• Title/Summary/Keyword: Dew

Search Result 314, Processing Time 0.025 seconds

Analysis on the Thermal Performance of an Ammonia Unit Cooler (암모니아 유니트 쿨러의 열성능 해석)

  • 최재광;김무근;박병규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1125-1133
    • /
    • 2001
  • Since the surface temperature of the evaporating tube in an ammonia unit cooled is lower than the dew point of atmosphere, the moisture in the atmosphere condenses and the frost grows on the tube. The frost of liquid film decreases the heat transfer rate. The reliable analysis of the heat transfer is required for the prediction of the optimal design of the ammonia unit cooler. For the specific commercial model, the performance was numerical1y estimated for the variation of operating condition and geometric configuration. It is found that there exists an optimum range for the parameters such as mass flow rate of air and refrigerant, humidity, refrigerant quality, fin pitch, the number of step, the number of rows and the pattern of refrigerant path.

  • PDF

A Study on the Application of the Dehumidification System for Radiant Floor Cooling Using Ondol (온돌을 이용한 바닥복사냉방의 제습시스템 적용에 관한 연구)

  • 임재한;여명석;양인호;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.7
    • /
    • pp.607-616
    • /
    • 2002
  • This study has been conducted to evaluate the applicability of the control method in the dehumidification-integrated radiant floor cooling system in terms of stability of the room air temperature and the control variables through experiments. To do this, the relationship between the control variables in preventing floor surface condensation is first analyzed and the control method is predetermined through simulations. The results are as follows. First, it is necessary to determine the operation status of the dehumidification system according to the relationship between floor surface temperature and dew point temperature in the conditioned space. Second, outdoor reset with indoor temperature feedback control is better than on/off bang-bang control with respect to temperature stability in controlling the room air temperature and the possibility of energy savings. Finally, the humidity sensor can be located with the current thermostat in that there are small differences in absolute humidity in vertical distribution.

A Study on the Wiring Plan Considering Construction and Frame Performance Degradation of BIPV System (BIPV시스템 시공 및 프레임 성능저하를 고려한 배선처리방안 제시에 관한 연구)

  • Oh, Min-Seok;Kim, Gi-Cheol
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.4
    • /
    • pp.33-42
    • /
    • 2018
  • In the application of the BIPV system, it is expected that the workability is lowered due to the difficulty in securing the space for wiring in the frame and the performance of the frame due to the wiring hole processing is lowered. Therefore, In this study, we propose a method to improve the wiring of the inner space of the BIPV frame, and through the simulation evaluation process, the thermal and condensation performance are secured by complementing the problems caused by the hole machining, and the time and effort required for BIPV construction are reduced. For this purpose, a wiring treatment method using a flange insertion tube was proposed, and the thermal and condensation performance was evaluated through simulation analysis.

Insulation Method and Performance Evaluation for Fastening Unit of ALC Pannel-Curtain wall (ALC 패널 커튼월의 패스닝 유닛의 단열 방법과 성능 평가)

  • Kim, Bongl-Joo;Kim, Kyeong-A;Park, Je-Min
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.107-110
    • /
    • 2011
  • In this study is to improve insulation performance that are the most weak insulation part of fastening unit of the curtain wall. It was produced that thought out to minimize mullion and connecting part, and evaluated performance that make a layer of insulation in the middle by using vibration-proof rubber or silicon. Vibration-proof rubber insulation is 2.6℃~4.0℃ higher and silicon insulation is 2.4℃ higher than non-insulation. Therefore the insulating layer of fastening unit is necessary.

  • PDF

Effect of Oxygen Partial Pressure on Tungsten-Alumina Bonding Behavior (텅스텐-알루미나 접합거동에 미치는 산소분압의 영향)

  • 박정현;이상진
    • Journal of the Korean Ceramic Society
    • /
    • v.27 no.6
    • /
    • pp.755-762
    • /
    • 1990
  • The tungsten paste was printed on the surface of 92% alumina sheet which was made by type casting process. The printed tungsten was bonded on the Al2O3 by co-firing in reducing atmosphere. During the co-firing, the binder burn-out was easier in wet H2 atmosphere than in dry H2, which affected sintered density. In practically, the use of wet H2 above 100$0^{\circ}C$ was beneficial for density of alumina and bond strength. This phenomena occured more distinctly when atmosphere varied from dry H2 to wet H2 than varied dew point in wet H2. In wet H2, the improvement in bonding strength can be attributed to good glass migration into the metal layer due to inhibition of the tungsten particle growth, with increase of alumina density, at the temperatrue higher than 100$0^{\circ}C$.

  • PDF

a disoved and adsorptive Mechanism of water at Oil and Paper (절연유와 절연지의 수분에 대한 용존 및 흡착 메커니즘 특성)

  • Han, Sang-Gil;Han, Sang-Ok;Lee, Sei-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.49-51
    • /
    • 2007
  • 수분은 변압기 내부의 절연물의 절연내력에 악영향을 끼치므로, 변압기 열화진단의 중요한 요소이다. 이러한 수분을 검출하기 위한 여러 가지 방법들(Karl-Fischer법, Dew-Point법, RVM 등)이 개발되어졌고, 현재도 많은 연구가 진행되어 지고 있다. 본 논문에서는 회복전압측정법(RVM : Return Voltage Measurements)과 FDS(Frequency Domain Spectrum)를 이용하여 변압기의 여러 구성물(절연지, 전극, 절연유 등)들과 수분과의 반응 메커니즘을 분석하였다. 눈으로 확인할 수 없는 부분을 규명함으로서 앞으로 변압기 열화진단법들의 개발에 기여하고자 하였다.

  • PDF

The Characteristics of RVM Curve at Moisture Content (수분함유량에 따른 RVM 특성곡선의 특성)

  • Han, Hee-Joon;Kim, Ju-Han;Kang, Seok-Young;Lee, Sei-Hyun;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.45-46
    • /
    • 2006
  • 변압기 내부의 수분은 절연물의 절연내력에 악영향을 끼치므로 수분측정은 변압기 사고예방과 수명연장에 매우 중요하다. 변압기 내의 수분함유량을 검출하는 시험법으로 Karl-Fischer법과 Dew-Point법을 사용해 왔다. 그러나 이 시험법은 기기를 분해해야 하고, 국부적인 부분에 대한 정보일 뿐 아니라 분석을 즉시 현장에서 하지 못하는 단점이 있다. 따라서 기존 시험법의 단점을 보완하기 위해 회복전압법(RVM, Return Voltage Method)이 제안되었다. 본 논문에서는 모의 셀 내부에 수분을 강제로 주입하여 수분함유량 변화를 주고 Karl-Fischer법을 통한 수분함유량 측정 결과와 RVM 특성 곡선을 비교 분석하였다.

  • PDF

TOVS retrieved data with the real time synoptic surface data (종관 지상 자료를 이용한 TOVS수치 해석 산출 자료)

  • 주상원;정효상;김금란
    • Korean Journal of Remote Sensing
    • /
    • v.10 no.1
    • /
    • pp.55-67
    • /
    • 1994
  • The International TOVS(TIROS Oprational Vertical Sounders) Process Package(ITPP-VI)is for a global usage, which needs a surface data to generate atmospheric soundings. If the initial input process in the ITPP-VI is not modified, it takes climatic surface data for producing sounding data in general. Korea Meteorological Administration(KMA) is trying to improve the quality of TOVS sounding data using real-time synoptic observations and make a use weather prediction and analysis in various ways. Serval cases in this study show that TOVS retrieved meteolorogical parameters such as atmopheric temperature, dew point depression and geopotential heights used by synoptic surface observations can delineate more detailed atmospheric feature rather than those used by climate surface data. In addition, the collocated comparisons of TOVS synoptic retrieved parameters with radiosonde observations are performed statistically. TOVS retrieved fields with the synoptic surface analyzed data show smaller bias reatively than those with the climatic data and also reduced root mean square differences below 700 hPa as expected.

A Study on Development of Flux to Restrict Occurrence of ion Migration in Lead-Free Solder (무연솔더 내 마이그레이션 플럭스개발에 관한 연구)

  • Ryu Dong Su;Lim Jae Hoon;Woo Seong Woo
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2005.06a
    • /
    • pp.385-392
    • /
    • 2005
  • The restriction of the use of hazardous substances in electrical and electronic equipment legislation mandates the substitution of lead and other hazardous substances in electronics products by July 2006. Due to this legislative pressure, the electronics industry is moving to adoption of lead free solders. In this paper, we investigated a flux to restrict generating electrochemical migration in lead-free solder. The lead-free solders used in this study were Sn-0.7Cu-0.01P and Sn-3.0Ag-0.5Cu. To measure the resistance of electrochemical migration, the dew-cycle test and water drop test were adopted. As the result, now flux having high durable of electrochemical migration was developed.

  • PDF

Dryer Design for High Altitude Engine Test (고공 엔진시험을 위한 Dryer 개발)

  • Park, Berm-Joo;Kim, Tea-In
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.419-423
    • /
    • 2008
  • 엔진 성능의 시험에 있어서 작동유체인 압축공기의 물성중 수분은 매우 중요한 부분으로, 엔진의 작동과 성능에 영향을 미치는 대표적인 요인이다. 특히 고공환경 시험에서는 습도의 조건에 따라 성능의 차이가 커지므로 엔진의 정확한 성능과 운용성을 파악하는데 작동유체인 압축공기중에 포함된 수분의 조건은 대단히 중요하다. 압축상태인 작동유체의 수분 함유량을 고공의 조건과 같은 $-40^{\circ}C$ 이하의 이슬점(Dew Point) 상태로 제습 하기 위한 장치인 흡착식 Air Dryer의 개발을 위해 흡착과정 및 재생과정에 대한 이해와 흡착제의 흡착효율을 극대화하고, 재생비용을 최소화하여 에너지를 저감 할 수 있는 Air Dryer System에 대하여 기술한다.

  • PDF