• Title/Summary/Keyword: Device design

Search Result 6,053, Processing Time 0.036 seconds

A Study on Optimal Operation Conditions for an Electronic Device Alignment System by Using Design of Experiments (실험계획법을 이용한 전자부품 위치정렬장치 최적 운영조건 사례연구)

  • Lee, Dong Heon;Lee, Mi Lim;Bae, Suk Joo
    • Journal of Korean Society for Quality Management
    • /
    • v.43 no.3
    • /
    • pp.453-466
    • /
    • 2015
  • Purpose: The purpose of this study is to design a systematic method to estimate optimal operation conditions of design variables for an electronic device alignment system. Method: The 2-level factorial design and the central composite design are used in order to plan experiments. Based on the experiment results, a regression model is established to find optimal conditions for the design variables. Results: 3 of 5 design variables are selected as major factors that affect the alignment system significantly. The optimized condition for each variable is estimated by using a sequential experiment plan and a quadratic regression model. Conclusion: The method designed in this study provides an efficient and systematic plan to select the optimized operation condition for the design variables. The method is expected to improve inspection accuracy of the system and reduce the development cost and period.

Design of broadband low noise balanced amplifier (광대역 저잡음 평형 증폭기 설계)

  • 이정란;문성익;양두영
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.191-194
    • /
    • 1999
  • The balanced amplifier is a practical amplifier to, implement a broadband amplifier that has flat gain and good input and output VSWR. Three-stage amplifier design procedure usually divided into three partition satisfying the following requirements : low noise figure, high gain and high power output. FHX35LG HEMT device is used in the design can be obtained low noise figure at the first-stage, MGA82563 MMIC device is used in the design can be maintained high gain at the second-stage, and AHI MMIC device is used in the design can be required high power output at the third-stage. The results of three-stage balanced amplifier show that power gain is about 40㏈, noise figure is less than 1.2㏈ at operating frequency.

  • PDF

The Improvement of Performance in an Ultra small Camera Iris-Shutter Device using Topology Optimization (최적화 기법을 사용한 초소형 카메라 조리개 셔터장치의 성능향상)

  • Park, Soon-Ok;Yoo, Jeong-Hoon
    • Transactions of the Society of Information Storage Systems
    • /
    • v.5 no.2
    • /
    • pp.53-57
    • /
    • 2009
  • This study is concerned with the design of a camera iris-shutter device for producing force. The camera iris-shutter with yoke should have a smaller size and a bigger magnetic force than the previous model. Since the induced magnetic force operates shutter movement, the magnetic force maximization for a given input current is an important issue. To achieve the goal, new system is designed by the topology optimization method. The design is refined through the design of experiments to find the detail camera iris shutter design satisfying design constraints.

  • PDF

Optimal Design of Grid Cathode Structure in Spherically Convergent Beam Fusion Device (구형 집속 빔 핵융합 장치에서 그리드 음극 구조의 최적 설계)

  • Ju, Heung-Jin;Park, Jeong-Ho;Hwang, Hwui-Dong;Choi, Seung-Kil;Ko, Kwang-Cheol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.4
    • /
    • pp.381-387
    • /
    • 2008
  • Neutron production rate in spherically convergent beam fusion(SCBF) device as a portable neutron source strongly depends on the ion current and the grid cathode structure. In this paper, as the process of design and analysis, Design of Experiment(DOE) based on the results by Finite Element Method-Flux Corrected Transport(FEM-FCT) method is employed to calculate the ion current. This method is very useful to find optimal design conditions in a short time. Number of rings, radius of rings, and distance between the grid cathode and center are selected as control factors. From the results in the optimized model, the higher ion current is calculated and deeper potential well is also observed.

Design Development Process for Clothing of Upper Limb Assistive Wearable Soft Robot (상지 보조 소프트로봇의 의복화를 위한 디자인 개발 프로세스)

  • Hong, Yuhwa;Park, Juyeon;Nam, Yun Ja;Park, Daegeun;Cho, Kyu-Jin;Kim, Youn Joo
    • Fashion & Textile Research Journal
    • /
    • v.23 no.1
    • /
    • pp.106-117
    • /
    • 2021
  • This study proposes a design process for an upper limb assistive wearable soft robot that will enable the development of a clothing product for an upper limb assistive soft robot. A soft robot made of a flexible and soft material that compensates for the shortcomings of existing upper limb muscle strength assistive devices is being developed. Consequently, a clothing process of the upper limb assistive soft robot is required to increase the possibility of wearing such a device. The design process of the upper limb auxiliary soft robot is presented as follows. User analysis and required performance deduction-Soft robot design-upper limb assistive wearable soft robot prototype design and production-evaluation. After designing the clothing according to the design process, the design was revised and supplemented repeatedly according to the results of the clothing evaluation. In the post-production evaluation stage, the first and second prototypes were attached to actual subjects, and the second prototype showed better results. The developed soft robot evaluated if the functionality as a clothing function and the functionality as the utility of the device were harmonized. The convergence study utilized a process of reducing friction conducted through an understanding and cooperation between research fields. The results of this study can be used as basic data to establish the direction of prototype development in fusion research.

Fabrication of high-frequency therapy device for deep part and temperature distribution characteristic according to electrode condition of RET (심부투열용 고주파 치료기의 제작과 RET 전극조건에 따른 온도 분포 특성)

  • Jung, Jae-Won;Kim, Beong-Ju;Kim, Ki-Seon
    • Journal of Advanced Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.267-271
    • /
    • 2018
  • A high-frequency therapy device with improved output by modifying a high-frequency stimulator was fabricated. The details of the design include generating part design, high-frequency transformer design, large output FET installation, DC voltage input part design and gate input driver design. Based on the real test using the pork meat, the temperature distributions according to the current electric transfer method, penetration depth, electrode diameter size were measured. In the CET method, the penetration depth was 0.5 cm and in the RET method, the penetration depth was 20 cm or more. In addition, it was confirmed that the temperature rise according to the penetration depth in the RET system was substantially constant, and the temperature rise was remarkable as the electrode diameter was small. As a result, it has been confirmed that the high frequency therapy device is highly affected by various conditions of the electrode.

A Design of Device Management System for Factories using Wireless Sensor Network (무선 센서 망을 이용한 공장 내 장치 관리 시스템 설계)

  • Moon, Sung-Nam;Kim, Young-Han
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.3C
    • /
    • pp.233-240
    • /
    • 2012
  • Unlike traditional factory environment, in an industrial factory network applied wireless sensor network technologies, all procedures of discovery, identification and verification of devices should be performed in an automatic fashion. To address these challenges, we design a management system using the device registry server that we propose in this paper. In the phase of device discovery, the proposed system utilizes properties of routing protocol running in factories. Also, in the phase of identification and verification, the system uses unique and general information of a device stored within the device registration server. Such a way allows management system to reduce implementation complexity and to easily manage devices in a factory applied with a wireless network consisting of heterogeneous devices.

A Study on the Calibration of GaAs-based 0.1-$\mu\textrm{m}$ $\Gamma$-gate MHEMT DC/RF Characteristics for the Development and Fabrication of over-100-GHz Millimeter-wave HEMT devices (100GHz 이상의 밀리미터파 HEMT 소 제작 및 개발을 위한 GaAs기반 0.1$\mu\textrm{m}$ $\Gamma$-게이트MHEMT의 DC/RF 특성에 대한 calibration 연구)

  • 손명식;이복형;이진구
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.751-754
    • /
    • 2003
  • Metamorphic HEMTs (MHEMTs) have emerged as excellent challenges for the design and fabrication of high-speed HEMTs for millimeter-wave applications. Some of improvements result from improved mobility and larger conduction band discontinuity in the channel, leading to more efficient modulation doping, better confinement, and better device performance compared with pseudomorphic HEMTs. We have studied the calibration on the DC and RF characteristics of the MHEMT device using I $n_{0.53}$G $a_{0.47}$As/I $n_{0.52}$A1$_{0.48}$As modulation-doped heterostructure on the GaAs wafer. For the optimized device performance simulation, we calibrated the device performance of 0.1-${\mu}{\textrm}{m}$ $\Gamma$-gate MHEMT fabricated in our research center using the 2D ISE-DESSIS device simulator. With this calibrated parameter set, we have obtained very good reproducibility. The device simulation on the DC and RF characteristics exhibits good reproducibility for our 0.1-${\mu}{\textrm}{m}$ -gate MHEMT device compared with the measurements. We expect that our calibration result can help design over-100-GHz MHEMT devices for better device performance.ormance.

  • PDF

A Study on the Color Usability of Lumino Haptic Device (루미노 햅틱 디바이스의 색상 사용성 연구)

  • Lee, Sang-Jin;Kim, Byeong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.1
    • /
    • pp.21-26
    • /
    • 2012
  • Haptic device is regarded as the human machine interface technology for easier, more accurate, and intuitive operation. The purpose of this study is to define driver's affection on the haptic device in terms of its design factor : the color of haptic lighting as independent factor. This paper is studied to improve the cognitive ability of existing vehicle haptic device used by only a tactile feedback. On the color feedback usability evaluation, the lmino haptic device is used by adding color feedback to the existing vehicle haptic device. The emotional factor that driver has on the haptic device is extracted by the sensibility analysis. As a result, it is possible to suggest the design direction that satisfies the driver.

Development of EMG-Triggered Functional Electrical Stimulation Device for Upper Extremity Bilateral Movement Training in Stroke Patients: Feasibility and Pilot study

  • Song, Changho;Seo, Dong-kwon
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.3
    • /
    • pp.374-378
    • /
    • 2021
  • Objective: Bilateral movement training is an effective method for upper extremity rehabilitation of stroke. An approach to induce bilateral movement through functional electrical stimulation is attempted. The purpose of this study is to develop an EMG-triggered functional electrical stimulation device for upper extremity bilateral movement training in stroke patients and test its feasibility. Design: Feasibility and Pilot study design. Methods: We assessed muscle activation and kinematic data of the affected and unaffected upper extremities of a stroke patient during wrist flexion and extension with and without the device. Wireless EMG was used to evaluate muscle activity, and 12 3D infrared cameras were used to evaluate kinematic data. Results: We developed an EMG-triggered functional electrical stimulation device to enable bilateral arm training in stroke patients. A system for controlling functional electrical stimulation with signals received through a 2-channel EMG sensor was developed. The device consists of an EMG sensing unit, a functional electrical stimulation unit, and a control unit. There was asymmetry of movement between the two sides during wrist flexion and extension. With the device, the asymmetry was lowest at 60% of the threshold of the unaffected side. Conclusions: In this study, we developed an EMG-triggered FES device, and the pilot study result showed that the device reduces asymmetry.