• 제목/요약/키워드: Dew Point

검색결과 192건 처리시간 0.032초

열전소자를 이용한 배수형 전자제습기 개발 (Development of a Drain-Type Electronic Dehumidifier Using Thermoelectric Element)

  • 강덕홍;김성완;김기홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3524-3528
    • /
    • 2007
  • In this study, the Peltier effect was applied to eliminate moistures in the air enclosed by a cabinet. We have developed the new electronic dehumidifier which has a new function of automatically evaporating the condensed water inner cabinet into the outside air. To obtain this function, the processes of dehumidification is that it condensed the moistures on the cold side heat sink and drained it into the hot side heat sink by the both gravitational and capillary forces and the droplets on the hot side heat sink surface was evaporated into the air outside the cabinet by the heat conducted through the hot side heat sink surface and the forced heat convection through the fan for cooling hot side heat sink. Compared to existing electronic dehumidifiers, this manufactured one showed a good performance that the electric power consumption for the same dehumidifying quantity was reduced by 50% compared with that of existing ones.

  • PDF

DRYING CHARACTERISTINCS OF THIN-LAYERS OF WHEAT AND BARLEY AT NEAR-AMBIENT TEMPERATURE

  • Sun, Da-Wen;J.J.Woods
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.896-905
    • /
    • 1993
  • Thin-layers of wheat and barley are dried at near-ambient temperatures(3.5$^{\circ}C$ -5$0^{\circ}C$) in order to obtain the intrinsic drying data. The well established apparatus was modified to enable it to record all the sample weight data in still air by using a purpose -built automatically controlled sliding valve. The air could be diverted in less than 0.5seconds and a 7 second period was required to attain a steady weight reading. With this apparatus, very smooth drying curves were obtained. The data of sample weight , drying temperature and dew point temperature wee recorded continuously . The drying process was terminated when the moisture content change in 24 hours was less than 0.004 d.b. This was achieved by drying a sample for about a week . The final points were recorded as the dynamic equilibrium moisture content(EMC). The drying data were than fitted to the exponential Newton model and the dynamic EMC data were fitted to the Modified-Chung-Pfost Model . All the fitted parameters are given and comparison is made with previous published data. The comparisons who that the current drying constants are lower than the previous data, the dynamic EMC data obtained for wheat and barely agree with the previous data. The results show that to obtain the drying constant in the exponential Newton model, adequate drying time is necessary.

  • PDF

Status of PM10 as an air pollutant and prediction using meteorological indexes in Shiraz, Iran

  • Masoudi, Masoud;Poor, Neda Rajai;Ordibeheshti, Fatemeh
    • Advances in environmental research
    • /
    • 제7권2호
    • /
    • pp.109-120
    • /
    • 2018
  • In the present study research air quality analyses for $PM_{10}$, were conducted in Shiraz, a city in the south of Iran. The measurements were taken from 2011 through 2012 in two different locations to prepare average data in the city. The averages concentrations were calculated for every 24 hours, each month and each season. Results showed that the highest concentration of $PM_{10}$ occurs generally in the night while the least concentration was found at the afternoon. Monthly concentrations of $PM_{10}$ showed highest value in August, while least value was found in January. The seasonal concentrations showed the least amounts in autumn while the highest amounts in summer. Relations between the air pollutant and some meteorological parameters were calculated statistically using the daily average data. The wind data (velocity, direction), relative humidity, temperature, sunshine periods, evaporation, dew point and rainfall were considered as independent variables. The relationships between concentration of pollutant and meteorological parameters were expressed by multiple linear regression equations for both annual and seasonal conditions SPSS software. RMSE test showed that among different prediction models, stepwise model is the best option.

태안마애삼존불의 보존과학적 훼손도 진단과 보존환경 분석 (Analysis of Conservation Scientific Deterioration Diagnosis and Conservation Environment of the Samjonbul Carved on Rock Surface in Taean, Korea)

  • 엄두성;전병규;한민수;이장존;송치영
    • 보존과학연구
    • /
    • 통권29호
    • /
    • pp.19-44
    • /
    • 2008
  • Sam-jon-bul or Three Buddha Image Carved on rock surface which is called Sam-jon-bul in Taean, state-designated national treasure No. 307, made in Baek-je Period, has two Buddha images and one Bodhisattva. The detached part of the Sam-jon-bul from wall rock has been attached through conservation treatment in 1995. Few study has been done on weathering condition of petrological point of view and damage while the surface of the Sam-jon-bul has been under serious weathering (relief) of loosing stone particles, and discoloration. In this study, it was made weathering damage maps, which show physical property of the material and state of damage of Sam-jon-bul, in order to dialogize how far the weathering has been done. It has been considered continuing on-site monitoring as necessity when Sam-jon-bul was covered with dew, which may have been caused by change in weather in and out of the protect building. It is necessary to set up detailed conservation plan for it by doing regular diagnosis on the influence of the protect building and weathering of Sam-jon-bul.

  • PDF

욕실과 인접한 아파트 드레스룸의 결로 원인 분석 (An Experimental and Simulation Analysis of Condensation in the Walk-in Closet Attached to Apartment Bathroom)

  • 최영우;김선혜
    • KIEAE Journal
    • /
    • 제17권4호
    • /
    • pp.89-94
    • /
    • 2017
  • Purpose: Condensation in walk-in closets attached to apartment bathroom has been known as an emerging issue that may threat occupants' comfort and health. Despite a number of design guidelines and enforcements to prevent condensation, condensation issues may still occur depending on various cases and scenarios. We aim to identify what condensation scenarios may lead to walk-in closet condensation and/or worse the existing condensation issues. Method: First we choose an actual walk-in closet of an apartment that suffers from sporadic condensation and resulting mold and mildew. Then we observe its relative humidity and temperature after the bathroom is used, in which excessive vapor is thought to be transported to the walk-in closet. We analyze Temperature Difference Ratio - a domestic indicator of condensation occurrence, and dew point temperature to compare it with surface temperature using 2D heat transfer simulation upon various condensation scenarios. Result: TDR of the test walk-in closet turns out be OK despite mold and mildew actually occurring. Hot water pipe installed in the floor would greatly reduce condensation. If hot water pipe in the upper floor, however, is not used, or hot water pipe of the closet is turned off during swing seasons, it is expected that condensations may still occur.

군용헬기 결빙 감항인증을 위한 국내 기상환경에 관한 연구 (A Study on the Korea Weather Environment for Icing Airworthiness of Military Helicopter)

  • 허장욱;신백천
    • 한국군사과학기술학회지
    • /
    • 제17권3호
    • /
    • pp.304-310
    • /
    • 2014
  • Based on atmosphere weather data by balloon in Osan and Gwangju area, if icing condition occurs in weather environment of altitude range where helicopter is operated was analyzed in quantitative way. Yearly icing occurrence frequency for daytime during recent three years was average 102 days in Osan, average 91 days in Gwangju. Icing weather environment to highly affect operation of helicopter varies a little according to analysis methods but icing intensity at MDT level was calculated in all the methods, and 14.5~38 times was suggested in Osan; 2.5~30 times in Gwangju. Icing at MDT level was calculated in common in all the analysis methods through wide periods such as Jan., Feb., Mar., and Nov. in Osan. In Gwangju, icing at MDT level was suggested focusing on Jan. only. Therefore, military helicopter developed in Korea is required to strive obtaining certificate of airworthiness about icing condition at MDT level for implementation of perfect operational mission and safe operation.

한국남서연안해역의 저수온 출현과 안개 형성과의 관련성에 관한 연구 (A Study on Relationship between Cold Water Appearance and Fog Formation in the Southwest Coastal Waters of Korea)

  • 윤종휘;정희동;조규대;이충일
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2004년도 추계학술발표회
    • /
    • pp.123-127
    • /
    • 2004
  • It is known that cold water appears and fog frequently forms in the southwest coastal waters of Korea in summer. The authors investigate the time and place. of cold water existence, and also whether the cold water affects the occurrence of fog formation. As a result, cold water begins to appear around Daeheugsando at the early summer. It gets colder with times and cold water area moves toward southwest of Jindo in mid-summer, then disappears in this area around mid-Oct. Fog mostly forms in April through August and most frequently occurs at Chukdo(Jindo) where sea surface temperature shows lower than that at the adjacent area. Accordingly it is taken that the cold water is considerably contributed to form the dense and frequent fog around Jindo area.

  • PDF

경기도 안양시 오존농도의 시계열모형 연구 (Analysis of Time Series Models for Ozone Concentration at Anyang City of Gyeonggi-Do in Korea)

  • 이훈자
    • 한국대기환경학회지
    • /
    • 제24권5호
    • /
    • pp.604-612
    • /
    • 2008
  • The ozone concentration is one of the important environmental issue for measurement of the atmospheric condition of the country. This study focuses on applying the Autoregressive Error (ARE) model for analyzing the ozone data at middle part of the Gyeonggi-Do, Anyang monitoring site in Korea. In the ARE model, eight meteorological variables and four pollution variables are used as the explanatory variables. The eight meteorological variables are daily maximum temperature, wind speed, amount of cloud, global radiation, relative humidity, rainfall, dew point temperature, and water vapor pressure. The four air pollution variables are sulfur dioxide $(SO_2)$, nitrogen dioxide $(NO_2)$, carbon monoxide (CO), and particulate matter 10 (PM10). The result shows that ARE models both overall and monthly data are suited for describing the oBone concentration. In the ARE model for overall ozone data, ozone concentration can be explained about 71% to by the PM10, global radiation and wind speed. Also the four types of ARE models for high level of ozone data (over 80 ppb) have been analyzed. In the best ARE model for high level of ozone data, ozone can be explained about 96% by the PM10, daliy maximum temperature, and cloud amount.

습증기를 포함한 연소가스의 폐열회수를 위한 열교환기 성능 예측 (Performance Prediction of Heat Exchanger for Waste Heat Recovery from Humid Flue Gases)

  • 정동운;이상용;이한주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.276-281
    • /
    • 2000
  • A simulation program using the mass transfer correlation was constructed to analyze 1-D simplified condensing flow across the tube bank. Higher efficiency was anticipated by reducing the flue gas temperature down below the dew point where the water vapor in the flue gas is condensed at the surface of the heat exchanger; that is, the heat transfer by the latent heat is added to that by the sensible heat. Thus, there can be an optimum operating condition to maximize the heat recovery from the flue gas. The temperature rises of the flue gas and the cooling water between the inlet and the outlet of the tube bank were compared with the experimental data reported previously. The predicted results agree well with the experimental data. Using this simulation program, the parametric studies have been conducted fur various operating conditions, such as the velocities and temperatures of the vapor/gas mixture and the cooling water, the number of the rows, and the conductivity of the wall material.

  • PDF

건물 성능디자인을 위한 미기후 기반 기상데이터의 기존 기상데이터와 비교를 통한 활용 가능성 연구 (A study on Applicability through Comparison of Weather Data based on Micro-climate with existing Weather Data for Building Performative Design)

  • 김언용;전한종
    • KIEAE Journal
    • /
    • 제11권6호
    • /
    • pp.101-108
    • /
    • 2011
  • The weather data has important role for performative building design. If the data location is close to building site, the result of performative design can be accurate. The data which have used nowadays in Korea are from U.S. Department of Energy (DOE) and Korea Solar Energy Society (KSES) but they cover only several locations in Korea which are 4 in DOE and 11 in KSES and there are opinions which it could be served building design efficiently even if the data are not enough. However the weather data for micro-climate are exist which are Green Building Studio Virtual Weather Station (GBS VWS) and Meteonorm weather data. Each weather data has different generation methods which are TMY2, TRY, MM5, and extrapolation. In this research, the weather date for climate are compared with DOE and KSES to check correlation. The result shows the value of correlation in Dry Bulb Temp. and Dew Point Temp. is around 0.9 so they have high correlation in both but in Wind Speed case the correlation(around 0.2) is not exist. In overall result, the data has correlation with DOE and KSES as the value of correlation 0.648 of GBS VW and 0.656 of Meteonorm. Even if the correlation value is not high enough, the patterns of difference in each weather element are similar in scatter plot.