형사법적 쟁점 - 한의사의 초음파기기 사용을 중심으로 -)

  • Jang, Jun Hyuk
    • The Korean Society of Law and Medicine
    • /
    • v.15 no.1
    • /
    • pp.35-57
    • /
    • 2014
  • Recently, there has been fierce argument between oriental and western doctors in the medical field. The use of medical devices has particularly come to the fore lately. Appropriate medical devices are required to diagnose and treat patients' conditions or illnesses accurately. At issue recently in medical device sector are diagnostic instruments using radiation, magnetic resonance imaging, ultrasound, IPL(Intense Pulse Light), and instruments used for tonometry. Relating to this issue, Association of Korean Oriental Medicine and The Association of Korean Medicine are sharply opposed. It is predicted that more accusations of this kind will be seen in the future. As oriental medicine contends, ultrasonic imaging itself seems to cause no harm to humans and its use may have an advantage for national health. The use of western diagnostic equipment can expand the diagnostic range of oriental doctors. However, unless new legislation is made, it is against the law for oriental doctors to use this equipment. Both law and medical science require grounds and predictability on the correctness of a decision and all of its consequences. Additionally, oriental medicine's use of ultrasounds and other medical devices should be established by standards and grounds which make same the diagnosis with repetition. Therefore, the scope of oriental medicine can be expanded following a revision of the Oriental Medicine Promotion Act and it is estimated that the state of national health will be greatly improved by the mutual respect of both sides of the health profession.

  • PDF

Organ Dose Assessment of Nuclear Medicine Practitioners Using L-Block Shielding Device for Handling Diagnostic Radioisotopes (진단용 방사성동위원소 취급 시 L-block 차폐기구 사용에 따른 핵의학 종사자의 장기 선량평가)

  • Kang, Se-Sik;Cho, Yong-In;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.49-55
    • /
    • 2017
  • In the case of nuclear medicine practitioners in medical institutions, a wide range of exposure dose to individual workers can be found, depending on the type of source, the amount of radioactivity, and the use of shielding devices in handling radioactive isotopes. In this regard, this study evaluated the organ dose on practitioners as well as the dose reduction effect of the L-block shielding device in handling the diagnostic radiation source through the simulation based on the Monte Carlo method. As a result, the distribution of organ dose was found to be higher as the position of the radiation source was closer to the handling position of a practitioner, and the effective dose distribution was different according to the ICRP tissue weight. Furthermore, the dose reduction effect according to the L-block thickness tended to decrease, which showed the exponential distribution, as the shielding thickness increased. The dose reduction effect according to each radiation source showed a low shielding effect in proportion to the emitted gamma ray energy level.

BioMEMS-EARLY DISEASE DETECTION (BioMEMS 기반의 조기 질병 진단 기술에 관한 연구)

  • Singh, Kanika;Kim, Kyung-Chun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2781-2784
    • /
    • 2007
  • Early detection of a disease is important to tackle treatment issues in a better manner. Several diagnostic techniques are in use, these days; for such purpose and tremendous research is going on to develop newer and newer methods. However, more work is required to be done to develop cheap and reliable early detection techniques. Micro-fluidic chips are also playing key role to deliver new devices for better health care. The present study focuses on a review of recent developments in the interrogation of different techniques and present state-of-the-art of microfluidic sensor for better, quick, easy, rapid, early, inexpensive and portable POCT (Point of Care testing device) device for a particular study, in this case, bone disease called osteoporosis. Some simulations of the microchip are also made to enable feasibility of the development of a blood-chip-based system. The proposed device will assist in early detection of diseases in an effective and successful manner.

  • PDF

Remote Impedance-based Loose Bolt Inspection Using a Radio-Frequency Active Sensing Node

  • Park, Seung-Hee;Yun, Chung-Bang;Inman, Daniel J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.3
    • /
    • pp.217-223
    • /
    • 2007
  • This paper introduces an active sensing node using radio-frequency (RF) telemetry. This device has brought the traditional impedance-based structural health monitoring (SHM) technique to a new paradigm. The RF active sensing node consists of a miniaturized impedance measuring device (AD5933), a microcontroller (ATmega128L), and a radio frequency (RF) transmitter (XBee). A macro-fiber composite (MFC) patch interrogates a host structure by using a self-sensing technique of the miniaturized impedance measuring device. All the process including structural interrogation, data acquisition, signal processing, and damage diagnostic is being performed at the sensor location by the microcontroller. The RF transmitter is used to communicate the current status of the host structure. The feasibility of the proposed SHM strategy is verified through an experimental study inspecting loose bolts in a bolt-jointed aluminum structure.

Development of Sugar Sensitive Drosophila Cell based ISFET Sensor for Alzheimer's Disease Diagnosis (알츠하이머 진단을 위한 당성분에 민감한 초파리 세포기반 ISFET센서개발)

  • Lim, Jeong-Ok;Yu, Joon-Boo;Kwon, Jae-Young;Byun, Hyung-Gi;Huh, Jeung-Soo;Cho, Won-Ju
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.281-285
    • /
    • 2013
  • In this study a biosensor was developed by using Drosophila cells expressing a gustatory receptor Gr5a and an ion sensitive field effect transistors (ISFETs) sensor device, which demonstrated significant compatibility with the Drosophila cells expressing Gr5a and their response to sugar. These results suggested that the newly developed cell based biosensor has a potential as a simple and easy screening device for Alzheimer's disease in the future.

Use of laser fluorescence device 'DIAGNODent$^{(R)}$' for detecting caries (레이저 우식진단기기 'DIAGNODent$^{(R)}$'의 활용)

  • Lee, Byoung-Jin
    • The Journal of the Korean dental association
    • /
    • v.49 no.8
    • /
    • pp.461-471
    • /
    • 2011
  • The detection of carious lesions is a key point to apply appropriate preventive measures or operative treatment of dental caries. A laser fluorescence device DIAGNOdent$^{(R)}$ (KaVo, Biberach, Germany) has also been shown to be of additional clinical value in the detection of initial caries. This report focus on the DIAGNOdent$^{(R)}$ for caries detection. DIAGNOdent$^{(R)}$ irradiate visible red light at a wavelength of 655 nm to elicit near-infrared fluorescence from caries lesion. This device is known as a reproducible method for caries detection, with good sensitivity and specificity especially for caries detection on occlusal and accessible smooth surfaces. DIAGNOdent$^{(R)}$ tended to be more sensitive method of detecting occlusal dentinal caries, however, showed more false-positive diagnoses than the visual inspection. So Clinician should not use the device as a clinician's primary diagnostic method and it is recommended that the device should be used in the decision-making process in relation to the diagnosis of caries as a second opinion in cases of doubt after visual inspection. The trend of modern dentistry would be a preventive approach rather than invasive treatment of the disease. This is possible only with early detection and respective preventive measures, DIAGNOdent$^{(R)}$ can help the changes.

Development of Mobile X-ray equipment for medicine (의료용 모바일 X선 장치의 개발)

  • Kim, Tae-Gon;Kim, Young-Pyo;Cheon, Min-Woo;Park, Yong-Pil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.762-763
    • /
    • 2010
  • The X-ray device used for medical treatment is classified into fixed type that is used by installing at the location with the stable power supply and mobile type that can be taken by moving the X-ray device to the location where a patient is. Mobile X-ray device which is typically used in the mobile type of X-ray can be used very usefully beyond the space restriction. However, due to its difficulty to generate high-voltage, it is mainly applied to take hand and foot shootings which only need low output power. In this study, by designing and producing the large volume of mobile X-ray device which doesn't have the limitations on diagnostic areas of the body, the operating characteristics of device according to the loading change was identified.

  • PDF