• 제목/요약/키워드: Diagnostic Imaging: Radiography

검색결과 229건 처리시간 0.021초

Diagnostic reference levels in intraoral dental radiography in Korea

  • Kim, Eun-Kyung;Han, Won-Jeong;Choi, Jin-Woo;Jung, Yun-Hoa;Yoon, Suk-Ja;Lee, Jae-Seo
    • Imaging Science in Dentistry
    • /
    • 제42권4호
    • /
    • pp.237-242
    • /
    • 2012
  • Purpose: The objectives of this study were to survey the radiographic exposure parameters, to measure the patient doses for intraoral dental radiography nationwide, and thus to establish the diagnostic reference levels (DRLs) in intraoral dental X-ray examination in Korea. Materials and Methods: One hundred two intraoral dental radiographic machines from all regions of South Korea were selected for this study. Radiographic exposure parameters, size of hospital, type of image receptor system, installation duration of machine, and type of dental X-ray machine were documented. Patient entrance doses (PED) and dose-area products (DAP) were measured three times at the end of the exit cone of the X-ray unit with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for adult mandibular molar intraoral dental radiography, and corrections were made for room temperature and pressure. Measured PED and DAP were averaged and compared according to the size of hospital, type of image receptor system, installation duration, and type of dental X-ray machine. Results: The mean exposure parameters were 62.6 kVp, 7.9 mA, and 0.5 second for adult mandibular molar intraoral dental radiography. The mean patient dose was 2.11 mGy (PED) and 59.4 $mGycm^2$ (DAP) and the third quartile one 3.07 mGy (PED) and 87.4 $mGycm^2$ (DAP). Doses at university dental hospitals were lower than those at dental clinics (p<0.05). Doses of digital radiography (DR) type were lower than those of film-based type (p<0.05). Conclusion: We recommend 3.1 mGy (PED), 87.4 $mGycm^2$ (DAP) as the DRLs in adult mandibular molar intraoral dental radiography in Korea.

Image enhancement of digital periapical radiographs according to diagnostic tasks

  • Choi, Jin-Woo;Han, Won-Jeong;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • 제44권1호
    • /
    • pp.31-35
    • /
    • 2014
  • Purpose: This study was performed to investigate the effect of image enhancement of periapical radiographs according to the diagnostic task. Materials and Methods: Eighty digital intraoral radiographs were obtained from patients and classified into four groups according to the diagnostic tasks of dental caries, periodontal diseases, periapical lesions, and endodontic files. All images were enhanced differently by using five processing techniques. Three radiologists blindly compared the subjective image quality of the original images and the processed images using a 5-point scale. Results: There were significant differences between the image quality of the processed images and that of the original images (P< 0.01) in all the diagnostic task groups. Processing techniques showed significantly different efficacy according to the diagnostic task (P< 0.01). Conclusion: Image enhancement affects the image quality differently depending on the diagnostic task. And the use of optimal parameters is important for each diagnostic task.

임상에서 촬영되는 파노라마 방사선사진의 재현성 조사 (Reproducibility of panoramic radiography in patients)

  • 나경수
    • Imaging Science in Dentistry
    • /
    • 제35권3호
    • /
    • pp.115-119
    • /
    • 2005
  • Purpose : To evaluate the magnification error percentage in repeatedly taken panoramic radiographs of same patient and machine. Materials and Methods : 92 panoramic radiographs from 46 patients were traced and 30 horizontal and vertical measurements were made with digital sliding caliper. The results were compared with paired t-test. Results : There was no statistically significant difference between the two measurements. The overall difference as percentage error was $6.19\pm5.60\%$. The largest error as $14.61\pm12.44\%$ was found at condylar height 1, and smallest as $1.86\pm1.61\%$ at mandibular height. Overall vertical error excluding condylar height 1 was $3.76\pm3.97\%$, and the horizontal error $6.88\pm5.92\%$. Conclusion . Repeatedly taken panoramic radiographs of the same patient and machine was reliable since there was no significant percentage error difference but the percentage error ranged from $1.86\pm1.61\%\;to\;14.61\pm12.44\%$ indicating the error depends on the measuring site.

  • PDF

Determination and classification of intraoral phosphor storage plate artifacts and errors

  • Deniz, Yesim;Kaya, Seher
    • Imaging Science in Dentistry
    • /
    • 제49권3호
    • /
    • pp.219-228
    • /
    • 2019
  • Purpose: The aim of this study was to determine the reasons and solutions for intraoral phosphor storage plate (PSP) image artifacts and errors, and to develop an appropriate classification of the artifacts. Materials and Methods: This study involved the retrospective examination of 5,000 intraoral images that had been obtained using a phosphor plate system. Image artifacts were examined on the radiographs and classified according to possible causative factors. Results: Artifacts were observed in 1,822 of the 5,000 images. After examination of the images, the errors were divided into 6 groups based on their causes, as follows: images with operator errors, superposition of undesirable structures, ambient light errors, plate artifacts (physical deformations and contamination), scanner artifacts, and software artifacts. The groups were then re-examined and divided into 45 subheadings. Conclusion: Identification of image artifacts can help to improve the quality of the radiographic image and control the radiation dose. Knowledge of the basic physics and technology of PSP systems could aid to reduce the need for repeated radiography.

우리나라의 두부 엑스선검사에서의 환자선량 권고량 (A Study for Establishment of Diagnostic Reference Level of Patient Dose in Skull Radiography)

  • 이정은;정진백;이현구;임천일;손혜경;진현미;김병우;양현규;김혁주;김동섭;이광용
    • Journal of Radiation Protection and Research
    • /
    • 제35권3호
    • /
    • pp.111-116
    • /
    • 2010
  • 진단을 위한 엑스선검사는 의료분야에서 전리방사선을 가장 많이 사용하고 있으며 인공 방사선피폭중 가장 높은 비율을 차지하고 있다. 우리나라에서도 진단 엑스선검사에 의한 의료피폭은 전체 방사선 피폭 중 17.4%를 차지하고 있으며 인공방사선피폭 중에서는 92%를 차지하고 있다. 두부진단을 위한 엑스선 촬영 횟수도 2007년의 경우에는 111,567건으로서 2004년 이후 매년 3% 정도의 증가 추세를 나타내고 있다. 따라서 환자선량 권고량을 국내의료기관 실정에 맞도록 설정하여 두부촬영시 환자가 받는 방사선량을 줄이고 환자의 방사선 방어를 최적화 하는 것이 필요하다. 본 논문에서는 전국 114개 의료기관에서의 두부 촬영시 피폭되는 방사선량을 인체팬텀과 유리선량계를 사용하여 측정하고 환자선량권고량(DRL, Diagnostic Reference Level)을 확립하였다. 이 결과에 따라 두부 후전면 촬영에서의 환자선량 권고량은 2.23 mGy이며, 이는 세계보건기구, 국제원자력기구 등 국제기구가 권고하는 선량 5 mGy 보다 낮았으며, 두부 측면찰영에서의 환자선량 권고량인 1.87 mGy는 국제기구가 권고하는 선량 3mG 보다 낮았다.

Evaluation of Radiographic Positioning Techniques Used in Local Hospitals after Teleradiology Consultation

  • Sojin Kim;Miju Oh;Yooyoung Lee;Minju Lee;Jiyoung Ban;Uhjin Kim;Jiwoon Park;Jaepung Han;Dongwoo Chang
    • 한국임상수의학회지
    • /
    • 제39권6호
    • /
    • pp.326-333
    • /
    • 2022
  • The purpose of this study was to evaluate the radiographic positioning techniques used in local animal hospitals, identify the most common positioning problem, and determine whether there were changes after teleradiology consultations. From September 2016 to April 2021, 15 local animal hospitals that requested radiographic interpretation more than 10 times and for more than six cases of thoracic radiographs were selected. Six sets of two-views of (lateral and ventrodorsal [VD] or dorsoventral [DV] views) digital thoracic radiographs from six dogs per hospital were evaluated in four categories. For the lateral view, radiographic technique scores used in ten local animal hospitals improved, one remained the same, and four became worse. For the VD/DV view, the score for eleven hospitals improved and worsened for four. The most common problem was rotation (57/90) for the lateral view, followed by an inappropriate field of view (59/90), and incorrect beam center (71/90). For the VD/DV view, an inappropriate field of view (54/90) was the most common problem, followed by asymmetry (63/90), and incorrect beam center (73/90). Every factor, except rotation in the lateral view, improved after obtaining technical consultation; however, the degrees of improvement were not remarkable. There was no significant correlation between the number of requests and the degree of improvement. According to the results, the radiographic technique used in local animal hospitals was improved by technical advice on teleradiology. These changes make it possible to provide accurate diagnoses of the requested images. There are some limitations regarding the indicators of evaluation and the number of cases; therefore, further studies that use detailed indicators in large cohort group are needed. In addition, an effective method of teaching should be developed to improve radiographic techniques in local animal hospitals.

워터스, 파노라마 방사선사진과 Scanora$\textregistered$ 방사선사진의 상악동 점막비후 진단 결과의 비교 (A COMPARISON OF SCANORA$\textregistered$ RADIOGRAPHY WITH WATERS' AND PANORAMIC VIEWS FOR THE DETECTION OF MUCOSAL THICKENING OF MAXILLARY SINUS)

  • 윤숙자;정현대;강병철
    • 치과방사선
    • /
    • 제25권2호
    • /
    • pp.389-398
    • /
    • 1995
  • The purpose of this study was to compare the diagnostic performance of Waters' and panoramic view; maxillary sinus posteroanterior and lateral scanography of Scanora/sup (R)/ for mucosal thickening of maxillary sinus as well as to identify the utility of Scanora/sup (R)/ for the detection of maxillary sinus disease. The assessment was done at 66 maxillary sinuses in 45 patients and the results were as follows ; 1. Estimation of presence or absence of mucosal thickening. The sensitivity, specificity, and positive and negative predictive value of maxillary sinus posteroanterior and lateral scanography were 0.865, 0.860, 0.921, and 0.805 respectively and slightly higher than those of Waters' and panoramic views, which were 0.832, 0.835, 0.903, and 0.728 respectively. However, paired t-test showed no significant differences in the diagnostic performance of the two pairs of imaging modalities. 2. Estimation of the types of mucosal thickening. The diagnostic accuracy for type I, II, III was 75.3% on Waters' and panoramic view; 77.9% on maxillary sinus posteroanterior and lateral scanography. It was higher on the latter ,but showed no significant differences from that on the former. 3. Reliability of interpretation. In itraobserver and interobserver agreement, both overall rates of agreement and kappa-value were slightly higher on maxillary sinus posteroanterior and lateral scanography than on Waters' and panoramic views. There was no significant differences between the two pairs of imaging modalities. These results suggested that scanogram is a useful diagnostic radiography as well as Waters' and panoramic views for detection of maxillary sinusitis.

  • PDF

The reliability of tablet computers in depicting maxillofacial radiographic landmarks

  • Tadinada, Aditya;Mahdian, Mina;Sheth, Sonam;Chandhoke, Taranpreet K;Gopalakrishna, Aadarsh;Potluri, Anitha;Yadav, Sumit
    • Imaging Science in Dentistry
    • /
    • 제45권3호
    • /
    • pp.175-180
    • /
    • 2015
  • Purpose: This study was performed to evaluate the reliability of the identification of anatomical landmarks in panoramic and lateral cephalometric radiographs on a standard medical grade picture archiving communication system (PACS) monitor and a tablet computer (iPad 5). Materials and Methods: A total of 1000 radiographs, including 500 panoramic and 500 lateral cephalometric radiographs, were retrieved from the de-identified dataset of the archive of the Section of Oral and Maxillofacial Radiology of the University Of Connecticut School Of Dental Medicine. Major radiographic anatomical landmarks were independently reviewed by two examiners on both displays. The examiners initially reviewed ten panoramic and ten lateral cephalometric radiographs using each imaging system, in order to verify interoperator agreement in landmark identification. The images were scored on a four-point scale reflecting the diagnostic image quality and exposure level of the images. Results: Statistical analysis showed no significant difference between the two displays regarding the visibility and clarity of the landmarks in either the panoramic or cephalometric radiographs. Conclusion: Tablet computers can reliably show anatomical landmarks in panoramic and lateral cephalometric radiographs.

개에서 발생한 소화기계 이물에 대한 회고분석 - 143 증례 (Retrospective Study of 143 Dogs with Alimentary Foreign Bodies)

  • 최지혜;계서연;김현욱
    • 한국임상수의학회지
    • /
    • 제32권1호
    • /
    • pp.49-55
    • /
    • 2015
  • This study was retrospectively investigated the clinical features, diagnostic imaging, treatment, and prognosis of foreign bodies according to alimentary site and type of foreign body, in 143 dogs. Among 28 breeds, Maltese, Shih Tzu, and terriers including the Yorkshire terrier were presented with high prevalence. Bone was the most commonly identified (33%) foreign body regardless of alimentary site. Approximately 76% of foreign bodies were in the stomach and small intestine. All esophageal foreign bodies were diagnosed on survey radiography, with the most common location being the caudal thoracic esophageal segment. Further diagnostic examinations including ultrasonography or contrast studies were additionally performed to detect radiolucent foreign bodies and perforation or leakage in the stomach and intestine. However, most seeds could be identified based on the characteristic features such as hyperdense thin double lines and inner gas on survey radiography. In conclusion, complications such as peritonitis and intestinal perforation were mainly observed in cases with seeds and linear foreign bodies. Especially, fabric foreign bodies could be induce peritonitis and re-perforation with high prevalence after surgical correction.

Common positioning errors in panoramic radiography: A review

  • Rondon, Rafael Henrique Nunes;Pereira, Yamba Carla Lara;do Nascimento, Glauce Crivelaro
    • Imaging Science in Dentistry
    • /
    • 제44권1호
    • /
    • pp.1-6
    • /
    • 2014
  • Professionals performing radiographic examinations are responsible for maintaining optimal image quality for accurate diagnoses. These professionals must competently execute techniques such as film manipulation and processing to minimize patient exposure to radiation. Improper performance by the professional and/or patient may result in a radiographic image of unsatisfactory quality that can also lead to a misdiagnosis and the development of an inadequate treatment plan. Currently, the most commonly performed extraoral examination is panoramic radiography. The invention of panoramic radiography has resulted in improvements in image quality with decreased exposure to radiation and at a low cost. However, this technique requires careful, accurate positioning of the patient's teeth and surrounding maxillofacial bone structure within the focal trough. Therefore, we reviewed the literature for the most common types of positioning errors in panoramic radiography to suggest the correct techniques. We would also discuss how to determine if the most common positioning errors occurred in panoramic radiography, such as in the positioning of the patient's head, tongue, chin, or body.