• Title/Summary/Keyword: Diagnostic Prediction

Search Result 212, Processing Time 0.028 seconds

A Study on Jaundice Computer-aided Diagnosis Algorithm using Scleral Color based Machine Learning

  • Jeong, Jin-Gyo;Lee, Myung-Suk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.12
    • /
    • pp.131-136
    • /
    • 2018
  • This paper proposes a computer-aided diagnostic algorithm in a non-invasive way. Currently, clinical diagnosis of jaundice is performed through blood sampling. Unlike the old methods, the non-invasive method will enable parents to measure newborns' jaundice by only using their mobile phones. The proposed algorithm enables high accuracy and quick diagnosis through machine learning. In here, we used the SVM model of machine learning that learned the feature extracted through image preprocessing and we used the international jaundice research data as the test data set. As a result of applying our developed algorithm, it took about 5 seconds to diagnose jaundice and it showed a 93.4% prediction accuracy. The software is real-time diagnosed and it minimizes the infant's pain by non-invasive method and parents can easily and temporarily diagnose newborns' jaundice. In the future, we aim to use the jaundice photograph of the newborn babies' data as our test data set for more accurate results.

Classification and Prediction Of A Health Status Of HIV/AIDS Patients: Artificial Neural Network Model

  • Lee, Chang W.;N.K. Kwak
    • Proceedings of the Korea Inteligent Information System Society Conference
    • /
    • 2001.01a
    • /
    • pp.473-477
    • /
    • 2001
  • Artificial neural network (ANN) is known to identify relationships even when some of the input data are very complex, ill-defined and ill-structured. One of the advantages in ANN is that it can discriminate the linearly inseparable data. This study presents an application of ANN to classify and predict the symptomatic status of HIV/AIDS patients. Even though ANN techniques have been applied to a variety of areas, this study has a substantial contribution to the HIV/AIDS care and prevention planning area. ANN model in classifying both the HIV and AIDS status of HIV/AIDS patients is developed and analyzed. The diagnostic accuracy of the ANN in classifying both the HIV status and AIDS status of HIV/AIDS status is evaluated. Several different ANN topologies are applied to AIDS Cost and Services Utilization Survey (ACSUS) datasets in order to demonstrate the model\`s capability. If ANN design models are different, it would be interesting to see what influence would have on classification of HIV/AIDS-related persons.

  • PDF

Development of an Adaptive Neuro-Fuzzy Techniques based PD-Model for the Insulation Condition Monitoring and Diagnosis

  • Kim, Y.J.;Lim, J.S.;Park, D.H.;Cho, K.B.
    • Electrical & Electronic Materials
    • /
    • v.11 no.11
    • /
    • pp.1-8
    • /
    • 1998
  • This paper presents an arificial neuro-fuzzy technique based prtial discharge (PD) pattern classifier to power system application. This may require a complicated analysis method employ -ing an experts system due to very complex progressing discharge form under exter-nal stress. After referring briefly to the developments of artificical neural network based PD measurements, the paper outlines how the introduction of new emerging technology has resulted in the design of a number of PD diagnostic systems for practical applicaton of residual lifetime prediction. The appropriate PD data base structure and selection of learning data size of PD pattern based on fractal dimentsional and 3-D PD-normalization, extraction of relevant characteristic fea-ture of PD recognition are discussed. Some practical aspects encountered with unknown stress in the neuro-fuzzy techniques based real time PD recognition are also addressed.

  • PDF

Diagnostic Significance of the Delta Neutrophil Index and Other Conventional Parameters in Neonatal Bacteremia (신생아 균혈증에서 Delta Neutrophil Index의 진단적 의의)

  • Koh, Il Doo;Jeon, Ihn Soo;Kim, Hwang Min
    • Pediatric Infection and Vaccine
    • /
    • v.24 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • Purpose: We investigated the effectiveness of the delta neutrophil index (DNI) for the prediction of neonatal bacteremia and compared it to other indices. Methods: A total of 146 pediatric patients, aged less than 31 days, admitted to the neonatal intensive care unit of Wonju Severance Christian Hospital with fever before or during hospitalization were enrolled in this study. We divided the patients into two groups based on the existence of neonatal bacteremia and performed blood culture tests on both groups. We examined white blood cell count, absolute neutrophil count, DNI, platelet count, and C-reactive protein (CRP) test. We used a receiver operating characteristic (ROC) curve to evaluate their diagnostic significance. Results: Seventy-seven patients were diagnosed with neonatal bacteremia. The mean gestational age was 38.74 weeks and the mean birth weight was 3.20 kg. The mean gestational age of the control group was 33.34 weeks and the mean birth weight was 2.20 kg. Causative organisms of bacteremia included Staphylococcus aureus (n=22), Staphylococcus epidermidis (n=18), and Streptococcus agalactiae (n=8). Both DNI and CRP were significantly associated with neonatal bacteremia after adjusting for gestational age and birth weight. The area under the ROC curve (AUC) for DNI (0.70) was higher than that for CRP (0.68). Conclusions: The DNI can be used to effectively predict neonatal bacteremia. The prediction will be more accurate if DNI is used in conjunction with other indices. In future, it will be useful to compare DNI with other indices and investigate its relationship with prognosis.

Development of Cerebral Amyloid Positivity Predicting Models Using Clinical Indicators (임상적 지표를 이용한 대뇌 아밀로이드 단백 축적 여부 예측모델 개발)

  • Chun, Young Jae;Joo, Soo Hyun
    • Korean Journal of Biological Psychiatry
    • /
    • v.27 no.2
    • /
    • pp.94-100
    • /
    • 2020
  • Objectives Amyloid β positron emission tomography (Aβ PET) is widely used as a diagnostic tool in patients who have symptoms of cognitive impairment, however, this diagnostic examination is too expensive. Thus, predicting the positivity of Aβ PET before patients undergo the examination is essential. We aimed to analyze clinical predictors of patients who underwent Aβ PET retrospectively, and to develop a predicting model of Aβ PET positivity. Methods 468 patients who underwent Aβ PET with cognitive impairment were recruited and their clinical indicators were analyzed retrospectively. We specified the primary outcome as Aβ PET positivity, and included variables such as age, sex, body mass index, diastolic blood pressure, systolic blood pressure, education, dementia family history, Mini Mental Status Examination (MMSE), Clinical Dementia Rating (CDR), Clinical Dementia Rating-Sum of Box (CDR-SB), hypertension (HTN), diabetes mellitus (DM) and presence of apolipoprotein E (ApoE) E4 as potential predictors. We developed three final models of amyloid positivity prediction for total subjects, mild cognitive impairment (MCI) and Alzheimer's disease (AD) dementia using a multivariate stepwise logistic regression analysis. Receiver operating characteristic (ROC) curve analysis was performed and the area under curve (AUC) value was calculated for the ROC curve. Results Aβ PET negative patients were 49.6% (n = 232), and Aβ PET positive patients were 50.4% (n = 236). In the final model of all subjects, older age, female sex, presence of ApoE E4 and lower MMSE are associated with Aβ PET positivity. The AUC value was 0.296. In the final model of MCI subjects (n = 244), older age and presence of ApoE E4 are associated with Aβ PET positivity. The AUC value was 0.725. In the final model of AD subjects (n = 173), lower MMSE scores, the presence of ApoE E4 and history of HTN are associated with Aβ PET positivity. The AUC value was 0.681. Conclusions The cerebral amyloid positivity model, which was based on commonly available clinical indicators, can be useful for prediction of amyloid PET positivity in MCI or AD patients.

Analysis of opposing histone modifications H3K4me3 and H3K27me3 reveals candidate diagnostic biomarkers for TNBC and gene set prediction combination

  • Park, Hyoung-Min;Kim, HuiSu;Lee, Kang-Hoon;Cho, Je-Yoel
    • BMB Reports
    • /
    • v.53 no.5
    • /
    • pp.266-271
    • /
    • 2020
  • Breast cancer encompasses a major portion of human cancers and must be carefully monitored for appropriate diagnoses and treatments. Among the many types of breast cancers, triple negative breast cancer (TNBC) has the worst prognosis and the least cases reported. To gain a better understanding and a more decisive precursor for TNBC, two major histone modifications, an activating modification H3K4me3 and a repressive modification H3K27me3, were analyzed using data from normal breast cell lines against TNBC cell lines. The combination of these two histone markers on the gene promoter regions showed a great correlation with gene expression. A list of signature genes was defined as active (highly enriched H3K4me3), including NOVA1, NAT8L, and MMP16, and repressive genes (highly enriched H3K27me3), IRX2 and ADRB2, according to the distribution of these histone modifications on the promoter regions. To further enhance the investigation, potential candidates were also compared with other types of breast cancer to identify signs specific to TNBC. RNA-seq data was implemented to confirm and verify gene regulation governed by the histone modifications. Combinations of the biomarkers based on H3K4me3 and H3K27me3 showed the diagnostic value AUC 93.28% with P-value of 1.16e-226. The results of this study suggest that histone modification analysis of opposing histone modifications may be valuable toward developing biomarkers and targets for TNBC.

Carboxylic Acids as Biomarkers of Biomphalaria alexandrina Snails Infected with Schistosoma mansoni

  • Abou Elseoud, Salwa M. F.;Fattah, Nashwa S. Abdel;El Din, Hayam M. Ezz;Abdel Al, Hala;Mossalem, Hanan;Elleboudy, Noha
    • Parasites, Hosts and Diseases
    • /
    • v.48 no.2
    • /
    • pp.127-132
    • /
    • 2010
  • Biomphalaria alexandrina snails play an indispensable role in transmission of schistosomiasis. Infection rates in field populations of snails are routinely determined by cercarial shedding neglecting prepatent snail infections, because of lack of a suitable method for diagnosis. The present study aimed at separation and quantification of oxalic, malic, acetic, pyruvic, and fumaric acids using ion-suppression reversed-phase high performance liquid chromatography (HPLC) to test the potentiality of these acids to be used as diagnostic and therapeutic biomarkers. The assay was done in both hemolymph and digestive gland-gonad complex (DGG) samples in a total of 300 B. alexandrina snails. All of the studied acids in both the hemolymph and tissue samples except for the fumaric acid in hemolymph appeared to be good diagnostic biomarkers as they provide not only a good discrimination between the infected snails from the control but also between the studied stages of infection from each other. The most sensitive discriminating acid was malic acid in hemolymph samples as it showed the highest F-ratio. Using the Z-score, malic acid was found to be a good potential therapeutic biomarker in the prepatency stage, oxalic acid and acetic acid in the stage of patency, and malic acid and acetic acid at 2 weeks after patency. Quantification of carboxylic acids, using HPLC strategy, was fast, easy, and accurate in prediction of infected and uninfected snails and possibly to detect the stage of infection. It seems also useful for detection of the most suitable acids to be used as drug targets.

Assessment of Gait as a Diagnostic Tool for Patients with Dementia (치매 진단도구로서 치매노인의 보행능력 평가에 대한 연구)

  • Lee, Han-Suk;Park, Sun-Wook
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.12 no.2
    • /
    • pp.129-136
    • /
    • 2017
  • PURPOSE: The purpose of this study was to compare the gait of elderly patients with and without dementia to investigate the possibility of an ambulation assessment test as a diagnostic tool for dementia. METHODS: A total of 96 subjects were included with 60 participants without dementia (control group) and 36 patients with dementia (dementia group). To compare the walking ability of the two groups, a 4-m walking test (4MWT) and Groningen Meander Walking Test (GMWT) were conducted. The GMWT is graded by amount of time in seconds and by number of oversteps outside the track. Mann-Whitney U test was used to compare the gait between the groups and the area under the curve (AUC) with Received Operating Characteristic (ROC) curve was analyzed. Statistical significance was considered at a p<.05, with a 95% confidence interval. RESULTS: There were statistically significant differences (p<.05) between the dementia group and the control group for the 4MWT, GMWTSEC, and GMWTSTEP scores. The AUC was .95 for 4MWT, .92 for GMWTSEC, and .96 for GMWTSTEP with the 95% confidence interval. The cut-off values of the ROC curve were 1.03m/s for 4MWT, 10.8 second for GMWTSEC, and 3.75 steps for GMSTEP. CONCLUSION: In our study, we investigated the utility of ambulatory assessment tools to predict dementia. The results of this study suggest that the 4MWT and the GMWT used in this study are appropriate assessment tools for dementia prediction.

A Study of X-ray Output for Diagnostic X-ray Equipment (진단용 X선 발생 장치의 X선 출력에 관한 연구)

  • Ko, Shin-Gwan;Ahn, Bong-Seon;Jang, Sang-Sup;Choi, Jong-Woon;Shin, Young-Soon
    • Journal of radiological science and technology
    • /
    • v.18 no.2
    • /
    • pp.61-73
    • /
    • 1995
  • For the managements of the diagnostic X-ray equipments, the authors examined the output of single phase rectification assembly, Three phase rectification assembly and serial radiographic appartus, and got the following conclusions. 1. When the tube voltages in X-ray control panels ware compared to the measured values on the kVp pulse meter, only little differences were detected in all the X-ray equipments. And most of the equipments were all well managed within the internationally permitted limits, excepting the 12.02 % error at 120 kVp in three phase rectifying assembly. 2. As for the X-ray qualities affecting the X-ray images, the serial radiographic apparatus showed excellence, while the single phase rectification assembly were somewhat inferior to the others only maining the internationally recommended limits. 3. The tube voltage ranges where the X-ray output showed excellence were $100{\sim}200\;mA$ in serial radiographic apparatus, $200{\sim}350\;mA$ in three phase rectification assembly and $350{\sim}400\;mA$ in single phase rectification assembly respectively. 4. In the repeatability test of the X-ray equipments, CVs were in the range of $0.0029{\sim}0.049$, which is within the HEW or KS standards. Consequently all the equipments are thought to be well-manage. 5. This study on characteristics and output of the X-ray equipments was accomplished within a limited short time. Long-time researches on the function managements for the X-ray equipments should be followed along with the periodical checking the output for reduction of X-ray exposures to the patients or radio-technologists, and for maintanance and prediction of trouble of the equipments.

  • PDF

Quantitative Ultrasound for Osteoporosis Screening in Postmenopausal Women (폐경 후 여성에서 골다공증의 조기검진도구로서 골초음파의 유용성)

  • Shin, Hee-Young;Jung, Eun-Kyung;Rhee, Jung-Ae;Choi, Jin-Su;Shin, Min-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.34 no.4
    • /
    • pp.408-416
    • /
    • 2001
  • Objectives : To evaluate the diagnostic value of quantitative ultrasound (QUS) in the prediction of osteoporosis as defined by dual energy x-ray absorptiometry (DEXA) in postmenopausal women. Methods : Questionnaires and height and weight measurements were used in the investigation of 176 postmenopausal women. QUS measurements were taken on the right calcaneus while bone mineral density (BMD) measurements of the lumbar spine and femoral neck were made with DEXA. The areas under the curves (AUC) of the speed of sound (SOS) for osteoporosis in the lumbar spine and femoral neck were obtained through receiver operating characteristic (ROC) analysis and evaluated. A comparison was made, for osteoporosis in the lumbar spine and femoral neck, between the AUCs of the logistic model with clinical risk factors and SOS. Results : Pearson's correlation coefficients of SOS and lumbar spine BMD, and of SOS and femoral neck BMD were 0.26 and 0.37. The AUC for the logistic model in its discrimination for lumbar spine osteoporosis was 0.764, and for SOS 0.605. The AUCs for the logistic model in its discrimination for femoral neck osteoporosis and for SOS were 0.890 and 0.892, respectively. Conclusions : These results suggest that the diagnostic value of QUS as a screening tool for osteoporosis is moderate for the femoral neck, but merely low for the lumbar spine and that the predictability provided by SOS is no better than that by the sole use of clinical risk factors in postmenopausal women.

  • PDF