• Title/Summary/Keyword: Diagnosis Method

Search Result 5,001, Processing Time 0.031 seconds

IGBT Open-Circuit Fault Diagnosis for 3-Phase 4-Wire 3-Level Active Power Filters based on Voltage Error Correlation

  • Wang, Ke;Tang, Yi;Zhang, Xiao;Wang, Yang;Zhang, Chuan-Jin;Zhang, Hui
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1950-1963
    • /
    • 2016
  • A novel open-circuit fault diagnosis method for 3-phase 4-wire 3-level active power filters based on voltage error correlation is proposed in this paper. This method is based on observing the output pole voltage error of the active power filter through two kinds of algorithms. One algorithm is a voltage error analytical algorithm, which derives four output voltage error analytic expressions through the pulse state, current value and dc bus voltage, respectively, assuming that all of the IGBTs of a certain phase come to an OC fault. The other algorithm is a current circuit equation algorithm, which calculates the real-time output voltage error through basic circuit theory. A correlation is introduced to measure the similarity of the output voltage errors between the two algorithms, and OC faults are located by the maximum of the correlations. A FPGA has been chosen to implement the proposed method due to its fast prototyping. Simulation and experimental results are presented to show the performance of the proposed OC fault diagnosis method.

A Rapid, Simple Determination of Sulfur-containing Compounds and Methylmalonic Acid on Plasma using GC-MS-SIM for the Diagnosis of Homocysteinemia (혈장 중 황함유 화합물과 메틸말론산의 신속 간편한 분석법 개발; GC-MS-SIM을 이용한 호모시스테인혈증의 진단)

  • Yoon, Hye-Ran;Thapa, Maheshwor
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.15 no.3
    • /
    • pp.138-146
    • /
    • 2015
  • Purpose: If early diagnosis is not made, patients with metabolic disorders as homocystinemia rapidly progress to physical defect or mental retardation resulted in storage of the toxic material into the brain. Therefore, it is necessary to develop an analytical method for a rapid screening and/or correct confirmation diagnosis. Methods: The standard solution of sulfur amino acids spiked plasma was subjected to protein precipitation with methanol, and then consecutively derivatized with trimethylsilyl (TMS) and trifluoroacyl (TFA) and determined by GC-MS. The formation of TMS derivative of the hydroxyl and TFA derivative of amino functional group was performed by BSTFA and MBTFA, respectively. Selective ion monitoring (SIM) mode was used for quantification with selected specific ions. Results: A calibration curve on standard spiked pooled plasma showed a linear relationship with correlation coefficient of 0.9936-0.9992 for all compounds over the range of 0.1-300 ng. The precision and accuracy were within S.D. of 1-15% and RSD of 1-15% for intra-day assay at 2 ng/mL, 15 ng/mL and 30 ng/mL. LOD and LOQ was 0.4 ng/mL and 4 ng/mL respectively. Conclusion: A rapid analytical method was developed to quantify sulfur amino acids and methyl malonic acid, after two-step derivatization procedure with good sensitivity and specificity on human plasma. Advantages of a new method are simplicity and rapidity. The method could be useful for routine analysis, diagnosis of homocysteinemia.

A Basic Study on the Estimation of Discharge Current Waveform and the Insulation Diagnosis by the Measurement of Electromagnetic Environment (전자환경 측정에 의한 방전전류 파형추정과 절연진단의 기초 연구)

  • Park, Gwang-Seo;Kim, Gi-Chae;Kim, Lee-Guk;Park, Won-Ju;Lee, Gwang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.10
    • /
    • pp.492-499
    • /
    • 2002
  • This paper presents the method for an estimation of discharge current waveform in short gap discharge by radiated electromagnetic fields. The method of current waveform estimation is to use the one antenna method (single field method) with a measured electric or magnetic field at given field point by a time domain antenna. In order to verify the availability of the estimation theory, the discharge current waveform estimation was performed by one antenna methods using the measured electric fields of Wilson & Ma and compared with experiments. In addition diagnosis technique for power equipments is able to prevent from large accidents by finding signs of tile accidents before they happen. From the results of the estimation of discharge current, we have a possibility for the application of insulation diagnosis technique for power equipments using S$F_6$ gas. From this point of view, this paper simulated discharge progress and partial discharge by using needle-plan electrodes system in S$F_6$, studied the distribution of frequency spectrum of the radiated electromagnetic waves using a biconical antenna and a spectrum analyzer. From the experimental results of this study, according to the consideration of the mutual relation between frequency spectrum of the radiated electromagnetic waves and discharge progress, it was confirmed that detecting Partial discharge and estimating discharge progress in S$F_6$ could be Possible.

Bearing Fault Diagnosis by Condition Monitoring Method (Condition Monitoring기법에 의한 베어링의 이상진단)

  • 이정철;오재응;염성하;권오관
    • Tribology and Lubricants
    • /
    • v.3 no.1
    • /
    • pp.52-60
    • /
    • 1987
  • Many kinds of condition monitoring technique as the preventive maintenance technique have been studied, so this study has investigated the possibility of chbcking the trend in the fault diagnosis of ball bearing, one of the important elements of rotating machine, by applying the cepstral analysis method. And computer simulation is conducted in order to identify obviously the physical meaning of cepstral analysis. It is identified that cepstral analysis is effective method to distinguish between the basic and reflected wave by computer simulation, and we know that it is possible to apply the cepstral analysis to the arbitrary elements of rotating machine which are different in fundamental frequency. It is verified that cepstral analysis method is more effective than the other conventional method in bearing fault diganosis.

Development of Software For Machinery Diagnostics by Adaptive Noise Cancelling Method (1St: Cepstrum Analysis)

  • Lee, Jung-Chul;Oh, Jae-Eung;Yum, Sung-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10a
    • /
    • pp.836-841
    • /
    • 1987
  • Many kinds of conditioning monitoring technique have been studied, so this study has investigated the possibility of checking the trend in the fault diagnosis of ball bearing, one of the elements of rotating machine, by applying the cepstral analysis method using the adaptive noise cancelling (ANC) method. And computer simulation is conducted in oder to identify obviously the physical meaning of ANC. The optimal adaptation gain in adaptive filter is estimated, the performance of ANC according to the change of the signal to noise ratio and convergence of LMS algorithm is considered by simulation. It is verified that cepstral analysis using ANC method is more effective than the conventional cepstral analysis method in bearing fault diagnosis.

  • PDF

The Suggestion of the clinical application of Sasang Constitutional Diagnosis (사상체질 진단의 객관화를 위한 제언)

  • Park, Hye-Sun;Kim, Hyung-Soon;Kim, Kyung-Yo;Lee, Si-Woo
    • Journal of Sasang Constitutional Medicine
    • /
    • v.13 no.2
    • /
    • pp.138-143
    • /
    • 2001
  • 1. Background Among the clinical application of Sasang Constitutional diagnostic methods, a morphologic study of face is recognized by the Ministry of Health and Welfare as a legitimate Hanbang diagnostic method. But there are some indirect different view about this method. We should criticize this method for the better. 2. Method We criticize the current morphologic study of face by its literature basis, its measurement and its result, compared with ${\ulcorner}$Dongyisoosebowon${\lrcorner}$ and other related literatures. 3. Conclusions We suggest thar the current morphologic study of face is not proper for the clinical application of Sasang Constitutional diagnostic method in the point of the lack of literature basis and the intervention of the examiner's subjectivities.

  • PDF

The fundamental principles of pulse feeling(脈診) of "Sanghanlon(傷寒論)" ("상한론(傷寒論)" 맥진(脈診)의 원리)

  • Jeong, Chang-Hyun;Jang, Woo-Chang
    • Journal of Korean Medical classics
    • /
    • v.20 no.1
    • /
    • pp.137-149
    • /
    • 2007
  • Diagnostic method by taking pulse is generally accepted as a clinical diagnosis of today. Theoretical foundation of the method was laid by "Hwangjenaegyeong" and "Nangyeong". Since then, it was quoted by "Sanghallon" and systematically applied to diagnoses by making a diagnosis in the light of pulse condition and symptoms observed so that the original form of the method was shaped thereby. And therefore, theoretical significance of diagnostic method by taking pulse was drawn in this paper to define the theory of pulse feeling. Furthermore, this paper is corroborative of that the purpose of diagnostic method by taking pulse is to diagnose pyo-lee and jang-bu; wind-cold-warmth-heat; and deficiency and excess of gi and blood as well as substantially prove it with the texts of "Sanghallon".

  • PDF

A New Scan Chain Fault Simulation for Scan Chain Diagnosis

  • Chun, Sung-Hoon;Kim, Tae-Jin;Park, Eun-Sei;Kang, Sung-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.4
    • /
    • pp.221-228
    • /
    • 2007
  • In this paper, we propose a new symbolic simulation for scan chain diagnosis to solve the diagnosis resolution problem. The proposed scan chain fault simulation, called the SF-simulation, is able to analyze the effects caused by faulty scan cells in good scan chains. A new scan chain fault simulation is performed with a modified logic ATPG pattern. In this simulation, we consider the effect of errors caused by scan shifting in the faulty scan chain. Therefore, for scan chain diagnosis, we use the faulty information in good scan chains which are not contaminated by the faults while unloading scan out responses. The SF-simulation can tighten the size of the candidate list and achieve a high diagnosis resolution by analyzing fault effects of good scan chains, which are ignored by most previous works. Experimental results demonstrate the effectiveness of the proposed method.

A Case Study on Diagnosis and Checking for Machine-Tools with an OAC (개방형 컨트롤러를 갖는 공작기계에 적합한 진단 및 신호점검사례)

  • 김동훈;송준엽;김경돈;김찬봉;김선호;고광식
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.292-297
    • /
    • 2004
  • The conventional computerized numerical controller (CNC) of machine tools has been increasingly replaced by a PC-based open architecture CNC (OAC) which is independent of the CNC vendor. The OAC and machine tools with OAC led the convenient environment where it is possible to implement user-defined application programs efficiently within CNC. Tis paper proposes a method of operational fault cause diagnosis which is based on the status of programmable logic controller (PLC) in machine tools with OAC. The operational fault is defined as a disability state occurring during normal operation of machine tools. The faults are occupied by over 70% of all faults and are also unpredictable as most of them occur without any warning. Two diagnosis models, the switching function (SF) and the step switching function (SSF), are propose in order to diagnose the fault cause quickly and exactly. The cause of an occurring fault is logically diagnosed through a fault diagnosis system (FDS) using the diagnosis models. A suitable interface environment between CNC and develope application modules is constructed in order to implement the diagnostic functions in the CNC domain. The diagnosed results were displayed on a CNC monitor for machine operators and provided to a remote site through a web browser. The result of his research could be a model of the fault cause diagnosis and the remote monitoring for machine tools with OAC.

  • PDF

Pregnancy Diagnosis in Sows by Using an On-Farm Blood Progesterone Test

  • Wu, L.S.;Guo, I.C.;Lin, J.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.10 no.6
    • /
    • pp.603-608
    • /
    • 1997
  • To improve animal production, a simple and accurate pregnancy diagnosis plays a very important role. Therefore, the purpose of this study was to develop an on-farm blood progesterone enzyme immunoassay (EIA) system for monitoring the early pregnancy in sows. Star tubes coated with mouse monoclonal anti-progesterone antibody were used for this proposed EIA system which was tested in field trials. The results could be obtained within 30 minutes either by spectrophotometry or the naked eye. Heparinized fresh blood samples collected from the ear vein of sows 17-22 days after breeding (day 0) were tested qualitatively to diagnose sows as pregnant or non-pregnant with high ( > 3 ng/ml) or low ($${{\leq_-}}3ng/ml$$) progesterone in the blood. To provided a double check data, plasma progesterone levels were also measured quantitatively by the same EIA system with some modification. Total agreement of diagnosis by the on-farm EIA kit and by farrowing or abortion from 128 tested sows was found to be 92.2% accuracy (93.1% on pregnant diagnosis and 83.3% on non-pregnant diagnosis). It was concluded that the on-farm EIA blood progesterone test is a very useful method for monitoring the early pregnancy status of sows.