• 제목/요약/키워드: Dewatering System

Search Result 62, Processing Time 0.043 seconds

Study on Thermal Dewatering of Sludge Using the Parabolic Through Collector(PTC) Solar Collector (PTC태양열 집열기를 이용한 슬러지 열탈수 연구)

  • Lee, Jung-Eun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.49-56
    • /
    • 2014
  • A fiat-plate or vacuum tube solar collector have been mainly used for hot water supply of house because of some being difficult to get uniform energy density, so little applied into industrial field. This study is to apply the PTC(parabolic trough collector) solar collector into industrial field such as sludge dewatering system for energy reduction. The real scale system which composed of PTC Solar Collector and Thermal Dewatering (TDW) is established. PTC solar collector is designed to produce a hot water with $80^{\circ}C$ of temperature. And size of TDW is $630{\times}630mm$. Hot water produced from PTC solar collector is supplied into heating plate of TDW, and sludge like waterworks or wastewater is dewatered. PTC solar collector with $10m^2$ of area produce energy of average 5,618 kcal. As according to results from real scale performance, solar collector takes charge 94 % of the amount that TDW consume energy which is so large part if compare with boiler. It means that PTC solar collector is useful to apply industrial field under the condition of sufficient solar radiation. And it is analyzed that TDW by PTC solar collector has an economical validity.

Dewatering Characteristics of Sewage Sludge Produced by the Biological Treatment Process (도시하수 슬러지의 탈수특성 연구)

  • Lee, Jae Bok;Hwang, Jung Wuk;Kwon, Il;Chung, Tai Hak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.9 no.2
    • /
    • pp.84-96
    • /
    • 1995
  • The dewatering characteristics of the sewage sludge was investigated through the experimental observations and model simulations. The activated sludge and the anaerobically digested sludge were examined for the dewaterability evaluation within the pressure range of $0{\sim}10^6N/m^2$. Modified Buchner funnel test and compression test by the consolidometer were conducted to evaluate average specific resistance, porosity, and moisture percentage of filter cake. Shirato's technique of compression-permeability test was followed for the pressure range lower than about $10^2N/m^2$. The flocculation effects on sludge dewatering was also examined for ferric chloride and polymeric flocculant. The application of hydrated lime which can be used for flue-gas desulfurization showed improved moisture percentage, and was thought to have positive feasibility in combined system of sludge dewatering and incineration. Determined characteristic constants were applied to Tiller's cake filtration model to simulate liquid pressure distribution and porosity distribution in cake. Model simulations showed a sharp drop of the porosity close to the cake-medium interface for the highly compressible material such as the activated sludge and the anaerobically digested sludge.

  • PDF

Design and Performance Evaluation of Sludge Dewatering System based on Electrocoagulation and Electroosmosis (전기응집 및 전기탈수을 이용한 슬러지 탈수 성능평가 분석)

  • Shin, Hee-Soo;Yeo, Chang-Sin;Byun, Sang-Hyun;Lee, Jae-Keun
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1992-1997
    • /
    • 2003
  • This study is to develop the pretreatment for the excess and digested sludge by electro-coagulation and dewatering. Electrocoagulation is applied to excess and digested sludge before transferring to the piston type press for dewatering. Piston type filter press as a laboratory scale plant was used to estimate the dewaterability. MMD of excess sludge was increased from initial diameter of particles(34.16 ${\mu}m$) to the 87%(64.01 ${\mu}m$) after electrocoagulation. AI electrode is more effective than Fe electrode for the dewaterability of excess sludge. Electrodewatering after electrocoagulation as pretreatment makes the water content of sludge cake $50{\sim}60$ wt%.

  • PDF

Drainage Simulation in Fourdrinier Paper Machine (장망초지기에서 탈수 시뮬레이션)

  • 김용식;원종명
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.3
    • /
    • pp.10-17
    • /
    • 2000
  • The MDDA(Modified Dynamic Drainage Analyzer) was developed to evaluate the drainage at hydrofoil table roll and low vacuum devices on fourdrinier paper machine MB-former. Comparison of the results was obtained using a computer simulation system based on Taylor's equation and filtration equation and by measuring the consistency profile in a paper machine presented an agreement within 10.7% This device can evaluate the dewatering pro-file on wire for various stock properties adjust dewatering devices on fourdrinier paper machine and control the dosage of retention aids for improving paper structural properties and runnability of papermachine.

  • PDF

A study for Beating Filter Press Dewatering Technology (열(熱) 필터프레스 기술(技術)을 통한 슬러지 탈수율(脫水率) 향상(向上)을 위한 연구(硏究))

  • Lee, Jung-Eun;Kim, Dong-Su
    • Resources Recycling
    • /
    • v.15 no.3 s.71
    • /
    • pp.38-45
    • /
    • 2006
  • The thermal filter press dewatering(TFPD) technology to improve the dewaterability through increasing the inner vapor pressure, lowering the filtration viscosity and forming the porosity easily within cake as applying the heat at the sludge layer was developed in this study. The hot water with temperature of $95^{\circ}C$ and pressure of $1.2kg_f/cm^2$ was supplied to the heating plate equipped between filter plates with plate size of $470{\times}470mm$ and material of polypropylene. Sludge was dewaterd by supplying pressure of $5kg_f/cm^2$ and then by squeezing pressure of $15kg_f/cm^2$. As a results of estimating the characteristics of thermal dewatering to consider the initial water content and organic content to be influenced by a period of water shortage and rainwater, the dewatered cake water content was about 35 wt% and dewatering velocity was $4DSkg/m^2{\cdot}hr$ under the rainwater period, and the dewatered cake water content was about 50 wt% and dewatering velocity was $1.5DSkg/m^2{\cdot}hr$ in the case of sludge of water shortage season. These results was superior to the mechanical dewatering performance with water content of 70wt% and dewatering velocity of $0.9DSkg/m^2{\cdot}hr$. On the base of the results of TFPD, energy consumpted to deal with DS(Dry Solid) of 1kg was estimated by 300 kJ. It was analyzed that the energy consumption of TFPD was decreased about one third with comparison to the dryer system. Dewatering velocity of this technology was faster than the one of mechanical dewatering equipment and it was easier to product low water content cake. Therefore, this technology was recognized that dewaterability was predominant because of the fast of dewatering velocity and production of low water content cake, and also this known as economical efficiency was excellent because of low energy consumption in comparison with dryer.

Application properties of dewatering form system using the Euro-form (유로폼에 대한 투수거푸집의 적용 특성)

  • Lee, Jong-Suk;Ahn, Kee-Hong;Kim, Do-Gyeum;Ahn, Sang-Gu;Min, Jin-Hong;Hong, Hack-Pyo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.601-604
    • /
    • 2008
  • When the concrete is placed, the water, needed for hydration of the cement, is under 30% of W/C including bound and gel water. However, as minimum water content cause bad workability, the W/C have to be higher. Therefore, fresh concrete produce 10${\sim}$20% extra water. As those water remain entrapped air in the concrete, life of the structure is reduced because of the degradation caused by entrapped air. For that reason, if extra water is eliminated, it will be great to improve the durability of the structures. Therefore, this study was performed to verity the fundamental properties through the experiment on the dewatering system using the euro form for eliminating extra water. When the dewatering form was applicated, the compressive strength was increased by 16% than those of normal form. However, the increasing rate of compressive strength got lower as the height is higher. In terms of ultrasonic pulse speed and surface roughness, the dewatering form showed better results than the normal one.

  • PDF

FACTORS OF GROUNDWATER FLUCTUATION IN SHIN KORI NUCLEAR POWER PLANTS IN KOREA

  • Hyun, Seung Gyu;Woo, Nam C.;Kim, Kue-Young;Lee, Hyun-A
    • Nuclear Engineering and Technology
    • /
    • v.45 no.4
    • /
    • pp.539-552
    • /
    • 2013
  • To establish an aging management plan considering seawater influx and changes in groundwater within nuclear power plant sites, the characteristics of groundwater flow must be understood. This study investigated the characteristics of groundwater flow within the site and analyzed groundwater level recorded by monitoring wells to evaluate groundwater flow characteristics and elements that affected these characteristics for supplying the information to conduct the appropriate aging management for ensuring the safety of the safety-related structures in Shin Kori Unit 1 and 2. The increase in groundwater level during the wet season results from high sea-level conditions and the large amount of precipitation. As a result of the analysis of groundwater distribution and change characteristics, the site could be divided into a rainfall-affected area and a tide-affected area. First, the rainfall-affected area can further be divided into areas that are affected simultaneously by excavation, backfill, and a permanent dewatering system. Secondly, areas that are not affected by excavation, or the dewatering system, or by structure arrangement and excavation. Analysis of the spectrum for wells affected by tides resulted in confirmation of the M2 component (12.421 hr) and S2 component (12.000 hr) of the semidiurnal tides, and the O1 component (25.819 hr) of the diurnal tides. In the cross-correlation results regarding tides and groundwater levels, the lag time occurred diversely within 1-3 hours by the effect of the well location from sea, the distribution of the backfill material with depth, and the concrete structure.

Comparison of Improving Dewatering Process at Clay-Sandy Soil based on Pulse-Electrokinetic Technology and Continuous-Electrokinetic Technology (펄스동전기법과 연속처리동전기법을 이용한 점토성-사질토의 탈수화 효율 비교)

  • Shin, Sanghee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.4
    • /
    • pp.37-41
    • /
    • 2014
  • Pulse electrokinetic technology is proposed for improving the dewatering-process from clay-sandy soil. Proposed electrokinetic technology is to be the dewatering process due to fluid movement of current flow for the stability of clay-sandy soils. Samples produced in this study were completed to verify the proposed performance for 7 days by gradually increasing the pressure to the final pressure of 30 psi ($2.11kgf/cm^2$) through the compression process. In this study, pulse electrokinetic treatment and conventional continuous electrokinetic treatment are tested and observed, respectively. The condition of continuous electrokinetic treatment is a continuous process during 48 hours. And the condition of pulse electrokinetic treatment system is to interrupt the power three times for 48 hours, every 8 hours. These treatments are that the voltage gradient is 3 V/cm. As a result, the efficiency of pulse electrokinetic is similar to the continuous electrokinetic. The power consumption efficiency of pulse electrokinetic is better than continuous electrokinetic.

Forward osmosis membrane filtration for microalgae harvesting cultivated in sewage effluent

  • Kim, Su-Bin;Paudel, Sachin;Seo, Gyu Tae
    • Environmental Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.99-104
    • /
    • 2015
  • The purpose of this study is to evaluate the performance of forward osmosis (FO) system for harvesting microalgae cultivated in secondary sewage effluent. Microalgae species used in this study were chlorella sp. ADE4. The drawing agents used for forward osmosis system were seawater and concentrate of sea water reverse osmosis (SWRO) system. Chlorella sp. ADE4 cultured in secondary sewage effluent illustrated moderate efficiency in removal of total nitrogen (TN) (68%) and superior performance in total phosphorus (TP) removal (99%). Comparison of seawater and SWRO concentrate as drawing agent were made in FO membrane separation of the microalgae. The result from this study depicts that SWRO concentrate is strong drawing agent in FO membrane system providing an average dewatering rate of $4.8L/(m^2{\cdot}hr)$ compared to seawater with average dewatering of $2.9L/(m^2{\cdot}hr)$. Results obtained from this study indicated that FO system could be viable option for harvesting the microalgae for further biodiesel production. SWRO concentrate as a drawing agent could be very important finding in field of membrane technology for disposal of SWRO concentrate.