• 제목/요약/키워드: Deviation Angle

검색결과 512건 처리시간 0.03초

평균반경해석법을 이용한 축류압축기 성능해석 프로그램 개발 (Development of Performance Analysis Program for an Axial Compressor with Meanline Analysis)

  • 박준영;박무룡;최범석;송재욱
    • 대한기계학회논문집B
    • /
    • 제33권2호
    • /
    • pp.141-148
    • /
    • 2009
  • Axial-flow compressor is one of the most important parts of gas turbine units with axial turbine and combustor. Therefore, precise prediction of performance is very important for development of new compressor or modification of existing one. Meanline analysis is a simple, fast and powerful method for performance prediction of axial-flow compressors with different geometries. So, Meanline analysis is frequently used in preliminary design stage and performance analysis for given geometry data. Much correlations for meanline analysis have been developed theoretically and experimentally for estimating various types of losses and flow deviation angle for long time. In present study, meanline analysis program was developed to estimate compressor losses, incidence angles, deviation angles, stall and surge conditions with many correlations. Performance prediction of one stage axial compressors is conducted with this meanline analysis program. The comparison between experimental and numerical results show a good agreement. This meanline analysis program can be used for various types of single stage axial-flow compressors with different geometries, as well as multistage axial-flow compressors.

전향도가 큰 축류터보기계의 블레이드 주위의 유동해석 (Analysis of Two-Dimensional Flow around Blades with Large Deflection in Axial Turbomachine)

  • 원승호;손병진;최상경
    • 대한기계학회논문집
    • /
    • 제15권1호
    • /
    • pp.229-240
    • /
    • 1991
  • 본 연구에서 사용한 이론과 제시된 방법의 타당성을 검토하기 위하여 익열 간 극이 무한대인 단일 익형 주위의 유동장을, 최근에 개발된 계산방법인 Lambda방법을 사용한 Dadone의 해석결과와 비교하였고, 범용의 압축기 익형인 NACA65게열 익열 유동 에 대한 Herrig의 실험값, 그리고 미분해석에 의한 점성-비점성 상호작용 방법을 사용 한 Hansen의 계산값고, 이들 조건과 동일한 상태에서 본 연구에서 제시한 방법으로 계 산한 결과와 만족할 만한 일치를 얻었다.

Unbiased Estimators of Standard Deviation in a Truncated Arcsine Distribution

  • Woo, Jung-soo;Kim, Jung-dae;Lee, Chang-soo
    • Communications for Statistical Applications and Methods
    • /
    • 제4권2호
    • /
    • pp.507-514
    • /
    • 1997
  • Three kinds of unbiased estimators of standard deviation in a truncated arcsine distribution based on the quasi-range, the jackknife quasi-range, and the angle jackknife range are proposed and numerically compared each other in a sense of MSE.

  • PDF

웨이퍼 정렬법과 정밀도 평가 (A Wafer Alignment Method and Accuracy Evaluation)

  • 박홍래;유준
    • 제어로봇시스템학회논문지
    • /
    • 제8권9호
    • /
    • pp.812-817
    • /
    • 2002
  • This paper presents a development of high accuracy aligner and describes a method to find the orientation of a substantially circular disk shaped wafer with at least one flat region on an edge thereof. In the developed system, the wafer is spun one 360 degree turn on a chuck and the edge position is measured by a linear array to obtain a set of data points at various wafer orientation. The rotation axis may differ from wafer center by an unknown eccentricity. The flat angle is found by fitting a cosine curve to the actual data to obtain a deviation. The maximum deviation is then corrected for errors due to a finite number of data points and wafer eccentricity by calculating an adjustment angle from data points on the wafer fiat. After determining the flat angle the wafer is spun to the desired orientation. The wafer eccentricity can be calculated from four of the data points located away from the flat edge region. and the wafer is then centered.

안면비대칭 환자의 natural head position에 대한 정모두부방사선사진 연구 (Frontal Cephalogram Study on The Natural Head Position of Facial Asymmetry Patients)

  • 김현;황현식
    • 대한치과교정학회지
    • /
    • 제30권5호
    • /
    • pp.535-542
    • /
    • 2000
  • 본 연구는 안면비대칭 환자의 natural head position(NHP)시 정면에서의 두부 또는 경추의 경사 정도를 알아봄으로써 교정환자의 임상검사시 비대칭의 진단에 도움이 되고자 시행되었다. 두드러진 전후방 골격 이상은 없으나 뚜렷한 좌우 안면비대칭을 보이는 성인 20명을 비대칭군으로, 좌우 대칭적인 외모와 비교적 정상교합을 보이는 성인 21명 을 대칭군으로 선정 한 다음 물방울 수평계를 이용하여 NHP 상태의 정모두부방사선사진을 촬영하고 투사도를 작성하였다. Crista galli와 anterior nasal spine을 연결한 선과 crista galli와 menton을 연결한 선이 이루는 각을 menton의 변위 정도로 정하고, 좌우 supra-orbital margin의 최상방점을 지나는 supra-orbital line과, 제1경추와 제4경추의 중심을 연결한 cervical line이 각각 true vertical line과 이루는 각을 계측한 다음 이들간의 상관관계를 비교 분석하여 다음과 같은 결과를 얻었다. 1. Supra-orbital line이 true vortical line과 이루는 각이 직각에서 벗어난 정도가 대칭군에 비하여 비대칭군에서 통계적으로 유의하게 크게 나타났다. 2. Cervical line이 true vertical line과 이루는 각은 통계적 유의차는 없었으나 비대칭군에서 더 큰 경향을 보였다. 3. 비대칭군에서 supra-orbital line이 true vortical line과 이루는 각이 직각에서 벗어난 정도는 menton의 변위 정도와 통계적으로 유의한 순상관관계를 보였다. 이상의 결과로 안면비대칭 환자는 menton의 변위를 보상하려는 방향으로 기울어진 NHP를 가지는 경향이 있음을 알 수 있었다.

  • PDF

근광장 측정에서 방사선 사진술의 정확도 (The Accuracy of the Radiographic Method in Root Canal Length Measurement)

  • 조은영;박창서
    • 치과방사선
    • /
    • 제28권2호
    • /
    • pp.471-489
    • /
    • 1998
  • For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora/sup (R)/, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora/sup (R)/ system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora/sup (R)/ system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems(p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems(p>0.05). 2. In Digora/sup (R)/ system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques(p<0.05). Also, in the standard periapical radiographs, the average difference between the bisecting angle and paralleling technique was 0.328 mm and the standard deviation was 0.517 mm which showed a statistically significant difference between these two techniques(p<0.05). 3. In Digora/sup (R)/ system and the standard periapical radiographs. there was a statistically significant difference between the measurement using the bisecting angle technique and the actual length(p<0.05), But there was no statistically significant difference between the measurement using the paralleling technique and the actuallength(p>0.05). In conclusion. the determination of the root canal length by using the Digora/sup (R)/ system can give us as good an image as the standard periapical radiograph and using the paralleling technique instead of the bisecting angle technique can give a measurement closer to the actual canal length. thereby contributing to a successful result. Also. considering the advantages of the digital imaging processor such as decreasing the amount of exposure to the patient. immediate use of the image. magnification of image size. control of the contrast and brightness and the ability of storing the image can give us good reason to replace the standard periapical radiographs.

  • PDF

무지외반증에서 한국인의 정상 방사선각도 계측치에 대한 연구 (Measurement of the Angle related Hallux Valgus in Normal Korean Adults)

  • 이경태;송준섭
    • 대한족부족관절학회지
    • /
    • 제1권1호
    • /
    • pp.11-14
    • /
    • 1997
  • Hallux valgus is a complex deformity which contains static subluxation of the first metatarsophalangeal joint with lateral deviation of the great toe and medial deviation of the first metatarsal bone. Among the several parameters, radiographic indices are the important ones in the choice of the treatment method. Even though, the normal values of the western peoples are already estabilished, there was no standard values for Korean who has different genetics, and cultural background, till now. So, we tried to estimate the noraml values of the HVA (hallux valgus angle ), IMA ( Intermetatarsal angle) and DMAA (Distal Metatarsal Articular surface Angle) in a normal adult. Fifty normal adult (each 25 male and female) were chosen and took 100 cases of foot radiograph and radiologic indices of the hallux valgus were measured. Average age at the investigation was 34.5 years old. The average HVA is $13.3^{\circ}$, IMA is $8.5^{\circ}$ and DMAA is $34.6^{\circ}$.

  • PDF

영구자석 동기 전동기의 제정수 오차가 센서리스 운전에 미치는 영향 (Effects of Parameter Errors on Sensorless Operation of PMSM)

  • 박용순;설승기;지준근;박영재;이동환
    • 전력전자학회논문지
    • /
    • 제16권1호
    • /
    • pp.71-78
    • /
    • 2011
  • 본 논문에서는 영구자석 동기 전동기의 센서리스 운전에 있어, 제어에 사용되는 제정수의 오차가 각도 추정 성능에 미치는 영향을 분석하였다. 회전 자속의 위치를 추정하는데 사용되는 위치 오차 정보를 부호 요인과 이득 요인으로 나누어, 그 중에 각도 추정의 편차를 초래하는 부호 요인을 중심으로 제정수 오차가 각도 추정 성능에 미치는 영향을 분석하였다. 본 논문에서는 센서리스 제어에 사용되는 저항과 인덕턴스의 오차로 표현되는 각도 추정 편차의 함수를 수식적으로 도출하였고, 모의실험 및 실험을 통해 도출된 수식의 타당성을 검증하였다.

장정에 시행한 몇가지 평가기능 검사성적에 대한 고찰 (The Results of Various Vestibular Function Tests in Young Male Adult)

  • 박찬일;추광철;노관택
    • 대한기관식도과학회:학술대회논문집
    • /
    • 대한기관식도과학회 1972년도 춘계종합 학술대회 초록집
    • /
    • pp.2.3-2
    • /
    • 1972
  • 평형기능검사는 평형장애의 객관적인 소견을 찾으려는 것이며 평형장해의 양상을 분석하고 장해부위를 추정하여 장해의 원인을 구명하는데 그 목적을 두고 있다. 이중 전정척수반사는 미로로부터의 자극이 전신횡문근군 근긴장에 영향을 주어 안정시 또는 운동시의 체위변화에 관여하고 있는 데에 그 임상적 의의가 있다. 이 반사는 안진과 같은 전정안반사를 일으킬 수 없는 미로에 대한 미약한 자극에 의하여도 야기될 수 있으므로 평형기능의 기본검사로 시행되어야 한다. 저자들은 100명의 건장한 청년 남자에서 단각직위검사, 보행검사, 족답검사 및 차안서자법을 시행하여 다음과 같은 성적을 얻었다. 1. 단각직위검사 30초간의 접상회수는 우각거상는 5회 이내이었으며 평균 0.68회로 나타났다. 2. 보행검사 전달시의 편기는 100cm 이내에 분포되어 있었으며 평균편기치는 우측으로 22.5cm, 죄측으로는 26.1cm이었다. 후진시의 편기는 140cm 이내에 분포되어 있었으며 평균편기치는 좌측으로 35.4cm, 좌측으로는 330cm이었다. 3. 족답검사 정상두위에서는 전방이행이 93%, 후방이행이 5%이었으며 이행각의 방향은 우측 36%, 좌측 50%, 회전각의 방향은 우측 53%, 좌측 36%로 나타났다. 후경두위에서는 전방이행이 94%, 후방이행이 3%이었으며 이행각의 방향은 우측 34%, 좌측 55%, 회전각의 방향은 좌측 50%, 좌측 42%로 나타났다. 평균편기치는 정상두위에서는 이행각 22.05도, 이행거이 48.95cm, 회전각 24.40도, 후경두위에서는 이행각 29.22도, 이행거이 44.17cm, 회전각 39.58도로 나타났다. 4. 차안서자법 편서방향은 정두위, 후경두위, 우경두위, 좌경두위 등에 따라 약간의 차이가 있으나 좌측편서가 54~69%로 우측편서 24.40%보다 많으며 나머지에서는 3~7% 편서를 보이지 않았다. 편서각도는 좌우 각각 두위변화에 따라 0~16도 사이에 분포되어 있으며 정두위에서는 0~12도, 평균편서각도는 4.15~5.76도 사이에 분포를 보이었다.

  • PDF

퍼터의 라이각과 로프트각이 퍼팅한 공의 방향성에 미치는 영향 (Directional relationships of the golf ball with lie and loft angle of the putter)

  • 임형진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1496-1500
    • /
    • 2008
  • Less than 1 % directional error in the range of 5 meters in the green could cause a stroke or more. Although there are several reasons offsetting the direction of the golf ball, lie angle and sidespin effect are the most crucial factors of the putting game. Simple equation is conformed to the experimental results of the deviation of the directional error in all distance. Also, the experimental results of the putting robot show that there are significant side spin effects.

  • PDF