• Title/Summary/Keyword: Development rate

Search Result 12,970, Processing Time 0.053 seconds

Germination of Yam Bean Seeds as Affected by Temperature and Its Productivity with Different Seeding Dates (얌빈의 온도별 발아특성과 파종시기에 따른 생산성 비교)

  • Uhm, Mi Jeong;Kim, Chi Seon;Kim, Eun Ji;Jung, Hyun Soo;Kim, Jeong Man
    • Journal of Bio-Environment Control
    • /
    • v.27 no.3
    • /
    • pp.245-252
    • /
    • 2018
  • Yam bean (Pachyrhizus erosus) is a subtropical plant belonging to the Fabaceae family, and is a tuberous vegetable used as various food material with a crisp and juicy taste. This study was conducted to seek optimum sowing time of yam bean in Korea. For this, we surveyed germination properties by the different temperatures and compared the accumulation temperature (AT) and dry matter production (DMP) on growth stages of yam bean by the different sowing times. Two types of varieties cultivated mainly in Korea, Thailand local variety (TLV) and Cheongunmanma cultivar (CGMM), was used. The germination rate of yam bean was 86.0~94.0% at above $18^{\circ}C$, and germination days was longer at lower temperature. The times for flowering and tuber formation of CGMM were later than those of TLV, and the AT required for flowering, tuber formation and hypertrophy of CGMM were higher than those of TLV by $293^{\circ}C$, $280^{\circ}C$ and $108^{\circ}C$, respectively. Also, DMP of shoot and tuber in CGMM were greater than those in TLV. In sowing at April 25, tuber formation was slower than sowing after that time, and harvest index (HI) was relatively low due to delayed formation and hypertrophy of tuber. In sowing after June 9, DMP of shoot was relatively greater in early growth, but tuber was not sufficient to enlarge due to lack of growth days by cold and frost in late October. In sowing May 10 and 25, DMP of tuber and HI were the highest, because the change of day length and temperature gave an advantage to vegetable growth and tuber development. All above suggest that it was suitable to sow seeds on May for increment of tuber productivity in Korea.

Effects of Combination of Air Temperature and Soil Moisture Contents on Growth, Clove Initiation, Physiological Disorders, and Yield of Garlic (기온과 토양수분 함량에 따른 난지형 마늘의 생장, 인편분화, 생리장해 및 수량에 미치는 영향)

  • Lee, Hee Ju;Lee, Sang Gyu;Kim, Sung Kyeom;Mun, Boheum;Lee, Jin Hyoung;Lee, Hee Su;Kwon, Young Seok;Han, Ji Won;Kim, Cheol Woo
    • Journal of Bio-Environment Control
    • /
    • v.27 no.3
    • /
    • pp.191-198
    • /
    • 2018
  • The objective of this study was to determine the effects of combination of air temperature and soil water contents on growth, physiological disorder rate, and yield of garlic. This experiments has been carried out in the typical plastic house (one side open and other side installed ventilation fans) which was maintained gradient air temperature (maximum different value of air temperature : $6^{\circ}C$). The excessive irrigation (EI) set at $0.34m^3/m^3$ soil moisture contents. The significant differences found in the growth parameters of garlics as affected by air temperature and soil moisture conditions. The plant height of garlic with combination of ambient $(A)+6^{\circ}C$ and optimal irrigation (OI; set at $0.22m^3/m^3$ soil moisture contents) treatments represented 47.4 cm/plant, which was the highest among all the tested treatments. The leaf length and width showed the greatest, which were 16.1 and 2.4 cm/plant, respectively, in $A+6^{\circ}C-OI$. The physiological disorder ratio was higher as 12.9% at $A+6^{\circ}C-OI$ and was not occurred at ambient temperature with EI compared with OI treatment. The bulb and clove weight were dramatically decreased at $A+6^{\circ}C$ temperature treatment. The yields were decreased by 51% in OI at $A+6^{\circ}C$ and $A+3^{\circ}C$ temperature treatment. Those results indicated that yields were decreased and ratio of physiological disorders was increased by high temperature treatments.

Changes in Growth and Physiological Characteristics of Tetradium daniellii (Benn.) T. G. Hartley Container Seedlings by Shading Treatment (차광처리에 따른 쉬나무 용기묘의 생장 및 생리적 특성 변화)

  • Choi, Kyu Seong;Sung, Hwan In;Kim, Jong Jin;Song, Ki Seon
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.130-140
    • /
    • 2020
  • This study was conducted in order to closely examine about optimum shading for superior seedling production a container seedling of Tetradium daniellii, which is being increased the demand for a seedling due to being used for alternative energy, ecological restoration and honey plant. The experiment of investigating the optimum shading on T. daniellii was carried out by using plastic container types (350 ml/cavity) for the forestry facility cultivation. The shading level was treated with full sunlight and with 35%, 55%, 75% of the full sunlight. As a result of having surveyed height and root collar diameter growth of a containerized seedling in T. daniellii, a case of the shading experiment showed a noticeably high value was indicated in the full sunlight. It was surveyed that the stronger shading level leads to the lower growth value. Root development was most active in full sunlight. Dry matter production, it was investigated to be the highest in full sunlight. It was surveyed to be the similar tendency to the outcome of height and root collar diameter growth. QI, which is index of showing the quality of a seedling, stood at 0.98 in full sunlight, thereby having been investigated to be the highest. As for the chlorophyll content in a seedling, the highest chlorophyll content was indicated in the 75% shading treatment with the relatively highest shading level. The photosynthetic rate and the water use efficiency were surveyed to be the highest in full sunlight with 8.48 μmolCO2·m-2s-1, 1.40 μmolCO2·mmolm-1H2O, respectively. As a result of surveying the whole experiment, optimum shading level for superior seedling production a container seedling of T. daniellii is determined in full sunlight (0%). It is expected that this will be used as a basic data for mass production.

Culture characteristics of Pleurotus commercial strains at different temperature (계절별 온도에 따른 느타리 품종의 재배적 특성)

  • Yoo, Young Bok;Seo, Kyoung In;Kong, Won Sik;Jang, Kab Yeul;Shin, Pyung Gyun;Park, Yunjung
    • Journal of Mushroom
    • /
    • v.7 no.3
    • /
    • pp.122-129
    • /
    • 2009
  • We determined the genetic relatedness among 81 commercial varieties of oyster mushrooms by either comparison of fruiting body characteristics or using PCR amplification with URP primers. Also, we assessed their temperature adaptation by using box cultivation. Based on our data, some varieties such as Wonhyung and variety 1, Suhan and variety 20, Wang-hukpyung and variety 4, Chunchu #2 and variety 6, Shinong #11 and variety 1, Samgu #1 and variety 2, showed the close genetic relatedness between each other. It is known that mushroom culture room is affected by outer temperature because mushroom need the adequate aeration for their growth. Therefore, in aspect of saving energy, the cultivation of season favorable mushroom species has been recommended. Eight different commercial varieties including Sa-chul, Yeoreum and Bunhong(Pink) grew well at high temperature ($16^{\circ}C$). Also, about 51 different oyster mushroom strains were good at relatively high temperature. However, other 64 different oyster mushroom varieties were grew well at low temperature ($11^{\circ}C$). Fourty-nine varieties were adapted well in most temperatures. The slow growth rate were observed in some varieties including Kun(P. eryngii ), Awi(P. nebrodensis ), and Cheunbok(P. abalonus ), which are not suitable for box cultivation. We believe that the culture characterization of each mushroom varieties should help many farmers in many aspects such as saving energy, quantity improvement and new variety development etc.

  • PDF

Development of KD- Propeller Series using a New Blade Section (새로운 날개단면을 이용한 KD-프로펠러 씨리즈 개발)

  • J.T. Lee;M.C. Kim;J.W. Ahn;H.C. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.28 no.2
    • /
    • pp.52-68
    • /
    • 1991
  • A new propeller series is developed using the newly developed blade section(KH18 section) which behaves better cavitation characteristics and higher lift-drag ratio at wide range of angle-of-attack. The pitch and camber distributions are disigned in order to have the same radial and chordwise loading distribution with the selected circumferentially averaged wake input. Since the geometries of the series propeller, such as chord length, thickness, skew and rate distribations, are selected by regression of the recent full scale propeller geometric data, the performance prediction of a propeller at preliminary design stage can be mure realistic. Number of blades of the series propellers is 4 and the expanded blade area ratios are 0.3, 0.45, 0.6 and 0.75. Mean pitch ratios are selected as 0.5, 0.65, 0.8, 0.75 and 1.1 for each expanded area ratio. The new propeller series is composed of 20 propellers and is named as KD(KRISO-DAEWOO) propeller series. Propeller open water tests are performed at the experimental towing tank, and the cavitation observation tests and fluctuating pressure measurements are carried out at the cavitation tunnel of KRISO. $B_{P}-\delta$ curves, which can be used to select the optimum propeller diameter at the preliminary design stage, are derived from a regression analysis of the propeller often water test results. The KD-cavitation chart is derived from the cavitation observation test results by choosing the local maximum lift coefficient and the local cavitation number as parameters. The caviy extent of a propeller can be predicted more accurately by using the KD-cavitation chart at a preliminary design stage, since it is derived from the results of the cavitation observation tests in the selected ship's wake, whereas the existing cavitation charts, such as the Burrill's cavitation chart, are derived from the test results in uniform flow.

  • PDF

Development of pallet-scale modified atmosphere packaging for 'Tabor' tomatoes (토마토 'Tabor' 품종의 파렛트 단위 MAP 적용 연구)

  • Park, Jong Woo;Kim, Jinse;Park, Seok Ho;Choi, Dong Soo;Choi, Seung Ryul;Kim, Yong Hoon;Lee, Soo Jang;Park, Chun Wan;Lee, Jung Soo
    • Food Science and Preservation
    • /
    • v.23 no.5
    • /
    • pp.614-622
    • /
    • 2016
  • This study was carried out to investigate the effect of modified-atmosphere packaging (MAP) on the quality change of "Tabor" tomatoes during long-term exportation periods. Hydroponics tomatoes were harvested at the turning stage, sorted, and box packed and then packaged in nylon film with a pallet. The packaged pallet was filled with a gas composition (5% $O_2$, 1% $CO_2$, and 94% $N_2$) and stored at $10^{\circ}C$ for three weeks. The quality changes in weight loss, firmness, color, acidity, soluble solids, and microorganism growth were measured every 7 day interval. During the initial storage, the pallet-scale MAP showed slightly higher weight loss and firmness changes when compared to the conventional pallet. The total color change (${\Delta}E$) during ripening was delayed 10% under MAP storage. Acidity, soluble solids and phenolic compound contents decreased with increases in storage time regardless of the storage method; however, the quality changes of tomatoes were delayed in the MAP pallet. Furthermore, the decay rate of the pallet-scale MAP stored for 14 days was less than that of the conventional pallet, and the number of microorganisms was approximately 30% lower in the pallet-scale MAP, showing a positive effect on marketability. These results suggested that the pallet-scale MAP of tomatoes could ensure higher quality and longer storage periods than conventional pallet storage.

Study on the Meteological Effects on the Plant Growth and Yield of Rice (기상요인(氣象要因)이 수도(水稻)의 생육(生育) 및 수량(收量)에 미치는 영향(影響))

  • Jo, Jai Seong;Lee, Jong Cheol
    • Korean Journal of Agricultural Science
    • /
    • v.2 no.1
    • /
    • pp.111-123
    • /
    • 1975
  • 6 years data on the plant growth and grain yield of 13 rice varieties were investigated to define the relations between meteological conditions and plant growth of rice including grain yield. The results obtained are summarized as follows; 1. Variation of average temperature by years showed great number at early and middle July, middle August and early November, however smallest figure at late June and late July. And that of sunshine hours by years were least at late June and late July, and largest at middle July. 2. Among rice yield components variation of panicle number per hill by years was biggest and that of 1000 grain weight least. Rate of variation of plant growth and rice yield was different by rice varieties. 3. Direct effects on rice yield was greatest at maturing ratio and next at 1000 grain weight. The effects of yield factor on the rice yield wers different by years. 4. Higher temperature and longer sunshine delayed the miaxmum tillering stage but shortened the days from seeding to heading. 5. A significant negative correlation was recognized between the number of panicles per hill and average temperature of 11 to 40 days after transplanting, and number of grains per panicle was correlated with the average temperature of 11 to 70 days after transplanting. High temperature before heading time showed atime decreased maturing ratio. 6. Accumulated temperature was highly correlated with 1000 grain weight in all season. Highest positive correltaion was recognized between grain yield of rice and average temperature of 61 to 70 days after transplanting but correlations between rice yield and average temperature after heading stage were negative. 7. Highly significant correlations were confirmed between maturing ratio and sunshine hours of 31 to 50 days as well as 61 to 70 days after transplanting, and maturing ratio was highly correlated with accumulated hours of sunshine. Correlation between rice yield and hours of sunshine was significant at 51 to 60 days after transplanting.

  • PDF

Effects of CP AP Therapy on Systemic Blood Pressure, Cardiac Rhythm and Catecholamines Concentration in Patients with Obstructive Sleep Apnea (폐쇄성 수면 무호흡에서 CPAP 치료가 전신성 혈압, 심조율 및 catecholamines 농도에 미치는 영향)

  • Kang, Ji-Ho;Lee, Sang-Haak;Choi, Young-Mee;Kwon, Soon-Seog;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Song, Jeong-Sup;Park, Sung-Hak;Moon, Hwa-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.6
    • /
    • pp.715-723
    • /
    • 2000
  • Background : Obstructive sleep apnea syndrome (OSAS) affects systemic blood pressure and cardiac function. The development of cardiovascular dysfunction including the changes of systemic blood pressure and cardiac rhythm, suggests that recurrent hypoxia and arousals from sleep may increase a sympathetic nervous system activity. Continuous positive airway pressure (CPAP) therapy has been found to be an effective treatment of OSAS. However, only a few studies have investigated the cardiovascular and sympathetic effects of CPAP therapy. We evaluated influences of nasal CPAP therapy on the cardiovascular system and the sympathetic activity in patients with OSAS. Methods : Thirteen patients with OSAS underwent CPAP therapy and were monitored using polysomnography, blood pressure, heart rate, presence of arrhythmia and the concentration of plasma catecholamines, before and with CPAP therapy. Results: The apnea-hypopnea index (AHI) was significant1y decreased (p<0.01) and the lowest arterial oxygen saturation level was elevated significantly after applying CPAP (p<0.01). Systolic blood pressure tended to decrease after CPAP but without statistical significance. Heart rates during sleep were not significantly different after CPAP. However, the frequency and number of types of arrhythmia decreased and sinus bradytachyarrhythmia disappeared after CPAP. Although there was no significant difference in the level of plasma epinephrine concentration, plasma norepinephrine concentration significantly decreased after CPAP (p<0.05). Conclusion : CPAP therapy decreased the apnea-hypopnea index, hypoxic episodes and plasma norepinephrine concentration. In addition, it decreased the incidence of arrhythmia and tended to decrease the systemic blood pressure. These results indicate that CPAP may play an important role in the prevention of cardiovascular complications in patients with OSAS.

  • PDF

A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS (공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구)

  • Park Cheol;Lim Ju-Hwan;Cho In-Ho;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

Detection with a SWNT Gas Sensor and Diffusion of SF6 Decomposition Products by Corona Discharges (탄소나노튜브 가스센서의 SF6 분해생성물 검출 및 확산현상에 관한 연구)

  • Lee, J.C.;Jung, S.H.;Baik, S.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.1
    • /
    • pp.66-72
    • /
    • 2009
  • The detection methods are required to monitor and diagnose the abnormality on the insulation condition inside a gas-insulated switchgear (GIS). Due to a good sensitivity to the products decomposed by partial discharges (PDs) in $SF_6$ gas, the development of a SWNT gas sensor is actively in progress. However, a few numerical studies on the diffusion mechanism of the $SF_6$ decomposition products by PD have been reported. In this study, we modeled $SF_6$ decomposition process in a chamber by calculating temperature, pressure and concentration of the decomposition products by using a commercial CFD program in conjunction with experimental data. It was assumed that the mass production rate and the generation temperature of the decomposition products were $5.04{\times}10^{-10}$ [g/s] and over 773 K respectively. To calculate the concentration equation, the Schmidt number was specified to get the diffusion coefficient functioned by viscosity and density of $SF_6$ gas instead rather than setting it directly. The results showed that the drive potential is governed mainly by the gradient of the decomposition concentration. A lower concentration of the decomposition products was observed as the sensors were placed more away from the discharge region. Also, the concentration increased by increasing the discharge time. By installing multiple sensors the location of PD is expected to be identified by monitoring the response time of the sensors, and the information should be very useful for the diagnosis and maintenance of GIS.