• Title/Summary/Keyword: Diagnosis Function

Search Result 1,394, Processing Time 0.029 seconds

A Study on Fault Detection and Fault Device Estimation Method for Cab Cubicle in High Speed Electrical Train (고속전철용 Cab Cubicle의 이상검출과 고장부위 추정에 관한 연구)

  • 장영건;조경환;박계서;최권희
    • Proceedings of the KSR Conference
    • /
    • 2000.05a
    • /
    • pp.188-194
    • /
    • 2000
  • This study is about fault detection and fault area detection of LV circuit in Cab Cubicle system which have control of train to keep safety in High Speed Train. LV circuit is operated with diagnosis system like safety system. In this paper, we suggest a design and an implementation method to detect fault or to detect fault area automatically about LV circuit. The implemented system is tested successfully after implementation of some function. We expect reduction to diagnosis area or repair time by fault area module

  • PDF

The Parameter Estimation of DC-DC Converter by System Identification Method (시스템 식별 기법을 이용한 DC-DC 컨버터 파라메터 추정)

  • Jeon, Jin-Hong;Kim, Tae-Jin;Kim, Kwang-Su;Kim, Kwang-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.503-506
    • /
    • 2003
  • In this paper, we present the results of parameter estimation for do-dc converter model by system identification. The parameter estimation for dc-dc converter aims at the diagnosis of its operating status. we applied the system identification method for parameter estimation. For verification of estimated parameter, we compare bode plot of estimated system transfer function and measurement results of HP4194 instrument.

  • PDF

Pulmonary Function and Influence Factors among Residents around Gwangyang Steel Mill (광양 제철소 주변지역 거주자들의 폐기능과 영향 요인)

  • Hong, Eun-Ju;Ahn, Gi-Sub;Chung, Eun-Kyung;Choi, Jae-Ho;Guo, Xinbiao;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.3
    • /
    • pp.182-192
    • /
    • 2011
  • Objectives: This study aims to identify the influential factors on the pulmonary function of targeted general residents in the areas surrounding Gwangyang Steel Mill. Methods: An PFT (Pulmonary Function Test) was conducted from May 2007 to November 2007 on 974 target residents (438 male, 536 female), including an exposed group (674 people) who resided within a radius of 5 km from Gwangyang Steel Mill in Gwangyang-si, Jeollanam-do and a control group (300 people) who resided outside a radius of 15 km. A survey related to personal characteristics, life habits, respiratory diseases and allergic symptoms, medical histories and living environments of the residents was also conducted to identify influential factors on pulmonary function. Results: As %$FEV_1$ and %FVC of the exposed group are 99.17% and 96.98%, respectively, and those of the control group are 105.47% and 101.91%, respectively, with the PFT values of the exposed group being lower than those of the control group (p<0.001), it turns out that the pollution in the industrial complex is likely to trigger a reduction in the pulmonary function of local residents. The odds ratio analysis result for asthma diagnosis history indicates that the odds ratios tend to be higher among surveyed residents who are living near above-average traffic volumes and are using beds, where it is statistically meaningful that especially the odds ratios are higher if the residences are closer to roads (p<0.01, CI=1.12-4.52). The factors that affect the FEV1 are identified as smoking, passive smoking, asthma diagnosis history, nasal congestion symptoms and allergic eye disease ($R^2$=0.154, p<0.001). The factors that affect the FVC are identified as smoking, passive smoking, asthma diagnosis history and allergic coryza ($R^2$=0.158, p<0.001). In addition, the analysis result for the relevance of air pollution levels to pulmonary function ($FEV_1$, FVC) shows that FEV1 and FVC tend to decrease as the concentration of $O_3$ increases. Conclusions: We believe that this study may provide preliminary data for the development of preventive measures for health effects on the residents and environmental health control measures for environmental pollution in the industrial complex area.

Open Lung Biopsy for Diffuse Infiltrative Lung Disease (미만성 폐질환에 대한 개흉적 폐생검)

  • 김남혁
    • Journal of Chest Surgery
    • /
    • v.28 no.11
    • /
    • pp.1014-1018
    • /
    • 1995
  • To confirm diagnosis and to set proper therapeutic strategy, open lung biopsies were done in 57 patients who were suspected for diffuse interstitial lung disease from January 1985 to December 1994. Among them, 35 were male and 22 were female[M:F=l.6: 1 and mean age of the patients is 53.5$\pm$ 2.3[24-81 years. Tissue for histologic studies were obtained from left lung in 33, from right lung in 24according to the distributions of the pathology. Preoperative diagnostic work-up`s were chest X-ray, CT[HRCT scan, sputum study, bronchoscopy[BAL, TBLB and PTNA and all of them were unsuccessful to confirm diagnosis. In comparison of pulmonary function tests between preoperative and postoperative values, there were no significant differences in FVC, FEV1, FEV1/FVC[p 0.05 but in AaDO2[p[0.05 . Postoperative complications including atelectasis, wound infection, pulmonary edema and respiratory insnfficiency, were shown in 5 cases[8.8% , and two of them were died of respiratory failure and sepsis[mortality rate 3.5% . Pathologic diagnosis was confirmed in 53 cases postoperatively but it was undetermined in 4[diagnostic yield rate 93.0% . In comparison between preoperative clinical diagnosis and postoperative pathologic diagnosis, new diagnosis were made in 17 cases[29.8% and preoperative tentative diagnosis were confirmed histologically in 36 cases[63.2% . In 4 cases[7.0% , however, diagnoses were not confirmed after biopsies. Therapeutic plans were reset in 46 cases[80.7% in accordance with the final diagnosis.In conclusion, open lung biopsy is recommended for a specific diagnosis and proper therapeutic plan in diffuse interstitial lung diseases because of its high diagnostic yield Irate and it`s relatively low morbidity and mortality rate in these tompromised patents.

  • PDF

A Study on Left-Renying and Right-Qikou Pulse Diagnosis(左人迎·右氣口 脈診法) ('좌인영(左人迎)·우기구(右氣口)' 맥진법(脈診法)에 관(關)한 고찰(考察))

  • Kwak, Bumhee;Yoon, Jonghwa
    • Journal of Korean Medical classics
    • /
    • v.33 no.1
    • /
    • pp.89-101
    • /
    • 2020
  • Objectives : The purpose of this study is to research the Left-Renying and Right-Qikou pulse diagnosis. Methods : We set up locations of the Renying pulse(人迎脈) and the Qikou pulse(氣口脈) on left hand and right hand. On the basis of the medical texts and papers, we researched the relations between the Left-Renying and Right-Qikou pulse diagnosis and the etiological factors(病因), background of appearance of the Left-Renying and Right-Qikou pulse diagnosis, and practical use of medical practitioners of many generations to the Left-Renying and Right-Qikou pulse diagnosis. Results & Conclusions : The Left-Renying and Right-Qikou pulse diagnosis is a method to diagnosis the etiological factors, while it could also be assumed as a tool to apply herbal medicine. This assumption could be made based on the seventh volume of 『Maijing(脈經)』 of Wang Shuhe(王叔和). Chen Wuze(陳無擇) emphasized its function to distinguish etiological factors in 『Sanyinjiyibingzhengfanglun(三因極一病證方論)』, as did Li Dongyuan(李東垣) in 『Neiwaishangbianhuolun(內外傷辨惑論)』. Meanwhile, the connection between Left-Renying and Right-Qikou pulse diagnosis and Zangfu(臟腑) seems to have first been made in 『Maiyu(脈語)』 of Wu Kun(吳昆), while 『Zhenjiazhengyan(診家正眼)』 of Li Zhongzi(李中梓) shows traces of progress since the 『Maiyu』.

Electrocardiogram Signal Compression with Reconstruction via Radial Basis Function Interpolation Based on the Vertex

  • Ryu, Chunha;Kim, Tae-Hun;Kim, Jungjoon;Choi, Byung-Jae;Park, Kil-Houm
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.13 no.1
    • /
    • pp.31-38
    • /
    • 2013
  • Patients with heart disease need long-term monitoring of the electrocardiogram (ECG) signal using a portable electrocardiograph. This trend requires the miniaturization of data storage and faster transmission to medical doctors for diagnosis. The ECG signal needs to be utilized for efficient storage, processing and transmission, and its data must contain the important components for diagnosis, such as the P wave, QRS-complex, and T wave. In this study, we select the vertex which has a larger curvature value than the threshold value for compression. Then, we reconstruct the compressed signal using by radial basis function interpolation. This technique guarantees a lower percentage of root mean square difference with respect to the extracted sample points and preserves all the important features of the ECG signal. Its effectiveness has been demonstrated in the experiment using the Massachusetts Institute of Technology and Boston's Beth Israel Hospital arrhythmia database.

Implementation of Uroflow and Urophonography Analysis System for LUTS Diagnosis (하부요로증상 진단을 위한 요속 및 요류음 분석 시스템 구현)

  • Jeon, Gye-Rok;Jeong, Do-Un
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.4
    • /
    • pp.302-309
    • /
    • 2010
  • The present study proposed a method of measuring uroflow and urophonography at the same time for more accurate diagnosis in case uroflow looks normal due to compensatory function hypertrophy in the expression of early obstruction. In case of early obstruction, there happens turbulent uroflow by the obstruction even if the uroflow looks normal and thus obstruction can be detected by measuring and analyzing signal caused by turbulent flow. We implemented a system that can measure both uroflow and urophonography, and evaluated its performance. In the experiment, we observed changes in uroflow and urophonography according to artificial pressure and the degree of obstruction, and confirmed that it is possible to determine the effect of compensatory function hypertrophy by analyzing urophonographyic parameter under the same uroflow. The results of our experiment show that the effect of compensatory function hypertrophy in the early-stage obstruction of lower urinary tract, which is not detectible with uroflowmetry alone, can be assessed through urophonographic analysis.

The Study of Gateway Control Module Using SAE J1939 Protocol (SAE J1939 프로토콜기반 Gateway 제어모듈 개발에 관한 연구)

  • Ko, Youngjin;Kim, Doyeong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.1
    • /
    • pp.128-136
    • /
    • 2013
  • This study presents the development of Gateway Control Module using SAE J1939 protocol for the commercial vehicles. Presently, the load rate of CAN bus is increased by the single network composition and addition of new ECUs for development of intelligent vehicles. Because the embedded system of the integrated network control function has the errors of the CAN bus caused by the increase of ECU, it is needed for development of commercial vehicles. Also, this study presents the development of smart functions that can diagnosis CAN bus errors, fault diagnosis of ECU and basic function that arbitrates CAN bus between ECUs of commercial vehicle. GCM was designed for 4channel separation about Gateway function as solution of load rate decrease and smart functions. HILS(Hardware in the loop simulation)system that can achieve simulation about CAN Messages of all systems on vehicle was applied to evaluate performance and verification of all functions and performance. The load rate on CAN bus was decreased at using functions what was delivery, block and process of GCM. Through this, it was enabled to organize systematic architecture for gateway.

A Study of Matrix Model for Core Quality Measurement based on the Structure and Function Diagnosis of IoT Networks (구조 및 기능 진단을 토대로 한 IoT네트워크 핵심품질 매트릭스 모델 연구)

  • Noh, SiChoon;Kim, Jeom Goo
    • Convergence Security Journal
    • /
    • v.14 no.7
    • /
    • pp.45-51
    • /
    • 2014
  • The most important point in the QoS management system to ensure the quality of the IoT system design goal is quality measurement system and the quality evaluation system. This research study is a matrix model for the IoT based on key quality measures by diagnosis system structure and function. Developing for the quality metrics measured Internet of Things environment will provide the foundation for the Internet of Things quality measurement/analysis. IoT matrix system for quality evaluation is a method to describe the functional requirements and the quality requirements in a single unified table for quality estimation performed. Comprehensive functional requirements and quality requirements by assessing the association can improve the reliability and usability evaluation. When applying the proposed method IoT quality can be improved while reducing the QoS signaling, the processing, the basis for more efficient quality assurances as a whole.

Study on Sasang Constitutional Characteristics using Sasang Personality Questionnaire and Sasang Digestive Function Inventory in Clinical Level (의원급 임상에서 SPQ와 SDFI를 이용한 사상체질별 특징 연구)

  • Lee, Myoung Eun;Seo, Han Gil;Kim, Pan Jun;Chae, Han;Kwon, Young Kyu
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.30 no.6
    • /
    • pp.426-431
    • /
    • 2016
  • Sasang Digestive Function Inventory (SDFI) and Sasang Personality Questionnaire (SPQ) were developed on the basis of clinical experiences of Korean medicine hospital and previous studies have used these for analyzing Sasang constitutional characteristics mainly in hospital level. The purpose of this study is to analyze Sasang constitutional characteristics using SDFI and SPQ in clinical level. The SPQ, SDFI, height and weight were measured with 79 patients over 18-years-old from Jan. 2015 to Apr. 2016 in the clinic, Daegu, Korea that specializes in tinnitus and performs Sasang constitution diagnosis. We used ANOVA in analyzing the differences of the scores of SPQ, SDFI, BMI and PI in each Sasang types (Tae-Yang, So-Yang, Tae-Eum), and Bonferroni test or Dunnett's T3 for post verification. The SDFI-T(F=3.215) and SDFI-D(F=4.347) scores were significantly different(p<0.05) and SPQ score was not different in each Sasang types(p>0.05). And Weight(F=4.294), BMI(F=12.386) and PI(F=14.490) were significantly different in each Sasang types(p<0.001). We found that SDFI(SDFI-D) and BMI PI can explain the Sasang constitutional characteristics, that is equivalent to previous studies and might be used for clinical index in making objective questionnaire for Sasnag constitutional diagnosis in clinical level.