Browse > Article
http://dx.doi.org/10.7314/APJCP.2014.15.15.6155

Diffusion-Weighted Imaging for the Left Hepatic Lobe has Higher Diagnostic Accuracy for Malignant Focal Liver Lesions  

Han, Xue (Department of Radiology, Provincial Hospital, Shandong University)
Dong, Yin (Department of Radiology, Provincial Hospital, Shandong University)
Xiu, Jian-Jun (Department of Radiology, Provincial Hospital, Shandong University)
Zhang, Jie (Department of Radiology, Provincial Hospital, Shandong University)
Huang, Zhao-Qin (Department of Radiology, Provincial Hospital, Shandong University)
Cai, Shi-Feng (Department of Radiology, Provincial Hospital, Shandong University)
Yuan, Xian-Shun (Department of Radiology, Provincial Hospital, Shandong University)
Liu, Qing-Wei (Department of Radiology, Provincial Hospital, Shandong University)
Publication Information
Asian Pacific Journal of Cancer Prevention / v.15, no.15, 2014 , pp. 6155-6160 More about this Journal
Abstract
Background: This study was conducted to investigate whether apparent diffusion coefficient (ADC) measurements by dividing the liver into left and right hepatic lobes may be utilized to improve the accuracy of differential diagnosis of benign and malignant focal liver lesions. Materials and Methods: A total of 269 consecutive patients with 429 focal liver lesions were examined by 3-T magnetic resonance imaging that included diffusion-weighted imaging. For 58 patients with focal liver lesions of the same etiology in left and right hepatic lobes, ADCs of normal liver parenchyma and focal liver lesions were calculated and compared using the paired t-test. For all 269 patients, ADC cutoffs for focal liver lesions and diagnostic accuracy in the left hepatic lobe, right hepatic lobe and whole liver were evaluated by receiver operating characteristic curve analysis. Results: For the group of 58 patients, mean ADCs of normal liver parenchyma and focal liver lesions in the left hepatic lobe were significantly higher than those in the right hepatic lobe. For differentiating malignant lesions from benign lesions in all patients, the sensitivity and specificity were 92.6% and 92.0% in the left hepatic lobe, 94.4% and 94.4% in the right hepatic lobe, and 90.4% and 94.7% in the whole liver, respectively. The area under the curve of the right hepatic lobe, but not the left hepatic lobe, was higher than that of the whole liver. Conclusions: ADCs of normal liver parenchyma and focal liver lesions in the left hepatic lobe were significantly higher than those in the right hepatic lobe. Optimal ADC cutoff for focal liver lesions in the right hepatic lobe, but not in the left hepatic lobe, had higher diagnostic accuracy compared with that in the whole liver.
Keywords
Diffusion-weighted imaging; apparent diffusion coefficient; focal liver lesion; left and right hepatic lobes;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Bartolozzi C, Cioni D, Donati F, et al (2001). Focal liver lesions: MR imaging-pathologic correlation. Eur Radiol, 11, 1374-88.   DOI
2 Bruegel M, Holzapfel K, Gaa J, et al (2008). Characterization of focal liver lesions by ADC measurements using a respiratory triggered diffusion-weighted single-shot echo-planar MR imaging technique. Eur Radiol, 18, 477-85.   DOI   ScienceOn
3 de Bazelaire CM, Duhamel GD, Rofsky NM, et al (2004). MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: preliminary results. Radiology, 230, 652-9.   DOI   ScienceOn
4 Dietrich O, Biffar A, Baur-Melnyk A, et al (2010). Technical aspects of MR diffusion imaging of the body. Eur Radiol, 76, 314-22.   DOI
5 Erturk SM, Ichikawa T, Sano K, et al (2008). Diffusion-weighted magnetic resonance imaging for characterization of focal liver masses: impact of parallel imaging (SENSE) and b value. J Comput Assist Tomogr, 32, 865-71.   DOI
6 Gourtsoyianni S, Papanikolaou N, Yarmenitis S, et al (2008). Respiratory gated diffusion-weighted imaging of the liver: value of apparent diffusion coefficient measurements in the differentiation between most commonly encountered benign and malignant focal liver lesions. Eur Radiol, 18, 486-92.   DOI   ScienceOn
7 Griswold MA, Jakob PM, Heidemann RM, et al (2002). Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med, 47, 1202-10.   DOI   ScienceOn
8 Horton KM, Bluemke DA, Hruban RH, et al (1999). CT and MR imaging of benign hepatic and biliary tumors. Radiographics, 19, 431-51.   DOI
9 Ichikawa T, Haradome H, Hachiya J, et al (1998). Diffusionweighted MR imaging with a single-shot echoplanar sequence: detection and characterization of focal hepatic lesions. AJR Am J Roentgenol, 170, 397-402.   DOI   ScienceOn
10 Kandpal H, Sharma R, Madhusudhan KS, Kapoor KS (2009). Respiratory -triggered versus breath-h old diffusion-weight ed MRI of live r lesions: comparison of image quality and apparent diffusion coefficient values. AJR Am J Roentgenol, 192, 915-22.   DOI   ScienceOn
11 Kilickesmez O, Yirik G, Bayramoglu S, et al (2008). Non-breathhold high b-value diffusion- weighted MRI with parallel imaging technique: apparent diffusion coefficient determination in normal abdominal organs. Diagn Interv Radiol, 14, 83-7.
12 Kim T, Murakami T, Takahashi S, et al (1999). Diffusion-weighted single-shot echo planar MR imaging for liver disease. AJR Am J Roentgenol, 173, 393-8.   DOI   ScienceOn
13 Koh DM, Takahara T, Imai Y, et al (2007). Practical aspects of assessing tumors using clinical diffusion-weighted imaging in the body. Magn Reson Med Sci, 6, 211-24.   DOI   ScienceOn
14 Kwee TC, Takahara T, Niwa T, et al (2009). Influence of cardiac motion on diffusion-weighted magnetic resonance imaging of the liver. MAGMA, 22, 319-25.   DOI
15 Murtz P, Flacke S, Traber F, et al (2002). Abdomen: diffusionweighted MR Imaging with pulse-triggered single-shot sequences. Radiology, 224, 258-64.   DOI   ScienceOn
16 Naganawa S, Kawai H, Fukatsu H, et al (2005). Diffusion-weighted imaging of the liver: technical challenges and prospects for the future. Magn Reson MedSci, 31, 175-86.
17 Nasu K, Ku roki Y, Sekiguchi R, et al (2006). Measurement of the apparent diffusion coefficient in the liver: is it a reliable index for hepatic disease diagnosis?. Radiat Med, 24, 438-44.   DOI
18 Parikh T, Drew SJ, Lee VS, et al (2008). Focal liver lesion detection and characterization with diffusion-weighted MR imaging: comparison with standard breath-hold T2-weighted imaging. Radiology, 246, 812-22.   DOI   ScienceOn
19 Nasu K, Kuroki Y, Nawano S, et al (2006). Hepatic metastases: diffusion-weighted sensitivity-encoding versus SPIO-enhanced MR Imaging. Radiology, 239, 122-30.   DOI   ScienceOn
20 Naiki T, Okamura T, Nagata D, et al (2011). Preoperative prediction of neurovascular bundle involvement of localized prostate cancer by combined T2 and diffusion-weighted imaging of magnetic resonance imaging, number of positive biopsy cores, and Gleason score. Asian Pac J Cancer Prev, 12, 909-13.
21 Schmid-Tannwald C, Jiang Y, Dahi F, et al (2013). Diffusion-Weighted MR Imaging of Focal Liver Lesions in the Left and Right Lobes: Is There a Difference in ADC Values?. Acad Radiol, 20, 440-5.   DOI
22 Taouli B (2012). Diffusion-weighted MR imaging for liver lesion characterization: a critical look. Radiology, 262, 378-80.   DOI   ScienceOn
23 Taouli B, Koh DM (2010). Diffusion-weighted MR imaging of the liver. Radiology, 254, 47-66.   DOI   ScienceOn
24 Taouli B, Vilgrain V, Dumont E, et al (2003). Evaluation of liver diffusion isotropy and characterization of focal hepatic lesions with two single-shot echo-planar MR imaging sequences: prospective study in 66 patients. Radiology, 226, 71-8.   DOI   ScienceOn
25 Vossen JA, Buijs M, Liapi E, et al (2008). Receiver operating characteristic analysis of diffusion-weighted magnetic resonance imaging in differentiating hepatic hemangioma from other hypervascular liver lesions. J Comput Assist Tomogr, 32, 750-6.   DOI   ScienceOn
26 Sandberg A, Parikh T, Johnson G, et al (2006). Feasibility of a respiratory-triggered SSEPI diffusion-weighted sequence for liver imaging using navigator echo technique: comparison with breath-hold diffusion-weighted sequence. Proc Intl Soc Mag Reson Med, 14, 400.
27 Wu QW, Yan RF, Li Q, et al (2013). Magnetic resonance image manifestations of the atypical meningioma. Asian Pac J Cancer Prev, 14, 6337-40.   과학기술학회마을   DOI
28 Xia D, Jing J, Shen H, et al (2010). Value of diffusion-weighted magnetic resonance images for discrimination of focal benign and malignant hepatic lesions: a meta-analysis. J Magn Reson Imaging, 32, 130-7.   DOI
29 Zhang JL, Sigmund EE, Chandarana H, et al (2010). Variability of renal apparent diffusion coefficients: limitations of the monoexponential model for diffusion quantification. Radiology, 254, 783-92.   DOI
30 Dong Y, Liu Q (2012). Differentiation of Malignant From Benign Pheochromocytomas With Diffusion-Weighted and Dynamic Contrast-Enhanced Magnetic Resonance at 3.0 T. J Comput Assist Tomogr, 36, 361-6.   DOI