• Title/Summary/Keyword: Device-free

Search Result 667, Processing Time 0.025 seconds

Development of the Dot Sight Device by Using the Doublet Reflector (Doublet 반사경을 이용한 도트 사이트 장치의 개발)

  • Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.65-69
    • /
    • 2008
  • Purpose: To develop a dot sight device for a sighting shot using the doublet reflector. Methods: We designed the singlet reflector and the doublet reflector by Sigma 2000 program and compared the one to the other. Results: In analysis of finite ray aberration, we could confirm that it has the effective field of view with the free-parallax which is 3.3 times wider than the existing dot sight device using the singlet reflector. If you use the doublet reflector, the central thickness of optical system become more than two times bigger than the existing one. As a result, when the image of a target object is made on the observer's retina, if you make the first side's radius of curvature equal with the second one as the case of the singlet reflector, changes in magnification are appeared. To conquer this problem, we had to make be satisfied with the afocal condition in the case of doublet reflector. Conclusions: we could develop the dot sight device for a sighting shot using the doublet reflector which has the effective field of view with the free-parallax which is 3.3 times wider than the existing dot sight device using the singlet reflector.

  • PDF

Uniaxial Magnetic Anistotropy of a NiO-Spin Valve Device

  • Lee, Won-Hyung;Hwang, Do-Guwn;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.14 no.1
    • /
    • pp.18-22
    • /
    • 2009
  • The shape anisotropy effect of a giant magnetoresistance-spin valves (GMR-SV) device with a glass/NiO/NiFe/CoFe/Cu/CoFe/NiFe layered structure for use in the detection of magnetic property of molecules within a cell was investigated. The patterned device was given uniaxial anisotropy during the sputtering deposition and vacuum post-annealing, which was performed at $200^{\circ}C$ under a 300 Oe magnetic field. The pattern size of the device, which was prepared through the photolithography process, was $2{\times}15\;{\mu}m^2$. The experimental results confirmed that the best design for a GMR-SV device to be used as a biosensor is to have both the axis sensing current and the easy axis of the pinned NiO/NiFe/CoFe triple layer oriented in the direction of the device's width, while the easy axis of the free CoFe/NiFe bilayer should be pointed along the long axis of the device.

Numerical Study of Fluidic Device in APR1400 Using Free-Surface Model (자유수면모델을 활용한 APR1400 유량조절장치의 수치해석 연구)

  • Lim, Sang-Gyu;You, Sung-Chang;Kim, Han-Gon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.7
    • /
    • pp.767-774
    • /
    • 2012
  • A fluidic device (FD) has been adopted in the safety injection tanks (SITs) of APR1400. A flow control mechanism of the FD was used to vary the flow regime in the vortex chamber corresponding to the SITs water level. The flow regime in the vortex chamber has a different pressure loss from low to high in accordance with the SITs water level. Nitrogen at the top of the SIT could be released owing to inertia of discharge flow when changing from a high flow rate to a low flow rate. This phenomenon is important to design improvement perspective because it can affect the performance of the FD. This paper shows a result of a preliminary numerical study to obtain the transient data related to air release in the flow turn-down period using a two-fluid free-surface model provided from ANSYS CFX 13.0. In conclusion, there is no significant effect on the performance of the FD, though a small quantity of air is released during the flow turn-down period.

Design Adaptive Acoustic Echo Canceller for AVRCP Bluetooth Hands Free (AVRCP 기반의 블루투스 핸즈프리를 위한 음향반향제거기 설계)

  • Jung, Yong-Gyu;Kim, Kyeong-Woong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.4
    • /
    • pp.33-38
    • /
    • 2009
  • Recently most of A/V devices are being adopted hi-tech of A VRCP and changed to mobile environment. AVRCP is designed to provide a standard interface to control A/V devices, hi-fi equipment, or others to allow a single remote control or other device to control all the A/V equipment to which a user has access. It may be used in concert with A2DP or VDP. The AVRCP defines two roles, that of a controller and target device. In AVRCP, the controller translates the detected user action to the A/V control signal, and then transmits it to a remote Bluetooth enabled device. It can be small and mixed mobile devices using bluetooth technologies. The functions available for a conventional infrared remote controller can be realized in this protocol. The remote control described in this protocol is designed specifically for A/V control only. We designed new DSP using Adaptive Acoustic Echo Canceller for bluetooth hands free based this AVRCP standard specifications.

  • PDF

Blazed $GxL^{TM}$ Device for Laser Dream Theater at the Aichi Expo 2005

  • Ito, Yasuyuki;Saruta, Kunihiko;Kasai, Hiroto;Nishida, Masato;Yamaguchi, Masanari;Yamashita, Keitaro;Taguchi, Ayumu;Oniki, Kazunao;Tamada, Hitoshi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.556-559
    • /
    • 2006
  • We successfully developed a high performance and highly reliable blazed GxL device with a high optical efficiency and a high contrast ratio. The device demonstrated superior resistance against a high power laser, which is suitable for a large-area laser projector. We operated the world's largest laser projection screen using this device at the 2005 World Exposition in Aichi, Japan, problem free.

  • PDF

A Non-contact Two-Dimensional Position Sensing Device Using Electromagnetic Induction (전자기 유도 방식을 이용한 비접촉식 2차원 위치 센서)

  • Ryu, Young-Kee;Koh, Kuk-Won;Kim, Hak-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.11
    • /
    • pp.1159-1163
    • /
    • 2012
  • In this paper, we would like to introduce two dimensional non-contact position sensor by using an electromagnetic induction based coil system and an algorithm to estimate the position of pointer. The sensor which will introduce in this paper is composed of a pointer including LC resonant circuit and a sensor board to detect the electromagnetic signal from the pointer. Because of the simplicity shape of the line antenna, low cost and free form curved shape of the sensor device is possible. In this research, we proposed a new two dimensional non-contact type electromagnetic sensor system and realized the proposed sensor device. From the experiments, the proposed device can be employed for the two dimensional position sensor.

Compact See-though Near to Eye Display with Diffractive Optical Elements

  • Levola, Tapani
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1749-1752
    • /
    • 2007
  • The Near to Eye Display (NED) solves the problem of having a display larger than a small portable device. The virtual image of the NED is created using a microdisplay and imaging optics. It is important that the optics does not interfere with the human visual system and that the device is light, compact and easy to wear. In this paper the principles of a biocular NED, which is based on a novel diffractive Exit Pupil Expander (EPE), are presented. The optical system is compact and intrinsically free from distortions and misalignments.

  • PDF

A New Mail Survey Method for Sensitive Character without Using Randomization Device

  • Ki Hak Hong
    • Communications for Statistical Applications and Methods
    • /
    • v.4 no.3
    • /
    • pp.735-741
    • /
    • 1997
  • In the present paper, we propose a new randomization device free mail survey method. The estimator based on proposed model is unbiased and more efficient than the estimator based on SIngh, Mangat and Singh model (SMS-model)(1993) when $\pi$<1/2, and more protective than SMS-model in view of the protection of privacy regardless of the values of $\pi$ and $\pi_Y$ only if we count the number of say 'Yes' from the respondents. However, If we consider the respondents that say 'No', the SMS-model is more protective than our model.

  • PDF

InP JFET Devices for High Speed Switching Application (광대역 교환을 위한 InP JFET소자)

  • 지윤규;김성준;정종민
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.28A no.5
    • /
    • pp.370-374
    • /
    • 1991
  • A high performance fully ion-implanted InP JFET was characterized for high speed switching elements. The switch has an insertion loss of 5.5dB with 31.6dB isolation at 1GHz. This device can effectively swithc a byte-multiplexed 2Gb/s signal and an eye-diagram taken at 2Gb/s shows an error-free eye pattern. Therefore, this device can be used as a switching element for high transmission data rate for monolithic integration of optoelectronic circuit in the long-wavelength region.

  • PDF