Fine needle aspiration cytology (FNAC) has been known as a very sensitive and effective method for preoperative diagnosis. We studied cases preoperatively diagnosed by FNAC and confirmed by the histopathologic examination to define the effectiveness of FNAC. A total of 567 cases including breast, thyroid gland, lymph node, and soft tissue confirmed histologically after FNAC were enrolled, among 2,844 FNAC cases from January 1996 to March 2000. Overall sensitivity and specificity of FNAC were 93% and 100%, respectively. Sensitivity and specificity of FNAC by sites or organs were 91% and 100% in breast, 100% and 100% in thyroid, 97% and 100% in lymph node, and 71% and 100% in soft tissue, respectively. Nine cases showed diagnostic discrepancy; eight cases of sampling error and one case of interpretation error. Five cases, diagnosed as fibrocystic change at FNAC but invasive ductal carcinoma after the histopathologic examination, were categorized as sampling error due to the presence of diffuse fibrosis or deep seated location. One case of breast, diagnosed descriptively as atypical ductal and stromal cells suggesting invasive ductal carcinoma at FNAC but malignant phyllodes tumor histologically, was categorized as interpretation error. Other cases of sampling errors were two cases of soft tissue, a case of lymph node, and a case of salivary gland.
Kwon, H.;Kim, K.;Kim, J.M.;Lee, Y.H.;Kim, T.E.;Lim, H.K.;Park, Y.K.;Ko, Y.G.;Chung, N.
Progress in Superconductivity
/
v.8
no.1
/
pp.40-45
/
2006
In emergency rooms, patients with acute chest pain should be diagnosed as quickly as possible with higher diagnostic accuracy for an appropriate therapy to the patients with acute coronary syndrome or for avoiding unnecessary hospital admissions. At present, electrocardiography(ECG) and biochemical markers are generally used to detect myocardial infarction and coronary angiography is used as a gold standard to reveal the degree of narrowing of coronary artery. Magnetocardiography(MCG) has been proposed as a novel and non-invasive diagnostic tool fur the detection of cardiac electrical abnormality associated with myocardial ischemia. In this study, we examined whether the MCG can be used fur the detection of coronary artery disease(CAD) in patients, who were admitted to the emergency room with acute chest pain. MCG was recorded from 36 patients admitted to the emergency room with suspected acute coronary syndrome. The MCG recordings were obtained using a 64-channel SQUID MCG system in a magnetically shielded room. In result, presence of CAD could be found with a sensitivity of 88.2 % in patients with acute chest pain without 57 elevation in ECG, demonstrating a possible use in the emergency room to screen CAD patients.
Purpose : This study was performed to compare the diagnostic ability of conventional intraoral radiographs with that of digital subtraction image and to assess the quantifying ability of digital subtraction image for simulated apical root resorption Materials and Methods : Conventional intraoral radiographs and digital images of ten sound maxillary central incisors and those with simulated apical root resorption were taken with varying horizontal and vertical angulations of the x-ray beam. The diagnostic accuracy to detect the lesion was evaluated on conventional intraoral radiographs and digital subtraction images by ROC analysis. The amount of simulated apical root resorption was also estimated on the reconstruction images by Emago/sup (R)/ and compared with actual amount of tooth loss using paired t-test. Results: The diagnostic accuracy of conventional intraoral radiographs to detect the apical root resorption was low (ROC area = 0.6446), and the sensitivity and the specificity of digital subtraction images were 100%, respectively. The calculated amounts of apical root resorption showed no statistically significant difference with the actual amounts of the lesion (p>0.05). Conclusion: Digital subtraction radiography is powerful tool to detect the small apical root resorption, and quantitative analysis of small amounts of the lesion can be evaluated by digital subtraction radiography.
Purpose: Detecting laryngeal cartilages (triticeous and thyroid cartilages) on panoramic radiographs is important because they may be confused with carotid artery calcifications in the bifurcation region, which are a risk factor for stroke. This study assessed the efficiency of panoramic radiography in the diagnosis of calcified laryngeal cartilages using cone-beam computed tomography (CBCT) as the reference standard. Materials and Methods: A total of 312 regions(142 bilateral, 10 left, 18 right) in 170 patients(140 males, 30 females) were examined. Panoramic radiographs were examined by an oral and maxillofacial radiologist with 11 years of experience. CBCT scans were reviewed by 2 other oral and maxillofacial radiologists. The kappa coefficient(${\kappa}$) was calculated to determine the level of intra-observer agreement and to determine the level of agreement between the 2 methods. Diagnostic indicators(sensitivity, specificity, accuracy, and false positive and false negative rates) were also calculated. P values <.05 were considered to indicate statistical significance. Results: Eighty-two images were re-examined to determine the intra-observer agreement level, and the kappa coefficient was calculated as 0.709 (P<.05). Statistically significant and acceptable agreement was found between the panoramic and CBCT images (${\kappa}=0.684$ and P<.05). The sensitivity, specificity, diagnostic accuracy rate, the false positive rate, and the false negative rate of the panoramic radiographs were 85.4%, 83.5%, 84.6%, 16.5%, and 14.6%, respectively. Conclusion: In most cases, calcified laryngeal cartilages could be diagnosed on panoramic radiographs. However, due to variation in the calcifications, diagnosis may be difficult.
Recently ultrasound and scintigraphic study are most useful modality for diagnosis of scrotal diseases. They are able to determine the nature, anatomic extent of the lesion, and possible to differential diagnosis of the scrotal lesion. The ultrasound and scintigraphic findings were analyses in 59 patients of confirmed scrotal disease at Seoul Red Cross Hospital from June 1986 to Aug. 1989. The results were as follows. 1) Most patients were below the 30 years old age (69.4%), and most prevalent age was $11\sim30$ Yrs. in trauma, $31\sim40$ Yrs. in inflammation, and $51\sim60$ Yrs. in mass lesion of scrotum. 2) The diagnostic accuracy of scrotal disease was 94.9% in ultrasound and 72% in scintigraphic study. The ultrasound study showed high accuracy in all kind of scrotat disease, but scintigraphy showed only high detection rate in inflammatory disease. 3) Scrotal ultrasound is first choice of study for the diagnosis of scrotal lesion, and useful determine the cystic or solid lesion and anatomic extent of disease. However it can't be differentiate the acute epididymitis with acute testicular torsion. 4) Scrotal scintigraphy is useful study for the diagnosis of acute painful scrotal disease, and showed specific findings in acute epididymitis and acute torsion for differential diagnosis. 5) In consideration of age, history and clinical findings of patient, appropriate study will be chosen firstly in ultrasound and scintigraphy, and combined all of findings of these studies will be helpful for the accurate diagnosis and adequate treatment of scrotal disease.
Background: Although identifying cases in large administrative databases may aid future research studies, previous reports demonstrated that the use of the International Classification of Diseases, Tenth Revision (ICD-10) code alone for diagnosis leads to disease misclassification. Purpose: We aimed to assess the value of the ICD-10 diagnostic code for identifying potential children with biliary atresia. Methods: Patients aged <18 years assigned the ICD-10 code of biliary atresia (Q44.2) between January 1996 and December 2016 at a quaternary care teaching hospital were identified. We also reviewed patients with other diagnoses of code-defined cirrhosis to identify more potential cases of biliary atresia. A proposed diagnostic algorithm was used to define ICD-10 code accuracy, sensitivity, and specificity. Results: We reviewed the medical records of 155 patients with ICD-10 code Q44.2 and 69 patients with other codes for biliary cirrhosis (K74.4, K74.5, K74.6). The accuracy for identifying definite/probable/possible biliary atresia cases was 80%, while the sensitivity was 88% (95% confidence interval [CI], 82%-93%). Three independent predictors were associated with algorithm-defined definite/probable/possible cases of biliary atresia: ICD-10 code Q44.2 (odds ratio [OR], 2.90; 95% CI, 1.09-7.71), history of pale stool (OR, 2.78; 95% CI, 1.18-6.60), and a presumed diagnosis of biliary atresia prior to referral to our hospital (OR, 17.49; 95% CI, 7.01-43.64). A significant interaction was noted between ICD-10 code Q44.2 and a history of pale stool (P<0.05). The area under the curve was 0.87 (95% CI, 0.84-0.89). Conclusion: ICD-10 code Q44.2 has an acceptable value for diagnosing biliary atresia. Incorporating clinical data improves the case identification. The use of this proposed diagnostic algorithm to examine data from administrative databases may facilitate appropriate health care allocation and aid future research investigations.
Objective: This study aimed to evaluate the diagnostic value of combining the quantitative parameters of shear wave elastography (SWE) and superb microvascular imaging (SMI) to breast ultrasound (US) to differentiate between benign and malignant breast masses. Materials and Methods: A total of 200 pathologically confirmed breast lesions in 192 patients were retrospectively reviewed using breast US with B-mode imaging, SWE, and SMI. Breast masses were assessed based on the breast imaging reporting and data system (BI-RADS) and quantitative parameters using the maximum elasticity (Emax) and ratio (Eratio) in SWE and the vascular index in SMI (SMIVI). The area under the receiver operating characteristic curve (AUC) value, sensitivity, specificity, accuracy, negative predictive value, and positive predictive value of B-mode alone versus the combination of B-mode US with SWE or SMI of both parameters in differentiating between benign and malignant breast masses was compared, respectively. Hypothetical performances of selective downgrading of BI-RADS category 4a (set 1) and both upgrading of category 3 and downgrading of category 4a (set 2) were calculated. Results: Emax with a cutoff value of 86.45 kPa had the highest AUC value compared to Eratio of 3.57 or SMIVI of 3.35%. In set 1, the combination of B-mode with Emax or SMIVI had a significantly higher AUC value (0.829 and 0.778, respectively) than B-mode alone (0.719) (p < 0.001 and p = 0.047, respectively). B-mode US with the addition of Emax, Eratio, and SMIVI had the best diagnostic performance of AUC value (0.849). The accuracy and specificity increased significantly from 68.0% to 84.0% (p < 0.001) and from 46.1% to 79.1% (p < 0.001), respectively, and the sensitivity decreased from 97.6% to 90.6% without statistical loss (p = 0.199). Conclusion: Combining all quantitative values of SWE and SMI with B-mode US improved the diagnostic performance in differentiating between benign and malignant breast lesions.
Matheus Barros-Costa;Eduarda Helena Leandro Nascimento;Iago Filipe Correia-Dantas;Matheus L. Oliveira;Deborah Queiroz Freitas
Imaging Science in Dentistry
/
v.54
no.1
/
pp.49-56
/
2024
Purpose: This study evaluated the impact of artifacts generated by metal crowns on the detection of proximal caries lesions in teeth at various distances using cone-beam computed tomography (CBCT). Additionally, the diagnostic impacts of tube current and metal artifact reduction (MAR) were investigated. Materials and Methods: Thirty teeth were arranged within 10 phantoms, each containing 1 first premolar, 1 second premolar, and 1 second molar. A sound first molar (for the control group) or a tooth with a metal crown was placed. Of the 60 proximal surfaces evaluated, 15 were sound and 45 exhibited enamel caries. CBCT scans were acquired using an OP300 Maxio unit (Instrumentarium, Tuusula, Finland), while varying the tube current (4, 8, or 12.5 mA) and enabling or disabling MAR. Five observers assessed mesial and distal surfaces using a 5-point scale. Multi-way analysis of variance was employed for data comparison, with P<0.05 indicating statistical significance. Results: The area under the curve (AUC) varied from 0.40 to 0.60 (sensitivity: 0.28-0.45, specificity: 0.44-0.80). The diagnostic accuracy was not significantly affected by the presence of a metal crown, milliamperage, or MAR(P>0.05). However, the overall AUC and specificity were significantly lower for surfaces near a crown (P<0.05). Conclusion: CBCT-based caries detection was not influenced by the presence of a metal crown, variations in milliamperage, or MAR activation. However, the diagnostic accuracy was low and was further diminished for surfaces near a crown. Consequently, CBCT is not recommended for the detection of incipient caries lesions.
Purpose: Several studies report that detection of thyroglobulin (Tg) in fine-needle aspiration (FNA) biopsy washout fluid from lymph nodes identifies recurrences or metastases of differentiated papillary thyroid cancer (DPTC) in the neck with higher sensitivity and specificity than fine-needle aspiration cytology (FNAC). We evaluate the diagnostic efficacy and usefulness of Tg measurement in FNA washout fluid (FNA-Tg) and compare with FNAC. Materials and Methods: Forty-eight FNA samples of 37 patients who undergone ultrasonography to detect cervical lymph node metastasis of DPTC, were included for this study. Lymph node metastasis was confirmed by histopathologic examination or long-term imaging follow-up. Sensitivity, specificity and accuracy of FNA-Tg and FNAC were calculated. In 34 patients, we evaluated diagnostic accuracy of FNA-Tg according to the presence or absence of Tg antibody. Results: Sensitivity, specificity and accuracy of FNAC were 75.0%, 97.2% and 91.7%, respectively, and those of FNA-Tg were 100%, 88.9% and 91.7%, respectively. The presence of Tg antibody was not relevant to the diagnostic accuracy of FNA-Tg. Conclusion: FNA-Tg is a as accurate as FNAC with higher sensitivity. FNA-Tg and FNAC are complement techniques for diagnosing lymph node metastasis of DTPC.
Background: This study was conducted to investigate whether apparent diffusion coefficient (ADC) measurements by dividing the liver into left and right hepatic lobes may be utilized to improve the accuracy of differential diagnosis of benign and malignant focal liver lesions. Materials and Methods: A total of 269 consecutive patients with 429 focal liver lesions were examined by 3-T magnetic resonance imaging that included diffusion-weighted imaging. For 58 patients with focal liver lesions of the same etiology in left and right hepatic lobes, ADCs of normal liver parenchyma and focal liver lesions were calculated and compared using the paired t-test. For all 269 patients, ADC cutoffs for focal liver lesions and diagnostic accuracy in the left hepatic lobe, right hepatic lobe and whole liver were evaluated by receiver operating characteristic curve analysis. Results: For the group of 58 patients, mean ADCs of normal liver parenchyma and focal liver lesions in the left hepatic lobe were significantly higher than those in the right hepatic lobe. For differentiating malignant lesions from benign lesions in all patients, the sensitivity and specificity were 92.6% and 92.0% in the left hepatic lobe, 94.4% and 94.4% in the right hepatic lobe, and 90.4% and 94.7% in the whole liver, respectively. The area under the curve of the right hepatic lobe, but not the left hepatic lobe, was higher than that of the whole liver. Conclusions: ADCs of normal liver parenchyma and focal liver lesions in the left hepatic lobe were significantly higher than those in the right hepatic lobe. Optimal ADC cutoff for focal liver lesions in the right hepatic lobe, but not in the left hepatic lobe, had higher diagnostic accuracy compared with that in the whole liver.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.