• Title/Summary/Keyword: Diagnosis Method

Search Result 5,001, Processing Time 0.032 seconds

Performance comparison of shear walls with openings designed using elastic stress and genetic evolutionary structural optimization methods

  • Zhang, Hu Z.;Liu, Xia;Yi, Wei J.;Deng, Yao H.
    • Structural Engineering and Mechanics
    • /
    • v.65 no.3
    • /
    • pp.303-314
    • /
    • 2018
  • Shear walls are a typical member under a complex stress state and have complicated mechanical properties and failure modes. The separated-elements model Genetic Evolutionary Structural Optimization (GESO), which is a combination of an elastic-plastic stress method and an optimization method, has been introduced in the literature for designing such members. Although the separated-elements model GESO method is well recognized due to its stability, feasibility, and economy, its adequacy has not been experimentally verified. This paper seeks to validate the adequacy of the separated-elements model GESO method against experimental data and demonstrate its feasibility and advantages over the traditional elastic stress method. Two types of reinforced concrete shear wall specimens, which had the location of an opening in the middle bottom and the center region, respectively, were utilized for this study. For each type, two specimens were designed using the separated-elements model GESO method and elastic stress method, respectively. All specimens were subjected to a constant vertical load and an incremental lateral load until failure. Test results indicated that the ultimate bearing capacity, failure modes, and main crack types of the shear walls designed using the two methods were similar, but the ductility indexes including the stiffness degradation, deformability, reinforcement yielding, and crack development of the specimens designed using the separated-elements model GESO method were superior to those using the elastic stress method. Additionally, the shear walls designed using the separated-elements model GESO method, had a reinforcement layout which could closely resist the actual critical stress, and thus a reduced amount of steel bars were required for such shear walls.

A Study on the Acupuncture Methods of Joseon Dynasty Using Five Viscera Diagnosis (오장변증(五臟辨證)을 활용한 조선(朝鮮) 침법(鍼法) 연구(硏究))

  • Oh, Jun-Ho;Kim, Nam-Il
    • Korean Journal of Oriental Medicine
    • /
    • v.16 no.2
    • /
    • pp.1-31
    • /
    • 2010
  • Objective : The objective of this study is to verify the characteristics of acupuncture methods of Joseon Dynasty by looking into the relationship between five viscera diagnosis and acupuncture methods. Material & Method : In the process, I've reviewed the relationship between meridian/exterior and viscera/bowels, along with a thorough comparison of the academic tendency in acupuncture of Ming-China, Qing-China and Joseon. Result & Conclusion : The two fields of meridian and exterior, and viscera and bowels had been theoretically merged, and based upon that, foundation methods applying the five viscera diagnosis were designed. Joseon acupuncture exceeded the existing concept of viscera which simply related itself to the exterior meridian and exterior by integrating the concepts from the visceral manifestation theory. With this, large proportions of medicine related to the visceral manifestation theory were invited into acupuncture, expanding therapeutic boundaries for acupuncture treatment. A historical review on medical texts starts from the Hyangyakjipseongbang("鄕藥集成方") which familiarized the public with mainstream acupuncture knowledge up until the Song dynasty, followed by Uibangyuchwi("醫方類聚"), which sparked up interest on the acupuncture methods based on viscera and bowels. Donguibogam("東醫寶鑑") organized the medical theories up until then, building a foundation upon which viscera/bowel-based acupuncture was able to develop further. In Chimgugyeongheombang("鍼灸經驗方"), viscera/bowel-based acupuncture methods started to blossom, integrating the meridian and exterior theory with the viscera manifestation theory, which in turn provided various methods through five viscera diagnosis. In the Saamdoin acupuncture method(舍岩道人鍼法), diagnostic criteria moved on to the five viscera diagnosis, and new methods resulting from the inter-complimentary and inter-prohibiting relationships between the five phases were introduced, opening a new world of acupuncture.

The Polymerase Chain Reaction in Diagnosis of Small B-Cell Non-Hodgkin Lymphomas

  • Antoro, Ester Lianawati;Dwianingsih, Ery Kus;Indrawati, Indrawati;Triningsih, FX Ediati;Harijadi, Harijadi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.2
    • /
    • pp.491-495
    • /
    • 2016
  • Background: Small B-cell non-Hodgkins lymphoma (NHL) is difficult to be distinguished from non-neoplastic reactive processes using conventional haematoxylin-eosin (HE) staining due to different interpretations among pathologists with diagnosis based on morphologic features. Ancillary examinations such as immunohistochemical (IHC) staining are essential. However, negative or doubtful results are still sometimes obtained due to unsatisfactory tissue processing or IHC technique. The polymerase chain reaction (PCR) as a molecular diagnostic technique is very sensitive and specific. Clonality detection of heavy chain immunoglobulin (IgH) gene rearrangement has been widely used to establish diagnosis of B-cell NHL. Aims: To elaborate interobserver variation in small B-cell NHL diagnosis based on morphologic features only and to confirm sensitivity and specificity of the PCR technique as an ancillary method. Materials and Methods: A toptal of 28 samples of small B cell NHL and suspicious lymphoma were interpreted by 3 pathologists in Sardjito General Hospital based on their morphology only. The reliability of assessment and the coefficient of interobserver agreement were calculated by Fleiss kappa statistics. Interpretation results were confirmed with IHC staining (CD20, CD3, Bcl2). PCR was performed to analyze the clonality of IgH gene rearrangement. Results: Interobserver agreement in morphologic evalution of small B cell NHL and chronic lymphadenitis revealed kappa coefficient 0.69 included in the substantial agreement category. The cases were divided into 3 groups based on morphology and IHC results; lymphoma, reactive process and undetermined group. PCR analysis showed 90% sensitivity and 60% specificity. Conclusions: The present study revealed a substantial agreement among pathologists in small B-cell NHL diagnosis. For difficult cases, PCR is useful as complementary method to morphologic and IHC examinations to establish definitive diagnosis.

Fault Diagnosis of 3 Phase Induction Motor Drive System Using Clustering (클러스터링 기법을 이용한 3상 유도전동기 구동시스템의 고장진단)

  • Park, Jang-Hwan;Kim, Sung-Suk;Lee, Dae-Jong;Chun, Myung-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.70-77
    • /
    • 2004
  • In many industrial applications, an unexpected fault of induction motor drive systems can cause serious troubles such as downtime of the overall system heavy loss, and etc. As one of methods to solve such problems, this paper investigates the fault diagnosis for open-switch damages in a voltage-fed PWM inverter for induction motor drive. For the feature extraction of a fault we transform the current signals to the d-q axis and calculate mean current vectors. And then, for diagnosis of different fault patterns, we propose a clustering based diagnosis algorithm The proposed diagnostic technique is a modified ANFIS(Adaptive Neuro-Fuzzy Inference System) which uses a clustering method on the premise of general ANFIS's. Therefore, it has a small calculation and good performance. Finally, we implement the method for the diagnosis module of the inverter with MATLAB and show its usefulness.

Oriental Medicine-based Health Pre-Diagnosis System using Fuzzy Decision Tree (퍼지 의사 결정 트리를 이용한 한의학 기반의 건강 사전 진단 시스템)

  • Kim, Kwang Baek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.11
    • /
    • pp.1519-1524
    • /
    • 2021
  • In this paper, we propose a method that uses fuzzy decision tree based health pre-diagnosis system of oriental medicine. The proposed fuzzy decision tree based health pre-diagnosis system uses the data from the past which has been pre-trained to get the boundary values based on entropy then, when the user inputs the symptoms, the top 5 diseases that causes those symptoms are extracted. With the extracted top 5 diseases, the system provides information on those diseases with the cause and how to treat them with folk remedies. The database of the diseases and their symptoms is established with the information based on the various books that the oriental doctor recommended then reviewed by the oriental doctor for confirmation. By utilizing the data from the past to train the symptoms of the diseases, the proposed oriental medicine-based health pre-diagnosis system method could provide more accurate diagnosis results faster.

The Study of Accident Cases Verification and Construction of It's Cause Diagnosis System of Power Cable Accident (케이블 사고 자가원인 진단시스템 구축 및 사고사례 검증에 관한 연구)

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Sun-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.9
    • /
    • pp.91-97
    • /
    • 2009
  • We have constructed the it's cause diagnosis system of power cable by Failure Mode Effect Analysis(FMEA) method because we have to cause analysis when the cable accident happened. This system was composed of data input of accident condition, presentation of the shape through pictograph and accident probability by FMEA method. According to each selection, the accident cause comments are showed by the accident occurrence possibility. Also, the verification of the it's diagnosis system through the cause analysis of the cable accident cases, the system agreed well with results that analyzed actual state.

Stator winding faults diagnosis system of induction motor using LabVIEW (LabVIEW를 이용한 유도전동기 고정자 권선 고장진단시스템)

  • Song, Myung-Hyun;Park, Kyu-Nam;Lee, Tae-Hun;Han, Dong-Gi;Park, Kyung-Han
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2658-2660
    • /
    • 2005
  • This paper presents a stator winding fault diagnosis technique of induction motor on the PC - based virtual instrumentation system designed using the graphical programming language LabVIEW. This method collects the 3-phase current signals using the current probe amplifier and PXI/DAQ system then the preprocessing removes the noise using LPF, after then this method transforms the stator current to Park's vector and obtains the each Park's Vector pattern and detects stator winding fault by comparing the obtained faulted pattern with the healthy pattern. This proposed LabVIEW based diagnosis system is applied to the 3 phase 1 hp induction motor and obtained the reasonable results under no load condition. The test results give us the possibility a simple and realistic on-line winding fault diagnosis system.

  • PDF

Real-Time Diagnosis of Incipient Multiple Faults with Application for Kori Nuclear Power Plant (초기 다중고장 실시간 진단기법 개발 및 고리원전 적용)

  • Chung, Hak-Yeong;Zeungnam Bien
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.670-686
    • /
    • 1995
  • This paper provides an improvement on our previous study [1] for multi-fault diagnosis in real time in large-scale systems. In the method, fault propagation probability(FPP) and fault propagation time(FPT) in a fuzzy sense are additively used to describe the fault propagation model(FPM) in more practical manner. A modified fault diagnosis procedure is also given. This method is applied for diagnosis of the primary system in the Kori nuclear power plant unit 2 under a transient condition in case of unit value of FPP on each branch of the FPM.

  • PDF

Fault Diagnosis Method of Power Transformer Using FCM and SOM (FCM과 SOM을 이용한 전력용 변압기 고장진단 기법)

  • Han, Wun-Dong;Lee, Dae-Jong;Ji, Pyeong-Shik
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.3
    • /
    • pp.25-33
    • /
    • 2007
  • The unexpected failure may cause a break in power system and loss of profits. Therefore it Is important to prevent abrupt faults by monitoring the condition of power systems. In this paper, we develop intelligent diagnosis technique for predicting faults of power transformer which plays an important role in the transmission and distribution systems among the various power facilities by using FCM and SOM. More specifically, FCM is used to select the efficient training data and reducing learning process time and SOM is used to diagnosis the power transformer. The proposed technique makes it possible to measures the possibility of aging as well as the faults occurred in transformer To demonstrate the validity of proposed method, various experiments are performed and their results are presented.

A Study on the Insulation Diagnosis to measure Radiated Electromagnetic Waves with Partial Discharge Propagation at being of Conductive Particle in model GIS (모의 GIS 내부에 도전성 이물질 존재시 부분방전 진전에 따른 전자파 측정에 의한 절연진단연구)

  • Park, Kwang-Seo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.157-164
    • /
    • 2008
  • Partial discharge were simulated by conductive particle which could be easy accumulated charge and concentrated electric field in the model GIS. Radiated electromagnetic waves were measured and analyzed by using spectrum analyzer and antenna ($30{\sim}2000[MHz]$) for measurement of EMI EMC in accordance with occurrence and propagation of partial discharge. This paper suggested the other method of detecting and estimating of partial discharge for insulation diagnosis of GIS being conductive particle by measurement and analysis of radiated electromagnetic waves. From results of this study, it was confirmed that if the suggested method should be used for the diagnosis of insulation in the model GIS being conductive particle, detecting partial discharge and estimating discharge propagation will be possible.