• 제목/요약/키워드: Diagnostic Accuracy

검색결과 1,063건 처리시간 0.024초

요로 종양의 세포병리 (Cytopathology of Urinary Tract Neoplasms)

  • 홍은경
    • 대한세포병리학회지
    • /
    • 제17권1호
    • /
    • pp.1-17
    • /
    • 2006
  • Urine cytology is the most useful technique for detecting either primary or recurrent neoplasms in the urinary tract. Although urine cytology is the traditional method of detecting these neoplasms, its diagnostic accuracy has been underevaluated because of low sensitivity. The cytologic interpretation of urinary samples is not an easy task, even with some expertise in this area, for many reasons. In low-grade urothelial carcinoma, no reliable or reproducible diagnostic cytologic criteria can be provided because of the lack of obvious cytologic features of malignancy, which is one of the main factors lowering its diagnostic accuracy. Many diagnostic markers have been developed recently to enhance its diagnostic yield, but the results have not been satisfactory. However, urine cytology plays a role in detecting high-grade urothelial carcinoma or its precursor lesions. It still shows higher specificity than any of the newly developed urine markers. Understanding the nature of urine samples and the nature of neoplasms of the urinary tract, recognizing their cytologic features fully, and using cytologic findings under appropriate conditions in conjunction with a detailed clinical history would make urine cytology a very valuable diagnostic tool.

Consistency check algorithm for validation and re-diagnosis to improve the accuracy of abnormality diagnosis in nuclear power plants

  • Kim, Geunhee;Kim, Jae Min;Shin, Ji Hyeon;Lee, Seung Jun
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3620-3630
    • /
    • 2022
  • The diagnosis of abnormalities in a nuclear power plant is essential to maintain power plant safety. When an abnormal event occurs, the operator diagnoses the event and selects the appropriate abnormal operating procedures and sub-procedures to implement the necessary measures. To support this, abnormality diagnosis systems using data-driven methods such as artificial neural networks and convolutional neural networks have been developed. However, data-driven models cannot always guarantee an accurate diagnosis because they cannot simulate all possible abnormal events. Therefore, abnormality diagnosis systems should be able to detect their own potential misdiagnosis. This paper proposes a rulebased diagnostic validation algorithm using a previously developed two-stage diagnosis model in abnormal situations. We analyzed the diagnostic results of the sub-procedure stage when the first diagnostic results were inaccurate and derived a rule to filter the inconsistent sub-procedure diagnostic results, which may be inaccurate diagnoses. In a case study, two abnormality diagnosis models were built using gated recurrent units and long short-term memory cells, and consistency checks on the diagnostic results from both models were performed to detect any inconsistencies. Based on this, a re-diagnosis was performed to select the label of the second-best value in the first diagnosis, after which the diagnosis accuracy increased. That is, the model proposed in this study made it possible to detect diagnostic failures by the developed consistency check of the sub-procedure diagnostic results. The consistency check process has the advantage that the operator can review the results and increase the diagnosis success rate by performing additional re-diagnoses. The developed model is expected to have increased applicability as an operator support system in terms of selecting the appropriate AOPs and sub-procedures with re-diagnosis, thereby further increasing abnormal event diagnostic accuracy.

Kodak Insight 구내필름의 치아우식증 진단능에 대한 연구 (Diagnostic accuracy of Insight intraoral film on dental caries)

  • 윤영남;이상래;이병도
    • Imaging Science in Dentistry
    • /
    • 제34권1호
    • /
    • pp.19-23
    • /
    • 2004
  • Purpose: To compare the diagnostic accuracy of Kodak Insight film with other intra-oral films in the detection of dental caries. Materials and Methods : Periapical radiographs of 99 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were made on Kodak Ultra speed, Ektaspeed, Agfa Ektaspeed and Kodak Insight films and automatically processed. Six dentists examined the presence of dental caries using a five-point confidence rating scale and compared the diagnostic accuracy by ROC (Receiver Operating Characteristic) analysis and ANOVA test. Results: The sensitivity of Kodak Ultra speed, Ektaspeed, Agfa Ektaspeed and Insight film were 0.84, 0.77, 0.75 and 0.79 respectively. The specificity of Kodak Ultra speed, Ektaspeed, Agfa Ektaspeed and Insight film were 0.97. 0.95. 0.96 and 0.94 respectively. The mean ROC areas (Az) of Kodak Ultra speed, Ektaspeed, Agfa Ektaspeed and Insight film were 0.917, 0.910, 0.894, 0.909 respectively. There was no significant differences between Az of Insight film and other films (p = 0.178). Conclusion: Theses results suggested that Kodak Insight film have the comparative diagnostic accuracy of dental caries with Ultraspeed and Ektaspeed films.

  • PDF

한국형 중풍변증 표준 III을 이용한 변증진단 판별모형 (Discriminant Modeling for Pattern Identification Using the Korean Standard PI for Stroke-III)

  • 강병갑;고미미;이주아;박태용;박용규
    • 동의생리병리학회지
    • /
    • 제25권6호
    • /
    • pp.1113-1118
    • /
    • 2011
  • In this paper, when a physician make a diagnosis of the pattern identification (PI) in Korean stroke patients, the development methods of the PI classification function is considered by diagnostic questionnaire of the PI for stroke patients. Clinical data collected from 1,502 stroke patients who was identically diagnosed for the PI subtypes diagnosed by two physicians with more than 3 years experiences in 13 oriental medical hospitals. In order to develop the classification function into PI using Korean Stroke Syndrome Differentiation Standard was consist of the 44 items (Fire heat(19), Qi deficiency(11), Yin deficiency(7), Dampness-phlegm(7)). Using the 44 items, we took diagnostic and prediction accuracy rate through of discriminant model. The overall diagnostic and prediction accuracy rate of the PI subtypes for discriminant model was 74.37%, 70.88% respectively.

IBS-2000보정기기를 이용한 체형측정방법에 따른 사상체질 진단정확률 비교연구 (Comparative Study of Sasang Constitutions Diagnostic Accuracy Rate on Measurement Method of Body Shape by IBS-2000 Compensator)

  • 설유경;이의주;김규곤;김종원
    • 사상체질의학회지
    • /
    • 제19권1호
    • /
    • pp.78-89
    • /
    • 2007
  • 1. Objectives This is the comparative study with hand-operated measurement method & Automatic measurement method, in order to convert the automatic measurement method. 2. Methods We measured the body of patients(hand-operated width 5 places and hand-operated circumference 8 places, Automatic width 5 places) and analyzed the anthropometric data dividing into sex, age, BMI. 1057 patients's data are used in the analysis. 3. Results and Conclusions 1) 5th Width variable which was measured during lying down was not a sasang constitutional difference. 2) Diagnostic accuracy rate of the body measurement by Width which was measured during lying down and Width which IBS standing was 40-60%. 3) Diagnostic accuracy rate of Automatic & hand-operated measuring was not a big difference.

  • PDF

Diagnostic Accuracy of Lactate Dehydrogenase/Adenosine Deaminase Ratio in Differentiating Tuberculous and Parapneumonic Effusions: A Systematic Review

  • Larry Ellee Nyanti;Muhammad Aklil Abd Rahim;Nai-Chien Huan
    • Tuberculosis and Respiratory Diseases
    • /
    • 제87권1호
    • /
    • pp.91-99
    • /
    • 2024
  • Background: Tuberculous pleural effusion (TPE) and parapneumonic effusion (PPE) are often difficult to differentiate owing to the overlapping clinical features. Observational studies demonstrate that the ratio of lactate dehydrogenase to adenosine deaminase (LDH/ADA) is lower in TPE compared to PPE, but integrated analysis is warranted. Methods: We conducted a systematic review to evaluate the diagnostic accuracy of the LDH/ADA ratio in differentiating TPE and PPE. We explored the PubMed and Scopus databases for studies evaluating the LDH/ADA ratio in differentiating TPE and PPE. Results: From a yield of 110 studies, five were included for systematic review. The cutoff value for the LDH/ADA ratio in TPE ranged from <14.2 to <25. The studies demonstrated high heterogeneity, precluding meta-analysis. Quality Assessment of Diagnostic Accuracy Studies Tool 2 assessment revealed a high risk of bias in terms of patient selection and index test. Conclusion: LDH/ADA ratio is a potentially useful parameter to differentiate between TPE and PPE. Based on the limited data, we recommend an LDH/ADA ratio cutoff value of <15 in differentiating TPE and PPE. However, more rigorous studies are needed to further validate this recommendation.

Reliability of Stool Antigen Tests: Investigation of the Diagnostic Value of a New Immunochromatographic Helicobacter pylori Approach in Dyspeptic Patients

  • Korkmaz, Huseyin;Findik, Duygu;Ugurluoglu, Ceyha;Terzi, Yuksel
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권2호
    • /
    • pp.657-660
    • /
    • 2015
  • Background: A diagnosis of H. pylori infection can be made by invasive or non-invasive methods. Several noninvasive diagnostic tests based on the detection of H. pylori stool antigen (HpSA) have been developed. The Genx H. pylori stool antigen card test is a new rapid, non-invasive test that is based on monoclonal immunochromatographic assay. The aim of this study was to determine its sensitivity, specificity, and diagnostic accuracy for diagnosing H. pylori infection in adult patients. Materials and Methods: A total of 162 patients were included in the study. A gastric biopsy was collected for histopathology and rapid urease testing. Stool specimens for HpSA testing were also collected. Patients were considered H. pylori positive if two invasive tests (histological and rapid urease tests) were positive. Results: Using the reference test, 50.6% of the samples were positive for H. pylori infection. The Genx H. pylori antigen test was positive in 19.7% of patients. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of the Genx H. pylori antigen test were 51.6%, 96.0%, 88.8%, 76.1%, and 79.0%, respectively. Conclusions: The Genx H. pylori stool antigen card test is a new non-invasive method that is fast and simple to perform but provides less reliable results.

The effects of noise reduction, sharpening, enhancement, and image magnification on diagnostic accuracy of a photostimulable phosphor system in the detection of non-cavitated approximal dental caries

  • Kajan, Zahra Dalili;Davalloo, Reza Tayefeh;Tavangar, Mayam;Valizade, Fatemeh
    • Imaging Science in Dentistry
    • /
    • 제45권2호
    • /
    • pp.81-87
    • /
    • 2015
  • Purpose: Contrast, sharpness, enhancement, and density can be changed in digital systems. The important question is to what extent the changes in these variables affect the accuracy of caries detection. Materials and Methods: Forty eight extracted human posterior teeth with healthy or proximal caries surfaces were imaged using a photostimulable phosphor (PSP) sensor. All original images were processed using a six-step method: (1) applying "Sharpening 2" and "Noise Reduction" processing options to the original images; (2) applying the "Magnification 1:3" option to the image obtained in the first step; (3) enhancing the original images by using the "Diagonal/"option; (4) reviewing the changes brought about by the third step of image processing and then, applying "Magnification 1:3"; (5) applying "Sharpening UM" to the original images; and (6) analyzing the changes brought about by the fifth step of image processing, and finally, applying "Magnification 1:3." Three observers evaluated the images. The tooth sections were evaluated histologically as the gold standard. The diagnostic accuracy of the observers was compared using a chi-squared test. Results: The accuracy levels irrespective of the image processing method ranged from weak (18.8%) to intermediate (54.2%), but the highest accuracy was achieved at the sixth image processing step. The overall diagnostic accuracy level showed a statistically significant difference (p=0.0001). Conclusion: This study shows that the application of "Sharpening UM" along with the "Magnification 1:3" processing option improved the diagnostic accuracy and the observer agreement more effectively than the other processing procedures.

Clinicopathological Significance and Diagnostic Accuracy of c-MET Expression by Immunohistochemistry in Gastric Cancer: A Meta-Analysis

  • Pyo, Jung-Soo;Kang, Guhyun;Cho, Hyunjin
    • Journal of Gastric Cancer
    • /
    • 제16권3호
    • /
    • pp.141-151
    • /
    • 2016
  • Purpose: The aim of the present study was to elucidate the clinicopathological significance and diagnostic accuracy of immunohistochemistry (IHC) for determining the mesenchymal epidermal transition (c-MET) expression in patients with gastric cancer (GC). Materials and Methods: The present meta-analysis investigated the correlation between c-MET expression as determined by IHC and the clinicopathological parameters in 8,395 GC patients from 37 studies that satisfied the eligibility criteria. In addition, a concordance analysis was performed between c-MET expression as determined by IHC and c-MET amplification, and the diagnostic test accuracy was reviewed. Results: The estimated rate of c-MET overexpression was 0.403 (95% confidence interval [CI], 0.327~0.484) and it was significantly correlated with male patients, poor differentiation, lymph node metastasis, higher TNM stage, and human epidermal growth factor receptor 2 (HER2) positivity in IHC analysis. There was a significant correlation between c-MET expression and worse overall survival rate (hazard ratio, 1.588; 95% CI, 1.266~1.992). The concordance rates between c-MET expression and c-MET amplification were 0.967 (95% CI, 0.916~0.987) and 0.270 (95% CI, 0.173~0.395) for cases with non-overexpressed and overexpressed c-MET, respectively. In the diagnostic test accuracy review, the pooled sensitivity and specificity were 0.56 (95% CI, 0.50~0.63) and 0.79 (95% CI, 0.77~0.81), respectively. Conclusions: The c-MET overexpression as determined by IHC was significantly correlated with aggressive tumor behavior and positive IHC status for HER2 in patients with GC. In addition, the c-MET expression status could be useful in the screening of c-MET amplification in patients with GC.

Diagnostic accuracy of artificially induced vertical root fractures: a comparison of direct digital periapical images with conventional periapical images

  • Lee Ji-Un;Kwon Ki-Jeong;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • 제34권4호
    • /
    • pp.185-190
    • /
    • 2004
  • Purpose: To compare the diagnostic accuracy for the detection of root fractures in CMOS-based digital periapical images with conventional film-based periapical images. Materials and Methods: Sixty extracted single-root human teeth with closed apices were prepared endodontically and divided into two groups; artificially induced vertical root fracture group and control group. All radiographs were obtained using the paralleling technique. The radiographs were examined by 4 observers three times within a 4 week interval. Receiver operating characteristic (ROC) analysis was carried out using data obtained from four observers. Intra- and inter-examiner agreements were computed using kappa analysis. Results: The area under the ROC curve (Az) was used as an indicator of the diagnostic accuracy of the imaging system. Az values were as follows: direct-digital images; 0.93, film-based images; 0.92, and inverted digital images; 0.91. There was no significant difference between imaging modalities (P<0.05). The kappa value of inter-observer agreement was 0.42 (range: 0.28-0.60) and intra-observer agreement was 0.57 (range: 0.44-0.75). Conclusion : There is no statistical difference in diagnostic accuracy for the detection of vertical root fractures between digital periapical images and conventional periapical images. The results indicate that the CMOS sensor is a good image detector for the evaluation of vertical root fractures.

  • PDF