Estimation of Allowable Path-deviation Time in Free-space Optical Communication Links Using Various Aircraft Trajectories

  • Kim, Chul Han
    • Current Optics and Photonics
    • /
    • v.3 no.3
    • /
    • pp.210-214
    • /
    • 2019
  • The allowable path-deviation time of aircraft in a free-space optical communication system has been estimated from various trajectories, using different values of aircraft speeds and turn rates. We assumed the existence of a link between the aircraft and a ground base station. First, the transmitter beam's divergence angle was calculated through two different approaches, one based on a simple optical-link equation, and the other based on an attenuation coefficient. From the calculations, the discrepancy between the two approaches was negligible when the link distance was approximately 110 km, and was under 5% when the link distance ranged from 80 to 140 km. Subsequently, the allowable path-deviation time of the aircraft within the tracking-error tolerance of the system was estimated, using different aircraft speeds, turn rates, and link distances. The results indicated that the allowable path-deviation time was primarily determined by the aircraft's speed and turn rate. For example, the allowable path-deviation time was estimated to be ~3.5 s for an aircraft speed of 166.68 km/h, a turn rate of $90^{\circ}/min$, and a link distance of 100 km. Furthermore, for a constant aircraft speed and turn rate, the path-deviation time was observed to be almost unchanged when the link distance ranged from 80 to 140 km.

Computed Tomographic Evaluation of the Nasal Septum Deviation in Clinically Normal Dogs (정상 개에서 컴퓨터단층촬영을 이용한 비중격 변위 평가)

  • Lee, Ki-Ja;Lee, In;Lee, Hee-Chun;Han, Woo-Sok;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.28 no.5
    • /
    • pp.506-509
    • /
    • 2011
  • This study was performed to determine a comprehensive anatomic variation and deviation of the nasal septum in clinically normal dogs by use of computed tomography (CT). The nasal septum was evaluated in 36 shihtzu dogs and 16 beagle dogs. A degree of a septal deviation was evaluated by measuring a maximum angle and a distance of the septal deviation. The angle and distance of the septal deviation were significantly higher in shih-tzu dogs than in beagle dogs. There was no significant relationship between body weight and age and all measurements (angle and distance) in both breed dogs. Results of this study suggest that nasal septum deviation and its defect are observed on CT images of clinically normal dogs, especially in shih-tzu dogs.

Application of direct tension force transfer model with modified fixed-angle softened-truss model to finite element analysis of steel fiber-reinforced concrete members subjected to Shear

  • Lee, Deuck Hang;Hwang, Jin-Ha;Ju, Hyunjin;Kim, Kang Su
    • Computers and Concrete
    • /
    • v.13 no.1
    • /
    • pp.49-70
    • /
    • 2014
  • Steel fiber-reinforced concrete (SFRC) is known as one of the efficient modern composites that can greatly enhance the material performance of cracked concrete in tension. Such improved tensile resistance mechanism at crack interfaces in SFRC members can be heavily influenced by methodologies of treatments of crack direction. While most existing studies have focused on developing the numerical analysis model with the rotating-angle theory, there are only few studies on finite element analysis models with the fixed-angle model approach. According to many existing experimental studies, the direction of principal stress rotated after the formation of initial fixed-cracks, but it was also observed that new cracks with completely different angles relative to the initial crack direction very rarely occurred. Therefore, this study introduced the direct tension force transfer model (DTFTM), in which tensile resistance of the fibers at the crack interface can be easily estimated, to the nonlinear finite element analysis algorithm with the fixed-angle theory, and the proposed model was also verified by comparing the analysis results to the SFRC shear panel test results. The secant modulus method adopted in this study for iterative calculations in nonlinear finite element analysis showed highly stable and fast convergence capability when it was applied to the fixed-angle theory. The deviation angle between the principal stress direction and the fixed-crack direction significantly increased as the tensile stresses in the steel fibers at crack interfaces increased, which implies that the deviation angle is very important in the estimation of the shear behavior of SFRC members.

A Case of Seismic Crosshole Tomography Applying Borehole Deviation Correction (시추공 편차 보정을 적용한 탄성파시추공토모그래피 사례)

  • Kang, Jong-Seok;Cha, Young-Ho;Jo, Churl-Hyun;Choi, Jong-Ho;Shim, Weon-Hum;Park, Yong-Sung
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.221-224
    • /
    • 2006
  • seismic crosshole tomography works applying borehole deviation correction were performed at a test site to detect a small cavity. Two correction methods were applied. The one is the constant distance correction which adds constant distance to surface borehole distance and the other is the constant angle correction which considers an angle between surface borehole location and bottom borehole location. After applying the corrections, the distortions of the image diminished while its resolution improved. Though the constant angle correction is the most appropriate correction method, the constant distance correction can delineate the small cavity sufficiently.

  • PDF

Modeling of Deviation Angle and Pressure Loss due to Rotor Tip Leakage Flow in Axial Turbines (축류터빈의 동익에서 끝간격 누설유동에 의한 편향각과 압력손실의 모형화)

  • 윤의수;오군섭;정명균
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.13-13
    • /
    • 1998
  • A simple model of the tip leakage flow models of the rotor downstream flow is developed, based on Lakshminarayana's theoretical concept on the tip clearance flow and the experimental data published in open literature. And new spanwise distribution models of deviation angle and pressure loss coefficient due to the tip leakage flow are formulated for use in association with the streamline curvature method as a through flow analysis. Combining these new models and previous deviation and loss models due to secondary flow, a robust streamline curvature method is established for flow analysis of single-stage, subsonic axial turbines with wide ranges of turning angle, aspect ratio and blading type. At the exit from rotor rows, the flow variables are mixed radially according to a spanwise transport equation. The proposed streamline curvature method is tested against a forced vortex type turbine as well as a free vortex type one. The results show that the spanwise variations of flow angle, axial velocity and loss coefficients at rotor exit are predicted with good accuracy, being comparable to a steady three-dimensional Navier-Stokes analysis. This simple and fast flow analysis is found to be very useful for the turbine design at the initial design phase.

  • PDF

Estimation of swimming angle and body impedance of sandfish (Arctoscopus japonicus) (도루묵의 체내 임피던스 및 유영자세각 평가)

  • YOON, Euna;HWANG, Doo-Jin;OH, Wooseok;LEE, Hyungbeen;LEE, Kyounghoon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.58 no.2
    • /
    • pp.121-129
    • /
    • 2022
  • Density and sound speed contrasts (g and h, respectively), and swimming angle were measured for sandfish (Arctoscopus japonicus) without swimbladder. The density contrast was measured by the volume displacement method while the sound speed contrast was measured by the acoustic measurements of travel time (time-of-flight method). The swimming angle was measured by dividing it into daytime, nighttime, daytime feeding and nighttime feeding. The g was 1.001 to 1.067 with an average (± standard deviation) of 1.032 (± 0.017), and the h was 1.007 to 1.022 with an average (± standard deviation) of 1.015 (± 0.003). The swimming angles (mean ± standard deviation) were 16.8 ± 10.3° during the daytime, 1.9 ± 12.3° during the nighttime, 30.2 ± 12.6° in the daytime feeding and 35.0 ± 13.2° in the nighttime feeding. These results will provide important parameters input to calculate theoretical scattering models for estimating the acoustic target strength of sandfish.

Estimation of the Water Surface Slope by the Flood Discharge with River Bend Curvature (하천 만곡률과 홍수량에 따른 수면경사도 산정)

  • Choi, Han-Kyu;Lee, Mun-Hee;Baek, Hyo-Sun
    • Journal of Industrial Technology
    • /
    • v.26 no.A
    • /
    • pp.129-137
    • /
    • 2006
  • In this research, we made a one and two-dimensional analysis of numerical data collected from the bend curvature of a bended river section. According to the result from the numerical analysis, the inflow & output angle caused a water level deviation which increased with an increase of the flood discharge. From the water level deviation of our two-dimensional numerical model, we obtained the maximum slope of 6,67% when the inflow and output angle was 105 degrees and the flood discharge was 500 CMS. As for the right side, the differences with the one-dimensional numerical model were reduced when the angle was more than $90^{\circ}$. As for the left side the differences were reduced when the angle was more than $105^{\circ}$. For a river with more than 90 degrees bend curvature, a hydraulic experiment would be more appropriate than a numerical analysis.

  • PDF

Effects of the angle of secondary air inlet on the uniformity of temperature distribution inside an incinerator (2차 공기 주입각이 소각로 내부의 온도 분포 균일도에 미치는 영향)

  • Kim S. J.;Min I. H.;Park M. H.;Park M. J.
    • Journal of computational fluids engineering
    • /
    • v.5 no.3
    • /
    • pp.8-15
    • /
    • 2000
  • This research is aimed to find out how the inlet angle of secondary air affects the uniformity of temperature distribution inside a small incinerator. A commercial code, PHOENICS, is used to simulate the thermal-flow field of an incinerator. The computational grid system is constructed by Multi-Block technique provided by PHOENICS. Numerical experiments are done with the five different angles of secondary air inlet. The uniformity of temperature distribution is evaluated by checking the standard deviation of temperature distribution in an incinerator. The computational results show that there is the minimum value of standard deviation at the certain angle of secondary air inlet, which means that there is an optimum angle of secondary air inlet that could improve the uniformity of temperature distribution in an incinerator. The optimum angle of secondary air inlet is between 30 degree and 45 degree in this particular case.

  • PDF

NASAL DEVIATION IN PATIENTS WITH MANDIBULO-FACIAL ASYMMETRY (안모 비대칭환자의 두부정중선에 대한 비부의 편위)

  • Park, Ji-Hwa;Son, Seong-Il;Jang, Hyun-Jung;Kwon, Tae-Geon;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.2
    • /
    • pp.151-159
    • /
    • 2005
  • The purpose of this study was to evaluate the nasal deviation in mandibular prognathism with mandibulo-facial asymmetry. There were 40 patients whose mandibular prognathism with/without facial asymmetry were treated with orthognathic surgery from March 2002 to October 2003. The Group A(n=20) had a mandibulo-facial asymmetry over 6mm menton deviation in cephalogram PA and the Group B(n=20) had a mandibular prognathism. The preoperative frontal photograph, cephalogram PA and three dimensionalcomputed tomography(divided in hard tissuse image and soft tissue image) of two group was evaluated NDA(nasal deviation angle) and MDA(mandibular deviation angle). The NDA was statistical difference between asymmetry Group A and symmetry Group B(p<0.01), and was deviated in affected side of asymmetry. The MDA were also statistical difference between Group A and Group B(p<0.01), however the measurements of MDA between the frontal photograph, 3D-CT and cephalogram PA were similar to each others. The low correlation of NDA between frontal photograph and cephalogram PA in Group A and B demonstrate that we couldn't assess nasal deviation in cephalogram PA. It could be concluded that patients with mandibulo-facial asymmetry have a nasal deviation and clinician must remember this fact when they assess and treat patients.

A Structural Analysis and Optimization of a 60 N.m Class Flexible Disk Coupling (60 N.m급 플렉서블 디스크 커플링 구조해석 및 최적화)

  • Lee, H.K.;Kim, B.R.;Kim, S.M.;Kim, J.B.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.5
    • /
    • pp.774-781
    • /
    • 2013
  • A structural analysis was carried out for a 60 N.m class flexible disk coupling. Flexible disk couplings are used to transmit power between two shafts. When a flexible coupling is used, some amount of misalignments such as angle of deviation and end play can be allowed in assembling the shafts. However, the maximum allowable misalignment should be decided to guarantee the fatigue life. In this study, the effect of the angle of deviation and end play on the maximum stress was investigated. From the analysis results, it was shown that the angle of deviation has a greater effect on the maximum stress than the end play. Furthermore, the dimensions of the disk plate were optimized to realize a better design. From the optimization, the maximum stress could be reduced by up to 5.2%.