• Title/Summary/Keyword: Device-to-device

Search Result 25,588, Processing Time 0.063 seconds

Risk Analysis of Arsenic in Rice Using by HPLC-ICP-MS (HPLC-ICP-MS를 이용한 쌀의 비소 위해도 평가)

  • An, Jae-Min;Park, Dae-Han;Hwang, Hyang-Ran;Chang, Soon-Young;Kwon, Mi-Jung;Kim, In-Sook;Kim, Ik-Ro;Lee, Hye-Min;Lim, Hyun-Ji;Park, Jae-Ok;Lee, Gwang-Hee
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.4
    • /
    • pp.291-301
    • /
    • 2018
  • BACKGROUND: Rice is one of the main sources for inorganic arsenic among the consumed crops in the world population's diet. Arsenic is classified into Group 1 as it is carcinogenic for humans, according to the IARC. This study was carried out to assess dietary exposure risk of inorganic arsenic in husked rice and polished rice to the Korean population health. METHODS AND RESULTS: Total arsenic was determined using microwave device and ICP-MS. Inorganic arsenic was determined by ICP-MS coupled with HPLC system. The HPLC-ICP-MS analysis was optimized based on the limit of detection, limit of quantitation, and recovery ratio to be $0.73-1.24{\mu}g/kg$, $2.41-4.09{\mu}g/kg$, and 96.5-98.9%, respectively. The inorganic arsenic concentrations of daily exposure (included in body weight) were $4.97{\times}10^{-3}$ (${\geq}20$ years old) $-1.36{\times}10^{-2}$ (${\leq}2$ years old) ${\mu}g/kg\;b.w./day$ (PTWI 0.23-0.63%) by the husked rice, and $1.39{\times}10^{-1}$ (${\geq}20$ years old) $-3.21{\times}10^{-1}$ (${\leq}2$ years old) ${\mu}g/kg\;b.w./day$ (PTWI 6.47-15.00%) by the polished rice. CONCLUSION: The levels of overall exposure to total and inorganic arsenic by the husked and polished rice were far lower than the recommended levels of The Joint FAO/WHO Expert Committee on Food Additives (JECFA), indicating of little possibility of risk.

Application of a Single-pulsatile Extracorporeal Life Support System for Extracorporeal Membrane Oxygenation -An experimental study - (단일 박동형 생명구조장치의 인공폐 적용 -실험연구-)

  • Kim, Tae-Sik;Sun, Kyung;Lee, Kyu-Baek;Park, Sung-Young;Hwang, Jae-Joon;Son, Ho-Sung;Kim, Kwang-Taik;Kim. Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.201-209
    • /
    • 2004
  • Extracorporeal life support (ECLS) system is a device for respiratory and/or heart failure treatment, and there have been many trials for development and clinical application in the world. Currently, a non-pulsatile blood pump is a standard for ECLS system. Although a pulsatile blood pump is advantageous in physiologic aspects, high pressure generated in the circuits and resultant blood cell trauma remain major concerns which make one reluctant to use a pulsatile blood pump in artificial lung circuits containing a membrane oxygenator. The study was designed to evaluate the hypothesis that placement of a pressure-relieving compliance chamber between a pulsatile pump and a membrane oxygenator might reduce the above mentioned side effects while providing physiologic pulsatile blood flow. The study was performed in a canine model of oleic acid induced acute lung injury (N=16). The animals were divided into three groups according to the type of pump used and the presence of the compliance chamber, In group 1, a non-pulsatile centrifugal pump was used as a control (n=6). In group 2 (n=4), a single-pulsatile pump was used. In group 3 (n=6), a single-pulsatile pump equipped with a compliance chamber was used. The experimental model was a partial bypass between the right atrium and the aorta at a pump flow of 1.8∼2 L/min for 2 hours. The observed parameters were focused on hemodynamic changes, intra-circuit pressure, laboratory studies for blood profile, and the effect on blood cell trauma. In hemodynamics, the pulsatile group II & III generated higher arterial pulse pressure (47$\pm$ 10 and 41 $\pm$ 9 mmHg) than the nonpulsatile group 1 (17 $\pm$ 7 mmHg, p<0.001). The intra-circuit pressure at membrane oxygenator were 222 $\pm$ 8 mmHg in group 1, 739 $\pm$ 35 mmHg in group 2, and 470 $\pm$ 17 mmHg in group 3 (p<0.001). At 2 hour bypass, arterial oxygen partial pressures were significantly higher in the pulsatile group 2 & 3 than in the non-pulsatile group 1 (77 $\pm$ 41 mmHg in group 1, 96 $\pm$ 48 mmHg in group 2, and 97 $\pm$ 25 mmHg in group 3: p<0.05). The levels of plasma free hemoglobin which was an indicator of blood cell trauma were lowest in group 1, highest in group 2, and significantly decreased in group 3 (55.7 $\pm$ 43.3, 162.8 $\pm$ 113.6, 82.5 $\pm$ 25.1 mg%, respectively; p<0.05). Other laboratory findings for blood profile were not different. The above results imply that the pulsatile blood pump is beneficial in oxygenation while deleterious in the aspects to high pressure generation in the circuits and blood cell trauma. However, when a pressure-relieving compliance chamber is applied between the pulsatile pump and a membrane oxygenator, it can significantly reduce the high circuit pressure and result in low blood cell trauma.

The Effect of Nasal BiPAP Ventilation in Acute Exacerbation of Chronic Obstructive Airway Disease (만성 기도폐쇄환자에서 급성 호흡 부전시 BiPAP 환기법의 치료 효과)

  • Cho, Young-Bok;Kim, Ki-Beom;Lee, Hak-Jun;Chung, Jin-Hong;Lee, Kwan-Ho;Lee, Hyun-Woo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.2
    • /
    • pp.190-200
    • /
    • 1996
  • Background : Mechanical ventilation constitutes the last therapeutic method for acute respiratory failure when oxygen therapy and medical treatment fail to improve the respiratory status of the patient. This invasive ventilation, classically administered by endotracheal intubation or by tracheostomy, is associated with significant mortality and morbidity. Consequently, any less invasive method able to avoid the use of endotracheal ventilation would appear to be useful in high risk patient. Over recent years, the efficacy of nasal mask ventilation has been demonstrated in the treatment of chronic restrictive respiratory failure, particularly in patients with neuromuscular diseases. More recently, this method has been successfully used in the treatment of acute respiratory failure due to parenchymal disease. Method : We assessed the efficacy of Bilevel positive airway pressure(BiPAP) in the treatment of acute exacerbation of chronic obstructive pulmonary disease(COPD). This study prospectively evaluated the clinical effectiveness of a treatment schedule with positive pressure ventilation via nasal mask(Respironics BiPAP device) in 22 patients with acute exacerbations of COPD. Eleven patients with acute exacerbations of COPD were treated with nasal pressure support ventilation delivered via a nasal ventilatory support system plus standard treatment for 3 consecutive days. An additional 11 control patients were treated only with standard treatment. The standard treatment consisted of medical and oxygen therapy. The nasal BiPAP was delivered by a pressure support ventilator in spontaneous timed mode and at an inspiratory positive airway pressure $6-8cmH_2O$ and an expiratory positive airway pressure $3-4cmH_2O$. Patients were evaluated with physical examination(respiratory rate), modified Borg scale and arterial blood gas before and after the acute therapeutic intervention. Results : Pretreatment and after 3 days of treatment, mean $PaO_2$ was 56.3mmHg and 79.1mmHg (p<0.05) in BiPAP group and 56.9mmHg and 70.2mmHg (p<0.05) in conventional treatment (CT) group and $PaCO_2$ was 63.9mmHg and 56.9mmHg (p<0.05) in BiPAP group and 53mmHg and 52.8mmHg in CT group respectively. pH was 7.36 and 7.41 (p<0.05) in BiPAP group and 7.37 and 7.38 in cr group respectively. Pretreatment and after treatment, mean respiratory rate was 28 and 23 beats/min in BiPAP group and 25 and 20 beats/min in CT group respectively. Borg scale was 7.6 and 4.7 in BiPAP group and 6.4 and 3.8 in CT group respectively. There were significant differences between the two groups in changes of mean $PaO_2$, $PaCO_2$ and pH respectively. Conclusion: We conclude that short-term nasal pressure-support ventilation delivered via nasal BiPAP in the treatment of acute exacerbation of COPD, is an efficient mode of assisted ventilation for improving blood gas values and dyspnea sensation and may reduce the need for endotracheal intubation with mechanical ventilation.

  • PDF

Evaluating efficiency of application the skin flash for left breast IMRT. (왼쪽 유방암 세기변조방사선 치료시 Skin Flash 적용에 대한 유용성 평가)

  • Lim, Kyoung Dal;Seo, Seok Jin;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.49-63
    • /
    • 2018
  • Purpose : The purpose of this study is investigating the changes of treatment plan and comparing skin dose with or without the skin flash. To investigate optimal applications of the skin flash, the changes of skin dose of each plans by various thicknesses of skin flash were measured and analyzed also. Methods and Material : Anthropomorphic phantom was scanned by CT for this study. The 2 fields hybrid IMRT and the 6 fields static IMRT were generated from the Eclipse (ver. 13.7.16, Varian, USA) RTP system. Additional plans were generated from each IMRT plans by changing skin flash thickness to 0.5 cm, 1.0 cm, 1.5 cm, 2.0 cm and 2.5 cm. MU and maximum doses were measured also. The treatment equipment was 6MV of VitalBeam (Varian Medical System, USA). Measuring device was a metal oxide semiconductor field-effect transistor(MOSFET). Measuring points of skin doses are upper (1), middle (2) and lower (3) positions from center of the left breast of the phantom. Other points of skin doses, artificially moved to medial and lateral sides by 0.5 cm, were also measured. Results : The reference value of 2F-hIMRT was 206.7 cGy at 1, 186.7 cGy at 2, and 222 cGy at 3, and reference values of 6F-sIMRT were measured at 192 cGy at 1, 213 cGy at 2, and 215 cGy at 3. In comparison with these reference values, the first measurement point in 2F-hIMRT was 261.3 cGy with a skin flash 2.0 cm and 2.5 cm, and the highest dose difference was 26.1 %diff. and 5.6 %diff, respectively. The third measurement point was 245.3 cGy and 10.5 %diff at the skin flash 2.5 cm. In the 6F-sIMRT, the highest dose difference was observed at 216.3 cGy and 12.7 %diff. when applying the skin flash 2.0 cm for the first measurement point and the dose difference was the largest at the application point of 2.0 cm, not the skin flash 2.5 cm for each measurement point. In cases of medial 0.5 cm shift points of 2F-hIMRT and 6F-sIMRT without skin flash, the measured value was -75.2 %diff. and -70.1 %diff. at 2F, At -14.8, -12.5, and -21.0 %diff. at the 1st, 2nd and 3rd measurement points, respectively. Generally, both treatment plans showed an increase in total MU, maximum dose and %diff as skin flash thickness increased, except for some results. The difference of skin dose using 0.5 cm thickness of skin flash was lowest lesser than 20 % in every conditions. Conclusion : Minimizing the thickness of skin flash by 0.5 cm is considered most ideal because it makes it possible to keep down MUs and lowering maximum doses. In addition, It was found that MUs, maximum doses and differences of skin doses did not increase infinitely as skin flash thickness increase by. If the error margin caused by PTV or other factors is lesser than 1.0 cm, It is considered that there will be many advantages in with the skin flash technique comparing without it.

  • PDF

Transformation of Adult Mesenchymal Stem Cells into Cardiomyocytes with 5-azacytidine: Isolated from the Adipose Tissues of Rat (성체 백서의 지방조직에서 추출한 중간엽 줄기세포의 5-azacytidine을 이용한 심근세포 분화 유도)

  • Choe Ju-Won;Kim Yong-In;Oh Tae-Yun;Cho Dai-Yoon;Sohn Dong-Suep;Lee Tae-Jin
    • Journal of Chest Surgery
    • /
    • v.39 no.7 s.264
    • /
    • pp.511-519
    • /
    • 2006
  • Background: Loss of cardiomyocytes in the myocardial infarction leads to regional contractile dysfunction, and necrotized cardiomyocytes in infracted ventricular tissues are progressively replaced by fibroblasts forming scar tissue. Although cardiomyoplasty, or implantation of ventricular assist device or artificial heart was tried in refractory heart failure, the cardiac transplantation was the only therapeutic modality because these other therapeutic strategies were not permanent. Cell transplantation is tried instead of cardiac transplantation, especially bone marrow is the most popular donated organ. But because bone marrow aspiration procedure is invasive and painful, and it had the fewer amounts of cellular population, the adipose tissue is recommended for harvesting of mesenchymal stem cells. Material and Method: After adipose tissues were extracted from abdominal subcutaneous adipose tissue and intra-abdominal adipose tissue individually, the cellular components were obtained by same method. These cellular components were tried to transformation with the various titers of 5-azacytidine to descript the appropriate concentration of 5-azacytidine and possibility of transformation ability of adipose tissue. Group 1 is abdominal subcutaneous adipose tissue and Group 2 is intra-abdominal adipose tissue-retroperitoneal adipose tissue and omentum. Cellular components were extracted by collagenase and $NH_4Cl$ et al, and these components were cultured by non-induction media - DMEM media containing 10% FBS and inducted by none, $3{\mu}mol/L,\;6{\mu}mol/L,\;and\;9{\mu}mol/L$ 5-azacytidine after the 1st and 2nd subculture. After 4 weeks incubation, tile cell blocks were made, immunostaining was done with the antibodies of CD34, heavy myosin chain, troponin T, and SMA. Result: Immunostaining of the transformed cells for troponin T was positive in the $6{\mu}mol/L\;&\;9{\mu}mol/L$ 5-azacytidine of Group 1 & 2, but CD34 and heavy myosin chain antibodies were negative and SMA antibody was positive in the $3{\mu}mol/L\;&\;6{\mu}mol/L$ 5-azacytidne of Group 2. Conclusion: These observations confirm that adult mesenchymal stem cells isolated from the abdominal subcutaneous adipose tissues and intra-abdominal adipose tissues can be chemically transformed into cardiomyocytes. This can potentially be a source of autologous cells for myocardial repair.

The Actual State and the Utilization for Dental Radiography in Korea (국내 치과방사선의 현황 및 이용 실태)

  • Shin, Gwi-Soon;Kim, You-Hyun;Lee, Bo-Ram;Kim, Se-Young;Lee, Gui-Won;Park, Chang-Seo;Park, Hyok;Chang, Kye-Yong
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.109-120
    • /
    • 2010
  • The purpose of this study was first to analyze the utilization of dental examination through questionnaire to develop a diagnostic reference level of patient doses for dental radiography in korea. 77 dental institutions were classified into three groups: A group for the dental hospitals of the college of dentistry (11 institutions), B group for dental hospitals (30 institutions) and C group for dental clinics (36 institutions). The results were as follows : The mean numbers of unit chairs and medical staffs were 140.2, 15.3 and 5.8 sets, 112.6, 7.3 and 1.7 dentists, 3.1, 0.5 and no one radiologic technologists, and 19.7, 12.5 and 3.3 dental hygienists in A, B and C groups, respectively. The mean numbers of dental X-ray equipments were 14.64, 3.21 and 2.19 in A, B and C groups, respectively. Intraoral dental X-ray unit was used the most, the following equipments were panoramic, cephalometric, and cone-beam CT units. The most used X-ray imaging system was also digital system (above 50%) in all three groups. Insight dental film (Kodak, USA) having high sensitivity was routinely used for periapical radiography. The automatic processor was not used in many dental institutions, but the film-holding device was used in many dental institutions. The utilization rates of PACS in A, B and C groups were 90.9%, 83.3% and 16.7% respectively, and the PACS software program was used the most PiView STAR (Infinitt, Korea). The annual mean number of radiographic cases in one dental institution in 2008 for A group was 6.8 times and 21.2 times more than those for B and C groups, and periapical and panoramic radiographs were taken mostly. Tube voltage (kVp) and tube current (mA) for periapical radiography were similar in all three groups, but exposure time in C group was 12.0 times and 3.5 times longer than those in B and C groups. The amount of radiation exposure in C group, in which dental hygienists take dental radiographs, was more than those in other groups. The exposure parameters for panoramic radiography were similar in all three groups. In conclusion, the exposure parameters in dental radiography should be determined with reference level, not past experiences. Use of automatic processor and film-holding devices reduces the radiation exposure in film system. The quality assurance of dental equipments are necessary for the reduction of the patient dose and the improvement of X-ray image quality.

Information Privacy Concern in Context-Aware Personalized Services: Results of a Delphi Study

  • Lee, Yon-Nim;Kwon, Oh-Byung
    • Asia pacific journal of information systems
    • /
    • v.20 no.2
    • /
    • pp.63-86
    • /
    • 2010
  • Personalized services directly and indirectly acquire personal data, in part, to provide customers with higher-value services that are specifically context-relevant (such as place and time). Information technologies continue to mature and develop, providing greatly improved performance. Sensory networks and intelligent software can now obtain context data, and that is the cornerstone for providing personalized, context-specific services. Yet, the danger of overflowing personal information is increasing because the data retrieved by the sensors usually contains privacy information. Various technical characteristics of context-aware applications have more troubling implications for information privacy. In parallel with increasing use of context for service personalization, information privacy concerns have also increased such as an unrestricted availability of context information. Those privacy concerns are consistently regarded as a critical issue facing context-aware personalized service success. The entire field of information privacy is growing as an important area of research, with many new definitions and terminologies, because of a need for a better understanding of information privacy concepts. Especially, it requires that the factors of information privacy should be revised according to the characteristics of new technologies. However, previous information privacy factors of context-aware applications have at least two shortcomings. First, there has been little overview of the technology characteristics of context-aware computing. Existing studies have only focused on a small subset of the technical characteristics of context-aware computing. Therefore, there has not been a mutually exclusive set of factors that uniquely and completely describe information privacy on context-aware applications. Second, user survey has been widely used to identify factors of information privacy in most studies despite the limitation of users' knowledge and experiences about context-aware computing technology. To date, since context-aware services have not been widely deployed on a commercial scale yet, only very few people have prior experiences with context-aware personalized services. It is difficult to build users' knowledge about context-aware technology even by increasing their understanding in various ways: scenarios, pictures, flash animation, etc. Nevertheless, conducting a survey, assuming that the participants have sufficient experience or understanding about the technologies shown in the survey, may not be absolutely valid. Moreover, some surveys are based solely on simplifying and hence unrealistic assumptions (e.g., they only consider location information as a context data). A better understanding of information privacy concern in context-aware personalized services is highly needed. Hence, the purpose of this paper is to identify a generic set of factors for elemental information privacy concern in context-aware personalized services and to develop a rank-order list of information privacy concern factors. We consider overall technology characteristics to establish a mutually exclusive set of factors. A Delphi survey, a rigorous data collection method, was deployed to obtain a reliable opinion from the experts and to produce a rank-order list. It, therefore, lends itself well to obtaining a set of universal factors of information privacy concern and its priority. An international panel of researchers and practitioners who have the expertise in privacy and context-aware system fields were involved in our research. Delphi rounds formatting will faithfully follow the procedure for the Delphi study proposed by Okoli and Pawlowski. This will involve three general rounds: (1) brainstorming for important factors; (2) narrowing down the original list to the most important ones; and (3) ranking the list of important factors. For this round only, experts were treated as individuals, not panels. Adapted from Okoli and Pawlowski, we outlined the process of administrating the study. We performed three rounds. In the first and second rounds of the Delphi questionnaire, we gathered a set of exclusive factors for information privacy concern in context-aware personalized services. The respondents were asked to provide at least five main factors for the most appropriate understanding of the information privacy concern in the first round. To do so, some of the main factors found in the literature were presented to the participants. The second round of the questionnaire discussed the main factor provided in the first round, fleshed out with relevant sub-factors. Respondents were then requested to evaluate each sub factor's suitability against the corresponding main factors to determine the final sub-factors from the candidate factors. The sub-factors were found from the literature survey. Final factors selected by over 50% of experts. In the third round, a list of factors with corresponding questions was provided, and the respondents were requested to assess the importance of each main factor and its corresponding sub factors. Finally, we calculated the mean rank of each item to make a final result. While analyzing the data, we focused on group consensus rather than individual insistence. To do so, a concordance analysis, which measures the consistency of the experts' responses over successive rounds of the Delphi, was adopted during the survey process. As a result, experts reported that context data collection and high identifiable level of identical data are the most important factor in the main factors and sub factors, respectively. Additional important sub-factors included diverse types of context data collected, tracking and recording functionalities, and embedded and disappeared sensor devices. The average score of each factor is very useful for future context-aware personalized service development in the view of the information privacy. The final factors have the following differences comparing to those proposed in other studies. First, the concern factors differ from existing studies, which are based on privacy issues that may occur during the lifecycle of acquired user information. However, our study helped to clarify these sometimes vague issues by determining which privacy concern issues are viable based on specific technical characteristics in context-aware personalized services. Since a context-aware service differs in its technical characteristics compared to other services, we selected specific characteristics that had a higher potential to increase user's privacy concerns. Secondly, this study considered privacy issues in terms of service delivery and display that were almost overlooked in existing studies by introducing IPOS as the factor division. Lastly, in each factor, it correlated the level of importance with professionals' opinions as to what extent users have privacy concerns. The reason that it did not select the traditional method questionnaire at that time is that context-aware personalized service considered the absolute lack in understanding and experience of users with new technology. For understanding users' privacy concerns, professionals in the Delphi questionnaire process selected context data collection, tracking and recording, and sensory network as the most important factors among technological characteristics of context-aware personalized services. In the creation of a context-aware personalized services, this study demonstrates the importance and relevance of determining an optimal methodology, and which technologies and in what sequence are needed, to acquire what types of users' context information. Most studies focus on which services and systems should be provided and developed by utilizing context information on the supposition, along with the development of context-aware technology. However, the results in this study show that, in terms of users' privacy, it is necessary to pay greater attention to the activities that acquire context information. To inspect the results in the evaluation of sub factor, additional studies would be necessary for approaches on reducing users' privacy concerns toward technological characteristics such as highly identifiable level of identical data, diverse types of context data collected, tracking and recording functionality, embedded and disappearing sensor devices. The factor ranked the next highest level of importance after input is a context-aware service delivery that is related to output. The results show that delivery and display showing services to users in a context-aware personalized services toward the anywhere-anytime-any device concept have been regarded as even more important than in previous computing environment. Considering the concern factors to develop context aware personalized services will help to increase service success rate and hopefully user acceptance for those services. Our future work will be to adopt these factors for qualifying context aware service development projects such as u-city development projects in terms of service quality and hence user acceptance.

An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration (예측 불가능한 호흡 변화에 따른 사이버나이프 종양 추적 방사선 치료의 정확도 분석)

  • Seo, jung min;Lee, chang yeol;Huh, hyun do;Kim, wan sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.157-166
    • /
    • 2015
  • Purpose : Cyber-Knife tumor tracking system, based on the correlation relationship between the position of a tumor which moves in response to the real time respiratory cycle signal and respiration was obtained by the LED marker attached to the outside of the patient, the location of the tumor to predict in advance, the movement of the tumor in synchronization with the therapeutic device to track real-time tumor, is a system for treating. The purpose of this study, in the cyber knife tumor tracking radiation therapy, trying to evaluate the accuracy of tumor tracking radiation therapy system due to the change in the form of unpredictable sudden breathing due to cough and sleep. Materials and Methods : Breathing Log files that were used in the study, based on the Respiratory gating radiotherapy and Cyber-knife tracking radiosurgery breathing Log files of patients who received herein, measured using the Log files in the form of a Sinusoidal pattern and Sudden change pattern. it has been reconstituted as possible. Enter the reconstructed respiratory Log file cyber knife dynamic chest Phantom, so that it is possible to implement a motion due to respiration, add manufacturing the driving apparatus of the existing dynamic chest Phantom, Phantom the form of respiration we have developed a program that can be applied to. Movement of the phantom inside the target (Ball cube target) was driven by the displacement of three sizes of according to the size of the respiratory vertical (Superior-Inferior) direction to the 5 mm, 10 mm, 20 mm. Insert crosses two EBT3 films in phantom inside the target in response to changes in the target movement, the End-to-End (E2E) test provided in Cyber-Knife manufacturer depending on the form of the breathing five times each. It was determined by carrying. Accuracy of tumor tracking system is indicated by the target error by analyzing the inserted film, additional E2E test is analyzed by measuring the correlation error while being advanced. Results : If the target error is a sine curve breathing form, the size of the target of the movement is in response to the 5 mm, 10 mm, 20 mm, respectively, of the average $1.14{\pm}0.13mm$, $1.05{\pm}0.20mm$, with $2.37{\pm}0.17mm$, suddenly for it is variations in breathing, respective average $1.87{\pm}0.19mm$, $2.15{\pm}0.21mm$, and analyzed with $2.44{\pm}0.26mm$. If the correlation error can be defined by the length of the displacement vector in the target track is a sinusoidal breathing mode, the size of the target of the movement in response to 5 mm, 10 mm, 20 mm, respective average $0.84{\pm}0.01mm$, $0.70{\pm}0.13mm$, with $1.63{\pm}0.10mm$, if it is a variant of sudden breathing respective average $0.97{\pm}0.06mm$, $1.44{\pm}0.11mm$, and analyzed with $1.98{\pm}0.10mm$. The larger the correlation error values in both the both the respiratory form, the target error value is large. If the motion size of the target of the sine curve breathing form is greater than or equal to 20 mm, was measured at 1.5 mm or more is a recommendation value of both cyber knife manufacturer of both error value. Conclusion : There is a tendency that the correlation error value between about target error value magnitude of the target motion is large is increased, the error value becomes large in variation of rapid respiration than breathing the form of a sine curve. The more the shape of the breathing large movements regular shape of sine curves target accuracy of the tumor tracking system can be judged to be reduced. Using the algorithm of Cyber-Knife tumor tracking system, when there is a change in the sudden unpredictable respiratory due patient coughing during treatment enforcement is to stop the treatment, it is assumed to carry out the internal target validation process again, it is necessary to readjust the form of respiration. Patients under treatment is determined to be able to improve the treatment of accuracy to induce the observed form of regular breathing and put like to see the goggles monitor capable of the respiratory form of the person.

  • PDF

Role, Change, Job Satisfaction and Obstacles in Carrying out the Role of Public Health Nurses in Health Center (보건소 보건간호사의 역할변화, 역할수행의 장애요인과 만족도)

  • Ahn, Kyeong-Sook;Jung, Moon-Sook
    • Journal of agricultural medicine and community health
    • /
    • v.20 no.1
    • /
    • pp.1-13
    • /
    • 1995
  • Based on the questionnaires sent to 270 nurses of public health centers in kyungnam during the period of March 19 to April 11 in 1992, this study was written for the of finding out the grade of satisfaction, obstacles in carrying out duties concerned with nursing services and the change of nurses role needed according to the change of the local public health administration. The first-ranking tasks carried by nurses of public health center are believed to have been family planning activities before the 1970's, nursing services during the 1970's, mother-child health activities during the 1980's, and nursing services during the period of 1990 to 1992. As far as the priority order of all the family planning activities is concerned, the counseling of the insertion of intrauterine contraceptive device, the use of oral pill or the distribution of condom was placed emphasis on before 1970, and publicity activities of family planning after that time. The first priority order of mother-child health activities has been put on the registration of pregnant women since 1970, with prenatal examination and vaccination ranking next to it. The priority order for activities against tuberculosis was laid on finding out and registration of new T.B. patients every year, with patients' control, and medication or injection ranking next to it. As for the priority order of nursing services, traveling medical examination and treatment ranked the first-stressed activity before 1970, with medication and injection ranking next to it. The first priority order management activity of communicable diseases was put on vaccination before 1970, with medication and injection. ranking next. And consultation and education ranked second to it during 1990 to 1992. As for the health services of the aged, traveling examination and treatment ranked the order, with the assistance of medical examination ranking next to it. As far as troubles and obstacles shown in case of family planning, the rate of residents' lack understanding was 28.8%, that of lacking budget 13.6%, and the imperfection of public health administration system 11.9%. In the case of tuberculosis control, residents' lacking understanding was 32.5%, the deficiency of public health administration system 18.2%, over-duty(shortage of hands) 15.6%, and the insufficiency skill and know-how 13.0%. In the case of nursing services, the deficiency of public health administration system was 18.2%, each over-duty(the shortage of hands) and the shortage of facilities and equipment 15.6% respective, and residents' lacking understanding 13.0%. The rate of dissatisfaction with the chance or possibility of promotion for his or her career or capability was shown to be 49.2%, and 65.9% of the health nurses expressed their complaints of the deficiency of the chance of the promotion to a professional or expert. when the public health nurses were asked in the questionably whether they were satisfied or not with current state of equipment and facilities needed for public health service, 49.6% of them answered in the negative. The grade of the satisfaction with the current individual position was shown to be low as much as the status of his or her position was now. 37.6% of those asked in the research answered to have the readiness to switch jobs for the reasons of dissatisfaction and so on with lacking promotion chance as well as bad working condition. Significant correlation between the grade of job satisfaction and the current status of the po as found to be in this research, which showed that the lower the status of position was, the lower the grade of job satisfaction was. But little correlation between the grade of job satisfaction and his or her schooling and career was found. In order to carry out primary health care successfully, it can be said that more education and publicity activities to make public health nurses and residents see it in a new light are requested. In addition to it, it is suggested that the improvement of promotion system for public health nurses and the enlargement of job province should also be taken in consideration of the high dissatisfaction with and complaints of the chance of promotion and the system of position. In order words, it is important that considerations for system improvement enough to make nursing services pleasant and satisfactory should be taken into.

  • PDF

Standard Chemotherapy with Excluding Isoniazid in a Murine Model of Tuberculosis (마우스 결핵 모델에서 Isoniazid를 제외한 표준치료의 예비 연구)

  • Shim, Tae Sun;Lee, Eun Gae;Choi, Chang Min;Hong, Sang-Bum;Oh, Yeon-Mok;Lim, Chae-Man;Lee, Sang Do;Koh, Younsuck;Kim, Woo Sung;Kim, Dong Soon;Cho, Sang-Nae;Kim, Won Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.3
    • /
    • pp.177-182
    • /
    • 2008
  • Background: Isoniazid (INH, H) is a key drug of the standard first-line regimen for the treatment of tuberculosis (TB), yet some reports have suggested that treatment efficacy was maintained even though INH was omitted from the treatment regimen. Methods: One hundred forty C57BL/6 mice were infected with the H37Rv strain of M. tuberculosis with using a Glas-Col aerosol generation device, and this resulted in depositing about 100 bacilli in the lung. Four weeks after infection, anti-TB treatment was initiated with varying regimens for 4-8 weeks; Group 1: no treatment (control), Group 2 (4HREZ): 4 weeks of INH, rifampicin (R), pyrazinamide (Z) and ethambutol (E), Group 3: 1HREZ/3REZ, Group 4: 4REZ, Group 5: 4HREZ/4HRE, Group 6: 1HREZ/3REZ/4RE, and Group 7: 4REZ/4RE. The lungs and spleens were harvested at several time points until 28 weeks after infection, and the colony-forming unit (CFU) counts were determined. Results: The CFU counts increased steadily after infection in the control group. In the 4-week treatment groups (Group 2-4), even though the culture was negative at treatment completion, the bacilli grew again at the 12-week and 20-week time points after completion of treatment. In the 8-week treatment groups (Groups 5-7), the bacilli did not grow in the lung at 4 weeks after treatment initiation and thereafter. In the spleens of Group 7 in which INH was omitted from the treatment regimen, the culture was negative at 4-weeks after treatment initiation and thereafter. However, in Groups 5 and 6 in which INH was taken continuously or intermittently, the bacilli grew in the spleen at some time points after completion of treatment. Conclusion: TThe exclusion of INH from the standard first-line regimen did not affect the treatment outcome in a murine model of TB in the early stage of disease. Further studies using a murine model of chronic TB are necessary to clarify the role of INH in the standard first-line regimen for treating TB.