• Title/Summary/Keyword: Device-to-Device

Search Result 25,316, Processing Time 0.047 seconds

Device for Assisting Grasping Function (2nd Report : Maneuverability Evaluation)

  • Moromugi, S.;Okamoto, A.;Kim, S.H.;Tanaka, H.;Ishimatsu, T.;Koujina, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2665-2669
    • /
    • 2003
  • A wearable device to assist fingering function for disabled is developed in this study. This is the second paper to report the progress in development of this assisting device. The device is developed for a patient who suffers from cervical spinal cord injury. In the first paper, it was reported that the patient could successfully pick up several types of objects with his paralyzed fingers by using this device. As a next step, the maneuverability of the device under grasping operation is discussed in this paper. Maneuverability of the system is experimentally evaluated. The dexterity in controlling finger force is compared between the cases that non-disabled examinees operate their finger with inherent abilities and that a disabled examinee operates his finger by using the assisting device.

  • PDF

Development of New LTPS Process

  • Yi, Chung;Park, Kyung-Min;Choi, Pil-Mo;Kim, Ung-Sik;Kim, Dong-Byum;Kim, Chi-Woo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1024-1026
    • /
    • 2004
  • We have developed the five mask $PMOS^1$ and the six mask CMOS process architecture for poly-Si TFT. In order to have a competitive process with that for a-Si TFT, the simple co-planar electrode structure whose data line electrode and pixel electrode are on the same plane was adopted. In addition, RGB + White four color $technology^2$ were applied to achieve high aperture ratio and transmittance. Using the aforementioned process architecture and four color technology, 2.0 inch qCIF transmissive micro-reflectance (TMR) device was successfully fabricated.

  • PDF

Inter-operation between the mobile device and external device (모바일 단말과 외부 장치 모듈과의 자동 연동 시스템)

  • Kim, Sang-Tae;Kim, Hyun-Deok;Park, Won-Kyu;Park, Yoon-Jung;Kim, Young-Cheol;Jung, Youn-Wha;Kim, Won-Gi;Park, Hong-Bae
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.705-706
    • /
    • 2006
  • A novel plug and play system for a mobile device has been proposed and demonstrated to provide an easy inter-operation between the mobile device and external modules. It supports an automatic installation and execution of the device drivers stored in the external modules into the mobile devices when the external module is connected to the mobile device. It also enables an automatic removal of the derivers when the external module is disconnected from the mobile device, which makes the user use the resource of the mobile devices more efficiently.

  • PDF

ECR device impedance matching circuit design (ECR장치의 임피던스 매칭회로 설계)

  • KIM, Sung-Wan;KIM, Chang-Sun
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.445-446
    • /
    • 2012
  • Recently the interest in wireless power transfer have been studied. ECR (Electromagnetic Coupled Resonance) device, depending on the size of the frequency characteristics of the structure, increasing in volume and larger volume of wireless power transmission device to make use of ECR is a big barrier. So to solve this problem for ECR device miniaturization and high efficiency has been actively studied. In this paper, the size of the device for ECR IM (Impedance Matching) by applying a one-turn coil circuit, remove the device in the form of ECR Network Analyzer measured by removing the one-turn coil has demonstrated the possibility of the device in the form of ECR.

  • PDF

Static and Dynamic Characteristics of PT-IGBT by Proton Irradiation (양성자 주입 조건에 따른 PT-IGBT의 정특성 및 동특성 분석)

  • Choi, Sung-Hwan;Lee, Yong-Hyun;Bae, Young-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.14-15
    • /
    • 2007
  • Proton irradiation technology was used for improvement of switching characteristics of the PT-IGBT. The proton irradiation was carried out at 5.56 MeV energy from the back side of processed wafers and at 2.39 MeV energy from the front side of the wafers. The on-state and off-state I-V characteristics and switching properties of the device were analyzed and compared with those of un-irradiated device and e-beam irradiated device which was conventional method for minority carrier lifetime reduction. The proton irradiated device by 5.56 MeV energy was superior to e-beam irradiated device for the on-state and off-state I-V characteristics, nevertheless turn-off time of proton irradiated device was superior to that of the e-beam irradiated device.

  • PDF

Slide-show of Panoramic Image through a Secondary Device by using MPEG-4 LASeR PMSI (MPEG-4 LASeR PMSI를 활용한 Secondary Device 기반 파노라믹 영상 슬라이드 쇼 재생 기술)

  • Park, Yongchul;Kim, Kyuheon
    • Journal of Broadcast Engineering
    • /
    • v.17 no.6
    • /
    • pp.1014-1028
    • /
    • 2012
  • Recently, N-screen service and secondary device have gotten an attention from public. Also, we can experience N-screen service through various digital devices. N-screen means multimedia technology which can seamlessly consume multimedia content. Secondary device means auxiliary multimedia device which can consume content related to main content through adjunct connection to main device. Not only be electronic manufactures interested in N-screen technology and services but also digital devices applied for N-screen have been released. But it has limitation that user can only consume content to be purchased from content company server not device of user. This paper proposes the system that composes effective and various N-screen multimedia service through MPEG-4 LASeR (Lightweight Application Scene Representation) PMSI (Presentation and Modification of Structured Information) as international standard technology which can provide scene description including many instruction for dynamic update of scene.

Discovery of Proximate Devices with Partial Information for Device-to-Device Communication Systems (디바이스 간 직접통신 시스템을 위한 부분 정보를 이용한 근거리 디바이스 발견)

  • Yeo, Gyu-Hak;Chae, Seung-Yeob;Rim, Min-Joong;Kang, Chung G.;Yeh, Choong-Il;Ahn, Jae-Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.5
    • /
    • pp.328-336
    • /
    • 2013
  • One of the important processes in device-to-device communication is the discovery of proximate devices. In order to perform precise discovery of devices, the distance information among all the device pairs should be gathered by each device sending a discovery signal in turn and the other devices receiving the signal. However, periodic discovery signal transmission by every device might require too long discovery period or too large resource for discovery. Above all, some discovery information might be lost due to several practical reasons and it may take substantial amount of time to obtain all the necessary information. In this paper, we propose a proximate-device-discovery method using partial discovery information in order to reduce the resource for discovery and support the cases in which some discovery information can be lost. We also discuss discovery probabilities with partial discovery information.

Development of a Femur Neck Bone Mineral Density Measuring Device for Accurate Examination

  • Han, Man-Seok;Seo, Sun-youl;Kim, Yong-Kyun;Jeon, Min-Cheol;Lee, Hyun-kuk;Yoo, Se-Jong
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.298-302
    • /
    • 2016
  • In bone density examinations, a change in the measured BMD occurs owing to the differences between the measured areas. To address this problem, we aimed to develop a new auxiliary device that could be rotated by $15^{\circ}$ by fixing the ankle to the distal femur neck. Dual energy X-ray absorptiometry (DXA) of BMD examinations were performed once a year, but 10 patients were examined over three sessions to analyze the area for measuring the femur neck BMD. The goal of this test was to determine the device's reliability, and the results were expressed in terms of the standard deviation of measurements. After performing bone density measurements using the new auxiliary device on 10 normal patients, with three measurements for each patient, the obtained standard deviation was 0.03. The standard deviation of the measured BMD was 0.19 when using the currently existing auxiliary device, while the standard deviation of the measured BMD was 0.03 when using the new auxiliary device. By using the new auxiliary device, the standard deviation could be reduced by ~80%. Accurate rotation of the femur neck was possible in all examinations, and the standard deviation of BMD measurements could be reduced by up to 80% compared with the measurements performed using the currently existing auxiliary device. We hope that this advantageous new design can be used as a standard auxiliary device for measuring the femur neck BMD.

A study on imaging device sensor data QC (영상장치 센서 데이터 QC에 관한 연구)

  • Dong-Min Yun;Jae-Yeong Lee;Sung-Sik Park;Yong-Han Jeon
    • Design & Manufacturing
    • /
    • v.16 no.4
    • /
    • pp.52-59
    • /
    • 2022
  • Currently, Korea is an aging society and is expected to become a super-aged society in about four years. X-ray devices are widely used for early diagnosis in hospitals, and many X-ray technologies are being developed. The development of X-ray device technology is important, but it is also important to increase the reliability of the device through accurate data management. Sensor nodes such as temperature, voltage, and current of the diagnosis device may malfunction or transmit inaccurate data due to various causes such as failure or power outage. Therefore, in this study, the temperature, tube voltage, and tube current data related to each sensor and detection circuit of the diagnostic X-ray imaging device were measured and analyzed. Based on QC data, device failure prediction and diagnosis algorithms were designed and performed. The fault diagnosis algorithm can configure a simulator capable of setting user parameter values, displaying sensor output graphs, and displaying signs of sensor abnormalities, and can check the detection results when each sensor is operating normally and when the sensor is abnormal. It is judged that efficient device management and diagnosis is possible because it monitors abnormal data values (temperature, voltage, current) in real time and automatically diagnoses failures by feeding back the abnormal values detected at each stage. Although this algorithm cannot predict all failures related to temperature, voltage, and current of diagnostic X-ray imaging devices, it can detect temperature rise, bouncing values, device physical limits, input/output values, and radiation-related anomalies. exposure. If a value exceeding the maximum variation value of each data occurs, it is judged that it will be possible to check and respond in preparation for device failure. If a device's sensor fails, unexpected accidents may occur, increasing costs and risks, and regular maintenance cannot cope with all errors or failures. Therefore, since real-time maintenance through continuous data monitoring is possible, reliability improvement, maintenance cost reduction, and efficient management of equipment are expected to be possible.

Development of the Pointing Device using EOG (EOG를 이용한 포인팅 디바이스의 개발)

  • Park, Hyoung-Joon;Park, Jong-Hwan;Chun, Woo-Young
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1356-1363
    • /
    • 1999
  • In this paper, a new method for controlling the pointing device using EOG(electrooculogram) signal generated from eye movement was suggested. The basic idea of the method is to control the direction of pointer, as using the results of measuring each component of the horizontal EOG and the vertical EOG by angle of eye-gaze. As a practical example, pointing device controlling the personal computer's pointer is manufactured. The designed pointing device consists of pre-amplifier, A/D converter, serial transmission device and PC program. That is, first, the EOG is amplified by pre-amplifier. Secondly, the amplified EOG is digitized and transmitted to personal computer by PIC16C74A. Finally, the software for controlling the pointer on personal computer is programed. As the result, the measured horizontal EOG and vertical EOG by eye-gaze angle had high linearity; the correlation coefficients of the regression line were 0.998 and 0.996 respectively. And the developed pointing device is able to control the personal computer's pointer, and the average of the errors between the objective value and the observed value had 3.77% for horizontal axis and 5.85% for vertical axis. The pointing device developed in this study is able to control personal computer's pointer by subject's eye movement, that is, the user's intention. Furthermore, the algorithm of this study is applicable for many field, such as a new method remote control, a new wheelchair control and so forth.

  • PDF